Nahid Chegeni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nahid Chegeni has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
Amir Danyaei
Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
6 shared publications- Marziyeh Tahmasbi
Department of Radiologic Technology, School of Allied Medical Sciences Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran
5 shared publications Mohammad Javad Tahmasebi Birgani
Department of Medical Physics, Medicine Faculty, Ahvaz, Iran
5 shared publicationsAli Bagheri
Department of Radiation Oncology, Faculty of Medicine, Golestan Hospital, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, Iran
3 shared publications- Ali Bagheri
Interventional Radiotherapy Ward, Department of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
3 shared publications - Amir Hossein Karimi
Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
3 shared publications
Latest Publications
- 17 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105892
Radiation-induced erectile dysfunction in prostate cancer: A systematic review of pathophysiology, clinical radiobiology, and predictive modeling
- 17 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105892
Radiation-induced erectile dysfunction in prostate cancer: A systematic review of pathophysiology, clinical radiobiology, and predictive modeling
- Open Access
- 5 June 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
GATE Monte Carlo evaluation of cellular dosimetry for 119Sb in targeted radionuclide therapy
Background: This study evaluates the cellular dosimetry of Antimony-119 ( 119 Sb) as a candidate for targeted radionuclide therapy (TRT), using Monte Carlo simulations with the GATE toolkit. The goal is to assess the microdosimetric characteristics of 119 Sb as an Auger and Internal conversion electron emitter and compare its performance with other clinically relevant radionuclides— 177 Lu, 125 I, 123 I, and 103 Pd—across different cellular geometries and emission spectra. Methods: Monte Carlo simulations were performed using the GATE toolkit to model energy deposition at the cellular level. Two cell geometries were considered: one with a centrally located nucleus and another with the nucleus adjacent to the cell membrane, reflecting real biological diversity. S-values (absorbed dose per decay) were calculated for three possible locations of radioactivity (nucleus, cytoplasm, and cell membrane). Three emission spectra and two physics models were used to ensure robust results. Simulations were benchmarked against established dosimetry models (MIRDcell, PENELOPE, and Geant4). Results: 119 Sb delivered the highest and most localized dose to the cell nucleus, particularly when radioactivity was at the cell membrane, outperforming the other radionuclides tested. Its S-values were up to five times higher than 177 Lu and four times higher than 125 I in certain configurations. This effect remained strong even when the nucleus was off-center, suggesting 119 Sb’s effectiveness is independent to nucleus locations diversities. Auger and Coster-Kronig electrons dominated the energy deposition for most isotopes in single cell configurations, while internal conversion electrons contributed significantly for 119 Sb in the cytoplasmic and membrane configurations. Conclusions: 119 Sb is a promising candidate for TRT of micrometastases and single cancer cells due to its high and stable S-values, especially when radioactivity is localized at the cell membrane. Its dosimetric stability across nucleus positions makes it particularly suitable for therapeutic applications where cellular morphology varies. However, production and radiolabeling challenges may limit its clinical adoption.
- 5 June 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Open AccessGATE Monte Carlo evaluation of cellular dosimetry for 119Sb in targeted radionuclide therapy
Background: This study evaluates the cellular dosimetry of Antimony-119 ( 119 Sb) as a candidate for targeted radionuclide therapy (TRT), using Monte Carlo simulations with the GATE toolkit. The goal is to assess the microdosimetric characteristics of 119 Sb as an Auger and Internal conversion electron emitter and compare its performance with other clinically relevant radionuclides— 177 Lu, 125 I, 123 I, and 103 Pd—across different cellular geometries and emission spectra. Methods: Monte Carlo simulations were performed using the GATE toolkit to model energy deposition at the cellular level. Two cell geometries were considered: one with a centrally located nucleus and another with the nucleus adjacent to the cell membrane, reflecting real biological diversity. S-values (absorbed dose per decay) were calculated for three possible locations of radioactivity (nucleus, cytoplasm, and cell membrane). Three emission spectra and two physics models were used to ensure robust results. Simulations were benchmarked against established dosimetry models (MIRDcell, PENELOPE, and Geant4). Results: 119 Sb delivered the highest and most localized dose to the cell nucleus, particularly when radioactivity was at the cell membrane, outperforming the other radionuclides tested. Its S-values were up to five times higher than 177 Lu and four times higher than 125 I in certain configurations. This effect remained strong even when the nucleus was off-center, suggesting 119 Sb’s effectiveness is independent to nucleus locations diversities. Auger and Coster-Kronig electrons dominated the energy deposition for most isotopes in single cell configurations, while internal conversion electrons contributed significantly for 119 Sb in the cytoplasmic and membrane configurations. Conclusions: 119 Sb is a promising candidate for TRT of micrometastases and single cancer cells due to its high and stable S-values, especially when radioactivity is localized at the cell membrane. Its dosimetric stability across nucleus positions makes it particularly suitable for therapeutic applications where cellular morphology varies. However, production and radiolabeling challenges may limit its clinical adoption.
- Open Access
- 1 January 2026
- Published by Wiley in Applied Computational Intelligence and Soft Computing
- Vol. 2026 (1)
EvoMed‐Net: A Sequential Multi‐CNN Ensemble for Brain Tumor Analysis in MRI
Improving patient outcomes depends on the early and precise detection of brain tumors. This study proposes EvoMed‐Net, a sequential ensemble framework comprising four independent convolutional neural networks—ZFNet, AlexNet, VGG16, and ResNet50—to automatically classify and segment brain tumors using magnetic resonance imaging (MRI). The first dataset included 8199 MRI scans for multiclass tumor type classification, while a second dataset of 3064 scans with corresponding masks was used for tumor detection and segmentation. Results from the four CNN models were combined using decision‐level fusion techniques such as majority voting and probabilistic averaging to enhance diagnostic robustness. The individual CNN models achieved precision, recall, and F1 scores ranging from 0.96 to 0.97, while the ensemble approach achieved an overall classification accuracy of 99%. The proposed averaged aggregation consensus (AAC) strategy generated a more stable ensemble decision through probability aggregation and improved classification consistency. Notable class separability was observed in ZFNet, and ResNet50 obtained the highest overlap scores in the segmentation task. The integrated detection–segmentation framework demonstrated reliable capability in accurately delineating small tumor regions and reducing manual intervention, advancing toward intelligent, noninvasive diagnostic systems. These findings confirm that the sequential integration of models provides a reliable and accurate method for MRI‐based brain tumor assessment, serving as an effective decision support tool in clinical diagnostics.
- 1 January 2026
- Published by Wiley in Applied Computational Intelligence and Soft Computing
- Vol. 2026 (1)
Open AccessEvoMed‐Net: A Sequential Multi‐CNN Ensemble for Brain Tumor Analysis in MRI
Improving patient outcomes depends on the early and precise detection of brain tumors. This study proposes EvoMed‐Net, a sequential ensemble framework comprising four independent convolutional neural networks—ZFNet, AlexNet, VGG16, and ResNet50—to automatically classify and segment brain tumors using magnetic resonance imaging (MRI). The first dataset included 8199 MRI scans for multiclass tumor type classification, while a second dataset of 3064 scans with corresponding masks was used for tumor detection and segmentation. Results from the four CNN models were combined using decision‐level fusion techniques such as majority voting and probabilistic averaging to enhance diagnostic robustness. The individual CNN models achieved precision, recall, and F1 scores ranging from 0.96 to 0.97, while the ensemble approach achieved an overall classification accuracy of 99%. The proposed averaged aggregation consensus (AAC) strategy generated a more stable ensemble decision through probability aggregation and improved classification consistency. Notable class separability was observed in ZFNet, and ResNet50 obtained the highest overlap scores in the segmentation task. The integrated detection–segmentation framework demonstrated reliable capability in accurately delineating small tumor regions and reducing manual intervention, advancing toward intelligent, noninvasive diagnostic systems. These findings confirm that the sequential integration of models provides a reliable and accurate method for MRI‐based brain tumor assessment, serving as an effective decision support tool in clinical diagnostics.
- Open Access
- 27 November 2025
- Published by Springer Nature in Cell Biology and Toxicology
- Vol. 41 (1) , 158
Copper-cysteamine nanoparticles in cancer treatment: a systematic review
Copper-cysteamine nanoparticles (Cu-Cy NPs) represent an innovative approach for cancer therapy due to their unique ability to be activated by multiple physical and chemical stimuli. This review systematically evaluates studies investigating Cu-Cy NPs in combination with chemical agents and diverse energy sources, including X-rays, UV light, microwaves, and ultrasound. A comprehensive literature search in PubMed, Scopus, and Web of Science up to August 2025 identified 18 relevant studies encompassing both in vitro and in vivo experiments. Across these studies, Cu-Cy NPs consistently suppressed tumor growth and triggered cancer cell death by generating reactive oxygen species (ROS) and enhanced therapeutic effects when combined with co-treatments such as disulfiram, potassium iodide, and other adjunct therapies. The multi-modal activation of Cu-Cy NPs, along with their ability to enhance existing therapeutic approaches, demonstrates a novel strategy in cancer treatment that integrates chemical and physical mechanisms for maximal efficacy. These findings underscore the nanoparticles’ potential to transform current oncology strategies, offering targeted, versatile, and personalized therapeutic options. Continued investigation is essential to fully elucidate their mechanisms, optimize treatment protocols, and translate these promising preclinical results into safe and effective clinical applications. Graphical Abstract
- 27 November 2025
- Published by Springer Nature in Cell Biology and Toxicology
- Vol. 41 (1) , 158
Open AccessCopper-cysteamine nanoparticles in cancer treatment: a systematic review
Copper-cysteamine nanoparticles (Cu-Cy NPs) represent an innovative approach for cancer therapy due to their unique ability to be activated by multiple physical and chemical stimuli. This review systematically evaluates studies investigating Cu-Cy NPs in combination with chemical agents and diverse energy sources, including X-rays, UV light, microwaves, and ultrasound. A comprehensive literature search in PubMed, Scopus, and Web of Science up to August 2025 identified 18 relevant studies encompassing both in vitro and in vivo experiments. Across these studies, Cu-Cy NPs consistently suppressed tumor growth and triggered cancer cell death by generating reactive oxygen species (ROS) and enhanced therapeutic effects when combined with co-treatments such as disulfiram, potassium iodide, and other adjunct therapies. The multi-modal activation of Cu-Cy NPs, along with their ability to enhance existing therapeutic approaches, demonstrates a novel strategy in cancer treatment that integrates chemical and physical mechanisms for maximal efficacy. These findings underscore the nanoparticles’ potential to transform current oncology strategies, offering targeted, versatile, and personalized therapeutic options. Continued investigation is essential to fully elucidate their mechanisms, optimize treatment protocols, and translate these promising preclinical results into safe and effective clinical applications. Graphical Abstract
- Open Access
- 1 November 2025
- Published by Taylor & Francis in Cancer Management and Research
- Vol. ume 17, 2821-2836
Folic Acid, Folate Conjugates and Folate Receptors: Novel Applications in Imaging of Cancer and Inflammation-Related Conditions
Selective delivery of imaging agents to target cells remains a major challenge for molecular imaging and targeted therapy. Folate-based targeting leverages the differential expression of folate receptors (FRs), which are frequently overexpressed in various malignancies and in activated macrophages compared with most normal tissues, to mediate selective cellular uptake. Folate and folate-conjugates offer several advantages for targeted delivery: 1) restricted normal-tissue distribution of FRs, 2) high affinity binding to FRs, and 3) straightforward conjugation chemistry that enables linkage to both therapeutic and imaging moieties. In this narrative review, we summarize recent advances in FR-targeted imaging across multiple modalities (PET, SPECT, MRI, and optical imaging), discuss strategies for probe design and pharmacokinetic optimization, and highlight translational progress from preclinical studies to early clinical applications. We also review emerging applications of folate-mediated delivery for gene therapy and immune modulation, and we identify remaining challenges including probe specificity, background uptake, and clinical validation and outline directions for future research and clinical translation.
- 1 November 2025
- Published by Taylor & Francis in Cancer Management and Research
- Vol. ume 17, 2821-2836
Open AccessFolic Acid, Folate Conjugates and Folate Receptors: Novel Applications in Imaging of Cancer and Inflammation-Related Conditions
Selective delivery of imaging agents to target cells remains a major challenge for molecular imaging and targeted therapy. Folate-based targeting leverages the differential expression of folate receptors (FRs), which are frequently overexpressed in various malignancies and in activated macrophages compared with most normal tissues, to mediate selective cellular uptake. Folate and folate-conjugates offer several advantages for targeted delivery: 1) restricted normal-tissue distribution of FRs, 2) high affinity binding to FRs, and 3) straightforward conjugation chemistry that enables linkage to both therapeutic and imaging moieties. In this narrative review, we summarize recent advances in FR-targeted imaging across multiple modalities (PET, SPECT, MRI, and optical imaging), discuss strategies for probe design and pharmacokinetic optimization, and highlight translational progress from preclinical studies to early clinical applications. We also review emerging applications of folate-mediated delivery for gene therapy and immune modulation, and we identify remaining challenges including probe specificity, background uptake, and clinical validation and outline directions for future research and clinical translation.
- Open Access
- 15 September 2025
- Published by MDPI AG in Preprints.org
Synergistic Photodynamic Therapy: Copper-Cysteamine Nanoparticles and UV Radiation Suppress Melanoma (A375)
Conventional melanoma cancer treatments, including surgery, radiotherapy, and chemotherapy, are often costly and associated with adverse effects such as tissue damage, pigmentation changes, pain, inflammation, and prolonged recovery. Hence, this study explores photodynamic therapy (PDT) using copper-cysteamine nanoparticles (Cu-Cy NPs) combined with UVA irradiation as a potential approach to enhance therapeutic efficacy while reducing side effects. A375 melanoma cells were treated with Cu-Cy NPs (3 μg/mL) and exposed to UVA light for 2 or 10 minutes. Cell viability, ROS generation, and apoptosis were evaluated using MTT, NBT, and flow cytometry assays, respectively. Neither Cu-Cy NPs nor UVA irradiation alone significantly increased ROS or apoptosis. However, their combination for 10 minutes synergistically elevated ROS levels and induced pronounced apoptosis, with cell death comparable to cisplatin-treated positive controls. Shorter UVA exposure (2 minutes) did not produce a significant effect, indicating the critical role of irradiation duration. Comparative analysis across cell lines confirmed that A375 cells exhibit high sensitivity to UVA-mediated PDT, highlighting cell-line-specific differences in response. The combination of UVA irradiation and Cu-Cy NPs effectively induces apoptosis in melanoma cells, highlighting a synergistic effect that surpasses individual treatments. This approach represents a potential alternative or adjunct to conventional therapies, with the advantage of minimizing adverse effects.
- 15 September 2025
- Published by MDPI AG in Preprints.org
Open AccessSynergistic Photodynamic Therapy: Copper-Cysteamine Nanoparticles and UV Radiation Suppress Melanoma (A375)
Conventional melanoma cancer treatments, including surgery, radiotherapy, and chemotherapy, are often costly and associated with adverse effects such as tissue damage, pigmentation changes, pain, inflammation, and prolonged recovery. Hence, this study explores photodynamic therapy (PDT) using copper-cysteamine nanoparticles (Cu-Cy NPs) combined with UVA irradiation as a potential approach to enhance therapeutic efficacy while reducing side effects. A375 melanoma cells were treated with Cu-Cy NPs (3 μg/mL) and exposed to UVA light for 2 or 10 minutes. Cell viability, ROS generation, and apoptosis were evaluated using MTT, NBT, and flow cytometry assays, respectively. Neither Cu-Cy NPs nor UVA irradiation alone significantly increased ROS or apoptosis. However, their combination for 10 minutes synergistically elevated ROS levels and induced pronounced apoptosis, with cell death comparable to cisplatin-treated positive controls. Shorter UVA exposure (2 minutes) did not produce a significant effect, indicating the critical role of irradiation duration. Comparative analysis across cell lines confirmed that A375 cells exhibit high sensitivity to UVA-mediated PDT, highlighting cell-line-specific differences in response. The combination of UVA irradiation and Cu-Cy NPs effectively induces apoptosis in melanoma cells, highlighting a synergistic effect that surpasses individual treatments. This approach represents a potential alternative or adjunct to conventional therapies, with the advantage of minimizing adverse effects.
- 3 April 2025
- Published by Elsevier in Brachytherapy
- Vol. 24 (4) , 543-549
The impact of inherent dose heterogeneity of brachytherapy on calculating iso-effective dose-fractionation regimens for nonmelanoma skin cancers
- 3 April 2025
- Published by Elsevier in Brachytherapy
- Vol. 24 (4) , 543-549
The impact of inherent dose heterogeneity of brachytherapy on calculating iso-effective dose-fractionation regimens for nonmelanoma skin cancers
- Open Access
- 31 March 2025
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 24
Optimization of the Dose-Volume Effect Parameter “a” in EUD-Based TCP Models for Breast Cancer Radiotherapy
Introduction: Radiotherapy treatment plans traditionally rely on physical indices like Dose-volume histograms and spatial dose distributions. While these metrics assess dose delivery, they lack consideration for the biological effects on tumors and healthy tissues. To address this, radiobiological models like tumor control probability (TCP) and Normal tissue complications probability (NTCP) are increasingly incorporated to evaluate treatment efficacy and potential complications. This study aimed to assess the predictive power of radiobiological models for TCP in breast cancer radiotherapy and provide insights into the model selection and parameter optimization. Methods: In this retrospective observational study, two commonly used models, the Linear-Poisson and Equivalent uniform dose (EUD)-based models, were employed to calculate TCP for 30 patients. Different radiobiological parameter sets were investigated, including established sets from literature (G 1 and G 2 ) and set with an optimized “a” parameter derived from clinical trial data (a 1 and a 2 ). Model predictions were compared with clinical outcomes from the START trials. Results: The Linear-Poisson model with es lished parameter sets from the literature demonstrated good agreement with clinical data. The standard EUD-based model (a = -7.2) significantly underestimated TCP. While both models exhibited some level of independence from the specific parameter sets (G 1 vs. G 2 ), the EUD-based model was susceptible to the “a” parameter value. Optimization suggests a more accurate “a” value closer to -2.57 and -5.65. Conclusion: This study emphasizes the importance of clinically relevant radiobiological parameters for accurate TCP prediction and optimizing the “a” parameter in the EUD-based model based on clinical data (a1 and a2) improved its predictive accuracy significantly.
- 31 March 2025
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 24
Open AccessOptimization of the Dose-Volume Effect Parameter “a” in EUD-Based TCP Models for Breast Cancer Radiotherapy
Introduction: Radiotherapy treatment plans traditionally rely on physical indices like Dose-volume histograms and spatial dose distributions. While these metrics assess dose delivery, they lack consideration for the biological effects on tumors and healthy tissues. To address this, radiobiological models like tumor control probability (TCP) and Normal tissue complications probability (NTCP) are increasingly incorporated to evaluate treatment efficacy and potential complications. This study aimed to assess the predictive power of radiobiological models for TCP in breast cancer radiotherapy and provide insights into the model selection and parameter optimization. Methods: In this retrospective observational study, two commonly used models, the Linear-Poisson and Equivalent uniform dose (EUD)-based models, were employed to calculate TCP for 30 patients. Different radiobiological parameter sets were investigated, including established sets from literature (G 1 and G 2 ) and set with an optimized “a” parameter derived from clinical trial data (a 1 and a 2 ). Model predictions were compared with clinical outcomes from the START trials. Results: The Linear-Poisson model with es lished parameter sets from the literature demonstrated good agreement with clinical data. The standard EUD-based model (a = -7.2) significantly underestimated TCP. While both models exhibited some level of independence from the specific parameter sets (G 1 vs. G 2 ), the EUD-based model was susceptible to the “a” parameter value. Optimization suggests a more accurate “a” value closer to -2.57 and -5.65. Conclusion: This study emphasizes the importance of clinically relevant radiobiological parameters for accurate TCP prediction and optimizing the “a” parameter in the EUD-based model based on clinical data (a1 and a2) improved its predictive accuracy significantly.
- Open Access
- 29 October 2024
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 23, e23
Radiobiological evaluation of hypo-fractionated breast cancer radiotherapy regimens in comparison with conventional approaches
Purpose: This study compares tumor control probability (TCP) and normal tissue complication probability (NTCP) across different hypo-fractionated (HypoRT) and conventional breast radiotherapy regimens using radiobiological models. Materials and methods: Computed tomography data from 30 patients with left breast-conserving surgery were used to evaluate three HypoRT regimens (39 Gy and 41·6 Gy in 13 fractions, and 40 Gy in 15 fractions) and a conventional regimen (50 Gy in 25 fractions). Dose-volume histograms (DVHs) were extracted for radiobiological calculations using Equivalent Uniform Dose (EUD) and Poisson models for TCP, and EUD and LKB (Lyman-Kutcher-Burman) models for NTCP. Results: Conventional treatment achieved significantly higher TCP (95%) than all HypoRT regimens (p < 0·001), with no significant differences between HypoRT regimens (p > 0·05. The 39 Gy/13 fraction regimen showed the lowest lung NTCP (p < 0·05). HypoRT regimens had significantly lower NTCP for the lungs and heart compared to the conventional regimen (p < 0·01). TCP and NTCP values from Poisson and LKB models were higher than those from the EUD model (p < 0·01). Conclusion: HypoRT regimens reduced NTCP, with the lowest values in the regime of 39 Gy/13 fractions regimen, though the conventional regimen had higher TCP.
- 29 October 2024
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 23, e23
Open AccessRadiobiological evaluation of hypo-fractionated breast cancer radiotherapy regimens in comparison with conventional approaches
Purpose: This study compares tumor control probability (TCP) and normal tissue complication probability (NTCP) across different hypo-fractionated (HypoRT) and conventional breast radiotherapy regimens using radiobiological models. Materials and methods: Computed tomography data from 30 patients with left breast-conserving surgery were used to evaluate three HypoRT regimens (39 Gy and 41·6 Gy in 13 fractions, and 40 Gy in 15 fractions) and a conventional regimen (50 Gy in 25 fractions). Dose-volume histograms (DVHs) were extracted for radiobiological calculations using Equivalent Uniform Dose (EUD) and Poisson models for TCP, and EUD and LKB (Lyman-Kutcher-Burman) models for NTCP. Results: Conventional treatment achieved significantly higher TCP (95%) than all HypoRT regimens (p < 0·001), with no significant differences between HypoRT regimens (p > 0·05. The 39 Gy/13 fraction regimen showed the lowest lung NTCP (p < 0·05). HypoRT regimens had significantly lower NTCP for the lungs and heart compared to the conventional regimen (p < 0·01). TCP and NTCP values from Poisson and LKB models were higher than those from the EUD model (p < 0·01). Conclusion: HypoRT regimens reduced NTCP, with the lowest values in the regime of 39 Gy/13 fractions regimen, though the conventional regimen had higher TCP.