Wonshik Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wonshik Choi has a total of 191 co-authors. Here are the top co-authors by number of shared publications:
Moonseok Kim
Department of Medical Life Sciences, College of Medicine, The Catholic University of Korea, Seoul, Korea
22 shared publicationsWonjun Choi
20 shared publicationsJin Hee Hong
Department of Physics Korea University 02841 Seoul Korea
19 shared publications- Sungsam Kang
Institute for Basic Science
16 shared publications Youngwoon Choi
School of Biomedical Engineering, Korea University, Seoul, Korea
14 shared publicationsChanghyeong Yoon
Center for Molecular Spectroscopy and Dynamics, Institute for Basic Science (IBS), Seoul 02841, South Korea
13 shared publications
Latest Publications
- 21 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (22) , 41425
Model-fitting perspective on the robustness and speed of CLASS in reflection matrix microscopy
Closed-loop accumulation of single scattering (CLASS) recovers the input and output pupil aberrations from intrinsic tissue reflections, even under strong multiple scattering. Its central principle is to maximize the correlation among the ballistic waves in a measured reflection matrix, so that elements sharing the same momentum transfer add coherently. Here we recast CLASS as the solution of a model-fitting problem. We show that correlation maximization is equivalent to a least-squares fit of the measured matrix to a separable forward model with two specific features. First, variable projection removes the object spectrum from the fitted parameters by folding it into the pupil-aberration update. Second, each group of matrix elements sharing the same momentum transfer is weighted in proportion to its size, so the fit favors higher-fidelity data. We then test this account by comparing CLASS against model fits that lack one or both of these features. For the comparison, we devised an experimental scheme that measures reflection matrices with the aberration and the multiple-scattering background controlled independently on a single target. Under increasing scattering and aberration, a fit that trains the object spectrum matches the reduced fit and CLASS once its object learning rate is scaled to the data; variable projection removes the need to choose this rate. Under reduced angular sampling, the unweighted fits work reliably only up to approximately 24% of the illumination angles removed, whereas CLASS, the multiplicity-weighted fit, keeps working up to 53%. CLASS stays accurate over the widest range and, in our implementation, converges fastest. We release these matrices as benchmark data.
- 21 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (22) , 41425
Model-fitting perspective on the robustness and speed of CLASS in reflection matrix microscopy
Closed-loop accumulation of single scattering (CLASS) recovers the input and output pupil aberrations from intrinsic tissue reflections, even under strong multiple scattering. Its central principle is to maximize the correlation among the ballistic waves in a measured reflection matrix, so that elements sharing the same momentum transfer add coherently. Here we recast CLASS as the solution of a model-fitting problem. We show that correlation maximization is equivalent to a least-squares fit of the measured matrix to a separable forward model with two specific features. First, variable projection removes the object spectrum from the fitted parameters by folding it into the pupil-aberration update. Second, each group of matrix elements sharing the same momentum transfer is weighted in proportion to its size, so the fit favors higher-fidelity data. We then test this account by comparing CLASS against model fits that lack one or both of these features. For the comparison, we devised an experimental scheme that measures reflection matrices with the aberration and the multiple-scattering background controlled independently on a single target. Under increasing scattering and aberration, a fit that trains the object spectrum matches the reduced fit and CLASS once its object learning rate is scaled to the data; variable projection removes the need to choose this rate. Under reduced angular sampling, the unweighted fits work reliably only up to approximately 24% of the illumination angles removed, whereas CLASS, the multiplicity-weighted fit, keeps working up to 53%. CLASS stays accurate over the widest range and, in our implementation, converges fastest. We release these matrices as benchmark data.
- Open Access
- 16 October 2026
- Published by Wiley in Nanophotonics
- Vol. 15 (20) , e70333
Interferometric Near‐Field Scanning Optical Microscopy via Phase Conjugation of a Multimode Fiber Probe
Interferometric near‐field scanning optical microscopy (NSOM) enables simultaneous measurement of both the amplitude and phase of the optical near field. In its aperture‐type implementation, the local field is collected through a sub‐wavelength aperture and an optical fiber. The choice of this fiber imposes an inherent trade‐off between signal strength and phase fidelity. Single‐mode fiber probes maintain phase fidelity but suffer from low signal intensity, whereas multimode fiber probes offer higher throughput but introduce severe phase distortions. Here, we present phase‐conjugation interferometric NSOM (PCI‐NSOM), which overcomes this limitation. The output field of the multimode fiber is measured by off‐axis holography, and its phase conjugate is displayed on a spatial light modulator, converting the scrambled speckle into a planar wavefront that focuses to a single point in Fourier space. At the focal pixel of the detector, the correction enhances the intensity by up to ∼165‐fold. We demonstrate PCI‐NSOM by imaging surface plasmon polaritons on a gold grating, obtaining accurate phase maps where uncorrected multimode collection fails through modal dispersion and single‐mode collection through a low signal‐to‐noise ratio. PCI‐NSOM thus provides a practical route to high‐sensitivity phase‐resolved nanoscale optical characterization.
- 16 October 2026
- Published by Wiley in Nanophotonics
- Vol. 15 (20) , e70333
Open AccessInterferometric Near‐Field Scanning Optical Microscopy via Phase Conjugation of a Multimode Fiber Probe
Interferometric near‐field scanning optical microscopy (NSOM) enables simultaneous measurement of both the amplitude and phase of the optical near field. In its aperture‐type implementation, the local field is collected through a sub‐wavelength aperture and an optical fiber. The choice of this fiber imposes an inherent trade‐off between signal strength and phase fidelity. Single‐mode fiber probes maintain phase fidelity but suffer from low signal intensity, whereas multimode fiber probes offer higher throughput but introduce severe phase distortions. Here, we present phase‐conjugation interferometric NSOM (PCI‐NSOM), which overcomes this limitation. The output field of the multimode fiber is measured by off‐axis holography, and its phase conjugate is displayed on a spatial light modulator, converting the scrambled speckle into a planar wavefront that focuses to a single point in Fourier space. At the focal pixel of the detector, the correction enhances the intensity by up to ∼165‐fold. We demonstrate PCI‐NSOM by imaging surface plasmon polaritons on a gold grating, obtaining accurate phase maps where uncorrected multimode collection fails through modal dispersion and single‐mode collection through a low signal‐to‐noise ratio. PCI‐NSOM thus provides a practical route to high‐sensitivity phase‐resolved nanoscale optical characterization.
- 23 September 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (10) , 5285-5298
Reflection matrix microscopy at 1.6 µm wavelength for label-free deep-tissue imaging
Multiple light scattering sets the depth limit of optical microscopy in biological tissue. Reflection matrix microscopy with the multiple-scattering tracing algorithm can overcome this scattering, but its application has so far been limited to wavelengths of 1.3 μm and below. Here, we develop, to our knowledge, the first reflection matrix microscope operating at 1.6 μm. By integrating it with a 1.3 μm channel into a single dual-wavelength system that isolates the wavelength as the principal variable, we quantitatively demonstrate that 1.6 μm markedly outperforms 1.3 μm. The reconstructed phase distortion in the mouse skull is weaker at 1.6 μm and the isoplanatic patch about 1.67 times larger. We resolve osteocytes lying beneath the strongly scattering bone marrow of the skull, a target unreachable at 1.3 μm.
- 23 September 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (10) , 5285-5298
Reflection matrix microscopy at 1.6 µm wavelength for label-free deep-tissue imaging
Multiple light scattering sets the depth limit of optical microscopy in biological tissue. Reflection matrix microscopy with the multiple-scattering tracing algorithm can overcome this scattering, but its application has so far been limited to wavelengths of 1.3 μm and below. Here, we develop, to our knowledge, the first reflection matrix microscope operating at 1.6 μm. By integrating it with a 1.3 μm channel into a single dual-wavelength system that isolates the wavelength as the principal variable, we quantitatively demonstrate that 1.6 μm markedly outperforms 1.3 μm. The reconstructed phase distortion in the mouse skull is weaker at 1.6 μm and the isoplanatic patch about 1.67 times larger. We resolve osteocytes lying beneath the strongly scattering bone marrow of the skull, a target unreachable at 1.3 μm.
- Open Access
- 4 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 2123
Dual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector with a camera from the conventional laser-scanning multiphoton microscope, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 μm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- 4 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 2123
Open AccessDual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector with a camera from the conventional laser-scanning multiphoton microscope, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 μm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- 16 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (1) , 294-304
Long-wavelength oblique back-illumination microscopy for deep in vivo imaging
Oblique back-illumination microscopy (OBM) is a label-free imaging technique that captures differential forward scattering in reflection mode to generate high-contrast pseudo-transmission images of cells and microvessels. While OBM benefits from multiple light scattering to detect forward-scattered signals, its imaging depth is constrained by tissue scattering between the objective lens and the imaging plane. In this study, we introduce a long-wavelength OBM system operating at 1650 nm—significantly longer than previous implementations—to mitigate scattering effects and extend imaging depth. Compared to a similar system using an 800 nm light source, our 1650 nm OBM achieves markedly deeper in vivo imaging of the mouse brain. This advancement in high-contrast, deep-tissue imaging holds promise for more detailed investigations into the pathophysiology of living biological systems.
- 16 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (1) , 294-304
Long-wavelength oblique back-illumination microscopy for deep in vivo imaging
Oblique back-illumination microscopy (OBM) is a label-free imaging technique that captures differential forward scattering in reflection mode to generate high-contrast pseudo-transmission images of cells and microvessels. While OBM benefits from multiple light scattering to detect forward-scattered signals, its imaging depth is constrained by tissue scattering between the objective lens and the imaging plane. In this study, we introduce a long-wavelength OBM system operating at 1650 nm—significantly longer than previous implementations—to mitigate scattering effects and extend imaging depth. Compared to a similar system using an 800 nm light source, our 1650 nm OBM achieves markedly deeper in vivo imaging of the mouse brain. This advancement in high-contrast, deep-tissue imaging holds promise for more detailed investigations into the pathophysiology of living biological systems.
- Open Access
- 1 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Holographic effect through full parallax multi-viewpoint augmented reality with extended depth of field
Augmented reality near eye display (AR NED) is highly promising for applications that integrate real-world environments with virtual imagery. However, their commercialization is currently limited by the vergence and accommodation conflict (VAC), which arises from the mismatch between binocular vergence depth and monocular focal depth. In this study, we show a holographic-like AR optical system that generates full parallax multi-viewpoint (FPMVP) with an extended depth of field, achieving sharp virtual images at the observer’s gaze depth and optical blur at other depths, without mechanical actuation or modification of optical components. This holographic-like visual effect effectively reduces VAC by providing monocular depth cues. Simultaneously, the extended depth of field of the FPMVP optical system enables resolution that satisfies the Rayleigh criterion over a broad range. The simple optical structure and excellent scalability of this technology demonstrate significant potential for future commercialization in the AR NED market.
- 1 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessHolographic effect through full parallax multi-viewpoint augmented reality with extended depth of field
Augmented reality near eye display (AR NED) is highly promising for applications that integrate real-world environments with virtual imagery. However, their commercialization is currently limited by the vergence and accommodation conflict (VAC), which arises from the mismatch between binocular vergence depth and monocular focal depth. In this study, we show a holographic-like AR optical system that generates full parallax multi-viewpoint (FPMVP) with an extended depth of field, achieving sharp virtual images at the observer’s gaze depth and optical blur at other depths, without mechanical actuation or modification of optical components. This holographic-like visual effect effectively reduces VAC by providing monocular depth cues. Simultaneously, the extended depth of field of the FPMVP optical system enables resolution that satisfies the Rayleigh criterion over a broad range. The simple optical structure and excellent scalability of this technology demonstrate significant potential for future commercialization in the AR NED market.
- Open Access
Imaging through volumetric scattering media by decoding angular light paths
High-resolution optical microscopy has transformed biological imaging, yet its resolution and contrast deteriorate with depth due to multiple light scattering. Conventional correction strategies typically approximate the medium as one or a few discrete layers. While effective in the presence of dominant scattering layers, these approaches break down in thick, volumetric tissues, where accurate modeling would require an impractically large number of layers. To address this challenge, we introduce an inverse-scattering framework that represents the entire volume as a superposition of angular deflectors, each corresponding to scattering at a specific angle. This angular formulation is particularly well suited to biological tissues, where narrow angular spread due to the dominant forward scattering allow most multiple scattering to be captured with relatively few components. Within this framework, we solve the inverse problem by progressively incorporating contributions from small to large deflection angles. Applied to simulations and in vivo reflection-mode imaging through intact mouse skull, our method reconstructs up to 121 angular components, converting ~80% of multiply scattered light into signal. This enables non-invasive visualization of osteocytes in the skull that remain inaccessible to existing layer-based methods. These results establish the scattering-angle basis as a deterministic framework for imaging through complex media, paving the way for high-resolution microscopy deep inside living tissues.
Open AccessImaging through volumetric scattering media by decoding angular light paths
High-resolution optical microscopy has transformed biological imaging, yet its resolution and contrast deteriorate with depth due to multiple light scattering. Conventional correction strategies typically approximate the medium as one or a few discrete layers. While effective in the presence of dominant scattering layers, these approaches break down in thick, volumetric tissues, where accurate modeling would require an impractically large number of layers. To address this challenge, we introduce an inverse-scattering framework that represents the entire volume as a superposition of angular deflectors, each corresponding to scattering at a specific angle. This angular formulation is particularly well suited to biological tissues, where narrow angular spread due to the dominant forward scattering allow most multiple scattering to be captured with relatively few components. Within this framework, we solve the inverse problem by progressively incorporating contributions from small to large deflection angles. Applied to simulations and in vivo reflection-mode imaging through intact mouse skull, our method reconstructs up to 121 angular components, converting ~80% of multiply scattered light into signal. This enables non-invasive visualization of osteocytes in the skull that remain inaccessible to existing layer-based methods. These results establish the scattering-angle basis as a deterministic framework for imaging through complex media, paving the way for high-resolution microscopy deep inside living tissues.
- Open Access
- 25 July 2025
- Published by Elsevier in Photoacoustics
- Vol. 45, 100753
All-optical in vivo photoacoustic tomography by adaptive multilayer acoustic backpropagation
- 25 July 2025
- Published by Elsevier in Photoacoustics
- Vol. 45, 100753
Open AccessAll-optical in vivo photoacoustic tomography by adaptive multilayer acoustic backpropagation
- Open Access
- 17 June 2025
- Published by Springer Nature in Research Square
Dual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector in a conventional laser-scanning multiphoton microscope with a camera, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 µm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- 17 June 2025
- Published by Springer Nature in Research Square
Open AccessDual deconvolution in multiphoton structured illumination microscopy for deep-tissue super-resolution imaging
Imaging in thick biological tissues is often degraded by sample-induced aberrations, which reduce resolution and contrast, particularly in super-resolution techniques. While hardware-based adaptive optics (AO) using wavefront shaping can correct these aberrations, their complexity and cost hinder widespread adoption. Here, we present a computational AO framework for multiphoton structured illumination microscopy, enabling deep-tissue super-resolution imaging with minimal hardware modifications. By replacing the photodetector in a conventional laser-scanning multiphoton microscope with a camera, we capture a sequence of scanned images. Using virtual structured illumination, we develop a dual deconvolution algorithm that independently corrects excitation and emission aberrations, recovering an aberration-free object spectrum with an extended spatial frequency bandwidth. We experimentally validate this framework through two-photon super-resolution imaging, achieving a lateral resolution of 130 nm—one-fourth of the emission wavelength—at a depth of 180 µm in thick mouse brain tissue, where conventional deconvolution fails to maintain super-resolution capability. This approach provides a cost-effective and accessible alternative to hardware-based AO, expanding the potential for high-resolution deep-tissue imaging in biological research.
- Open Access
- 14 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5514
A Lightweight Neural Network for Denoising Wrapped-Phase Images Generated with Full-Field Optical Interferometry
Phase wrapping is a common phenomenon in optical full-field imaging or measurement systems. It arises from large phase retardations and results in wrapped-phase maps that contain essential information about surface roughness and topology. However, these maps are often degraded by noise, such as speckle and Gaussian, which reduces the measurement accuracy and complicates phase reconstruction. Denoising such data is a fundamental problem in computer vision and plays a critical role in biomedical imaging modalities like Full-Field Optical Interferometry. In this paper, we propose WPD-Net (Wrapped-Phase Denoising Network), a lightweight deep learning-based neural network specifically designed to restore phase images corrupted by high noise levels. The network architecture integrates a shallow feature extraction module, a series of Residual Dense Attention Blocks (RDABs), and a dense feature fusion module. The RDABs incorporate attention mechanisms that help the network focus on critical features and suppress irrelevant noise, especially in high-frequency or complex regions. Additionally, WPD-Net employs a growth-rate-based feature expansion strategy to enhance multi-scale feature representation and improve phase continuity. We evaluate the model’s performance on both synthetic and experimentally acquired datasets and compare it with other state-of-the-art deep learning-based denoising methods. The results demonstrate that WPD-Net achieves superior noise suppression while preserving fine structural details even with mixed speckle and Gaussian noises. The proposed method is expected to enable fast image processing, allowing unwrapped biomedical images to be retrieved in real time.
- 14 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5514
Open AccessA Lightweight Neural Network for Denoising Wrapped-Phase Images Generated with Full-Field Optical Interferometry
Phase wrapping is a common phenomenon in optical full-field imaging or measurement systems. It arises from large phase retardations and results in wrapped-phase maps that contain essential information about surface roughness and topology. However, these maps are often degraded by noise, such as speckle and Gaussian, which reduces the measurement accuracy and complicates phase reconstruction. Denoising such data is a fundamental problem in computer vision and plays a critical role in biomedical imaging modalities like Full-Field Optical Interferometry. In this paper, we propose WPD-Net (Wrapped-Phase Denoising Network), a lightweight deep learning-based neural network specifically designed to restore phase images corrupted by high noise levels. The network architecture integrates a shallow feature extraction module, a series of Residual Dense Attention Blocks (RDABs), and a dense feature fusion module. The RDABs incorporate attention mechanisms that help the network focus on critical features and suppress irrelevant noise, especially in high-frequency or complex regions. Additionally, WPD-Net employs a growth-rate-based feature expansion strategy to enhance multi-scale feature representation and improve phase continuity. We evaluate the model’s performance on both synthetic and experimentally acquired datasets and compare it with other state-of-the-art deep learning-based denoising methods. The results demonstrate that WPD-Net achieves superior noise suppression while preserving fine structural details even with mixed speckle and Gaussian noises. The proposed method is expected to enable fast image processing, allowing unwrapped biomedical images to be retrieved in real time.