Jacques Hameury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jacques Hameury has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Hay
Laboratoire National de Métrologie et d'Essais (LNE), Paris, France
6 shared publications - Jean Remy Filtz
Laboratoire national de métrologie et d’essais (LNE)
4 shared publications B. Hay
3 shared publicationsV. Scoarnec
2 shared publicationsA. Blanchin
1 shared publicationA. Koenen
Laboratoire National de Métrologie et d’essais
1 shared publication
Latest Publications
- Open Access
- 15 June 2021
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 10 (1) , 135-152
Assessment of uncertainties for measurements of total near-normal emissivity of low-emissivity foils with an industrial emissometer
The TIR100-2 emissometer (manufactured by Inglas GmbH & Co.KG) is an emissivity measurement device used by several producers of thermal insulation products for buildings and by some organizations certifying performance of insulation products. A comparison of emissivity measurements on low-emissivity foils involving different measurement techniques, including the TIR100-2 emissometer, gave widely dispersed results; the discrepancies were not explained. The metrological performance of the TIR100-2 emissometer and the uncertainties for measurement on reflective foils was not known, which could be detrimental to users. In order to quantify the performance of TIR100-2 devices for measurement of total near-normal emissivity of low-emissivity foils, the Laboratoire National de Métrologie et d'Essais (LNE) analyzed in detail the measuring principle and listed the associated assumptions and uncertainty sources. A TIR100-2 emissometer actually measures the reflectance and, for opaque materials, the emissivity is calculated from the measured reflectance. The parameters analyzed experimentally are the temperature stability and uniformity of the thermal radiation source, the emissivity of the radiation source, the response function linearity and the spectral sensitivity of the radiometric detection system measuring the reflected radiation, the size of the measurement area, and the measurement repeatability and reproducibility. A detailed uncertainty budget was established. The uncertainty sources taken into account are the uncertainties of the emissivities of the two calibrated standards used for calibration, the stability and uniformity of the radiation source temperature, the non-linearity and the spectral sensitivity of the radiometric detection system, the specific measurement condition related to the radiation source temperature, the uncertainties related to the temperatures of the standards and the sample, the noises on results, and the non-homogeneity in emissivity of the tested material. The combined measurement uncertainty was calculated for different types of reflective foils; the expanded uncertainty is around 0.03 for total near-normal emissivity measurements on smooth low-emissivity foils. A measurement campaign on five types of low-emissivity foils, involving four TIR100-2 emissometers, and a comparison to a primary reference setup at the Physikalisch-Technische Bundesanstalt (PTB) confirmed the uncertainties assessed.
- 15 June 2021
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 10 (1) , 135-152
Open AccessAssessment of uncertainties for measurements of total near-normal emissivity of low-emissivity foils with an industrial emissometer
The TIR100-2 emissometer (manufactured by Inglas GmbH & Co.KG) is an emissivity measurement device used by several producers of thermal insulation products for buildings and by some organizations certifying performance of insulation products. A comparison of emissivity measurements on low-emissivity foils involving different measurement techniques, including the TIR100-2 emissometer, gave widely dispersed results; the discrepancies were not explained. The metrological performance of the TIR100-2 emissometer and the uncertainties for measurement on reflective foils was not known, which could be detrimental to users. In order to quantify the performance of TIR100-2 devices for measurement of total near-normal emissivity of low-emissivity foils, the Laboratoire National de Métrologie et d'Essais (LNE) analyzed in detail the measuring principle and listed the associated assumptions and uncertainty sources. A TIR100-2 emissometer actually measures the reflectance and, for opaque materials, the emissivity is calculated from the measured reflectance. The parameters analyzed experimentally are the temperature stability and uniformity of the thermal radiation source, the emissivity of the radiation source, the response function linearity and the spectral sensitivity of the radiometric detection system measuring the reflected radiation, the size of the measurement area, and the measurement repeatability and reproducibility. A detailed uncertainty budget was established. The uncertainty sources taken into account are the uncertainties of the emissivities of the two calibrated standards used for calibration, the stability and uniformity of the radiation source temperature, the non-linearity and the spectral sensitivity of the radiometric detection system, the specific measurement condition related to the radiation source temperature, the uncertainties related to the temperatures of the standards and the sample, the noises on results, and the non-homogeneity in emissivity of the tested material. The combined measurement uncertainty was calculated for different types of reflective foils; the expanded uncertainty is around 0.03 for total near-normal emissivity measurements on smooth low-emissivity foils. A measurement campaign on five types of low-emissivity foils, involving four TIR100-2 emissometers, and a comparison to a primary reference setup at the Physikalisch-Technische Bundesanstalt (PTB) confirmed the uncertainties assessed.
- 25 November 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (1) , 16
Identification and Characterization of New Materials for Construction of Heating Plates for High-Temperature Guarded Hot Plates
- 25 November 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 39 (1) , 16
Identification and Characterization of New Materials for Construction of Heating Plates for High-Temperature Guarded Hot Plates
- 10 April 2014
- Published by EDP Sciences in Revue française de métrologie
- No. 33,p. 29-38
Développement d’un réflectomètre absolu pour l’étalonnage de miroirs dans l’infrarouge
- 10 April 2014
- Published by EDP Sciences in Revue française de métrologie
- No. 33,p. 29-38
Développement d’un réflectomètre absolu pour l’étalonnage de miroirs dans l’infrarouge
- 7 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (4) , 2112-2119
Traceability Improvement of High Temperature Thermal Property Measurements of Materials for New Fission Reactors
New metrological facilities for high temperature measurements of thermophysical properties have been recently developed by European National Metrology Institutes (NMIs). This work, performed in the framework of the joint research project “MetroFission”, aims to provide reliable measurements up to 2000 for materials having thermal properties similar to those required for design of new generations of fission reactors. This will enable to improve the traceability to the International System of Units (SI) of measurements performed by nuclear research laboratories. The validation of these reference apparatuses was done at high temperature by measuring the thermal diffusivity and normal spectral emissivity of an isostatic graphite and pure tungsten.
- 7 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (4) , 2112-2119
Traceability Improvement of High Temperature Thermal Property Measurements of Materials for New Fission Reactors
New metrological facilities for high temperature measurements of thermophysical properties have been recently developed by European National Metrology Institutes (NMIs). This work, performed in the framework of the joint research project “MetroFission”, aims to provide reliable measurements up to 2000 for materials having thermal properties similar to those required for design of new generations of fission reactors. This will enable to improve the traceability to the International System of Units (SI) of measurements performed by nuclear research laboratories. The validation of these reference apparatuses was done at high temperature by measuring the thermal diffusivity and normal spectral emissivity of an isostatic graphite and pure tungsten.
- 7 June 2012
- Published by EDP Sciences in Revue française de métrologie
- No. 28,p. 17-24
Caractérisation radiative de liquides volatils semi-transparents dans le domaine infrarouge
- 7 June 2012
- Published by EDP Sciences in Revue française de métrologie
- No. 28,p. 17-24
Caractérisation radiative de liquides volatils semi-transparents dans le domaine infrarouge
- 3 December 2011
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 32 (11-12) , 2741-2751
Thermophysical Properties of Materials: New Metrology Challenges at LNE to Reduce the Uncertainties
- 3 December 2011
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 32 (11-12) , 2741-2751
Thermophysical Properties of Materials: New Metrology Challenges at LNE to Reduce the Uncertainties
- 31 January 2009
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 30 (4) , 1270-1282
Thermal-Diffusivity Measurement of Ceramic Coatings at High Temperature using “Front-Face” and “Rear-Face” Laser Flash Methods
- 31 January 2009
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 30 (4) , 1270-1282
Thermal-Diffusivity Measurement of Ceramic Coatings at High Temperature using “Front-Face” and “Rear-Face” Laser Flash Methods
- 26 July 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (5) , 1607-1620
Measurement of Total Hemispherical Emissivity Using a Calorimetric Technique
- 26 July 2007
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 28 (5) , 1607-1620
Measurement of Total Hemispherical Emissivity Using a Calorimetric Technique
- 1 November 2005
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 26 (6) , 1973-1983
Measurement of Infrared Spectral Directional Hemispherical Reflectance and Emissivity at BNM-LNE
- 1 November 2005
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 26 (6) , 1973-1983
Measurement of Infrared Spectral Directional Hemispherical Reflectance and Emissivity at BNM-LNE