Sarra Ben Hamida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sarra Ben Hamida has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Fatima Abusua
Department of Prosthodontics, Faculty of Dentistry, University of Tripoli, Tripoli, Libya
2 shared publications - Mohamed Elmaroush
Department of Prosthodontics, Faculty of Dentistry, University of Tripoli, Libya
2 shared publications - Narjes Mohsen
Department of Prosthodontics, Faculty of Dentistry, University of Tripoli, Tripoli, Libya
2 shared publications Neji Ladhari
Higher Institute of the Fashion Trades, Stah Jabeur Golf Avenue 5000, Monastir, Tunisia
2 shared publicationsDušan Kováčik
CEPLANT, Department of Plasma Physics and Technology, Faculty of Science, Masaryk University, Brno, Czech Republic
1 shared publicationIndu Ambat
Department of Green Chemistry, School of Engineering Science, Lappeenranta University of Technology, Sammonkatu 12, FI-50130 Mikkeli, Finland
1 shared publication
Latest Publications
- Open Access
- 22 September 2025
- Published by Attahadi Medical University
- p. 334-338
Comparative Analysis of Flexural Strength between Heat Polymerized PMMA, Injectable Flexible Nylon-Based Resin, and CAD/CAM (PEEK) Denture Base Materials: An In-Vitro Study
This study aimed to compare the flexural strength of Heat Polymerized PMMA, Injectable Flexible Nylon-Based Resin, and CAD/CAM Polyether Ether Ketone (PEEK) denture base materials. A total of 36 rectangular samples with dimensions of (64mm x 10 mm x 3.3mm) were fabricated from Heat Polymerized PMMA, Injectable Flexible Nylon-Based Resin, and CAD/CAM (PEEK). These samples were divided into three groups of 12 samples. The three-point flexural strength test was carried out using a universal testing machine. A one-way analysis of variance (ANOVA) test was used for statistical analysis. Statistical significance was set at P ≤ 0.05. The flexural strength of CAD/CAM (PEEK) (137.92 ± 8.92555 MPa) was the highest, followed by Heat Polymerized Acrylic Resin (75.162 ± 9.40870 MPa), and the lowest was for Injectable Flexible Nylon-Based Resin (54.01 ± 20.29325 MPa). Considering the study’s limitations, CAD/CAM PEEK showed the highest flexural strength, followed by heat-polymerized PMMA, while injectable flexible nylon-based resin exhibited the lowest strength. These findings suggest that PEEK may provide more durable and reliable denture bases, potentially improving prosthesis longevity and patient satisfaction
- 22 September 2025
- Published by Attahadi Medical University
- p. 334-338
Open AccessComparative Analysis of Flexural Strength between Heat Polymerized PMMA, Injectable Flexible Nylon-Based Resin, and CAD/CAM (PEEK) Denture Base Materials: An In-Vitro Study
This study aimed to compare the flexural strength of Heat Polymerized PMMA, Injectable Flexible Nylon-Based Resin, and CAD/CAM Polyether Ether Ketone (PEEK) denture base materials. A total of 36 rectangular samples with dimensions of (64mm x 10 mm x 3.3mm) were fabricated from Heat Polymerized PMMA, Injectable Flexible Nylon-Based Resin, and CAD/CAM (PEEK). These samples were divided into three groups of 12 samples. The three-point flexural strength test was carried out using a universal testing machine. A one-way analysis of variance (ANOVA) test was used for statistical analysis. Statistical significance was set at P ≤ 0.05. The flexural strength of CAD/CAM (PEEK) (137.92 ± 8.92555 MPa) was the highest, followed by Heat Polymerized Acrylic Resin (75.162 ± 9.40870 MPa), and the lowest was for Injectable Flexible Nylon-Based Resin (54.01 ± 20.29325 MPa). Considering the study’s limitations, CAD/CAM PEEK showed the highest flexural strength, followed by heat-polymerized PMMA, while injectable flexible nylon-based resin exhibited the lowest strength. These findings suggest that PEEK may provide more durable and reliable denture bases, potentially improving prosthesis longevity and patient satisfaction
- Open Access
- 7 February 2025
- Published by Medical Research Center in AlQalam Journal of Medical and Applied Sciences
- p. 230-235
In Vitro Evaluation of the Fracture Strength among Three Different Denture Base Materials
Failure in the form of denture fracture is commonly encountered by both removable prosthodontics wearers and dentists, it is mainly attributed to material properties, technical features, stresses while in function or due to impact as a consequence of dropping the dentures. Traditionally, Heat-Polymerized Polymethylmethacrylate (PMMA) has been the gold standard for denture bases due to its ease of processing and acceptable mechanical properties. However, newer materials, injectable flexible nylon-based resin and CAD/CAM Polyether ether Ketone (PEEK) denture bases are being introduced with claims of superior strength and durability. The aim of this study was to investigate the fracture strength of three commonly used denture base materials in Libya, which may aid in selecting the best material for a given application and predicting potential material behavior under load when holding the durability of the material in mind. A total of 36 samples were tested. These samples were divided into three groups, with 12 samples each: Group I heat polymerized acrylic resin PMMA, group II Injectable flexible nylon-based resin and group III CAD/CAM (PEEK). The fracture strength test was carried out on a universal testing machine at a crosshead speed of 5 mm/min. The results were analyzed using ANOVA, and multiple comparisons were undertaken using Tukey’s HSD test. Statistical significance was set at P ≤ 0.001. The result of this study shows there were significant differences in the fracture strength among the three groups (P< 0.001). Moreover, CAD/CAM (PEEK) denture base material exhibited significantly the highest fracture strength (234.17N ± 13.5) whereas the least fracture strength value was measured with Injectable flexible nylon-based resin denture base material (75.25N±10.5). The study concluded that, within the limitations of this study, the results demonstrate that CAD/CAM (PEEK) outperforms Injectable flexible nylon-based resin and heat polymerized acrylic denture base materials in terms of the fracture strength, supporting its potential as an advanced material for denture construction. However, further clinical studies are recommended.
- 7 February 2025
- Published by Medical Research Center in AlQalam Journal of Medical and Applied Sciences
- p. 230-235
Open AccessIn Vitro Evaluation of the Fracture Strength among Three Different Denture Base Materials
Failure in the form of denture fracture is commonly encountered by both removable prosthodontics wearers and dentists, it is mainly attributed to material properties, technical features, stresses while in function or due to impact as a consequence of dropping the dentures. Traditionally, Heat-Polymerized Polymethylmethacrylate (PMMA) has been the gold standard for denture bases due to its ease of processing and acceptable mechanical properties. However, newer materials, injectable flexible nylon-based resin and CAD/CAM Polyether ether Ketone (PEEK) denture bases are being introduced with claims of superior strength and durability. The aim of this study was to investigate the fracture strength of three commonly used denture base materials in Libya, which may aid in selecting the best material for a given application and predicting potential material behavior under load when holding the durability of the material in mind. A total of 36 samples were tested. These samples were divided into three groups, with 12 samples each: Group I heat polymerized acrylic resin PMMA, group II Injectable flexible nylon-based resin and group III CAD/CAM (PEEK). The fracture strength test was carried out on a universal testing machine at a crosshead speed of 5 mm/min. The results were analyzed using ANOVA, and multiple comparisons were undertaken using Tukey’s HSD test. Statistical significance was set at P ≤ 0.001. The result of this study shows there were significant differences in the fracture strength among the three groups (P< 0.001). Moreover, CAD/CAM (PEEK) denture base material exhibited significantly the highest fracture strength (234.17N ± 13.5) whereas the least fracture strength value was measured with Injectable flexible nylon-based resin denture base material (75.25N±10.5). The study concluded that, within the limitations of this study, the results demonstrate that CAD/CAM (PEEK) outperforms Injectable flexible nylon-based resin and heat polymerized acrylic denture base materials in terms of the fracture strength, supporting its potential as an advanced material for denture construction. However, further clinical studies are recommended.
- Open Access
- 16 April 2023
- Published by Faculty of Dentistry Khalij-Libya Dental College in Khalij-Libya Journal of Dental and Medical Research
- p. 29-33
Evaluation the Presence of Border Molding in Final Impression for Fabrication of Removable Prosthesis by General Practitioner in Tripoli, Libya
Background and objectives. Cross infection among prosthodontologist and dental lab technicians is very important issue, especially after several studies found that transmission of infection to dental lab technicians is mainly by contaminated impressions or by improper handling of clinical items after arrival at the Dental laboratory. Dental impressions can be cross-contaminated by patient’s saliva and blood, which then cross-infect the dental casts poured from the impressions. The present study was carried out to evaluate the knowledge and the practice of infection control of dental impressions among dental technicians in Tripoli, Libya. Methods. This study was based on questionnaire that designed to cover different aspects of cross-infection control in the dental clinic. The questionnaire consists of 10 closed end question and 3 yes, no question. Results. The response rate was 85%. The questionnaire showed that almost 32.9% of the dental technicians did not have instructions related to disinfection in the dental lab. Upon receipt of dental impressions, the majority (80.5%) reported always rinsing them with water only. Moreover, about 7.8% of the dental technicians reported never disinfecting dental impressions and about 16.9% reported that they sometimes disinfected impressions. In the labs were the disinfection applied, 12% of the dental labs used spray disinfection (without water) and also 12% of dental technicians used immersion disinfection (without water). Conclusion. The findings of this study show that practices and awareness of dental technicians regarding infection control are less than ideal, moreover there is lack of communication between dentists and dental technicians so should increase awareness and establishing educational programs for both dentists and dental technicians to decrease the risk of transmission of diseases in dental laboratories.
- 16 April 2023
- Published by Faculty of Dentistry Khalij-Libya Dental College in Khalij-Libya Journal of Dental and Medical Research
- p. 29-33
Open AccessEvaluation the Presence of Border Molding in Final Impression for Fabrication of Removable Prosthesis by General Practitioner in Tripoli, Libya
Background and objectives. Cross infection among prosthodontologist and dental lab technicians is very important issue, especially after several studies found that transmission of infection to dental lab technicians is mainly by contaminated impressions or by improper handling of clinical items after arrival at the Dental laboratory. Dental impressions can be cross-contaminated by patient’s saliva and blood, which then cross-infect the dental casts poured from the impressions. The present study was carried out to evaluate the knowledge and the practice of infection control of dental impressions among dental technicians in Tripoli, Libya. Methods. This study was based on questionnaire that designed to cover different aspects of cross-infection control in the dental clinic. The questionnaire consists of 10 closed end question and 3 yes, no question. Results. The response rate was 85%. The questionnaire showed that almost 32.9% of the dental technicians did not have instructions related to disinfection in the dental lab. Upon receipt of dental impressions, the majority (80.5%) reported always rinsing them with water only. Moreover, about 7.8% of the dental technicians reported never disinfecting dental impressions and about 16.9% reported that they sometimes disinfected impressions. In the labs were the disinfection applied, 12% of the dental labs used spray disinfection (without water) and also 12% of dental technicians used immersion disinfection (without water). Conclusion. The findings of this study show that practices and awareness of dental technicians regarding infection control are less than ideal, moreover there is lack of communication between dentists and dental technicians so should increase awareness and establishing educational programs for both dentists and dental technicians to decrease the risk of transmission of diseases in dental laboratories.
- 1 July 2018
- Published by Elsevier in Chemosphere
- Vol. 203, 514-520
Dry and wet ozonation of denim: Degradation products, reaction mechanism, toxicity and cytotoxicity assessment
- 1 July 2018
- Published by Elsevier in Chemosphere
- Vol. 203, 514-520
Dry and wet ozonation of denim: Degradation products, reaction mechanism, toxicity and cytotoxicity assessment
- 11 November 2015
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 38 (3) , 175-180
Study of Parameters Affecting Dry and Wet Ozone Bleaching of Denim Fabric
The present research is related to a recent eco-friendly technology in a denim laundry that relies on ozone oxidation of indigo. In this work, denim fabric was treated with ozone at different values of ozone concentration, moisture content and time of exposure to ozone. The fading increased with the increase of the various mentioned factors. Residual products of the indigo oxidation by ozone, the cause of the yellowing observed on the surface of the fabric were identified through spectrophotometric measurements, pH variation and FTIR analysis. Ozone effect on mechanical properties of the fabric was studied through the measurement of ultimate tensile strength.
- 11 November 2015
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 38 (3) , 175-180
Study of Parameters Affecting Dry and Wet Ozone Bleaching of Denim Fabric
The present research is related to a recent eco-friendly technology in a denim laundry that relies on ozone oxidation of indigo. In this work, denim fabric was treated with ozone at different values of ozone concentration, moisture content and time of exposure to ozone. The fading increased with the increase of the various mentioned factors. Residual products of the indigo oxidation by ozone, the cause of the yellowing observed on the surface of the fabric were identified through spectrophotometric measurements, pH variation and FTIR analysis. Ozone effect on mechanical properties of the fabric was studied through the measurement of ultimate tensile strength.