Xiangju Mao
Research Subjects
Xiangju Mao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Wenshan Ni
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, PR China
4 shared publicationsTiantian Wang
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, PR China
3 shared publications- Xiaorui Guo
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, PR China
3 shared publications Fang Xiao
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou, 450006, PR China; China National Engineering Research Center for Utilization of Industrial Minerals, Zhengzhou, 450006, PR China; Key Laboratory for Polymetallic Ores Evaluation and Utilization, MNR, Zhengzhou, 450006, PR China
2 shared publicationsHongli Zhang
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou, 450006, PR China; China National Engineering Research Center for Utilization of Industrial Minerals, Zhengzhou, 450006, PR China; Key Laboratory for Polymetallic Ores Evaluation and Utilization, MNR, Zhengzhou, 450006, PR China
2 shared publications- Hongli Zhang
Key Laboratory of Evaluation and Multipurpose Utilization of Polymetallic Ores Ministry of Natural Resources, Zhengzhou 450006, China
2 shared publications
Latest Publications
- 19 November 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (44) , 10891-10902
Combined LA-ICP-MS with empirical coefficient correction and Bi fire assay for the determination of ultra-trace Pt, Pd, and Au in geochemical samples using a 194 Pt isotope spike as the internal standard
In this work, a novel and environmentally friendly method based on Bi-FA combined with LA-ICP-MS was established for the determination of ultra-trace Pt, Pd, and Au in geochemical samples, using a 194 Pt isotope spike as the internal standard.
- 19 November 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (44) , 10891-10902
Combined LA-ICP-MS with empirical coefficient correction and Bi fire assay for the determination of ultra-trace Pt, Pd, and Au in geochemical samples using a 194 Pt isotope spike as the internal standard
In this work, a novel and environmentally friendly method based on Bi-FA combined with LA-ICP-MS was established for the determination of ultra-trace Pt, Pd, and Au in geochemical samples, using a 194 Pt isotope spike as the internal standard.
- 26 October 2026
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
Empirical coefficient LA-ICP-MS and XRF for the determination of trace Zr, Hf, Nb, and Ta in geochemical samples
Zr, Hf, Nb, and Ta are strategic mineral elements, and their accurate determination is essential for resource exploration and geoscientific research. Due to their refractory and easily hydrolyzed nature, traditional analytical methods face challenges, such as cumbersome procedures and low efficiency. This study proposes a novel analytical technique that combines XRF and LA-ICP-MS to accurately determine Zr, Hf, Nb, and Ta in geochemical samples using a solid-solid analysis strategy. Li 2 B 4 O 7 -LiBO 2 (67:33) reagents were used to fuse geochemical reference materials and actual samples into homogeneous glass sheets at 1100 °C. The empirical coefficient method-XRF was applied to determine Zr content in the glass sheets of actual samples, providing an internal standard reference for subsequent LA-ICP-MS analysis. Given the similar chemical properties, 90 Zr was used as the internal standard for 178 Hf, 93 Nb, and 181 Ta. After measuring the mass spectral intensities by LA-ICP-MS, the calibration curves of Hf, Nb, and Ta were fitted by the empirical coefficient method, and the correlation coefficients were obtained as 0.9962 ∼ 0.9977, enabling accurate determination of these elements in actual geochemical samples. The analytical results for other geochemical reference materials showed excellent agreement with reference values, confirming the reliability of the method. The combined XRF and LA-ICP-MS approach established in this study provides an efficient, accurate, and environmentally friendly analytical pathway for determining Zr, Hf, Nb, and Ta in geochemical samples, making it particularly suitable for large-scale geochemical surveys and strategic mineral resources.
- 26 October 2026
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
Empirical coefficient LA-ICP-MS and XRF for the determination of trace Zr, Hf, Nb, and Ta in geochemical samples
Zr, Hf, Nb, and Ta are strategic mineral elements, and their accurate determination is essential for resource exploration and geoscientific research. Due to their refractory and easily hydrolyzed nature, traditional analytical methods face challenges, such as cumbersome procedures and low efficiency. This study proposes a novel analytical technique that combines XRF and LA-ICP-MS to accurately determine Zr, Hf, Nb, and Ta in geochemical samples using a solid-solid analysis strategy. Li 2 B 4 O 7 -LiBO 2 (67:33) reagents were used to fuse geochemical reference materials and actual samples into homogeneous glass sheets at 1100 °C. The empirical coefficient method-XRF was applied to determine Zr content in the glass sheets of actual samples, providing an internal standard reference for subsequent LA-ICP-MS analysis. Given the similar chemical properties, 90 Zr was used as the internal standard for 178 Hf, 93 Nb, and 181 Ta. After measuring the mass spectral intensities by LA-ICP-MS, the calibration curves of Hf, Nb, and Ta were fitted by the empirical coefficient method, and the correlation coefficients were obtained as 0.9962 ∼ 0.9977, enabling accurate determination of these elements in actual geochemical samples. The analytical results for other geochemical reference materials showed excellent agreement with reference values, confirming the reliability of the method. The combined XRF and LA-ICP-MS approach established in this study provides an efficient, accurate, and environmentally friendly analytical pathway for determining Zr, Hf, Nb, and Ta in geochemical samples, making it particularly suitable for large-scale geochemical surveys and strategic mineral resources.
- Open Access
- 5 May 2021
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2021, 1-8
Bismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
In this work, a novel method of bismuth fire assay (Bi-FA) combined with inductively coupled plasma mass spectrometry (ICP-MS) simultaneous determination of ultratrace gold (Au), platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), and iridium (Ir) in geologic samples was established. Bismuth oxide (Bi2O3) was used as noble metal elements fire assay collector, and Bi-remaining protection cupellation was employed to generate Bi granule. After the Bi granule was microwave-digested by aqua regia (40, v/v), 197Au, 195Pt, 106Pd, 101Ru, 103Rh, and 193Ir in the sample solution were determined by ICP-MS. Using Bi as cupellation protector, volatile Ru could be collected effectively and without volatilization loss during microwave digestion and decompression. Moreover, the toxicity of Bi was exceptionally low compared to toxic nickel oxide and lead oxide in nickel sulfide/lead fire assay; thus Bi-FA was a green environmental analysis method. The mineral composition and decomposition character of chromite, black shale, and polymetallic ore were investigated, and pretreatment procedures were optimized for such special samples. Besides, the influence of mass spectrum interference of coexisting elements was discussed. Under the optimal conditions, excellent curve fittings of Au, Pt, Pd, Ru, Rh, and Ir were obtained between 0.01 and 100ng·mL−1, with the correlation coefficients exceeding 0.9995. The detection limits were from 0.002ng·g−1 to 0.025ng·g−1. The developed method was applied to analyze the Chinese Certified Reference Materials (CRMs) and the determined values were in good agreement with the certified values.
- 5 May 2021
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2021, 1-8
Open AccessBismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
In this work, a novel method of bismuth fire assay (Bi-FA) combined with inductively coupled plasma mass spectrometry (ICP-MS) simultaneous determination of ultratrace gold (Au), platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), and iridium (Ir) in geologic samples was established. Bismuth oxide (Bi2O3) was used as noble metal elements fire assay collector, and Bi-remaining protection cupellation was employed to generate Bi granule. After the Bi granule was microwave-digested by aqua regia (40, v/v), 197Au, 195Pt, 106Pd, 101Ru, 103Rh, and 193Ir in the sample solution were determined by ICP-MS. Using Bi as cupellation protector, volatile Ru could be collected effectively and without volatilization loss during microwave digestion and decompression. Moreover, the toxicity of Bi was exceptionally low compared to toxic nickel oxide and lead oxide in nickel sulfide/lead fire assay; thus Bi-FA was a green environmental analysis method. The mineral composition and decomposition character of chromite, black shale, and polymetallic ore were investigated, and pretreatment procedures were optimized for such special samples. Besides, the influence of mass spectrum interference of coexisting elements was discussed. Under the optimal conditions, excellent curve fittings of Au, Pt, Pd, Ru, Rh, and Ir were obtained between 0.01 and 100ng·mL−1, with the correlation coefficients exceeding 0.9995. The detection limits were from 0.002ng·g−1 to 0.025ng·g−1. The developed method was applied to analyze the Chinese Certified Reference Materials (CRMs) and the determined values were in good agreement with the certified values.
- Open Access
- 24 March 2021
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 17 (4) , 552-563
Simultaneous Determination of Ultra-trace Pt, Pd, Rh and Ir in Geochemical Samples by Inductively Coupled Plasma Mass Spectrometry Following Tin Fire Assay Preconcentration and Microwave Digestion
Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as a fire assay collector to reduce the melting temperature from 1250°C to 1050°C, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution was determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale was investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1, with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g-1 to 0.057 ng g-1. Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.
- 24 March 2021
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 17 (4) , 552-563
Open AccessSimultaneous Determination of Ultra-trace Pt, Pd, Rh and Ir in Geochemical Samples by Inductively Coupled Plasma Mass Spectrometry Following Tin Fire Assay Preconcentration and Microwave Digestion
Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as a fire assay collector to reduce the melting temperature from 1250°C to 1050°C, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution was determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale was investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1, with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g-1 to 0.057 ng g-1. Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.
- 3 July 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (30) , 12013-12019
An innovative reversed-phase monolithic column modified with 4-vinylbiphenyl and ionic liquid stationary phases for capillary electrochromatography
A novel monolithic column was developed with 4-vinylbiphenyl and an ionic liquid as the functional monomers and ethylene dimethacrylate as the cross-linker by thermal copolymerization for reversed-phase capillary electrochromatography. For this monolithic column, an imidazole ionic liquid, 1-allyl-3-methylimidazolium chloride, was introduced as the generator of electroosmotic flow. The composition of the polymerization mixture for the preparation of the monolithic column was optimized in detail. Characterization using scanning electron microscopy and Fourier transform infrared spectroscopy indicated that the monolithic column is synthesized successfully with excellent porous structure. Successful baseline separation of aromatic compounds, phenols and anilines with high resolution and high column efficiency demonstrates that the obtained monolithic column has powerful reversed-phase chromatography performance. The relative standard deviation of the retention time for run-to-run (n = 5), day-to-day (n = 5) and column-to-column (n = 3) is in the range of 0.39–1.30%, 0.68–3.92% and 1.06–3.66%, respectively, which shows the monolithic column possesses good reproducibility. This novel monolithic column has been successfully applied for the separation of phenols in spiked lake water samples.
- 3 July 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (30) , 12013-12019
An innovative reversed-phase monolithic column modified with 4-vinylbiphenyl and ionic liquid stationary phases for capillary electrochromatography
A novel monolithic column was developed with 4-vinylbiphenyl and an ionic liquid as the functional monomers and ethylene dimethacrylate as the cross-linker by thermal copolymerization for reversed-phase capillary electrochromatography. For this monolithic column, an imidazole ionic liquid, 1-allyl-3-methylimidazolium chloride, was introduced as the generator of electroosmotic flow. The composition of the polymerization mixture for the preparation of the monolithic column was optimized in detail. Characterization using scanning electron microscopy and Fourier transform infrared spectroscopy indicated that the monolithic column is synthesized successfully with excellent porous structure. Successful baseline separation of aromatic compounds, phenols and anilines with high resolution and high column efficiency demonstrates that the obtained monolithic column has powerful reversed-phase chromatography performance. The relative standard deviation of the retention time for run-to-run (n = 5), day-to-day (n = 5) and column-to-column (n = 3) is in the range of 0.39–1.30%, 0.68–3.92% and 1.06–3.66%, respectively, which shows the monolithic column possesses good reproducibility. This novel monolithic column has been successfully applied for the separation of phenols in spiked lake water samples.
- 24 April 2019
- Published by Taylor & Francis in Analytical Letters
- Vol. 52 (11) , 1699-1710
Determination of Ultra-Trace Platinum, Palladium, Ruthenium, Rhodium, and Iridium in Rocks and Minerals by Inductively Coupled–Plasma Mass Spectrometry Following Nickel Sulfide Fire Assay Preconcentration and Open Mixed Acid Digestion
Platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), iridium (Ir), and osmiun (Os) are platinum-group elements with similar physic-chemical properties, and have important applications in geochemistry and environmental chemistry. However, due to their low abundance and inhomogeneous distribution in natural ores as well as the nugget effect, the accurate determination of the platinum-group elements has been a challenge for geological analysis. In this work, self-prepared and purified sodium carbonate (NiCO3) instead of commercial nickel oxide (NiO) was used as the fire assay collector in order to greatly reduce the reagent blank and method detection limits. In addition, the fuming time of HClO4 was strictly controlled at 10 min and a high sensitive method was developed for the simultaneous determination of ultra-trace Pt, Pd, Ru, Rh, and Ir in minerals by inductively coupled plasma-mass spectrometry (ICP-MS) following preconcentration with the nickel sulfide fire assay. Under the optimized conditions, the linear ranges of Pt, Pd, Ru, Rh, and Ir were between 0 and 100 ng mL−1, with correlation coefficients exceeding 0.9997. The detection limits were 0.015, 0.056, 0.014, 0.004, 0.012 ng mL−1 (for 10 g sample) for Pt, Pd, Ru, Rh and Ir, respectively. The developed method was successfully applied to analyze Chinese Certified Reference Materials (CRMs) GBW07288, GBW07289, GBW07290, GBW07291, GBW07292, GBW07293, GBW07294, GBW07101, GBW07102 and GBW07201 and the determined values were in good agreement with the certified values. The relative standard deviations (n = 5) of Pt, Pd, Ru, Rh and Ir were between 3.42% and 6.87% for the determination of GBW07291.
- 24 April 2019
- Published by Taylor & Francis in Analytical Letters
- Vol. 52 (11) , 1699-1710
Determination of Ultra-Trace Platinum, Palladium, Ruthenium, Rhodium, and Iridium in Rocks and Minerals by Inductively Coupled–Plasma Mass Spectrometry Following Nickel Sulfide Fire Assay Preconcentration and Open Mixed Acid Digestion
Platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), iridium (Ir), and osmiun (Os) are platinum-group elements with similar physic-chemical properties, and have important applications in geochemistry and environmental chemistry. However, due to their low abundance and inhomogeneous distribution in natural ores as well as the nugget effect, the accurate determination of the platinum-group elements has been a challenge for geological analysis. In this work, self-prepared and purified sodium carbonate (NiCO3) instead of commercial nickel oxide (NiO) was used as the fire assay collector in order to greatly reduce the reagent blank and method detection limits. In addition, the fuming time of HClO4 was strictly controlled at 10 min and a high sensitive method was developed for the simultaneous determination of ultra-trace Pt, Pd, Ru, Rh, and Ir in minerals by inductively coupled plasma-mass spectrometry (ICP-MS) following preconcentration with the nickel sulfide fire assay. Under the optimized conditions, the linear ranges of Pt, Pd, Ru, Rh, and Ir were between 0 and 100 ng mL−1, with correlation coefficients exceeding 0.9997. The detection limits were 0.015, 0.056, 0.014, 0.004, 0.012 ng mL−1 (for 10 g sample) for Pt, Pd, Ru, Rh and Ir, respectively. The developed method was successfully applied to analyze Chinese Certified Reference Materials (CRMs) GBW07288, GBW07289, GBW07290, GBW07291, GBW07292, GBW07293, GBW07294, GBW07101, GBW07102 and GBW07201 and the determined values were in good agreement with the certified values. The relative standard deviations (n = 5) of Pt, Pd, Ru, Rh and Ir were between 3.42% and 6.87% for the determination of GBW07291.