Tzu-Chieh Chou
Research Subjects
Tzu-Chieh Chou has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Yu-Chong Tai
Department of Electrical Engineering, California Institute of Technology, USA
4 shared publications- Han-Wen Hu
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
2 shared publications - Kuan-Neng Chen
National yang Ming Chiao Tung University
2 shared publications Amin Arbabian
Department of Electrical Engineering at Stanford University, Stanford, CA 94305 USA
1 shared publicationArvind Sundarrajan
Applied Packaging Development Center, Applied Materials, Inc., Singapore
1 shared publicationBo Han
Department of Surgery, University of Southern California, 1450 San Pablo Street, Healthcare Consultation Center 4, Suite 6200, Los Angeles, CA, 90089, USA
1 shared publication
Latest Publications
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 52 2, 377-382
Low Temperature Cu-Cu Bonding with Electroless Deposited Metal Passivation for Fine-Pitch 3D Packaging
In this study, electroplated Cu-Cu bonding with electroless plating passivation on Cu surface can be achieved at a low bonding temperature. Compared with other low temperature bonding schemes, electroplated Cu and electroless plated passivation in this work is time-saving, high throughput, and high yield. After a pretreatment process, chip-level bonding with the good bonding quality can be achieved at 180°C under atmosphere. The morphology of the electroless plated passivation surface was characterized by the energy dispersive X-ray spectroscopy (EDX), and the bonding quality was investigated by the analyses of scanning electron microscope (SEM). In addition, electrical measurements were performed to evaluate the electrical properties of the bonding structure.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 52 2, 377-382
Low Temperature Cu-Cu Bonding with Electroless Deposited Metal Passivation for Fine-Pitch 3D Packaging
In this study, electroplated Cu-Cu bonding with electroless plating passivation on Cu surface can be achieved at a low bonding temperature. Compared with other low temperature bonding schemes, electroplated Cu and electroless plated passivation in this work is time-saving, high throughput, and high yield. After a pretreatment process, chip-level bonding with the good bonding quality can be achieved at 180°C under atmosphere. The morphology of the electroless plated passivation surface was characterized by the energy dispersive X-ray spectroscopy (EDX), and the bonding quality was investigated by the analyses of scanning electron microscope (SEM). In addition, electrical measurements were performed to evaluate the electrical properties of the bonding structure.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 700-705
Investigation of Wet Pretreatment to Improve Cu-Cu Bonding for Hybrid Bonding Applications
The main development challenge of low temperature hybrid bonding technology is the oxidation of Cu surface. The schemes to achieve the high-quality surface condition of Cu before bonding is urgently demanded. In this study, four acid solutions, including sulfuric acid (H2SO4), hydrochloric acid (HCl), acetic acid (CH3COOH) and citric acid (C6H8O7), were chosen as wet pretreatment approaches to remove Cu oxides based on the respective chemical reactions. To investigate the influence of these acid solutions on bonding surface, different acid immersion times are examined and the XPS analysis is conducted to check the surface component composition. Next, thermal compression bonding (TCB) is conducted after the Cu oxide removal process, followed by various analyses, including SAT analysis to validate bonding results, FIB and SEM analyses to inspect bonding interface, and pull test to measure bonding strength. The results of analyses verify the ability of different wet pretreatment to improve Cu-Cu bonding.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 700-705
Investigation of Wet Pretreatment to Improve Cu-Cu Bonding for Hybrid Bonding Applications
The main development challenge of low temperature hybrid bonding technology is the oxidation of Cu surface. The schemes to achieve the high-quality surface condition of Cu before bonding is urgently demanded. In this study, four acid solutions, including sulfuric acid (H2SO4), hydrochloric acid (HCl), acetic acid (CH3COOH) and citric acid (C6H8O7), were chosen as wet pretreatment approaches to remove Cu oxides based on the respective chemical reactions. To investigate the influence of these acid solutions on bonding surface, different acid immersion times are examined and the XPS analysis is conducted to check the surface component composition. Next, thermal compression bonding (TCB) is conducted after the Cu oxide removal process, followed by various analyses, including SAT analysis to validate bonding results, FIB and SEM analyses to inspect bonding interface, and pull test to measure bonding strength. The results of analyses verify the ability of different wet pretreatment to improve Cu-Cu bonding.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1245-1248
A new method to manufacture parylene microcapillaries
A new way to fabricate extremely long and uniform Parylene microcapillaries with a minimum inner diameter of 3 μm and a length exceeding 30 cm is reported here. The method starts with drawing sacrificial poly(ethylene carbonate) (PEC) fibers from its chloroform solution and then forms hollow capillaries by coating the fibers with Parylene and removing the sacrificial PEC at its thermolytic temperature. For the fiber drawing, the relation of fiber diameter to other parameters including drawing speed, fiber aspect ratio, solution viscosity and solvent evaporation rate are studied at 0 and 25 °C. It is found that 0 °C is near the optimal temperature in terms of fiber diameter uniformity. Finally, this work also reports a self-expelling mechanism of the molten PEC at its thermolytic temperature from inside the Parylene-coated PEC fibers, which greatly reduces the sacrificial time to only tens of minutes.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1245-1248
A new method to manufacture parylene microcapillaries
A new way to fabricate extremely long and uniform Parylene microcapillaries with a minimum inner diameter of 3 μm and a length exceeding 30 cm is reported here. The method starts with drawing sacrificial poly(ethylene carbonate) (PEC) fibers from its chloroform solution and then forms hollow capillaries by coating the fibers with Parylene and removing the sacrificial PEC at its thermolytic temperature. For the fiber drawing, the relation of fiber diameter to other parameters including drawing speed, fiber aspect ratio, solution viscosity and solvent evaporation rate are studied at 0 and 25 °C. It is found that 0 °C is near the optimal temperature in terms of fiber diameter uniformity. Finally, this work also reports a self-expelling mechanism of the molten PEC at its thermolytic temperature from inside the Parylene-coated PEC fibers, which greatly reduces the sacrificial time to only tens of minutes.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1547-1550
A vacuum capillary viscometer that measures the viscosity of biofluids
This paper reports a novel vacuum capillary viscometer featuring small sample volume (1 to 4 μL) and fast turnaround time (less than 30seconds), which allows for the first time, repeatable blood and plasma viscosity measurements from adult zebrafish.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1547-1550
A vacuum capillary viscometer that measures the viscosity of biofluids
This paper reports a novel vacuum capillary viscometer featuring small sample volume (1 to 4 μL) and fast turnaround time (less than 30seconds), which allows for the first time, repeatable blood and plasma viscosity measurements from adult zebrafish.
- Open Access
- 16 May 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1980
A Rapid Capillary-Pressure Driven Micro-Channel to Demonstrate Newtonian Fluid Behavior of Zebrafish Blood at High Shear Rates
Blood viscosity provides the rheological basis to elucidate shear stress underlying developmental cardiac mechanics and physiology. Zebrafish is a high throughput model for developmental biology, forward-genetics, and drug discovery. The micro-scale posed an experimental challenge to measure blood viscosity. To address this challenge, a microfluidic viscometer driven by surface tension was developed to reduce the sample volume required (3μL) for rapid (500 s−1), at which the power law exponent (n) of zebrafish blood was nearly 1 behaving as a Newtonian fluid. The measured values of whole blood from the micro-channel (4.17cP) and the vacuum method (4.22cP) at 500 s−1were closely correlated at 27 °C. A calibration curve was established for viscosity as a function of hematocrits to predict a rise and fall in viscosity during embryonic development. Thus, our rapid capillary pressure-driven micro-channel revealed the Newtonian fluid behavior of zebrafish blood at high shear rates and the dynamic viscosity during development.
- 16 May 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1980
Open AccessA Rapid Capillary-Pressure Driven Micro-Channel to Demonstrate Newtonian Fluid Behavior of Zebrafish Blood at High Shear Rates
Blood viscosity provides the rheological basis to elucidate shear stress underlying developmental cardiac mechanics and physiology. Zebrafish is a high throughput model for developmental biology, forward-genetics, and drug discovery. The micro-scale posed an experimental challenge to measure blood viscosity. To address this challenge, a microfluidic viscometer driven by surface tension was developed to reduce the sample volume required (3μL) for rapid (500 s−1), at which the power law exponent (n) of zebrafish blood was nearly 1 behaving as a Newtonian fluid. The measured values of whole blood from the micro-channel (4.17cP) and the vacuum method (4.22cP) at 500 s−1were closely correlated at 27 °C. A calibration curve was established for viscosity as a function of hematocrits to predict a rise and fall in viscosity during embryonic development. Thus, our rapid capillary pressure-driven micro-channel revealed the Newtonian fluid behavior of zebrafish blood at high shear rates and the dynamic viscosity during development.
- 8 April 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (2) , 26
Parylene scaffold for cartilage lesion
Evaluate parylene scaffold feasibility in cartilage lesion treatment, introducing a novel paradigm combining a reparative and superficial reconstructive procedure. Fifteen rabbits were used. All animals had both knees operated and the same osteochondral lesion model was created bilaterally. The parylene scaffold was implanted in the right knee, and the left knee of the same animal was used as control. The animals were euthanized at different time points after surgery: four animals at three weeks, three animals at six weeks, four animals at nine weeks, and four animals at 12 weeks. Specimens were analyzed by International Cartilage Repair Society (ICRS) macroscopic evaluation, modified Pineda histologic evaluation of cartilage repair, and collagen II immunostaining. Parylene knees were compared to its matched contra-lateral control knees of the same animal using the Wilcoxon matched-pairs signed rank. ICRS mean ± SD values for parylene versus control, three, six, nine and twelve weeks, respectively: 7.83 ± 1.85 versus 4.42 ± 1.08, p = 0.0005; 10.17 ± 1.17 versus 6.83 ± 1.17, p = 0.03; 10.89 ± 0.60 versus 7.33 ± 2.18, p = 0.007; 10.67 ± 0.78 versus 7.83 ± 3.40, p = 0.03. Modified Pineda mean ± SD values for parylene versus control, six, nine and twelve weeks, respectively: 3.37 ± 0.87 versus 6.94 ± 1.7, p < 0.0001; 5.73 ± 2.05 versus 6.41 ± 1.7, p = 0.007; 3.06 ± 1.61 versus 6.52 ± 1.51, p < 0.0001. No inflammation was seen. Parylene implanted knees demonstrated higher collagen II expression via immunostaining in comparison to the control knees. Parylene scaffolds are a feasible option for cartilage lesion treatment and the combination of a reparative to a superficial reconstructive procedure using parylene scaffolds led to better results than the reparative procedure alone.
- 8 April 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (2) , 26
Parylene scaffold for cartilage lesion
Evaluate parylene scaffold feasibility in cartilage lesion treatment, introducing a novel paradigm combining a reparative and superficial reconstructive procedure. Fifteen rabbits were used. All animals had both knees operated and the same osteochondral lesion model was created bilaterally. The parylene scaffold was implanted in the right knee, and the left knee of the same animal was used as control. The animals were euthanized at different time points after surgery: four animals at three weeks, three animals at six weeks, four animals at nine weeks, and four animals at 12 weeks. Specimens were analyzed by International Cartilage Repair Society (ICRS) macroscopic evaluation, modified Pineda histologic evaluation of cartilage repair, and collagen II immunostaining. Parylene knees were compared to its matched contra-lateral control knees of the same animal using the Wilcoxon matched-pairs signed rank. ICRS mean ± SD values for parylene versus control, three, six, nine and twelve weeks, respectively: 7.83 ± 1.85 versus 4.42 ± 1.08, p = 0.0005; 10.17 ± 1.17 versus 6.83 ± 1.17, p = 0.03; 10.89 ± 0.60 versus 7.33 ± 2.18, p = 0.007; 10.67 ± 0.78 versus 7.83 ± 3.40, p = 0.03. Modified Pineda mean ± SD values for parylene versus control, six, nine and twelve weeks, respectively: 3.37 ± 0.87 versus 6.94 ± 1.7, p < 0.0001; 5.73 ± 2.05 versus 6.41 ± 1.7, p = 0.007; 3.06 ± 1.61 versus 6.52 ± 1.51, p < 0.0001. No inflammation was seen. Parylene implanted knees demonstrated higher collagen II expression via immunostaining in comparison to the control knees. Parylene scaffolds are a feasible option for cartilage lesion treatment and the combination of a reparative to a superficial reconstructive procedure using parylene scaffolds led to better results than the reparative procedure alone.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 440-443
A miniaturized ultrasonic power delivery system
A pair of 4.4mm diameter lead zirconium titanate (PZT) discs were employed for ultrasonic power delivery across biological tissue. The overall system, including the biological tissue and matching layers, was analyzed and modeled as a two-port network with an associated scattering matrix. The matrix coefficients were obtained experimentally in order to determine the maximum available gain (MAG) and optimal operating frequency of the system. The results were validated against finite element analysis simulations, and together they suggest that the miniaturized ultrasonic power delivery system has higher power transfer efficiency than a comparably-sized inductively coupled design at coupling distances greater than 9.5-15.5mm depending on the medium.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 440-443
A miniaturized ultrasonic power delivery system
A pair of 4.4mm diameter lead zirconium titanate (PZT) discs were employed for ultrasonic power delivery across biological tissue. The overall system, including the biological tissue and matching layers, was analyzed and modeled as a two-port network with an associated scattering matrix. The matrix coefficients were obtained experimentally in order to determine the maximum available gain (MAG) and optimal operating frequency of the system. The results were validated against finite element analysis simulations, and together they suggest that the miniaturized ultrasonic power delivery system has higher power transfer efficiency than a comparably-sized inductively coupled design at coupling distances greater than 9.5-15.5mm depending on the medium.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (1094687X) , 4747-4750
Segmentation and artifact removal in microwave-induced thermoacoustic imaging
Microwave-induced thermoacoustic (TA) imaging combines the soft-tissue dielectric contrast of microwave excitation with the resolution of ultrasound for the goal of a safe, high resolution, and possibly portable imaging technique. However, the hybrid nature of this method introduces new image-reconstruction challenges in enabling sufficient accuracy and segmentation. In this paper, we propose a segmentation technique based on the polarity characteristic of TA signals. A wavelet analysis based method is proposed to identify reflection artifacts as well. The time-frequency feature of the signal is used to assist differentiating artifacts. Ex vivo verification with experimental data is also provided.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (1094687X) , 4747-4750
Segmentation and artifact removal in microwave-induced thermoacoustic imaging
Microwave-induced thermoacoustic (TA) imaging combines the soft-tissue dielectric contrast of microwave excitation with the resolution of ultrasound for the goal of a safe, high resolution, and possibly portable imaging technique. However, the hybrid nature of this method introduces new image-reconstruction challenges in enabling sufficient accuracy and segmentation. In this paper, we propose a segmentation technique based on the polarity characteristic of TA signals. A wavelet analysis based method is proposed to identify reflection artifacts as well. The time-frequency feature of the signal is used to assist differentiating artifacts. Ex vivo verification with experimental data is also provided.