Pavel B. Rosnitskiy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pavel B. Rosnitskiy has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Vera Aleksandrovna Khokhlova
Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, WA, USA
13 shared publications - Tatiana D. Khokhlova
Department of Medicine, Division of Gastroenterology, University of Washington, Seattle, WA, USA
8 shared publications Oleg A. Sapozhnikov
M. V. Lomonosov Moscow State University
6 shared publications- Oleg A. Sapozhnikov
Applied Physics Laboratory, University of Washington, Seattle, WA, USA
5 shared publications V. A. Khokhlova
Physics Faculty, Moscow State University, 119991, Moscow, Russia
5 shared publications- Petr V. Yuldashev
Faculty of Physics, Moscow State University, Moscow, Russia
4 shared publications
Latest Publications
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (10) , 1336-1351
A Fully Populated Transrectal Array for Boiling Histotripsy Ablation of the Prostate
The endorectal ultrasound (US)-guided thermal ablation of prostate cancer (PCa) using high-intensity focused ultrasound (HIFU) is a widely used focal intervention. While generally safe and effective, it is not without challenges associated with heat diffusion and prefocal heating, which has spurred interest toward nonthermal and mechanical HIFU ablation regimes. Another challenge is the necessity to mechanically translate the HIFU transducer—commonly single-element or annular array—for volumetric treatments, which results in target shifts and transducer position readjustment. The 2-D arrays would address this problem, but their design is challenging in a small form factor. The element pattern must be tightly packed and aperiodic to maximize the active surface area and to suppress grating lobes, respectively. Here, we report on the design, fabrication, and performance evaluation of a 1.5-MHz 128-element transrectal HIFU array driven by Verasonics system capable of mechanical tissue ablation via boiling histotripsy (BH) under real-time coaxial US imaging guidance. A recently developed method for designing randomized, fully populated mosaic arrays was used to create the element pattern. The measured focus steering ranges of the fabricated array were 26 mm axially and 12 mm laterally in the BH regime, with driving voltage compensation by less than 43% and no grating lobe formation. Stress tests with a five-element prototype confirmed safe operating voltage of 850-V peak-to-peak, corresponding to the acoustic intensity of 542 W/cm2 at the array surface. The array integrated with a 128-element US imaging probe driven by the same Verasonics system was successfully used to produce volumetric BH lesions in polyacrylamide (PAA) tissue-mimicking phantoms.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (10) , 1336-1351
A Fully Populated Transrectal Array for Boiling Histotripsy Ablation of the Prostate
The endorectal ultrasound (US)-guided thermal ablation of prostate cancer (PCa) using high-intensity focused ultrasound (HIFU) is a widely used focal intervention. While generally safe and effective, it is not without challenges associated with heat diffusion and prefocal heating, which has spurred interest toward nonthermal and mechanical HIFU ablation regimes. Another challenge is the necessity to mechanically translate the HIFU transducer—commonly single-element or annular array—for volumetric treatments, which results in target shifts and transducer position readjustment. The 2-D arrays would address this problem, but their design is challenging in a small form factor. The element pattern must be tightly packed and aperiodic to maximize the active surface area and to suppress grating lobes, respectively. Here, we report on the design, fabrication, and performance evaluation of a 1.5-MHz 128-element transrectal HIFU array driven by Verasonics system capable of mechanical tissue ablation via boiling histotripsy (BH) under real-time coaxial US imaging guidance. A recently developed method for designing randomized, fully populated mosaic arrays was used to create the element pattern. The measured focus steering ranges of the fabricated array were 26 mm axially and 12 mm laterally in the BH regime, with driving voltage compensation by less than 43% and no grating lobe formation. Stress tests with a five-element prototype confirmed safe operating voltage of 850-V peak-to-peak, corresponding to the acoustic intensity of 542 W/cm2 at the array surface. The array integrated with a 128-element US imaging probe driven by the same Verasonics system was successfully used to produce volumetric BH lesions in polyacrylamide (PAA) tissue-mimicking phantoms.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (5) , 564-580
xDDx: A Numerical Toolbox for Ultrasound Transducer Characterization and Design With Acoustic Holography
Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer—a hologram—and subsequent numerical forward projection (FP) or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface. This allows identification of transducer defects as well as structural details of the radiated acoustic field such as sidelobes and hot spots. However, numerical projections may be time-consuming ( $10^{{10}}$ – $10^{{11}}$ operations with complex exponents). Moreover, backprojection from the measurement plane to the transducer surface is sensitive to misalignment between the axes of the positioning system and the axes associated with the transducer. This article presents an open-access transducer characterization toolbox for use in MATLAB or Octave on Windows computers (https://github.com/pavrosni/xDDx/releases). The core algorithm is based on the Rayleigh integral implemented in C++ executables for graphics and central processing units (GPUs and CPUs). The toolbox includes an automated procedure for correcting axes misalignments to optimize the visualization of transducer surface vibrations. Beyond using measured holograms, the toolbox can also simulate the fields radiated by user-defined transducers. Measurements from two focused 1.25-MHz 12-element sector transducers (apertures of 87 mm and focal distances of 65 and 87 mm) were used with the toolbox for demonstration purposes. Simulation speed tests for different computational devices showed a range of 0.2 s–3 min for GPUs and 1.6 s–57 min for CPUs.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (5) , 564-580
xDDx: A Numerical Toolbox for Ultrasound Transducer Characterization and Design With Acoustic Holography
Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer—a hologram—and subsequent numerical forward projection (FP) or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface. This allows identification of transducer defects as well as structural details of the radiated acoustic field such as sidelobes and hot spots. However, numerical projections may be time-consuming ( $10^{{10}}$ – $10^{{11}}$ operations with complex exponents). Moreover, backprojection from the measurement plane to the transducer surface is sensitive to misalignment between the axes of the positioning system and the axes associated with the transducer. This article presents an open-access transducer characterization toolbox for use in MATLAB or Octave on Windows computers (https://github.com/pavrosni/xDDx/releases). The core algorithm is based on the Rayleigh integral implemented in C++ executables for graphics and central processing units (GPUs and CPUs). The toolbox includes an automated procedure for correcting axes misalignments to optimize the visualization of transducer surface vibrations. Beyond using measured holograms, the toolbox can also simulate the fields radiated by user-defined transducers. Measurements from two focused 1.25-MHz 12-element sector transducers (apertures of 87 mm and focal distances of 65 and 87 mm) were used with the toolbox for demonstration purposes. Simulation speed tests for different computational devices showed a range of 0.2 s–3 min for GPUs and 1.6 s–57 min for CPUs.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1868-1878
Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R 2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1868-1878
Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R 2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 341-353
Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of renal tumors often encounter challenges due to significant beam aberration and refraction caused by oblique beam incidence, inhomogeneous tissue layers, and presence of gas and bones within the beam. These losses can be significantly mitigated through sonication geometry planning, patient positioning, and aberration correction using multielement phased arrays. Here, a sonication planning algorithm is introduced, which uses the simulations to select the optimal transducer position and evaluate the effect of aberrations and acoustic field quality at the target region after aberration correction. Optimization of transducer positioning is implemented using a graphical user interface (GUI) to visualize a segmented 3-D computed tomography (CT)-based acoustic model of the body and to select sonication geometry through a combination of manual and automated approaches. An HIFU array (1.5 MHz, 256 elements) and three renal cell carcinoma (RCC) cases with different tumor locations and patient body habitus were considered. After array positioning, the correction of aberrations was performed using a combination of backpropagation from the focus with an ordinary least squares (OLS) optimization of phases at the array elements. The forward propagation was simulated using a combination of the Rayleigh integral and k-space pseudospectral method (k-Wave toolbox). After correction, simulated HIFU fields showed tight focusing and up to threefold higher maximum pressure within the target region. The addition of OLS optimization to the aberration correction method yielded up to 30% higher maximum pressure compared to the conventional backpropagation and up to 250% higher maximum pressure compared to the ray-tracing method, particularly in strongly distorted cases.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 341-353
Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of renal tumors often encounter challenges due to significant beam aberration and refraction caused by oblique beam incidence, inhomogeneous tissue layers, and presence of gas and bones within the beam. These losses can be significantly mitigated through sonication geometry planning, patient positioning, and aberration correction using multielement phased arrays. Here, a sonication planning algorithm is introduced, which uses the simulations to select the optimal transducer position and evaluate the effect of aberrations and acoustic field quality at the target region after aberration correction. Optimization of transducer positioning is implemented using a graphical user interface (GUI) to visualize a segmented 3-D computed tomography (CT)-based acoustic model of the body and to select sonication geometry through a combination of manual and automated approaches. An HIFU array (1.5 MHz, 256 elements) and three renal cell carcinoma (RCC) cases with different tumor locations and patient body habitus were considered. After array positioning, the correction of aberrations was performed using a combination of backpropagation from the focus with an ordinary least squares (OLS) optimization of phases at the array elements. The forward propagation was simulated using a combination of the Rayleigh integral and k-space pseudospectral method (k-Wave toolbox). After correction, simulated HIFU fields showed tight focusing and up to threefold higher maximum pressure within the target region. The addition of OLS optimization to the aberration correction method yielded up to 30% higher maximum pressure compared to the conventional backpropagation and up to 250% higher maximum pressure compared to the ray-tracing method, particularly in strongly distorted cases.
- 7 May 2023
- Published by Elsevier in Ultrasonics
- Vol. 133, 107029
Pilot ex vivo study on non-thermal ablation of human prostate adenocarcinoma tissue using boiling histotripsy
- 7 May 2023
- Published by Elsevier in Ultrasonics
- Vol. 133, 107029
Pilot ex vivo study on non-thermal ablation of human prostate adenocarcinoma tissue using boiling histotripsy
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A86
Aberration-inducing body wall phantom for high-intensity focused ultrasound applications
Aberrations induced by soft tissue inhomogeneities distort acoustic fields and often complicate HIFU therapies. An aberration-generating phantom was designed and fabricated to mimic the acoustic effects of a porcine body wall. A rippled surface pattern replicating inhomogeneities of size scales relevant to the porcine body wall was transferred to a large phantom made of fat-like and muscle-like gel materials. The acoustic distortions produced by the phantom and an ex vivo porcine body wall were characterized by hydrophone measurements with a 256-element 1.5 MHz focused ultrasound array (diameter = 144 mm, F# = 0.83). Insertion of the phantom generated large distortions for both linear and nonlinear beam focusing including displacement of the focus (up to 0.3 mm transversely), enlargement of the focal region, and reduction in focal pressures due to aberration (up to 2.5-fold peak positive pressure reduction). The phantom and porcine body wall produced similar levels of aberration and attenuation effects. An aberration correction approach was leveraged to isolate the quantitative effect of aberration and to restore shocks in nonlinear waveforms in the focus. Boiling histotripsy treatments through the phantom or body wall were subsequently demonstrated in a hematoma sample. [This work was supported by NIH R01EB7643 and R01EB25187, and RSF 20-12-00145.]
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A86
Aberration-inducing body wall phantom for high-intensity focused ultrasound applications
Aberrations induced by soft tissue inhomogeneities distort acoustic fields and often complicate HIFU therapies. An aberration-generating phantom was designed and fabricated to mimic the acoustic effects of a porcine body wall. A rippled surface pattern replicating inhomogeneities of size scales relevant to the porcine body wall was transferred to a large phantom made of fat-like and muscle-like gel materials. The acoustic distortions produced by the phantom and an ex vivo porcine body wall were characterized by hydrophone measurements with a 256-element 1.5 MHz focused ultrasound array (diameter = 144 mm, F# = 0.83). Insertion of the phantom generated large distortions for both linear and nonlinear beam focusing including displacement of the focus (up to 0.3 mm transversely), enlargement of the focal region, and reduction in focal pressures due to aberration (up to 2.5-fold peak positive pressure reduction). The phantom and porcine body wall produced similar levels of aberration and attenuation effects. An aberration correction approach was leveraged to isolate the quantitative effect of aberration and to restore shocks in nonlinear waveforms in the focus. Boiling histotripsy treatments through the phantom or body wall were subsequently demonstrated in a hematoma sample. [This work was supported by NIH R01EB7643 and R01EB25187, and RSF 20-12-00145.]
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A84
Large-aperture 256-element fully populated random array for therapeutic ultrasound applications: Experimental study of its functionality and characterization of the radiated field
Recently, a new method has been proposed for designing random high-intensity focused ultrasound (HIFU) arrays with the maximum possible filling factor and polygonal elements of equal area, based on capacity constrained tessellation [Rosnitskiy et al., IEEE Trans. UFFC (2018)]. Following this approach, a 256-element piezocomposite array with a radius of curvature of 150 mm, a diameter of 200 mm, and an operating frequency of 1.2 MHz was designed at the Laboratory for Industrial and Medical Ultrasound (LIMU) of Moscow State University. The array was subsequently manufactured by Imasonic (France). It can be driven using a Verasonics ultrasound engine. Electrical matching was performed for each element using matching network created by Image Guided Therapy (France). This report presents the system design procedure and experimental results for array characterization using acoustic holography and acoustic power measurements using the radiation force balance. In addition, a theoretical study was carried out using the “HIFU beam” simulator developed at LIMU (freely available at www.limu.msu.ru) to assess the array's ability to achieve highly nonlinear regimes with shocked pressure waveforms. The possibility of using the array for HIFU applications such as acoustic levitation and manipulation, histotripsy and transcostal HIFU therapy is discussed. [Work supported by RSF 19-12-00148.]
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A84
Large-aperture 256-element fully populated random array for therapeutic ultrasound applications: Experimental study of its functionality and characterization of the radiated field
Recently, a new method has been proposed for designing random high-intensity focused ultrasound (HIFU) arrays with the maximum possible filling factor and polygonal elements of equal area, based on capacity constrained tessellation [Rosnitskiy et al., IEEE Trans. UFFC (2018)]. Following this approach, a 256-element piezocomposite array with a radius of curvature of 150 mm, a diameter of 200 mm, and an operating frequency of 1.2 MHz was designed at the Laboratory for Industrial and Medical Ultrasound (LIMU) of Moscow State University. The array was subsequently manufactured by Imasonic (France). It can be driven using a Verasonics ultrasound engine. Electrical matching was performed for each element using matching network created by Image Guided Therapy (France). This report presents the system design procedure and experimental results for array characterization using acoustic holography and acoustic power measurements using the radiation force balance. In addition, a theoretical study was carried out using the “HIFU beam” simulator developed at LIMU (freely available at www.limu.msu.ru) to assess the array's ability to achieve highly nonlinear regimes with shocked pressure waveforms. The possibility of using the array for HIFU applications such as acoustic levitation and manipulation, histotripsy and transcostal HIFU therapy is discussed. [Work supported by RSF 19-12-00148.]
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (9) , 2884-2895
Inertial Cavitation Behaviors Induced by Nonlinear Focused Ultrasound Pulses
Inertial cavitation induced by pulsed high-intensity focused ultrasound (pHIFU) has previously been shown to successfully permeabilize tumor tissue and enhance chemotherapeutic drug uptake. In addition to HIFU frequency, peak rarefactional pressure ( p - ), and pulse duration, the threshold for cavitation-induced bioeffects has recently been correlated with asymmetric distortion caused by nonlinear propagation, diffraction and formation of shocks in the focal waveform, and therefore with the transducer F-number. To connect previously observed bioeffects with bubble dynamics and their attendant physical mechanisms, the dependence of inertial cavitation behavior on shock formation was investigated in transparent agarose gel phantoms using high-speed photography and passive cavitation detection (PCD). Agarose phantoms with concentrations ranging from 1.5% to 5% were exposed to 1-ms pulses using three transducers of the same aperture but different focal distances ( F-numbers of 0.77, 1.02, and 1.52). Pulses had central frequencies of 1, 1.5, or 1.9 MHz and a range of p - at the focus varying within 1-18 MPa. Three distinct categories of bubble behavior were observed as the acoustic power increased: stationary near-spherical oscillation of individual bubbles, proliferation of multiple bubbles along the pHIFU beam axis, and fanned-out proliferation toward the transducer. Proliferating bubbles were only observed under strongly nonlinear or shock-forming conditions regardless of frequency, and only where the bubbles reached a certain threshold size range. In stiffer gels with higher agarose concentrations, the same pattern of cavitation behavior was observed, but the dimensions of proliferating clouds were smaller. These observations suggest mechanisms that may be involved in bubble proliferation: enhanced growth of bubbles under shock-forming conditions, subsequent shock scattering from the gel-bubble interface, causing an increase in the repetitive tension created by the acoustic wave, and the appearance of a new growing bubble in the proximal direction. Different behaviors corresponded to specific spectral characteristics in the PCD signals: broadband noise in all cases, narrow peaks of backscattered harmonics in the case of stationary bubbles, and broadened, shifted harmonic peaks in the case of proliferating bubbles. The shift in harmonic peaks can be interpreted as a Doppler shift from targets moving at speeds of up to 2 m/s, which correspond to the observed bubble proliferation speeds.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (9) , 2884-2895
Inertial Cavitation Behaviors Induced by Nonlinear Focused Ultrasound Pulses
Inertial cavitation induced by pulsed high-intensity focused ultrasound (pHIFU) has previously been shown to successfully permeabilize tumor tissue and enhance chemotherapeutic drug uptake. In addition to HIFU frequency, peak rarefactional pressure ( p - ), and pulse duration, the threshold for cavitation-induced bioeffects has recently been correlated with asymmetric distortion caused by nonlinear propagation, diffraction and formation of shocks in the focal waveform, and therefore with the transducer F-number. To connect previously observed bioeffects with bubble dynamics and their attendant physical mechanisms, the dependence of inertial cavitation behavior on shock formation was investigated in transparent agarose gel phantoms using high-speed photography and passive cavitation detection (PCD). Agarose phantoms with concentrations ranging from 1.5% to 5% were exposed to 1-ms pulses using three transducers of the same aperture but different focal distances ( F-numbers of 0.77, 1.02, and 1.52). Pulses had central frequencies of 1, 1.5, or 1.9 MHz and a range of p - at the focus varying within 1-18 MPa. Three distinct categories of bubble behavior were observed as the acoustic power increased: stationary near-spherical oscillation of individual bubbles, proliferation of multiple bubbles along the pHIFU beam axis, and fanned-out proliferation toward the transducer. Proliferating bubbles were only observed under strongly nonlinear or shock-forming conditions regardless of frequency, and only where the bubbles reached a certain threshold size range. In stiffer gels with higher agarose concentrations, the same pattern of cavitation behavior was observed, but the dimensions of proliferating clouds were smaller. These observations suggest mechanisms that may be involved in bubble proliferation: enhanced growth of bubbles under shock-forming conditions, subsequent shock scattering from the gel-bubble interface, causing an increase in the repetitive tension created by the acoustic wave, and the appearance of a new growing bubble in the proximal direction. Different behaviors corresponded to specific spectral characteristics in the PCD signals: broadband noise in all cases, narrow peaks of backscattered harmonics in the case of stationary bubbles, and broadened, shifted harmonic peaks in the case of proliferating bubbles. The shift in harmonic peaks can be interpreted as a Doppler shift from targets moving at speeds of up to 2 m/s, which correspond to the observed bubble proliferation speeds.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (9) , 2837-2852
“HIFU Beam:” A Simulator for Predicting Axially Symmetric Nonlinear Acoustic Fields Generated by Focused Transducers in a Layered Medium
"HIFU beam" is a freely available software tool that comprises a MATLAB toolbox combined with a user-friendly interface and binary executable compiled from FORTRAN source code (HIFU beam. (2021). Available: http://limu.msu.ru/node/3555?language=en). It is designed for simulating high-intensity focused ultrasound (HIFU) fields generated by single-element transducers and annular arrays with propagation in flat-layered media that mimic biological tissues. Numerical models incorporated in the simulator include evolution-type equations, either the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation or one-way Westervelt equation, for radially symmetric ultrasound beams in homogeneous and layered media with thermoviscous or power-law acoustic absorption. The software uses shock-capturing methods that allow for simulating strongly nonlinear acoustic fields with high-amplitude shocks. In this article, a general description of the software is given along with three representative simulation cases of ultrasound transducers and focusing conditions typical for therapeutic applications. The examples illustrate major nonlinear wave effects in HIFU fields including shock formation. Two examples simulate propagation in water, involving a single-element source (1-MHz frequency, 100-mm diameter, 90-mm radius of curvature) and a 16-element annular array (3-MHz frequency, 48-mm diameter, and 35-mm radius of curvature). The third example mimics the scenario of a HIFU treatment in a “water-muscle-kidney” layered medium using a source typical for abdominal HIFU applications (1.2-MHz frequency, 120-mm diameter, and radius of curvature). Linear, quasi-linear, and shock-wave exposure protocols are considered. It is intended that “HIFU beam” can be useful in teaching nonlinear acoustics; designing and characterizing high-power transducers; and developing exposure protocols for a wide range of therapeutic applications such as shock-based HIFU, boiling histotripsy, drug delivery, immunotherapy, and others.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (9) , 2837-2852
“HIFU Beam:” A Simulator for Predicting Axially Symmetric Nonlinear Acoustic Fields Generated by Focused Transducers in a Layered Medium
"HIFU beam" is a freely available software tool that comprises a MATLAB toolbox combined with a user-friendly interface and binary executable compiled from FORTRAN source code (HIFU beam. (2021). Available: http://limu.msu.ru/node/3555?language=en). It is designed for simulating high-intensity focused ultrasound (HIFU) fields generated by single-element transducers and annular arrays with propagation in flat-layered media that mimic biological tissues. Numerical models incorporated in the simulator include evolution-type equations, either the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation or one-way Westervelt equation, for radially symmetric ultrasound beams in homogeneous and layered media with thermoviscous or power-law acoustic absorption. The software uses shock-capturing methods that allow for simulating strongly nonlinear acoustic fields with high-amplitude shocks. In this article, a general description of the software is given along with three representative simulation cases of ultrasound transducers and focusing conditions typical for therapeutic applications. The examples illustrate major nonlinear wave effects in HIFU fields including shock formation. Two examples simulate propagation in water, involving a single-element source (1-MHz frequency, 100-mm diameter, 90-mm radius of curvature) and a 16-element annular array (3-MHz frequency, 48-mm diameter, and 35-mm radius of curvature). The third example mimics the scenario of a HIFU treatment in a “water-muscle-kidney” layered medium using a source typical for abdominal HIFU applications (1.2-MHz frequency, 120-mm diameter, and radius of curvature). Linear, quasi-linear, and shock-wave exposure protocols are considered. It is intended that “HIFU beam” can be useful in teaching nonlinear acoustics; designing and characterizing high-power transducers; and developing exposure protocols for a wide range of therapeutic applications such as shock-based HIFU, boiling histotripsy, drug delivery, immunotherapy, and others.