Dimitri Boiroux
Research Subjects
Dimitri Boiroux has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- John Bagterp Jørgensen
Department of Applied Mathematics and Computer Science Matematiktorvet Technical University of Denmark Building 303B Kgs. Lyngby DK-2800 Denmark
48 shared publications - Niels Kjølstad Poulsen
Technical University of Denmark
30 shared publications - Henrik Madsen
Technical University of Denmark
25 shared publications - Kirsten Nørgaard
Diabetes Technology Research, Steno Diabetes Center Copenhagen, Herlev, Denmark
11 shared publications - Zeinab Mahmoudi
Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark
10 shared publications Morten Hagdrup
8 shared publications
Latest Publications
- 25 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 5 (6) , 2030-2035
A Model-Free Approach to Automatic Dose Guidance in Long Acting Insulin Treatment of Type 2 Diabetes
This letter presents a model-free insulin titration algorithm for patients with type 2 diabetes that automatically finds and maintains the optimal insulin dosage in order to maintain the blood glucose concentration at desired levels. The proposed method is based on recursive least square-based extremum seeking control. Since the proposed method does not require a detailed model, it can be applied on a wide population of patients without the need to identify and adapt models to the patient data. We demonstrate the effectiveness of the proposed method using in silico simulations, which are benchmarked against two standard-of-care approaches. We also show that the proposed method can handle intra-patient metabolic variations and non-adherence to the treatment regimen. Finally, using a population of 50 virtual patients, we show that the proposed method is able to handle inter-patient variations.
- 25 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 5 (6) , 2030-2035
A Model-Free Approach to Automatic Dose Guidance in Long Acting Insulin Treatment of Type 2 Diabetes
This letter presents a model-free insulin titration algorithm for patients with type 2 diabetes that automatically finds and maintains the optimal insulin dosage in order to maintain the blood glucose concentration at desired levels. The proposed method is based on recursive least square-based extremum seeking control. Since the proposed method does not require a detailed model, it can be applied on a wide population of patients without the need to identify and adapt models to the patient data. We demonstrate the effectiveness of the proposed method using in silico simulations, which are benchmarked against two standard-of-care approaches. We also show that the proposed method can handle intra-patient metabolic variations and non-adherence to the treatment regimen. Finally, using a population of 50 virtual patients, we show that the proposed method is able to handle inter-patient variations.
- 1 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 208-213
Economic Nonlinear Model Predictive Control of a U-loop Bioreactor
- 1 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 208-213
Economic Nonlinear Model Predictive Control of a U-loop Bioreactor
- 15 January 2020
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 15 (2) , 339-345
Feasibility of a New Approach to Initiate Insulin in Type 2 Diabetes
Background: Treatment inertia and prescription complexity are among reasons that people with type 2 diabetes (T2D) do not reach glycemic targets. This study investigated feasibility of a new approach to basal insulin initiation, where the dose needed to reach a glycemic target is estimated from two weeks of insulin and continuous glucose monitoring (CGM) data. Methods: This was an exploratory single arm study with a maximum length of 84 days. Eight insulin naïve people with T2D, planning to initiate basal insulin, wore a CGM throughout the study period. A predetermined regime was followed for the first two weeks after which the end dose was estimated. The clinician decided whether to follow this advice and continued the titration until target was reached using a twice weekly stepwise titration algorithm. The primary outcome was the comparison between the estimated and the actual end doses. Results: Median age of participants was 57 years (range: 50-77 years), duration of diabetes was 16 years (range: 5-29 years), and Bodi Mass Index (BMI) was 30.2 kg/m2 (range: 22.0-36.0 kg/m2). The median study end dose was 37 U (range: 20-123 U). The estimated end dose was smaller than or equal to the study end dose in all cases, with median error of 26.7% (range: 0.0%-75.8% underestimation). No self-monitoring of blood glucose values were below 70 mg/dL and no severe hypoglycemia occurred. Conclusion: While accuracy may be improved, it was found safe to predict the study end dose of insulin degludec from two weeks of data.
- 15 January 2020
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 15 (2) , 339-345
Feasibility of a New Approach to Initiate Insulin in Type 2 Diabetes
Background: Treatment inertia and prescription complexity are among reasons that people with type 2 diabetes (T2D) do not reach glycemic targets. This study investigated feasibility of a new approach to basal insulin initiation, where the dose needed to reach a glycemic target is estimated from two weeks of insulin and continuous glucose monitoring (CGM) data. Methods: This was an exploratory single arm study with a maximum length of 84 days. Eight insulin naïve people with T2D, planning to initiate basal insulin, wore a CGM throughout the study period. A predetermined regime was followed for the first two weeks after which the end dose was estimated. The clinician decided whether to follow this advice and continued the titration until target was reached using a twice weekly stepwise titration algorithm. The primary outcome was the comparison between the estimated and the actual end doses. Results: Median age of participants was 57 years (range: 50-77 years), duration of diabetes was 16 years (range: 5-29 years), and Bodi Mass Index (BMI) was 30.2 kg/m2 (range: 22.0-36.0 kg/m2). The median study end dose was 37 U (range: 20-123 U). The estimated end dose was smaller than or equal to the study end dose in all cases, with median error of 26.7% (range: 0.0%-75.8% underestimation). No self-monitoring of blood glucose values were below 70 mg/dL and no severe hypoglycemia occurred. Conclusion: While accuracy may be improved, it was found safe to predict the study end dose of insulin degludec from two weeks of data.
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (1) , 500-505
Nonlinear Model Predictive Control for an Exothermic Reaction in an Adiabatic CSTR
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (1) , 500-505
Nonlinear Model Predictive Control for an Exothermic Reaction in an Adiabatic CSTR
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 6983-6988
Efficient Computation of the Continuous-Discrete Extended Kalman Filter Sensitivities Applied to Maximum Likelihood Estimation
In this paper, we present and compare different methods for computing the likelihood function and its gradient. We consider nonlinear continuous-discrete models described by a system of stochastic differential equations (SDEs) with discrete-time measurements. The problem of maximum likelihood estimation (MLE) is formulated as a nonlinear program (NLP) and it is solved numerically using a gradient-based single shooting algorithm. The estimates of the mean and its covariance are computed using a continuous-discrete extended Kalman filter (CDEKF). We derive analytical expressions for the gradient of the likelihood function. We discuss some aspects of the implementation of MLE for non-stiff systems. In particular, we present an efficient way of computing the state covariance matrix and its gradient using explicit Runge-Kutta schemes. We verify our implementation using a numerical example related to type 1 diabetes and demonstrate how to apply it for nonlinear parameter estimation.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 6983-6988
Efficient Computation of the Continuous-Discrete Extended Kalman Filter Sensitivities Applied to Maximum Likelihood Estimation
In this paper, we present and compare different methods for computing the likelihood function and its gradient. We consider nonlinear continuous-discrete models described by a system of stochastic differential equations (SDEs) with discrete-time measurements. The problem of maximum likelihood estimation (MLE) is formulated as a nonlinear program (NLP) and it is solved numerically using a gradient-based single shooting algorithm. The estimates of the mean and its covariance are computed using a continuous-discrete extended Kalman filter (CDEKF). We derive analytical expressions for the gradient of the likelihood function. We discuss some aspects of the implementation of MLE for non-stiff systems. In particular, we present an efficient way of computing the state covariance matrix and its gradient using explicit Runge-Kutta schemes. We verify our implementation using a numerical example related to type 1 diabetes and demonstrate how to apply it for nonlinear parameter estimation.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3762-3769
Model Predictive Control of the Blood Glucose Concentration for Critically Ill Patients in Intensive Care Units
In this paper we present a linear model predictive control (MPC) algorithm for control of the blood glucose concentration of critically ill patients in an intensive care unit (ICU). We present a version of the algorithm that is suitable for automatic control. The algorithm can administer insulin and glucose. The insulin and glucose are administered using a parenteral (intravenous) route. We use a hysteresis logic to switch between insulin and glucose administration to prevent simultaneous administration of insulin and glucose. We test our algorithm in silico using three different simulation models to demonstrate the closed-loop performance of the algorithm. The MPC algorithm is based on linear models in the form of parsimonious second-order transfer functions describing the effect of intravenously injected insulin and glucose on the blood glucose concentration and a first-order disturbance transfer function containing an integrator to ensure offset-free control. The numerical results show that even in the ideal case without any measurement delay, tight glycemic control (80-110 mg/dL) cannot be achieved. Moreover, parenteral glucose is a requirement to avoid hypoglycemia and ensure extended tight glycemic control (60-140 mg/dL).
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3762-3769
Model Predictive Control of the Blood Glucose Concentration for Critically Ill Patients in Intensive Care Units
In this paper we present a linear model predictive control (MPC) algorithm for control of the blood glucose concentration of critically ill patients in an intensive care unit (ICU). We present a version of the algorithm that is suitable for automatic control. The algorithm can administer insulin and glucose. The insulin and glucose are administered using a parenteral (intravenous) route. We use a hysteresis logic to switch between insulin and glucose administration to prevent simultaneous administration of insulin and glucose. We test our algorithm in silico using three different simulation models to demonstrate the closed-loop performance of the algorithm. The MPC algorithm is based on linear models in the form of parsimonious second-order transfer functions describing the effect of intravenously injected insulin and glucose on the blood glucose concentration and a first-order disturbance transfer function containing an integrator to ensure offset-free control. The numerical results show that even in the ideal case without any measurement delay, tight glycemic control (80-110 mg/dL) cannot be achieved. Moreover, parenteral glucose is a requirement to avoid hypoglycemia and ensure extended tight glycemic control (60-140 mg/dL).
- 1 September 2019
- Published by Elsevier in IFAC Journal of Systems and Control
- Vol. 9
Model predictive control for dose guidance in long acting insulin treatment of type 2 diabetes
- 1 September 2019
- Published by Elsevier in IFAC Journal of Systems and Control
- Vol. 9
Model predictive control for dose guidance in long acting insulin treatment of type 2 diabetes
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 920-925
The Extended Kalman Filter for Nonlinear State Estimation in a U-loop Bioreactor
In this paper, we consider nonlinear state estimation in the U-loop reactor for single-cell protein (SCP) production. The model of the U-loop reactor is a mixture of stochastic partial differential equations and stochastic differential equations which are stiff. By a typical finite-volume spatial discretization, the resulting system of stochastic differential equations for numerical simulation and state estimation has 83 states. We investigate and discuss the continuous-discrete EKF for state estimation in this high-dimensional and stiff continuous-discrete-time system.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 920-925
The Extended Kalman Filter for Nonlinear State Estimation in a U-loop Bioreactor
In this paper, we consider nonlinear state estimation in the U-loop reactor for single-cell protein (SCP) production. The model of the U-loop reactor is a mixture of stochastic partial differential equations and stochastic differential equations which are stiff. By a typical finite-volume spatial discretization, the resulting system of stochastic differential equations for numerical simulation and state estimation has 83 states. We investigate and discuss the continuous-discrete EKF for state estimation in this high-dimensional and stiff continuous-discrete-time system.