Peter Wilhelm
Peter Wilhelm has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Kirschniak
Department of Surgery and Transplantation, Tübingen University Hospital, Tübingen, Germany
4 shared publications - Jens Rolinger
Department of General and Visceral Surgery Kliniken Maria Hilf GmbH Mönchengladbach Germany
3 shared publications Johanna Miller
Department of Surgery and Transplantation , Tübingen University Hospital , Tübingen , Germany
2 shared publicationsKai Jansen
Department of Visceral Surgery, Maria Hilf Hospital Mönchengladbach, 41063 Mönchengladbach, Germany
2 shared publications- Patrick Beyersdorffer
Faculty of Informatics Reutlingen University Reutlingen Germany
2 shared publications Steffen Axt
Department of Surgery and Transplantation, Tübingen University Hospital, 72076 Tübingen, Germany
2 shared publications
Latest Publications
- Open Access
- 28 March 2022
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 33 (1) , 33-39
Enhancing the radiological classification system from the distal femur to the proximal tibia
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- 28 March 2022
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 33 (1) , 33-39
Open AccessEnhancing the radiological classification system from the distal femur to the proximal tibia
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- Open Access
- 25 January 2022
- Published by EDP Sciences in 4open
- Vol. 5, 4
Quantification of electrosurgery-related critical events during laparoscopic cholecystectomy – a prospective experimental study among surgical novices
Uncontrolled movement of instruments in laparoscopic surgery can lead to inadvertent tissue damage, particularly when the dissecting or electrosurgical instrument is located outside the field of view of the laparoscopic camera. The incidence and relevance of such events are currently unknown. The present work aims to identify and quantify potentially dangerous situations using the example of laparoscopic cholecystectomy (LC). Twenty-four final year medical students were prompted to each perform four consecutive LC attempts on a well-established box trainer in a surgical training environment following a standardized protocol in a porcine model. The following situation was defined as a critical event (CE): the dissecting instrument was inadvertently located outside the laparoscopic camera’s field of view. Simultaneous activation of the electrosurgical unit was defined as a highly critical event (hCE). Primary endpoint was the incidence of CEs. While performing 96 LCs, 2895 CEs were observed. Of these, 1059 (36.6%) were hCEs. The median number of CEs per LC was 20.5 (range: 1–125; IQR: 33) and the median number of hCEs per LC was 8.0 (range: 0–54, IQR: 10). Mean total operation time was 34.7 min (range: 15.6–62.5 min, IQR: 14.3 min). Our study demonstrates the significance of CEs as a potential risk factor for collateral damage during LC. Further studies are needed to investigate the occurrence of CE in clinical practice, not just for laparoscopic cholecystectomy but also for other procedures. Systematic training of future surgeons as well as technical solutions address this safety issue.
- 25 January 2022
- Published by EDP Sciences in 4open
- Vol. 5, 4
Open AccessQuantification of electrosurgery-related critical events during laparoscopic cholecystectomy – a prospective experimental study among surgical novices
Uncontrolled movement of instruments in laparoscopic surgery can lead to inadvertent tissue damage, particularly when the dissecting or electrosurgical instrument is located outside the field of view of the laparoscopic camera. The incidence and relevance of such events are currently unknown. The present work aims to identify and quantify potentially dangerous situations using the example of laparoscopic cholecystectomy (LC). Twenty-four final year medical students were prompted to each perform four consecutive LC attempts on a well-established box trainer in a surgical training environment following a standardized protocol in a porcine model. The following situation was defined as a critical event (CE): the dissecting instrument was inadvertently located outside the laparoscopic camera’s field of view. Simultaneous activation of the electrosurgical unit was defined as a highly critical event (hCE). Primary endpoint was the incidence of CEs. While performing 96 LCs, 2895 CEs were observed. Of these, 1059 (36.6%) were hCEs. The median number of CEs per LC was 20.5 (range: 1–125; IQR: 33) and the median number of hCEs per LC was 8.0 (range: 0–54, IQR: 10). Mean total operation time was 34.7 min (range: 15.6–62.5 min, IQR: 14.3 min). Our study demonstrates the significance of CEs as a potential risk factor for collateral damage during LC. Further studies are needed to investigate the occurrence of CE in clinical practice, not just for laparoscopic cholecystectomy but also for other procedures. Systematic training of future surgeons as well as technical solutions address this safety issue.
- 1 March 2021
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 66 (4) , 413-421
Detection of adverse events leading to inadvertent injury during laparoscopic cholecystectomy using convolutional neural networks
Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train the CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labeled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.
- 1 March 2021
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 66 (4) , 413-421
Detection of adverse events leading to inadvertent injury during laparoscopic cholecystectomy using convolutional neural networks
Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train the CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labeled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.
- 1 November 2020
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 232, 151560
Endoscopic projection of the gastroduodenal artery: Anatomical implications for bleeding management
- 1 November 2020
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 232, 151560
Endoscopic projection of the gastroduodenal artery: Anatomical implications for bleeding management
- 28 November 2019
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 30 (3) , 477-482
TuThor: an innovative new training model for video-assisted thoracic surgery
OBJECTIVES: Video-assisted thoracic surgery (VATS) is a complex technique requiring dedicated surgical training. Platforms for such training are scarce and often rely on the use of live animals, which raises ethical concerns. The objective of this study was to develop a box trainer that is dedicated for VATS training and able to reproduce bleeding scenarios. METHODS: The developed Tuebingen Thorax Trainer comprises 5 components that are mounted on a human anatomy-like thoracic cavity containing a porcine organ complex. Any standard thoracoscopic instrument can be used. The organ complex is attached to a perfusion module. We assessed the applicability of the system in four 1-day VATS training courses at the Tuebingen Surgical Training Center. Assessment was performed using a questionnaire handed out to all participants. RESULTS: Forty participants have been trained with the Tuebingen Thorax Trainer at our institution since November 2016. Thirty-five (87.5%) participants stated that the Tuebingen Thorax Trainer is an adequate model for VATS training. The ex vivo organ complex was reported to be realistic with regards to the level of detail and scale (76%). A large proportion of participants (27.5%) were experienced with VATS and reported having performed >50 procedures before taking the training course. CONCLUSIONS: This new training device allows realistic training for VATS procedures. ‘Stagnant hydrostatic perfusion’ permits simulation of reproducible bleeding scenarios. The device is low in production costs and offers a strong resemblance to the clinical scenario. It reduces the use of animal models and contributes to the efforts in making surgical skills training for VATS more accessible.
- 28 November 2019
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 30 (3) , 477-482
TuThor: an innovative new training model for video-assisted thoracic surgery
OBJECTIVES: Video-assisted thoracic surgery (VATS) is a complex technique requiring dedicated surgical training. Platforms for such training are scarce and often rely on the use of live animals, which raises ethical concerns. The objective of this study was to develop a box trainer that is dedicated for VATS training and able to reproduce bleeding scenarios. METHODS: The developed Tuebingen Thorax Trainer comprises 5 components that are mounted on a human anatomy-like thoracic cavity containing a porcine organ complex. Any standard thoracoscopic instrument can be used. The organ complex is attached to a perfusion module. We assessed the applicability of the system in four 1-day VATS training courses at the Tuebingen Surgical Training Center. Assessment was performed using a questionnaire handed out to all participants. RESULTS: Forty participants have been trained with the Tuebingen Thorax Trainer at our institution since November 2016. Thirty-five (87.5%) participants stated that the Tuebingen Thorax Trainer is an adequate model for VATS training. The ex vivo organ complex was reported to be realistic with regards to the level of detail and scale (76%). A large proportion of participants (27.5%) were experienced with VATS and reported having performed >50 procedures before taking the training course. CONCLUSIONS: This new training device allows realistic training for VATS procedures. ‘Stagnant hydrostatic perfusion’ permits simulation of reproducible bleeding scenarios. The device is low in production costs and offers a strong resemblance to the clinical scenario. It reduces the use of animal models and contributes to the efforts in making surgical skills training for VATS more accessible.
- Open Access
- 25 September 2019
- Published by Walter de Gruyter GmbH in Innovative Surgical Sciences
- Vol. 4 (3) , 116-120
Novel box trainer for taTME – prospective evaluation among medical students
Background: Transanal total mesorectal excision (taTME) has been subject to extensive research and increasing clinical application. It allows further reduction of trauma by accessing via a natural orifice. Manifold platforms and instruments have been introduced and heterogeneity in surgical techniques exists. Because of the technique’s complexity there is a persistent need for dedicated training devices and concepts.Materials and methods: The key steps of taTME were analyzed and a box trainer with three modules resembling these steps was designed and manufactured. Twenty-one surgically inexperienced medical students performed five repetitions of the three tasks with the new box trainer. Time and error count were analyzed for assessment of a learning curve.Results: A significant reduction of processing time could be demonstrated for tasks 1–3 (p < 0.001; p < 0.001; p = 0.001). The effect size was high for comparison of repetition 1 and 5 and decreased over the course (task 1: r = 0.88 vs. r = 0.21; task 2: r = 0.86 vs. r = 0.23; task 3: r = 0.74 vs. r = 0.44). Also, a significant reduction of errors was demonstrated for tasks 1 and 2. The decrease of effect size was analogously demonstrated.Conclusions: The trainer might help to reduce the use of animal models for testing of platforms and instruments as well as gaining first-hand experience in transanal rectal resection.
- 25 September 2019
- Published by Walter de Gruyter GmbH in Innovative Surgical Sciences
- Vol. 4 (3) , 116-120
Open AccessNovel box trainer for taTME – prospective evaluation among medical students
Background: Transanal total mesorectal excision (taTME) has been subject to extensive research and increasing clinical application. It allows further reduction of trauma by accessing via a natural orifice. Manifold platforms and instruments have been introduced and heterogeneity in surgical techniques exists. Because of the technique’s complexity there is a persistent need for dedicated training devices and concepts.Materials and methods: The key steps of taTME were analyzed and a box trainer with three modules resembling these steps was designed and manufactured. Twenty-one surgically inexperienced medical students performed five repetitions of the three tasks with the new box trainer. Time and error count were analyzed for assessment of a learning curve.Results: A significant reduction of processing time could be demonstrated for tasks 1–3 (p < 0.001; p < 0.001; p = 0.001). The effect size was high for comparison of repetition 1 and 5 and decreased over the course (task 1: r = 0.88 vs. r = 0.21; task 2: r = 0.86 vs. r = 0.23; task 3: r = 0.74 vs. r = 0.44). Also, a significant reduction of errors was demonstrated for tasks 1 and 2. The decrease of effect size was analogously demonstrated.Conclusions: The trainer might help to reduce the use of animal models for testing of platforms and instruments as well as gaining first-hand experience in transanal rectal resection.