Sungsam Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sungsam Kang has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Wonshik Choi
Department of physics, Korea university, Seoul 02841, Republic of Korea
16 shared publications - Jin Hee Hong
Korea University
7 shared publications - Seokchan Yoon
Quantum Science Technology Center, Pusan National University, Busan, Republic of Korea
6 shared publications Moonseok Kim
Department of Medical Life Sciences, College of Medicine, The Catholic University of Korea, Seoul, Korea
5 shared publicationsSeokchan Yoon
Pusan National University
5 shared publicationsWonjun Choi
5 shared publications
Latest Publications
- 21 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34  (22) , 41425
Model-fitting perspective on the robustness and speed of CLASS in reflection matrix microscopy
Closed-loop accumulation of single scattering (CLASS) recovers the input and output pupil aberrations from intrinsic tissue reflections, even under strong multiple scattering. Its central principle is to maximize the correlation among the ballistic waves in a measured reflection matrix, so that elements sharing the same momentum transfer add coherently. Here we recast CLASS as the solution of a model-fitting problem. We show that correlation maximization is equivalent to a least-squares fit of the measured matrix to a separable forward model with two specific features. First, variable projection removes the object spectrum from the fitted parameters by folding it into the pupil-aberration update. Second, each group of matrix elements sharing the same momentum transfer is weighted in proportion to its size, so the fit favors higher-fidelity data. We then test this account by comparing CLASS against model fits that lack one or both of these features. For the comparison, we devised an experimental scheme that measures reflection matrices with the aberration and the multiple-scattering background controlled independently on a single target. Under increasing scattering and aberration, a fit that trains the object spectrum matches the reduced fit and CLASS once its object learning rate is scaled to the data; variable projection removes the need to choose this rate. Under reduced angular sampling, the unweighted fits work reliably only up to approximately 24% of the illumination angles removed, whereas CLASS, the multiplicity-weighted fit, keeps working up to 53%. CLASS stays accurate over the widest range and, in our implementation, converges fastest. We release these matrices as benchmark data.
- 21 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34  (22) , 41425
Model-fitting perspective on the robustness and speed of CLASS in reflection matrix microscopy
Closed-loop accumulation of single scattering (CLASS) recovers the input and output pupil aberrations from intrinsic tissue reflections, even under strong multiple scattering. Its central principle is to maximize the correlation among the ballistic waves in a measured reflection matrix, so that elements sharing the same momentum transfer add coherently. Here we recast CLASS as the solution of a model-fitting problem. We show that correlation maximization is equivalent to a least-squares fit of the measured matrix to a separable forward model with two specific features. First, variable projection removes the object spectrum from the fitted parameters by folding it into the pupil-aberration update. Second, each group of matrix elements sharing the same momentum transfer is weighted in proportion to its size, so the fit favors higher-fidelity data. We then test this account by comparing CLASS against model fits that lack one or both of these features. For the comparison, we devised an experimental scheme that measures reflection matrices with the aberration and the multiple-scattering background controlled independently on a single target. Under increasing scattering and aberration, a fit that trains the object spectrum matches the reduced fit and CLASS once its object learning rate is scaled to the data; variable projection removes the need to choose this rate. Under reduced angular sampling, the unweighted fits work reliably only up to approximately 24% of the illumination angles removed, whereas CLASS, the multiplicity-weighted fit, keeps working up to 53%. CLASS stays accurate over the widest range and, in our implementation, converges fastest. We release these matrices as benchmark data.
- 23 September 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17  (10) , 5285-5298
Reflection matrix microscopy at 1.6 µm wavelength for label-free deep-tissue imaging
Multiple light scattering sets the depth limit of optical microscopy in biological tissue. Reflection matrix microscopy with the multiple-scattering tracing algorithm can overcome this scattering, but its application has so far been limited to wavelengths of 1.3 μm and below. Here, we develop, to our knowledge, the first reflection matrix microscope operating at 1.6 μm. By integrating it with a 1.3 μm channel into a single dual-wavelength system that isolates the wavelength as the principal variable, we quantitatively demonstrate that 1.6 μm markedly outperforms 1.3 μm. The reconstructed phase distortion in the mouse skull is weaker at 1.6 μm and the isoplanatic patch about 1.67 times larger. We resolve osteocytes lying beneath the strongly scattering bone marrow of the skull, a target unreachable at 1.3 μm.
- 23 September 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17  (10) , 5285-5298
Reflection matrix microscopy at 1.6 µm wavelength for label-free deep-tissue imaging
Multiple light scattering sets the depth limit of optical microscopy in biological tissue. Reflection matrix microscopy with the multiple-scattering tracing algorithm can overcome this scattering, but its application has so far been limited to wavelengths of 1.3 μm and below. Here, we develop, to our knowledge, the first reflection matrix microscope operating at 1.6 μm. By integrating it with a 1.3 μm channel into a single dual-wavelength system that isolates the wavelength as the principal variable, we quantitatively demonstrate that 1.6 μm markedly outperforms 1.3 μm. The reconstructed phase distortion in the mouse skull is weaker at 1.6 μm and the isoplanatic patch about 1.67 times larger. We resolve osteocytes lying beneath the strongly scattering bone marrow of the skull, a target unreachable at 1.3 μm.
- Open Access
- 4 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17  (1) , 2123
Dual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector with a camera from the conventional laser-scanning multiphoton microscope, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 μm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- 4 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17  (1) , 2123
Open AccessDual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector with a camera from the conventional laser-scanning multiphoton microscope, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 μm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- 16 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17  (1) , 294-304
Long-wavelength oblique back-illumination microscopy for deep in vivo imaging
Oblique back-illumination microscopy (OBM) is a label-free imaging technique that captures differential forward scattering in reflection mode to generate high-contrast pseudo-transmission images of cells and microvessels. While OBM benefits from multiple light scattering to detect forward-scattered signals, its imaging depth is constrained by tissue scattering between the objective lens and the imaging plane. In this study, we introduce a long-wavelength OBM system operating at 1650 nm—significantly longer than previous implementations—to mitigate scattering effects and extend imaging depth. Compared to a similar system using an 800 nm light source, our 1650 nm OBM achieves markedly deeper in vivo imaging of the mouse brain. This advancement in high-contrast, deep-tissue imaging holds promise for more detailed investigations into the pathophysiology of living biological systems.
- 16 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17  (1) , 294-304
Long-wavelength oblique back-illumination microscopy for deep in vivo imaging
Oblique back-illumination microscopy (OBM) is a label-free imaging technique that captures differential forward scattering in reflection mode to generate high-contrast pseudo-transmission images of cells and microvessels. While OBM benefits from multiple light scattering to detect forward-scattered signals, its imaging depth is constrained by tissue scattering between the objective lens and the imaging plane. In this study, we introduce a long-wavelength OBM system operating at 1650 nm—significantly longer than previous implementations—to mitigate scattering effects and extend imaging depth. Compared to a similar system using an 800 nm light source, our 1650 nm OBM achieves markedly deeper in vivo imaging of the mouse brain. This advancement in high-contrast, deep-tissue imaging holds promise for more detailed investigations into the pathophysiology of living biological systems.
- Open Access
- 17 June 2025
- Published by Springer Nature in Research Square
Dual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector in a conventional laser-scanning multiphoton microscope with a camera, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 µm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- 17 June 2025
- Published by Springer Nature in Research Square
Open AccessDual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector in a conventional laser-scanning multiphoton microscope with a camera, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 µm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- Open Access
- 28 February 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7  (2) , 023002
Implementation of reflection matrix microscopy: an algorithm perspective
Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In this study, we introduce significant advancements in reflection matrix processing algorithms, including logical indexing, power iterations, and low-frequency blocking. These enhance the processing speed of aperture synthesis, 3D image reconstruction, and aberration correction by orders of magnitude. Detailed algorithm implementations, along with experimental data, are provided to facilitate the widespread adoption of RMM in various deep-tissue imaging applications.
- 28 February 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7  (2) , 023002
Open AccessImplementation of reflection matrix microscopy: an algorithm perspective
Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In this study, we introduce significant advancements in reflection matrix processing algorithms, including logical indexing, power iterations, and low-frequency blocking. These enhance the processing speed of aperture synthesis, 3D image reconstruction, and aberration correction by orders of magnitude. Detailed algorithm implementations, along with experimental data, are provided to facilitate the widespread adoption of RMM in various deep-tissue imaging applications.
- 19 January 2024
- Published by Optica Publishing Group in Optica
- Vol. 11  (1) , 128-136
Second-harmonic generation microscopy with synthetic aperture and computational adaptive optics
Second-harmonic generation (SHG) microscopy is a powerful label-free imaging tool widely used to visualize collagen and muscle in biological tissues. However, traditional laser-scanning SHG microscopy requiring voxel scanning is time-intensive. Wide-field SHG microscopy was designed to bypass this restriction, but its application to deep tissue imaging is limited due to vulnerability to scattering and sample-induced aberrations. We introduce synthetic aperture SHG (SA-SHG) microscopy to attenuate the effect of multiple scattering noises. Our SA-SHG method coherently integrates amplitude and phase maps of wide-field SHG fields taken for different illumination angles, thereby enhancing the signal-to-noise ratio. We also develop computational adaptive optics SHG (CAO-SHG) microscopy to computationally correct the sample-induced aberrations. Our algorithm optimizes SHG fields’ aperture synthesis to identify aberration maps, enabling the restoration of diffraction-limited imaging. We successfully apply this approach to real biological samples, demonstrating its potential for high-resolution imaging in complex biological environments.
- 19 January 2024
- Published by Optica Publishing Group in Optica
- Vol. 11  (1) , 128-136
Second-harmonic generation microscopy with synthetic aperture and computational adaptive optics
Second-harmonic generation (SHG) microscopy is a powerful label-free imaging tool widely used to visualize collagen and muscle in biological tissues. However, traditional laser-scanning SHG microscopy requiring voxel scanning is time-intensive. Wide-field SHG microscopy was designed to bypass this restriction, but its application to deep tissue imaging is limited due to vulnerability to scattering and sample-induced aberrations. We introduce synthetic aperture SHG (SA-SHG) microscopy to attenuate the effect of multiple scattering noises. Our SA-SHG method coherently integrates amplitude and phase maps of wide-field SHG fields taken for different illumination angles, thereby enhancing the signal-to-noise ratio. We also develop computational adaptive optics SHG (CAO-SHG) microscopy to computationally correct the sample-induced aberrations. Our algorithm optimizes SHG fields’ aperture synthesis to identify aberration maps, enabling the restoration of diffraction-limited imaging. We successfully apply this approach to real biological samples, demonstrating its potential for high-resolution imaging in complex biological environments.
- Open Access
- 28 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14  (1) , 1-12
Tracing multiple scattering trajectories for deep optical imaging in scattering media
Multiple light scattering hampers imaging objects in complex scattering media. Approaches used in real practices mainly aim to filter out multiple scattering obscuring the ballistic waves that travel straight through the scattering medium. Here, we propose a method that makes the deterministic use of multiple scattering for microscopic imaging of an object embedded deep within scattering media. The proposed method finds a stack of multiple complex phase plates that generate similar light trajectories as the original scattering medium. By implementing the inverse scattering using the identified phase plates, our method rectifies multiple scattering and amplifies ballistic waves by almost 600 times. This leads to a significant increase in imaging depth—more than three times the scattering mean free path—as well as the correction of image distortions. Our study marks an important milestone in solving the long-standing high-order inverse scattering problems.
- 28 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14  (1) , 1-12
Open AccessTracing multiple scattering trajectories for deep optical imaging in scattering media
Multiple light scattering hampers imaging objects in complex scattering media. Approaches used in real practices mainly aim to filter out multiple scattering obscuring the ballistic waves that travel straight through the scattering medium. Here, we propose a method that makes the deterministic use of multiple scattering for microscopic imaging of an object embedded deep within scattering media. The proposed method finds a stack of multiple complex phase plates that generate similar light trajectories as the original scattering medium. By implementing the inverse scattering using the identified phase plates, our method rectifies multiple scattering and amplifies ballistic waves by almost 600 times. This leads to a significant increase in imaging depth—more than three times the scattering mean free path—as well as the correction of image distortions. Our study marks an important milestone in solving the long-standing high-order inverse scattering problems.
- Open Access
- 22 August 2023
- Published by Springer Nature in Light: Science & Applications
- Vol. 12  (1) , 1-9
Mapping nanoscale topographic features in thick tissues with speckle diffraction tomography
Resolving three-dimensional morphological features in thick specimens remains a significant challenge for label-free imaging. We report a new speckle diffraction tomography (SDT) approach that can image thick biological specimens with ~500 nm lateral resolution and ~1 μm axial resolution in a reflection geometry. In SDT, multiple-scattering background is rejected through spatiotemporal gating provided by dynamic speckle-field interferometry, while depth-resolved refractive index maps are reconstructed by developing a comprehensive inverse-scattering model that also considers specimen-induced aberrations. Benefiting from the high-resolution and full-field quantitative imaging capabilities of SDT, we successfully imaged red blood cells and quantified their membrane fluctuations behind a turbid medium with a thickness of 2.8 scattering mean-free paths. Most importantly, we performed volumetric imaging of cornea inside an ex vivo rat eye and quantified its optical properties, including the mapping of nanoscale topographic features of Dua’s and Descemet’s membranes that had not been previously visualized.
- 22 August 2023
- Published by Springer Nature in Light: Science & Applications
- Vol. 12  (1) , 1-9
Open AccessMapping nanoscale topographic features in thick tissues with speckle diffraction tomography
Resolving three-dimensional morphological features in thick specimens remains a significant challenge for label-free imaging. We report a new speckle diffraction tomography (SDT) approach that can image thick biological specimens with ~500 nm lateral resolution and ~1 μm axial resolution in a reflection geometry. In SDT, multiple-scattering background is rejected through spatiotemporal gating provided by dynamic speckle-field interferometry, while depth-resolved refractive index maps are reconstructed by developing a comprehensive inverse-scattering model that also considers specimen-induced aberrations. Benefiting from the high-resolution and full-field quantitative imaging capabilities of SDT, we successfully imaged red blood cells and quantified their membrane fluctuations behind a turbid medium with a thickness of 2.8 scattering mean-free paths. Most importantly, we performed volumetric imaging of cornea inside an ex vivo rat eye and quantified its optical properties, including the mapping of nanoscale topographic features of Dua’s and Descemet’s membranes that had not been previously visualized.
- 31 July 2023
- Published by Springer Nature in Nature Physics
- Vol. 19  (11) , 1709-1718
Measuring the scattering tensor of a disordered nonlinear medium
- 31 July 2023
- Published by Springer Nature in Nature Physics
- Vol. 19  (11) , 1709-1718
Measuring the scattering tensor of a disordered nonlinear medium