AKAndreas Kirschniak

Andreas Kirschniak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreas Kirschniak has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A flexible implant for acute intrapancreatic electrophysiology

    by Domenic Pascual, Lisa Brauns, Ruth Domes, Matthias Tisler, Marco Kögel, Angelika Stumpf, Andreas Kirschniak, Jens Rolinger, Udo Kraushaar, Peter D. Jones

    Microelectrode arrays (MEAs) have proven to be a powerful tool to study electrophysiological processes over the last decades with most technology developed for investigation of the heart or brain. Other targets in the field of bioelectronic medicine are the peripheral nervous system and its innervation of various organs. Beyond the heart and nervous systems, the beta cells of the pancreatic islets of Langerhans generate action potentials during the production of insulin. In vitro experiments have demonstrated that their activity is a biomarker for blood glucose levels, suggesting that recording their activity in vivo could support patients suffering from diabetes mellitus with long-term automated read-out of blood glucose concentrations. Here, we present a flexible polymer-based implant having 64 low impedance microelectrodes designed to be implanted to a depth of 10 mm into the pancreas. As a first step, the implant will be used in acute experiments in pigs to explore the electrophysiological processes of the pancreas in vivo. Beyond use in the pancreas, our flexible implant and simple implantation method may also be used in other organs such as the brain.


  • Open Access

    Quantification of electrosurgery-related critical events during laparoscopic cholecystectomy – a prospective experimental study among surgical novices

    by Jens Rolinger, Nils Model, Kai Jansen, Madeleine Knöll, Patrick Beyersdorffer, Wolfgang Kunert, Steffen Axt, Andreas Kirschniak, Peter Wilhelm

    Uncontrolled movement of instruments in laparoscopic surgery can lead to inadvertent tissue damage, particularly when the dissecting or electrosurgical instrument is located outside the field of view of the laparoscopic camera. The incidence and relevance of such events are currently unknown. The present work aims to identify and quantify potentially dangerous situations using the example of laparoscopic cholecystectomy (LC). Twenty-four final year medical students were prompted to each perform four consecutive LC attempts on a well-established box trainer in a surgical training environment following a standardized protocol in a porcine model. The following situation was defined as a critical event (CE): the dissecting instrument was inadvertently located outside the laparoscopic camera’s field of view. Simultaneous activation of the electrosurgical unit was defined as a highly critical event (hCE). Primary endpoint was the incidence of CEs. While performing 96 LCs, 2895 CEs were observed. Of these, 1059 (36.6%) were hCEs. The median number of CEs per LC was 20.5 (range: 1–125; IQR: 33) and the median number of hCEs per LC was 8.0 (range: 0–54, IQR: 10). Mean total operation time was 34.7 min (range: 15.6–62.5 min, IQR: 14.3 min). Our study demonstrates the significance of CEs as a potential risk factor for collateral damage during LC. Further studies are needed to investigate the occurrence of CE in clinical practice, not just for laparoscopic cholecystectomy but also for other procedures. Systematic training of future surgeons as well as technical solutions address this safety issue.


  • Laparoskopische Heller-Myotomie zur Therapie der Achalasie

    by Jens Rolinger, Johanna Miller, Rupert Bolzenius, Frank Granderath, Andreas Kirschniak, Peter Wilhelm

    Zusammenfassung: Zielsetzung In der Literatur bezeichnet die Achalasie eine primär ösophageale Motilitätsstörung, die durch das Fehlen von Peristaltik und durch inkomplette oder vollständig fehlende Relaxation des unteren Ösophagussphinkters charakterisiert ist. Leitsymptom ist die Dysphagie. Das Therapieziel besteht in der chirurgischen oder interventionellen Behebung der ösophagealen Ausflussbahn auf Höhe der ösophagogastralen Übergangszone. Indikation Wir präsentieren den Fall eines 24-jährigen Patienten, der sich mit einer seit 2 Jahren bestehenden Dysphagie, begleitet von Regurgitationen, Odynophagie sowie einem unbeabsichtigten Gewichtsverlust, vorstellt. Methoden Das Video erläutert die präoperativen bildgebenden sowie endoskopischen Befunde und zeigt die Technik der laparoskopischen Heller-Myotomie mit partieller Fundoplicatio nach Dor. Schlussfolgerung Hinsichtlich der Therapie der klassischen Achalasie kann die laparoskopische Heller-Myotomie mit partieller Fundoplicatio nach Dor – trotz Kontroversen hinsichtlich der peroralen endoskopischen Myotomie als alternative Therapieoption – als etabliertes Standardverfahren angesehen werden.

  • Reducing Degrees of Freedom in Surgical Suturing: Implications for Minimally Invasive Device Development—A Prospective Experimental Study

    by Peter Wilhelm, Lisa Lambidis, Jacob Msc Williams, Steffen Axt, Pirmin Storz, Wolfgang Msc Kunert, Andreas Md Kirschniak, Jens Rolinger

    Open surgery allows the use of all 6 degrees of freedom (DOF; x-y-z and roll-pitch-yaw), whereas laparoscopy requires working under limitation to 4 axes. We present a prospective experimental study evaluating translational and rotational DOF restriction in surgical suturing tasks. An experimental platform included a kinematic structure that limited the maneuverability of the surgical instruments. The subjects (n=20) worked in a randomized order using (1) 6DOF, (2) 4DOF with 3 translational and 1 rotational DOF (4TRANS), and (3) 4DOF with 1 translational and 3 rotational DOF (4ROT). The time required to perform each task was recorded. Suturing and knot tying were significantly faster under 6DOF compared with 4ROT (both PP<0.001). Assessment of subjective difficulty and impairment showed most favorable results for 6DOF. The advantage of rotational compared with translational DOF should be considered in the development of future surgical devices.


  • Detection of adverse events leading to inadvertent injury during laparoscopic cholecystectomy using convolutional neural networks

    by Patrick Beyersdorffer, Wolfgang Kunert, Kai Jansen, Johanna Miller, Peter Wilhelm, Oliver Burgert, Andreas Kirschniak, Jens Rolinger

    Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train the CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labeled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.


  • Open Access

    Impact of haptic feedback on applied intracorporeal forces using a novel surgical robotic system—a randomized cross-over study with novices in an experimental setup

    by Johanna Miller, Manuel Braun, Johannes Bilz, Sebastian Matich, Carsten Neupert, Wolfgang Kunert, Andreas Kirschniak

    Background: Most currently used surgical robots have no force feedback; the next generation displays forces visually. A novel single-port robotic surgical system called FLEXMIN has been developed. Through an outer diameter of 38 mm, two instruments are teleoperated from a surgeon’s control console including true haptic force feedback. One additional channel incorporates a telescope, another is free for special instrument functions.Methods: This randomized cross-over study analyzed the effect of haptic feedback on the application of intracorporeal forces. In a standardized experiment setup, the subjects had to draw circles with the surgical robot as gently as possible. The applied forces, the required time spans, and predefined error rates were measured.Results: Without haptic feedback, the maximum forces (median/IQR) were 6.43 N/2.96 N. With haptic feedback, the maximum forces were lower (3.57 N/1.94 N,p < 0.001). Also, the arithmetic means of the force progression (p < 0.001) and their standard deviations (p < 0.001) were lower. Not significant were the shorter durations and lower error rates. No sequence effect of force or duration was detected. No characteristic learning or fatigue curve was observed.Conclusions: In the experiment setup, the true haptic force feedback can reduce the applied intracorporeal robotic force to one-half when considering the aspects maximum, means, and standard deviation. Other test tasks are needed to validate the influence of force feedback on surgical efficiency and safety.


  • Open Access

    Learning curves, potential and speed in training of laparoscopic skills: a randomised comparative study in a box trainer

    by Wolfgang Kunert, Pirmin Storz, Nicolaus Dietz, Steffen Axt, Claudius Falch, Andreas Kirschniak, Peter Wilhelm

    Background: The effectiveness of practical surgical training is characterised by an inherent learning curve. Decisive are individual initial starting capabilities, learning speed, ideal learning plateaus, and resulting learning potentials. The quantification of learning curves requires reproducible tasks with varied levels of difficulty. The hypothesis of this study is that the use of three-dimensional (3D) vision is more advantageous than two-dimensional vision (2D) for the learning curve in laparoscopic training. Methods: Forty laparoscopy novices were recruited and randomised to a 2D Group and a 3D Group. A laparoscopy box trainer with two standardised tasks was used for training of surgical tasks. Task 1 was a positioning task, while Task 2 called for laparoscopic knotting as a more complex process. Each task was repeated at least ten times. Performance time and the number of predefined errors were recorded. 2D performance after 3D training was assessed in an additional final 2D cycle undertaken by the 3D Group. Results: The calculated learning plateaus of both performance times and errors were lower for 3D. Independent of the vision mode the learning curves were smoother (exponential decay) and efficiency was learned faster than precision. The learning potentials varied widely depending on the corresponding initial values and learning plateaus. The final 2D performance time of the 3D-trained group was not significantly better than that of the 2D Group. The final 2D error numbers were similar for all groups. Conclusions: Stereoscopic vision can speed up laparoscopic training. The 3D learning curves resulted in better precision and efficiency. The 3D-trained group did not show inferior performance in the final 2D cycle. Consequently, we encourage the training of surgical competences like suturing and knotting under 3D vision, even if it is not available in clinical routine.


  • TuThor: an innovative new training model for video-assisted thoracic surgery

    by Lorenz Domhan, Jonas Johannink, Johanna Miller, Volker Steger, Albert Linder, Andreas Kirschniak, Peter Wilhelm

    OBJECTIVES: Video-assisted thoracic surgery (VATS) is a complex technique requiring dedicated surgical training. Platforms for such training are scarce and often rely on the use of live animals, which raises ethical concerns. The objective of this study was to develop a box trainer that is dedicated for VATS training and able to reproduce bleeding scenarios. METHODS: The developed Tuebingen Thorax Trainer comprises 5 components that are mounted on a human anatomy-like thoracic cavity containing a porcine organ complex. Any standard thoracoscopic instrument can be used. The organ complex is attached to a perfusion module. We assessed the applicability of the system in four 1-day VATS training courses at the Tuebingen Surgical Training Center. Assessment was performed using a questionnaire handed out to all participants. RESULTS: Forty participants have been trained with the Tuebingen Thorax Trainer at our institution since November 2016. Thirty-five (87.5%) participants stated that the Tuebingen Thorax Trainer is an adequate model for VATS training. The ex vivo organ complex was reported to be realistic with regards to the level of detail and scale (76%). A large proportion of participants (27.5%) were experienced with VATS and reported having performed >50 procedures before taking the training course. CONCLUSIONS: This new training device allows realistic training for VATS procedures. ‘Stagnant hydrostatic perfusion’ permits simulation of reproducible bleeding scenarios. The device is low in production costs and offers a strong resemblance to the clinical scenario. It reduces the use of animal models and contributes to the efforts in making surgical skills training for VATS more accessible.


  • How Much Stereoscopic Effect Does Laparoscopy Need? Controlled, Prospective Randomized Trial on Surgical Task Efficiency in Standardized Phantom Tasks

    by Wolfgang Kunert, Thomas Auer, Pirmin Storz, Manuel Braun, Andreas Kirschniak, Claudius Falch

    Background. To regain 2-eyed vision in laparoscopy, dual-channeled optics have been introduced. With this optics design, the distance between the 2 front lenses defines how much stereoscopic effect is seen. This study quantifies the impact of an enhanced and a reduced stereo effect on surgical task efficiency. Methods. A prospective single-blinded study was performed with 20 laparoscopic novices in an inanimate experimental setting. A standard bichannelled stereo system was used to perform a suturing and knotting task. The working distance and the task size were scaled to vary the stereo effect and, thereby, simulate hypothetic stereo optics with enhanced and reduced optical bases. The task performances were timed, and the number of trials for stitching out was counted. The participants finally filled out a questionnaire to collect subjective impressions. Results. The increase of the stereo effect by 50% caused no objective improvement in laparoscopic knotting compared with typical 3D (control group with stereo basis of 4.5 mm). But ergonomic disadvantages (headache) were subjectively reported in 1 of 20 cases in the questionnaire. The reduction of the stereo effect by one-third led to a significantly longer average execution time. There was no significant dependence found between stereo effect and number of stich-out trials, stitching precision, or knotting quality. Conclusions. Considering laparoscopy, it does not seem advisable to enhance the stereo effect because of ergonomic problems. Otherwise, a miniaturization of the 3D scope (5 mm version) is problematic because its benefit mostly shrinks with the reduced stereo effect.