MBMattia Bacca

Mattia Bacca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mattia Bacca has a total of 80 co-authors. Here are the top co-authors by number of shared publications:

  • Stefano Fregonese

    Mechanical Engineering Department University of British Columbia BC V6T1Z4 Vancouver Canada

    5 shared publications
  • Bharath Antarvedi Goda

    4 shared publications
  • Gwynn J. Elfring

    Mechanical Engineering Department, University of British Columbia

    4 shared publications
  • Albert Kong

    Mechanical Engineering Department, University of British Columbia

    3 shared publications
  • Albert Kong

    Mechanical Engineering Department, Institute of Applied Mathematics, School of Biomedical Engineering, University of British Columbia , Vancouver, BC V6T 1Z4, Canada

    3 shared publications
  • Matteo Ferraresso

    Department of Mechanical Engineering, University of British Columbia, Vancouver, V6T1Z4, Canada; Versiti Blood Research Institute, Milwaukee, WI, 53226, United States; Institute of Applied Mathematics, Vancouver, V6T1Z2, Canada; School of Biomedical Engineering, University of British Columbia, Vancouver, V6T2B9, Canada

    3 shared publications

Latest Publications

  • Open Access

    Deep Indentation of Hyperelastic Materials Reveals Tip-Independent Parabolic Force–Depth Response via Strain-Energy Delocalization

    by Mohammad Shojaeifard, Zhenwei Ma, K. Jimmy Hsia, Norman Fleck, Mattia Bacca

    Indentation is a practical route for probing the mechanical properties of soft materials when standard tests are difficult, destructive, or simply cannot be performed in situ. However, conventional indentation is usually interpreted in the shallow-depth regime, where the indentation depth $D$ is small compared with the indenter radius $R$. In this limit, the response is controlled by local contact geometry and primarily identifies the small-strain elastic (Young's) modulus $E$. For example, flat-punch indentation of an incompressible elastomer produces the indentation force $F=(8/3)ERD$, as given by Sneddon theory, while a spherical-tipped indenter requires $F=(16/9)ER^{1/2}D^{3/2}$, as given by Hertz theory. Conversely, at deep indentation, for $D\gg R$, the indentation response converges to the same parabolic force--depth law, $F=\beta E D^2$, for both indenter tip shapes, where $\beta$ is a dimensionless coefficient controlled by the hyperelastic behavior of the material and increasing with strain stiffening. We show that $\beta$ is only mildly affected by interfacial friction, while independent of indenter radius and tip shape. We show that the parabolic scaling arises from strain-energy delocalization: as indentation depth increases, the region where the strain energy density satisfies $\mathrm{SED}/\mu>0.01$ expands into a spheroidal domain whose effective radius scales with $D$. The activated volume therefore scales as $D^3$, giving the total stored elastic energy as $U\sim E D^3$, so that $F=dU/dD\sim E D^2$. Far from the contact, the finite-element strain-energy-density fields collapse and approach the Boussinesq far-field solution when distances are normalized by the strain-energy delocalization length $a=\sqrt{F/E}$, which scales as $a\sim D$ in the deep-indentation regime. This provides a mechanistic basis for the growth of the activated region and the loss of tip-shape dependence. Finally, these results link $\beta$ to the Ogden strain-stiffening parameter $\alpha$ for incompressible materials, enabling hyperelastic parameter extraction from deep-indentation data.


  • Contraction of blood clots occurs during hemostasis and hemorrhagic shock to promote closure of lacerations

    by Matteo Ferraresso, Nabil Ali-Mohamad, Massimo F. Cau, Monica Seadler, Halen Turner, Francesca Ferraresso, Youjie Zhang, Thomas W. Carver, Chandrasekaran Nagaswami, Andrew Beckett, et al.


  • Open Access

    Hollow Needle Puncture Mechanics for Biopsy Sampling

    by Yiting Wu, Frederich Lechernaut, Matteo Ciccotti, Mattia Bacca

    Biopsy sampling relies on hollow needles that puncture soft tissues by propagating and opening acylindrical crack, yet the mechanics governing this coring process remain only partiallyunderstood. Motivated by this gap, we develop a simple, energy-based model for puncture by blunthollow needles, grounded in brittle fracture mechanics and extended to include frictionalinteractions at the needle–tissue interface. The model describes puncture as the competitionbetween the fracture energy and the elastic energy. This energetic balance is controlled by theinterplay among needle geometry (radius and wall thickness), material properties (toughness andelastic modulus), and interfacial parameters (adhesion and friction). This model provides semi-analytical predictions for five key quantities: core size, frictionless force, frictional force slope,critical insertion depth, and critical insertion force. Model predictions are validated againstexperiments, demonstrating that friction significantly improves force estimation and alters thepuncture regime. These results offer quantitative insight into the mechanics of tissue coring andforce generation during biopsy, providing a predictive foundation for needle design, samplingperformance, and real-time control in robotic biopsy and needle-insertion systems.

  • Open Access

    Adhesive strength of bio-inspired fibrillar arrays in the presence of contact defects

    by Agostinelli Daniele, Shojaeifard Mohammad, Bacca Mattia

    The performance of bio-inspired fibrillar adhesives can be compromised by surface roughness, manufacturing imperfections or impurities. Previous studies investigated the cases of distributed defects on the array, and defects at the level of single fibrils. However, the influence of localized, macroscopic defects remains largely unexplored. Using numerical simulations of a discrete mechanical model for a fibrillar adhesive with a thick backing layer, we investigate how the size and location of a single circular defect affect the established scaling law between the adhesion force ($F$) and the effective compliance of the system ($β$), \ie, $F \propto β^{-1/2}$. We find that edge defects are generally more detrimental than central ones, as they act as pre-cracks that amplify stress concentrations at the adhesive's edge, accelerating a crack-like failure. Consequently, the established adhesion scaling law is preserved, with the defect only reducing the effective contact area. In contrast, a central defect fundamentally alters the mechanics of detachment. By transforming the contact geometry into an annulus, it promotes more uniform load sharing across the remaining fibrils and mitigates the edge-dominated failure mechanism. This change makes the adhesive strength less sensitive to the compliance of the system, as reflected by a less negative scaling exponent. The transition between these two regimes appears to occur for defects whose boundary merges with the one of the adhesive. These results provide practical guidance for the design, engineering and quality control of bio-inspired fibrillar adhesives.

  • Open Access

    Hyperelastic characterization via deep indentation

    by Mohammad Shojaeifard, Mattia Bacca

    Hyperelastic material characterization is crucial for understanding the behavior of soft materials—such as tissues, rubbers, hydrogels, and polymers—under quasi-static loading before failure.


  • Open Access

    Behavioural biomechanics: leaf-cutter ant cutting behaviour depends on leaf edge geometry

    by Frederik Püffel, Victor Kang, Mia Yap, Mohammad Shojaeifard, Mattia Bacca, David Labonte

    Leaf-cutter ants cut fresh leaves to grow a symbiotic fungus as crop. During cutting, one mandible is typically anchored onto the leaf lamina while the other slices through it like a knife. When initiating cuts into the leaf edge, however, foragers sometimes deviate from this behaviour and instead use their mandibles symmetrically, akin to scissors. In vivo behavioural assays revealed that the preference for either of the two cutting strategies depended on leaf edge geometry and differed between natural leaf margins that were straight or serrated with notch-like folds: leaf-cutter ants displayed a strong preference for scissor-cutting when leaf edges were straight or had wide notches. This preference, however, reversed in favour of knife-cutting when notches were narrow. To investigate whether this behavioural difference had a mechanical origin, we mimicked knife-cutting in ex vivo cutting experiments: for wide notches, all but the sharpest mandibles failed to initiate cuts, or only did so at large forces, caused by substantial leaf buckling and bending. This increased force demand would substantially limit the ability of foragers to cut leaves, and so reduce the colony’s access to food sources. Scissor-cutting may thus be an adaptation to the mechanical difficulties associated with bending and buckling of thin leaves.


  • Open Access

    Machine learning-based optimal design of fibrillar adhesives

    by Mohammad Shojaeifard, Matteo Ferraresso, Alessandro Lucantonio, Mattia Bacca

    Fibrillar adhesion, observed in animals like beetles, spiders and geckos, relies on nanoscopic or microscopic fibrils to enhance surface adhesion via ‘contact splitting’. This concept has inspired engineering applications across robotics, transportation and medicine. Recent studies suggest that functional grading of fibril properties can improve adhesion, but this is a complex design challenge that has only been explored in simplified geometries. While machine learning (ML) has gained traction in adhesive design, no previous attempts have targeted fibril-array scale optimization. In this study, we propose an ML-based tool that optimizes the distribution of fibril compliance to maximize adhesive strength. Our tool, featuring two neural networks (NNs), recovers previous design results for simple geometries and introduces novel solutions for complex configurations. The predictor NN estimates adhesive strength based on random compliance distributions, while the designer NN optimizes compliance distribution to achieve maximum strength using gradient-based optimization. This method significantly reduces test error and accelerates the optimization process, offering a high-performance solution for designing fibrillar adhesives and micro-architected materials aimed at fracture resistance by achieving equal load sharing.