Amir Hossein Karimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amir Hossein Karimi has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Ghazale Geraily
Tehran University of Medical Sciences
9 shared publications Iraj Jabbari
Department of Nuclear Engineering, Faculty of Physics, University of Isfahan, Isfahan, Iran
5 shared publications- Hector Rene Vega-Carrillo
Universidad Autónoma de Zacatecas
3 shared publications - Indra J. Das
Northwestern University Feinberg School of Medicine
3 shared publications - Nahid Chegeni
Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
3 shared publications Saeedeh Moharramkhani
Tehran University of Medical Sciences
3 shared publications
Latest Publications
- 11 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055012
Discrepancy between collapsed cone and Monte Carlo algorithms in lung inhomogeneity correction
Stereotactic body radiation therapy (SBRT) is a well-established standard of treatment for non-small cell lung cancer patients. However, SBRT is a double-edged sword and a high degree of accuracy is required for dose calculations. In the presence of inhomogeneity, it should be below 3% and depends strongly on the accuracy of the algorithm used for dose calculation in treatment planning system (TPS). The aim of this study is to evaluate the accuracy of collapsed cone (CC) algorithm for dose calculation in the presence of lung inhomogeneity compared to the Monte Carlo (MC) algorithm as the reference. The study conducted on a wide range of photon fields from 0.5 × 0.5 cm 2 to 10 × 10 cm 2 . Monaco® TPS equipped with CC and MC algorithms in 6 MV, 10 MV, and 18 MV photons was employed and the inhomogeneity correction factor and PPDs were calculated inside an in-house inhomogeneous phantom. Finally, the results were compared between two algorithms. For 6 MV photons, gamma index pass rate (GIPR) with (2 mm, 3%) criteria in a 0.5 × 0.5 cm 2 field is only 71.3%. The CC algorithm will not be able to confidently reproduce the PDDs in this field. For 1 × 1 cm 2 , 2 × 2 cm 2 , and 3 × 3 cm 2 fields, the accuracy of the CC algorithm can increase to above 98%. For SBRT of small lung lesions, the results recommend increasing the minimum segment width to >0.5 cm in IMRT plans if CC algorithm is used. Independent of field size, the accuracy of CC algorithm decreases with increasing energy. For 10 and 18 MV photons, average GIPR under (2 mm, 3%) criteria was 97.9% and 92.0%, respectively, which are not of clinical interest.
- 11 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055012
Discrepancy between collapsed cone and Monte Carlo algorithms in lung inhomogeneity correction
Stereotactic body radiation therapy (SBRT) is a well-established standard of treatment for non-small cell lung cancer patients. However, SBRT is a double-edged sword and a high degree of accuracy is required for dose calculations. In the presence of inhomogeneity, it should be below 3% and depends strongly on the accuracy of the algorithm used for dose calculation in treatment planning system (TPS). The aim of this study is to evaluate the accuracy of collapsed cone (CC) algorithm for dose calculation in the presence of lung inhomogeneity compared to the Monte Carlo (MC) algorithm as the reference. The study conducted on a wide range of photon fields from 0.5 × 0.5 cm 2 to 10 × 10 cm 2 . Monaco® TPS equipped with CC and MC algorithms in 6 MV, 10 MV, and 18 MV photons was employed and the inhomogeneity correction factor and PPDs were calculated inside an in-house inhomogeneous phantom. Finally, the results were compared between two algorithms. For 6 MV photons, gamma index pass rate (GIPR) with (2 mm, 3%) criteria in a 0.5 × 0.5 cm 2 field is only 71.3%. The CC algorithm will not be able to confidently reproduce the PDDs in this field. For 1 × 1 cm 2 , 2 × 2 cm 2 , and 3 × 3 cm 2 fields, the accuracy of the CC algorithm can increase to above 98%. For SBRT of small lung lesions, the results recommend increasing the minimum segment width to >0.5 cm in IMRT plans if CC algorithm is used. Independent of field size, the accuracy of CC algorithm decreases with increasing energy. For 10 and 18 MV photons, average GIPR under (2 mm, 3%) criteria was 97.9% and 92.0%, respectively, which are not of clinical interest.
- Open Access
- 24 August 2026
- Published by Elsevier in SSRN Electronic Journal
Performance of Monte Carlo and Collapsed Cone Algorithms for Dose Calculation in Lung Stereotactic Body Radiation Therapy: Accuracy in Small Photon Fields
Background and Objective: Effective radiation therapy hinges on accurate dosimetry, especially in stereotactic body radiation therapy (SBRT). Treatment planning system (TPS) must accurately calculate doses, but uncertainties arise with lung inhomogeneity. Accuracy of Monte Carlo (MC) and Collapsed Cone (CC) algorithms have been less studied for small photon fields.Methods: This study compared MC and CC point doses with EBT3 film measurements in homogeneous and inhomogeneous phantoms across field sizes (0.5×0.5 cm² to 10×10 cm²) and photon energies (6, 10, and 18 MV). Inhomogeneity correction factors were compared between the algorithms and measurements at depths of dmax, 5, 10, 15, and 20 cm for all energies and field sizes.Results: Both MC and CC algorithms are expected to achieve above 95% accuracy in the water. However, for a very small field of 0.5×0.5 cm², the MC algorithm may be associated with on average 4.7%, 9.5%, and 10.7% dose underestimation for 6, 10, and 18 MV photons, respectively. If the CC algorithm was used in this case, it represented 13.4%, 12.0%, and 23.1%, respectively. In the inhomogeneous phantom, for field sizes ≥ 5×5 cm², the dose calculation uncertainty with the MC calculation was within 5%. As the field size decreases and the depth within the inhomogeneity increases, the value rises dramatically to ~15% and ~30% for MC and CC algorithms, respectively.Conclusions: CC algorithm should be avoided for small lesions, even outside the lung. MC algorithm is recommended for dose calculations in lung SBRT with caution, increasing the minimum IMRT/VMAT segment width to more than 0.5 cm.
- 24 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPerformance of Monte Carlo and Collapsed Cone Algorithms for Dose Calculation in Lung Stereotactic Body Radiation Therapy: Accuracy in Small Photon Fields
Background and Objective: Effective radiation therapy hinges on accurate dosimetry, especially in stereotactic body radiation therapy (SBRT). Treatment planning system (TPS) must accurately calculate doses, but uncertainties arise with lung inhomogeneity. Accuracy of Monte Carlo (MC) and Collapsed Cone (CC) algorithms have been less studied for small photon fields.Methods: This study compared MC and CC point doses with EBT3 film measurements in homogeneous and inhomogeneous phantoms across field sizes (0.5×0.5 cm² to 10×10 cm²) and photon energies (6, 10, and 18 MV). Inhomogeneity correction factors were compared between the algorithms and measurements at depths of dmax, 5, 10, 15, and 20 cm for all energies and field sizes.Results: Both MC and CC algorithms are expected to achieve above 95% accuracy in the water. However, for a very small field of 0.5×0.5 cm², the MC algorithm may be associated with on average 4.7%, 9.5%, and 10.7% dose underestimation for 6, 10, and 18 MV photons, respectively. If the CC algorithm was used in this case, it represented 13.4%, 12.0%, and 23.1%, respectively. In the inhomogeneous phantom, for field sizes ≥ 5×5 cm², the dose calculation uncertainty with the MC calculation was within 5%. As the field size decreases and the depth within the inhomogeneity increases, the value rises dramatically to ~15% and ~30% for MC and CC algorithms, respectively.Conclusions: CC algorithm should be avoided for small lesions, even outside the lung. MC algorithm is recommended for dose calculations in lung SBRT with caution, increasing the minimum IMRT/VMAT segment width to more than 0.5 cm.
- Open Access
- 21 August 2026
- Published by Elsevier in SSRN Electronic Journal
Monte Carlo Investigation of Electron Contamination and Dosimetric Characteristics of a Novel Ti2V0.07Cu97.93 Target for a Varian 2100C/D Medical Linear Accelerator
Introduction: Photon beams produced by medical linear accelerators are accompanied by a small fraction of contaminating electrons generated through photon interactions within the accelerator head, surrounding air, and treatment phantom. These electrons can increase the surface dose and reduce the skin‑sparing advantage of megavoltage photon beamsObjectives: In this study, the dosimetric characteristics of a novel target alloy (Ti2V0.07Cu97.93) were investigated and compared with those of a conventional tungsten/copper (W/Cu) target in a medical linear accelerator operating at a nominal electron energy of 18.1 MeV. Materials and Methods: A detailed Monte Carlo model of a Varian 2100 C/D linac head was developed using the MCNPX 2.7 code. The model was validated by comparing calculated percent depth dose (PDD) curves and beam profiles with experimental measurements using the gamma index method with 2%/ 2 mm criteria. Key dosimetric parameters including beam profile flatness, symmetry, beam quality index (TPR20/10), photon fluence, and electron contamination were evaluated. Result: The results show that the new target provides comparable photon beam quality while slightly modifying beam profile characteristics. However, the Ti–V–Cu alloy target produces higher electron contamination, leading to an increased surface and buildup dose compared with the conventional target. Despite this effect, the photon beam quality index remains similar for both configurations. Conclusion: These findings provide insight into the potential advantages and limitations of the proposed target material and highlight considerations for its future implementation in medical linear accelerators.
- 21 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMonte Carlo Investigation of Electron Contamination and Dosimetric Characteristics of a Novel Ti2V0.07Cu97.93 Target for a Varian 2100C/D Medical Linear Accelerator
Introduction: Photon beams produced by medical linear accelerators are accompanied by a small fraction of contaminating electrons generated through photon interactions within the accelerator head, surrounding air, and treatment phantom. These electrons can increase the surface dose and reduce the skin‑sparing advantage of megavoltage photon beamsObjectives: In this study, the dosimetric characteristics of a novel target alloy (Ti2V0.07Cu97.93) were investigated and compared with those of a conventional tungsten/copper (W/Cu) target in a medical linear accelerator operating at a nominal electron energy of 18.1 MeV. Materials and Methods: A detailed Monte Carlo model of a Varian 2100 C/D linac head was developed using the MCNPX 2.7 code. The model was validated by comparing calculated percent depth dose (PDD) curves and beam profiles with experimental measurements using the gamma index method with 2%/ 2 mm criteria. Key dosimetric parameters including beam profile flatness, symmetry, beam quality index (TPR20/10), photon fluence, and electron contamination were evaluated. Result: The results show that the new target provides comparable photon beam quality while slightly modifying beam profile characteristics. However, the Ti–V–Cu alloy target produces higher electron contamination, leading to an increased surface and buildup dose compared with the conventional target. Despite this effect, the photon beam quality index remains similar for both configurations. Conclusion: These findings provide insight into the potential advantages and limitations of the proposed target material and highlight considerations for its future implementation in medical linear accelerators.
- 27 April 2026
- Published by Elsevier in Radiation Measurements
- Vol. 195
High-dose-rate electron total skin therapy: A comprehensive dosimetric study on Stanford technique
- 27 April 2026
- Published by Elsevier in Radiation Measurements
- Vol. 195
High-dose-rate electron total skin therapy: A comprehensive dosimetric study on Stanford technique
- 20 June 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (4) , 045049
Dose equivalent consideration from neutron contamination in modified radiotherapy vault: a Monte Carlo study
Laminated barriers incorporating metal sheets provide effective protection for space-restricted radiotherapy centers. This study aimed to assess photoneutron contamination in smaller vaults protected by different compositions of multilayer barriers during simulated pelvic radiotherapy with 18 MV photon beams. Monte Carlo Simulations of 18 MV LINAC (Varian 2100 C/D) and Medical Internal Radiation Dose (MIRD) phantom were used to assess photoneutron contamination within reconstructed vaults incorporating different combinations of metal sheet and borated polyethylene (BPE) during pelvic radiotherapy. The findings highlight a 3.27 and 2.91 times increase in ambient neutron dose H n * (10) along the maze of reconstructed vaults that use lead and steel sheets, respectively, compared to concrete. The H n * (10) outside the treatment room increased after incorporating a metal sheet, but it remained within the permissible limit of 20 μSv/week for uncontrolled areas adjacent to the LINAC bunker, even with a workload of 1000Gy/week. Neutron equivalent doses in the patient’s organs ranged from 0.22 to 0.96 mSv Gy−1. There is no notable distinction in the organ’s neutron equivalent dose, fatal cancer risk, secondary radiation-induced cancer risk, and cancer mortality for various laminated barrier compositions. Furthermore, the use of metal sheets for vault wall reconstruction keeps the variation in cancer risk induced by photoneutrons below 6%, while risks of fatal cancer and cancer mortality vary less than 11%. While the metal portion of the laminated barrier raises the neutron dose, the addition of a BPE plate reduces concerns of increased effective dose and secondary malignancy risk.
- 20 June 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (4) , 045049
Dose equivalent consideration from neutron contamination in modified radiotherapy vault: a Monte Carlo study
Laminated barriers incorporating metal sheets provide effective protection for space-restricted radiotherapy centers. This study aimed to assess photoneutron contamination in smaller vaults protected by different compositions of multilayer barriers during simulated pelvic radiotherapy with 18 MV photon beams. Monte Carlo Simulations of 18 MV LINAC (Varian 2100 C/D) and Medical Internal Radiation Dose (MIRD) phantom were used to assess photoneutron contamination within reconstructed vaults incorporating different combinations of metal sheet and borated polyethylene (BPE) during pelvic radiotherapy. The findings highlight a 3.27 and 2.91 times increase in ambient neutron dose H n * (10) along the maze of reconstructed vaults that use lead and steel sheets, respectively, compared to concrete. The H n * (10) outside the treatment room increased after incorporating a metal sheet, but it remained within the permissible limit of 20 μSv/week for uncontrolled areas adjacent to the LINAC bunker, even with a workload of 1000Gy/week. Neutron equivalent doses in the patient’s organs ranged from 0.22 to 0.96 mSv Gy−1. There is no notable distinction in the organ’s neutron equivalent dose, fatal cancer risk, secondary radiation-induced cancer risk, and cancer mortality for various laminated barrier compositions. Furthermore, the use of metal sheets for vault wall reconstruction keeps the variation in cancer risk induced by photoneutrons below 6%, while risks of fatal cancer and cancer mortality vary less than 11%. While the metal portion of the laminated barrier raises the neutron dose, the addition of a BPE plate reduces concerns of increased effective dose and secondary malignancy risk.
- Open Access
- 24 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Beam quality and the mystery behind the lower percentage depth dose in grid radiation therapy
Grid therapy recently has been picking momentum due to favorable outcomes in bulky tumors. This is being termed as Spatially Fractionated Radiation Therapy (SFRT) and lattice therapy. SFRT can be performed with specially designed blocks made with brass or cerrobend with repeated holes or using multi-leaf collimators where dosimetry is uncertain. The dosimetric challenge in grid therapy is the mystery behind the lower percentage depth dose (PDD) in grid fields. The knowledge about the beam quality, indexed by TPR20/10 (Tissue Phantom Ratio), is also necessary for absolute dosimetry of grid fields. Since the grid may change the quality of the primary photons, a new $${\mathbf{k}}_{\mathbf{q},{\mathbf{q}}_{0}}$$ should be evaluated for absolute dosimetry of grid fields. A Monte Carlo (MC) approach is provided to resolving the dosimetric issues. Using 6 MV beam from a linear accelerator, MC simulation was performed using MCNPX code. Additionally, a commercial grid therapy device was used to simulate the grid fields. Beam parameters were validated with MC model for output factor, depth of maximum dose, PDDs, dose profiles, and TPR20/10. The electron and photon spectra were also compared between open and grid fields. The dmax is the same for open and grid fields. The PDD with grid is lower (~ 10%) than the open field. The difference in TPR20/10 of open and grid fields is observable (~ 5%). Accordingly, TPR20/10 is still a good index for the beam quality in grid fields and consequently choose the correct $${\mathbf{k}}_{\mathbf{q},{\mathbf{q}}_{0}}$$ in measurements. The output factors for grid fields are 0.2 lower compared to open fields. The lower depth dose with grid therapy is due to lower depth fluence with scatter radiation but it does not impact the dosimetry as the calibration parameters are insensitive to the effective beam energies. Thus, standard dosimetry in open beam based on international protocol could be used.- 24 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessBeam quality and the mystery behind the lower percentage depth dose in grid radiation therapy
Grid therapy recently has been picking momentum due to favorable outcomes in bulky tumors. This is being termed as Spatially Fractionated Radiation Therapy (SFRT) and lattice therapy. SFRT can be performed with specially designed blocks made with brass or cerrobend with repeated holes or using multi-leaf collimators where dosimetry is uncertain. The dosimetric challenge in grid therapy is the mystery behind the lower percentage depth dose (PDD) in grid fields. The knowledge about the beam quality, indexed by TPR20/10 (Tissue Phantom Ratio), is also necessary for absolute dosimetry of grid fields. Since the grid may change the quality of the primary photons, a new $${\mathbf{k}}_{\mathbf{q},{\mathbf{q}}_{0}}$$ should be evaluated for absolute dosimetry of grid fields. A Monte Carlo (MC) approach is provided to resolving the dosimetric issues. Using 6 MV beam from a linear accelerator, MC simulation was performed using MCNPX code. Additionally, a commercial grid therapy device was used to simulate the grid fields. Beam parameters were validated with MC model for output factor, depth of maximum dose, PDDs, dose profiles, and TPR20/10. The electron and photon spectra were also compared between open and grid fields. The dmax is the same for open and grid fields. The PDD with grid is lower (~ 10%) than the open field. The difference in TPR20/10 of open and grid fields is observable (~ 5%). Accordingly, TPR20/10 is still a good index for the beam quality in grid fields and consequently choose the correct $${\mathbf{k}}_{\mathbf{q},{\mathbf{q}}_{0}}$$ in measurements. The output factors for grid fields are 0.2 lower compared to open fields. The lower depth dose with grid therapy is due to lower depth fluence with scatter radiation but it does not impact the dosimetry as the calibration parameters are insensitive to the effective beam energies. Thus, standard dosimetry in open beam based on international protocol could be used. - 18 April 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 197, 110827
Dual application of Polyvinyl Alcohol Glutaraldehyde Methylthymol Blue Fricke hydrogel in clinical practice: Surface dosimeter and bolus
- 18 April 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 197, 110827
Dual application of Polyvinyl Alcohol Glutaraldehyde Methylthymol Blue Fricke hydrogel in clinical practice: Surface dosimeter and bolus
- Open Access
- 13 January 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (1) , e0280433
How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?
Neutron contamination in radiation therapy is of concern in treatment with high-energy photons (> 10 MV). With the development of new radiotherapy modalities such as spatially fractionated grid radiation therapy (SFGRT) or briefly grid radiotherapy, more studies are required to evaluate the risks associated with neutron contamination. In 15 MV SFGRT, high-Z materials such as lead and cerrobend are used as the block on the tray of linear accelerator (linac) which can probably increase the photoneutron production. On the other hand, the high-dose fractions (10–20 Gy) used in SFGRT can induce high neutron contamination. The current study was devoted to addressing these concerns via compression of neutron fluence (Φn) and ambient dose equivalent ( ) at the patient table and inside the maze between SFGRT and conventional fractionated radiation therapy (CFRT). The main components of the 15 MV Siemens Primus equipped with different grids and located inside a typical radiotherapy bunker were simulated by the MCNPX® Monte Carlo code. Evidence showed that the material used for grid construction does not significantly increase neutron contamination inside the maze. However, at the end of the maze, neutron contamination in SFGRT is significantly higher than in CFRT. In this regard, a delay time of 15 minutes after SFGRT is recommended for all radiotherapy staff before entering the maze. It can be also concluded that at the patient table is at least 10 times more pronounced than inside the maze. Therefore, the patient is more at risk of neutrons compared to the staff. The at the isocenter in SFGRT with grids made of lead and cerrobend was nearly equal to CFRT. Nevertheless, it was dramatically lower than in CFRT by 30% if the brass grid is used. Accordingly, SFGRT with the brass grid is recommended, from radiation protection aspects.- 13 January 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (1) , e0280433
Open AccessHow much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?
Neutron contamination in radiation therapy is of concern in treatment with high-energy photons (> 10 MV). With the development of new radiotherapy modalities such as spatially fractionated grid radiation therapy (SFGRT) or briefly grid radiotherapy, more studies are required to evaluate the risks associated with neutron contamination. In 15 MV SFGRT, high-Z materials such as lead and cerrobend are used as the block on the tray of linear accelerator (linac) which can probably increase the photoneutron production. On the other hand, the high-dose fractions (10–20 Gy) used in SFGRT can induce high neutron contamination. The current study was devoted to addressing these concerns via compression of neutron fluence (Φn) and ambient dose equivalent ( ) at the patient table and inside the maze between SFGRT and conventional fractionated radiation therapy (CFRT). The main components of the 15 MV Siemens Primus equipped with different grids and located inside a typical radiotherapy bunker were simulated by the MCNPX® Monte Carlo code. Evidence showed that the material used for grid construction does not significantly increase neutron contamination inside the maze. However, at the end of the maze, neutron contamination in SFGRT is significantly higher than in CFRT. In this regard, a delay time of 15 minutes after SFGRT is recommended for all radiotherapy staff before entering the maze. It can be also concluded that at the patient table is at least 10 times more pronounced than inside the maze. Therefore, the patient is more at risk of neutrons compared to the staff. The at the isocenter in SFGRT with grids made of lead and cerrobend was nearly equal to CFRT. Nevertheless, it was dramatically lower than in CFRT by 30% if the brass grid is used. Accordingly, SFGRT with the brass grid is recommended, from radiation protection aspects. - Open Access
- 29 July 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (7) , e0271028
Semi-experimental assessment of neutron equivalent dose and secondary cancer risk for off-field organs in glioma patients undergoing 18-MV radiotherapy
Neutron contamination as a source of out-of-field dose in radiotherapy is still of concern. High-energy treatment photons have the potential to overcome the binding energy of neutrons inside the nuclei. Fast neutrons emitting from the accelerator head can directly reach the patient’s bed. Considering that modern radiotherapy techniques can increase patient survival, concerns about unwanted doses and the lifetime risk of fatal cancer remain strong or even more prominent, especially in young adult patients. The current study addressed these concerns by quantifying the dose and risk of fatal cancer due to photo-neutrons for glioma patients undergoing 18-MV radiotherapy. In this study, an NRD model rem-meter detector was used to measure neutron ambient dose equivalent, H*(10), at the patient table. Then, the neutron equivalent dose received by each organ was estimated concerning the depth of each organ and by applying depth dose corrections to the measured H*(10). Finally, the effective dose and risk of secondary cancer were determined using NCRP 116 coefficients. Evidence revealed that among all organs, the breast (0.62 mSv/Gy) and gonads (0.58 mSv/Gy) are at risk of photoneutrons more than the other organs in such treatments. The neutron effective dose in the 18-MV conventional radiotherapy of the brain was 13.36 mSv. Among all organs, gonads (6.96 mSv), thyroid (1.86 mSv), and breasts (1.86 mSv) had more contribution to the effective dose, respectively. The total secondary cancer risk was estimated as 281.4 cases (per 1 million persons). The highest risk was related to the breast and gonads with 74.4 and, 34.8 cases per 1 million persons, respectively. Therefore, it is recommended that to prevent late complications (secondary cancer and genetic effects), these organs should be shielded from photoneutrons. This procedure not only improves the quality of the patient’s personal life but also the healthy childbearing in the community.
- 29 July 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (7) , e0271028
Open AccessSemi-experimental assessment of neutron equivalent dose and secondary cancer risk for off-field organs in glioma patients undergoing 18-MV radiotherapy
Neutron contamination as a source of out-of-field dose in radiotherapy is still of concern. High-energy treatment photons have the potential to overcome the binding energy of neutrons inside the nuclei. Fast neutrons emitting from the accelerator head can directly reach the patient’s bed. Considering that modern radiotherapy techniques can increase patient survival, concerns about unwanted doses and the lifetime risk of fatal cancer remain strong or even more prominent, especially in young adult patients. The current study addressed these concerns by quantifying the dose and risk of fatal cancer due to photo-neutrons for glioma patients undergoing 18-MV radiotherapy. In this study, an NRD model rem-meter detector was used to measure neutron ambient dose equivalent, H*(10), at the patient table. Then, the neutron equivalent dose received by each organ was estimated concerning the depth of each organ and by applying depth dose corrections to the measured H*(10). Finally, the effective dose and risk of secondary cancer were determined using NCRP 116 coefficients. Evidence revealed that among all organs, the breast (0.62 mSv/Gy) and gonads (0.58 mSv/Gy) are at risk of photoneutrons more than the other organs in such treatments. The neutron effective dose in the 18-MV conventional radiotherapy of the brain was 13.36 mSv. Among all organs, gonads (6.96 mSv), thyroid (1.86 mSv), and breasts (1.86 mSv) had more contribution to the effective dose, respectively. The total secondary cancer risk was estimated as 281.4 cases (per 1 million persons). The highest risk was related to the breast and gonads with 74.4 and, 34.8 cases per 1 million persons, respectively. Therefore, it is recommended that to prevent late complications (secondary cancer and genetic effects), these organs should be shielded from photoneutrons. This procedure not only improves the quality of the patient’s personal life but also the healthy childbearing in the community.
- 16 March 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 184, 110188
Measurement of neutron equivalent dose in the thyroid, chiasma, and lens for patients undergoing pelvic radiotherapy: A phantom study
- 16 March 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 184, 110188
Measurement of neutron equivalent dose in the thyroid, chiasma, and lens for patients undergoing pelvic radiotherapy: A phantom study