Christian. R. Engst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christian. R. Engst has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Kutter
Fraunhofer Institute for Electronic Microsystems and Solid State Technologies, 80686 Munich, Germany
3 shared publications - Tim Liedl
Faculty of Physics and Center for NanoScience (CeNS), Ludwig-Maximilians-Universität München, Munich, Germany
3 shared publications - Ignaz Eisele
Fraunhofer Institute for Electronic Microsystems and Solid State Technologies EMFT, 80686 Munich, Germany
2 shared publications - Silvia Hernández-Ainsa
Instituto de Nanociencia y Materiales de Aragón (INMA), CSIC-Universidad de Zaragoza, Zaragoza, Spain
2 shared publications C. Bscheid
Fraunhofer Research Institution for Microsystems and Solid State Technologies (EMFT) 1 , Hansastrasse 27d, 80686 Munich, Germany
1 shared publication- Caterina Ducati
University of Cambridge
1 shared publication
Latest Publications
- Open Access
- 17 January 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (3) , 035704
Defect characterization of unannealed neutron transmutation doped silicon by means of deep temperature microwave detected photo induced current transient spectroscopy
Unannealed neutron transmutation doped silicon substrates with a target resistivity of approximately are characterized for radiation induced defects by means of microwave detected photoinduced current transient spectroscopy (MD-PICTS). This technique is a contactless advancement of conventional PICTS and does not require the fabrication of ohmic contacts. Defect spectroscopy by means of MD-PICTS is conducted in a broad temperature range between 30 K and 293 K, which makes it possible to identify energetically shallow as well as deep traps. In addition, a wavelength dependent analysis is performed to determine whether a defect is located at the surface or in the bulk material. Three traps with an average activation energy of , , and are observed. In addition, an indication for deep defect states with activation energies between and is found. According to the wavelength dependent analysis, it is assumed that all observed traps are bulk defects. Finally, a minority carrier lifetime of approximately 0.7 μs is determined, suggesting that the crystal is heavily damaged by neutron radiation.- 17 January 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (3) , 035704
Open AccessDefect characterization of unannealed neutron transmutation doped silicon by means of deep temperature microwave detected photo induced current transient spectroscopy
Unannealed neutron transmutation doped silicon substrates with a target resistivity of approximately are characterized for radiation induced defects by means of microwave detected photoinduced current transient spectroscopy (MD-PICTS). This technique is a contactless advancement of conventional PICTS and does not require the fabrication of ohmic contacts. Defect spectroscopy by means of MD-PICTS is conducted in a broad temperature range between 30 K and 293 K, which makes it possible to identify energetically shallow as well as deep traps. In addition, a wavelength dependent analysis is performed to determine whether a defect is located at the surface or in the bulk material. Three traps with an average activation energy of , , and are observed. In addition, an indication for deep defect states with activation energies between and is found. According to the wavelength dependent analysis, it is assumed that all observed traps are bulk defects. Finally, a minority carrier lifetime of approximately 0.7 μs is determined, suggesting that the crystal is heavily damaged by neutron radiation. - Open Access
Minority Carrier Lifetime Measurements for Contactless Oxidation Process Characterization and Furnace Profiling
Contactless minority carrier lifetime (lifetime) measurements by means of microwave detected photoconductivity are employed for oxidation process characterization and furnace profiling. Characterization is performed on oxidized float zone substrates with high resistivity and outstanding bulk quality, suggesting that the measured effective lifetime is strongly dominated by interface recombination and therefore reflects the oxide quality. The applied approach requires neither test structures nor time consuming measurements and is therefore of particular interest if high throughput is required. The method is used to investigate the impact of oxidation furnace leakage as well as to analyze the oxidation homogeneity across a horizontal oxidation furnace. For comparison, capacitance-voltage measurements are conducted to characterize the oxide properties. It is found that any type of furnace leakage, which induces fixed oxide charges as well as interface states, has a heavy impact on the measured effective lifetime, especially on the shape of generation rate dependent lifetime curves. Furthermore, a distinct lifetime decrease towards the tube door of the oxidation furnace could be observed. The latter is even detectable in an ideal oxidation process, generating high quality oxides. Besides plain equipment characterization, the presented approach is suitable to optimize the oxidation process itself regarding different parameters like temperature, gas flow, pressure, or process time.
Open AccessMinority Carrier Lifetime Measurements for Contactless Oxidation Process Characterization and Furnace Profiling
Contactless minority carrier lifetime (lifetime) measurements by means of microwave detected photoconductivity are employed for oxidation process characterization and furnace profiling. Characterization is performed on oxidized float zone substrates with high resistivity and outstanding bulk quality, suggesting that the measured effective lifetime is strongly dominated by interface recombination and therefore reflects the oxide quality. The applied approach requires neither test structures nor time consuming measurements and is therefore of particular interest if high throughput is required. The method is used to investigate the impact of oxidation furnace leakage as well as to analyze the oxidation homogeneity across a horizontal oxidation furnace. For comparison, capacitance-voltage measurements are conducted to characterize the oxide properties. It is found that any type of furnace leakage, which induces fixed oxide charges as well as interface states, has a heavy impact on the measured effective lifetime, especially on the shape of generation rate dependent lifetime curves. Furthermore, a distinct lifetime decrease towards the tube door of the oxidation furnace could be observed. The latter is even detectable in an ideal oxidation process, generating high quality oxides. Besides plain equipment characterization, the presented approach is suitable to optimize the oxidation process itself regarding different parameters like temperature, gas flow, pressure, or process time.
- 6 December 2017
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 122 (21)
Bulk lifetime characterization of corona charged silicon wafers with high resistivity by means of microwave detected photoconductivity
Minority carrier lifetime (lifetime) measurements are performed on corona-charged silicon wafers by means of Microwave Detected Photoconductivity (MDP). The corona charge is deposited on the front and back sides of oxidized wafers in order to adjust accumulation conditions. Once accumulation is established, interface recombination is suppressed and bulk lifetimes are obtained. Neither contacts nor non-CMOS compatible preparation techniques are required in order to achieve accumulation conditions, which makes the method ideally suited for inline characterization. The novel approach, termed ChargedMDP (CMDP), is used to investigate neutron transmutation doped (NTD) float zone silicon with resistivities ranging from 6.0 to 8.2 kΩ cm. The bulk properties of 150 mm NTD wafers are analyzed in detail by performing measurements of the carrier lifetime and the steady-state photoconductivity at various injection levels. The results are compared with MDP measurements of uncharged wafers as well as to the established charged microwave detected Photoconductance Decay (charge-PCD) method. Besides analyzing whole wafers, CMDP measurements are performed on oxide test-structures on a patterned wafer. Finally, the oxide properties are characterized by means of charge-PCD as well as capacitance-voltage measurements. With CMDP, average bulk lifetimes up to 33.1 ms are measured, whereby significant variations are observed among wafers, which are produced out of the same ingot but oxidized in different furnaces. The observed lifetime variations are assumed to be caused by contaminations, which are introduced during the oxidation process. The results obtained by CMDP were neither accessible by means of conventional MDP measurements of uncharged wafers nor with the established charge-PCD method.
- 6 December 2017
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 122 (21)
Bulk lifetime characterization of corona charged silicon wafers with high resistivity by means of microwave detected photoconductivity
Minority carrier lifetime (lifetime) measurements are performed on corona-charged silicon wafers by means of Microwave Detected Photoconductivity (MDP). The corona charge is deposited on the front and back sides of oxidized wafers in order to adjust accumulation conditions. Once accumulation is established, interface recombination is suppressed and bulk lifetimes are obtained. Neither contacts nor non-CMOS compatible preparation techniques are required in order to achieve accumulation conditions, which makes the method ideally suited for inline characterization. The novel approach, termed ChargedMDP (CMDP), is used to investigate neutron transmutation doped (NTD) float zone silicon with resistivities ranging from 6.0 to 8.2 kΩ cm. The bulk properties of 150 mm NTD wafers are analyzed in detail by performing measurements of the carrier lifetime and the steady-state photoconductivity at various injection levels. The results are compared with MDP measurements of uncharged wafers as well as to the established charged microwave detected Photoconductance Decay (charge-PCD) method. Besides analyzing whole wafers, CMDP measurements are performed on oxide test-structures on a patterned wafer. Finally, the oxide properties are characterized by means of charge-PCD as well as capacitance-voltage measurements. With CMDP, average bulk lifetimes up to 33.1 ms are measured, whereby significant variations are observed among wafers, which are produced out of the same ingot but oxidized in different furnaces. The observed lifetime variations are assumed to be caused by contaminations, which are introduced during the oxidation process. The results obtained by CMDP were neither accessible by means of conventional MDP measurements of uncharged wafers nor with the established charge-PCD method.
- 1 January 2013
- Published by Elsevier in Biophysical Journal
- Vol. 104 (2) , 517a-517A
DNA Origami Nanopores
- 1 January 2013
- Published by Elsevier in Biophysical Journal
- Vol. 104 (2) , 517a-517A
DNA Origami Nanopores
- 20 December 2012
- Published by Taylor & Francis in Nanomedicine
- Vol. 8 (1) , 105-121
Nucleic Acid Nanostructures for Biomedical Applications
We review the current developments of DNA-based nanostructures for drug delivery, immunotherapy, diagnostics and molecular biology. DNA is a powerful building block, which by the nature of predictable base pairing, allows the creation of molecular scaffolds, cages and multifunctional carriers with nanoscale dimensions. These engineered constructs have unsurpassed structural qualities such as full control over size, shape and dispersity. Site-specific surface modification enables the presentation of biomolecules at defined distances and stochiometries, which allows tailored cell targeting and substance delivery on demand. As the first successful in vivo applications of DNA nanostructures have recently been demonstrated, we now expect a burst of biomedical studies involving this rapidly progressing technology.
- 20 December 2012
- Published by Taylor & Francis in Nanomedicine
- Vol. 8 (1) , 105-121
Nucleic Acid Nanostructures for Biomedical Applications
We review the current developments of DNA-based nanostructures for drug delivery, immunotherapy, diagnostics and molecular biology. DNA is a powerful building block, which by the nature of predictable base pairing, allows the creation of molecular scaffolds, cages and multifunctional carriers with nanoscale dimensions. These engineered constructs have unsurpassed structural qualities such as full control over size, shape and dispersity. Site-specific surface modification enables the presentation of biomolecules at defined distances and stochiometries, which allows tailored cell targeting and substance delivery on demand. As the first successful in vivo applications of DNA nanostructures have recently been demonstrated, we now expect a burst of biomedical studies involving this rapidly progressing technology.
- 5 September 2012
- Published by Royal Society of Chemistry (RSC)
- p. 1-4
Ionic Current Detection of DNA Origami Nanostructures with Nanocapillaries
DNA origami is a powerful technique for the construction of designer nanopores. Nanocapillaries can be used both to detect the translocation of DNA origami structures and to trap the origami to form a hybrid pore by tuning the diameter of the nanopore. The detection of translocations is a potential new tool for assessing the folding quality and aggregation of DNA origami in solution. The formation of a hybrid origami-nanocapillary nanopore represents a novel method for creating hybrid nanopores with high throughput and low cost.
- 5 September 2012
- Published by Royal Society of Chemistry (RSC)
- p. 1-4
Ionic Current Detection of DNA Origami Nanostructures with Nanocapillaries
DNA origami is a powerful technique for the construction of designer nanopores. Nanocapillaries can be used both to detect the translocation of DNA origami structures and to trap the origami to form a hybrid pore by tuning the diameter of the nanopore. The detection of translocations is a potential new tool for assessing the folding quality and aggregation of DNA origami in solution. The formation of a hybrid origami-nanocapillary nanopore represents a novel method for creating hybrid nanopores with high throughput and low cost.
- 23 December 2011
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 12 (1) , 512-517
DNA Origami Nanopores
We demonstrate the assembly of functional hybrid nanopores for single molecule sensing by inserting DNA origami structures into solid-state nanopores. In our experiments, single artificial nanopores based on DNA origami are repeatedly inserted in and ejected from solid-state nanopores with diameters around 15 nm. We show that these hybrid nanopores can be employed for the detection of λ-DNA molecules. Our approach paves the way for future development of adaptable single-molecule nanopore sensors based on the combination of solid-state nanopores and DNA self-assembly.
- 23 December 2011
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 12 (1) , 512-517
DNA Origami Nanopores
We demonstrate the assembly of functional hybrid nanopores for single molecule sensing by inserting DNA origami structures into solid-state nanopores. In our experiments, single artificial nanopores based on DNA origami are repeatedly inserted in and ejected from solid-state nanopores with diameters around 15 nm. We show that these hybrid nanopores can be employed for the detection of λ-DNA molecules. Our approach paves the way for future development of adaptable single-molecule nanopore sensors based on the combination of solid-state nanopores and DNA self-assembly.