Xiaorui Guo
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaorui Guo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Xiangju Mao
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, China
3 shared publications - Hongli Zhang
Key Laboratory of Evaluation and Multipurpose Utilization of Polymetallic Ores Ministry of Natural Resources, Zhengzhou 450006, China
2 shared publications - Lu Liu
Key Laboratory of Evaluation and Multipurpose Utilization of Polymetallic Ores Ministry of Natural Resources, Zhengzhou 450006, China
2 shared publications - Qiliang Sun
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, China
2 shared publications - Wenshan Ni
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, China
2 shared publications - Zhonghua Tang
College of Chemistry, Chemical Engineering and Resource Utilization, Northeast Forestry University, Harbin 150040, China; Key Laboratory of Plant Ecology, Ministry of Education, Northeast Forestry University, Harbin 150040, China
2 shared publications
Latest Publications
- 19 November 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (44) , 10891-10902
Combined LA-ICP-MS with empirical coefficient correction and Bi fire assay for the determination of ultra-trace Pt, Pd, and Au in geochemical samples using a 194 Pt isotope spike as the internal standard
In this work, a novel and environmentally friendly method based on Bi-FA combined with LA-ICP-MS was established for the determination of ultra-trace Pt, Pd, and Au in geochemical samples, using a 194 Pt isotope spike as the internal standard.
- 19 November 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (44) , 10891-10902
Combined LA-ICP-MS with empirical coefficient correction and Bi fire assay for the determination of ultra-trace Pt, Pd, and Au in geochemical samples using a 194 Pt isotope spike as the internal standard
In this work, a novel and environmentally friendly method based on Bi-FA combined with LA-ICP-MS was established for the determination of ultra-trace Pt, Pd, and Au in geochemical samples, using a 194 Pt isotope spike as the internal standard.
- 6 May 2024
- Published by Elsevier in Environmental Pollution
- Vol. 352, 124116
Effects of polyethylene and biodegradable microplastics on the physiology and metabolic profiles of dandelion
- 6 May 2024
- Published by Elsevier in Environmental Pollution
- Vol. 352, 124116
Effects of polyethylene and biodegradable microplastics on the physiology and metabolic profiles of dandelion
- Open Access
- 5 May 2021
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2021, 1-8
Bismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
In this work, a novel method of bismuth fire assay (Bi-FA) combined with inductively coupled plasma mass spectrometry (ICP-MS) simultaneous determination of ultratrace gold (Au), platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), and iridium (Ir) in geologic samples was established. Bismuth oxide (Bi2O3) was used as noble metal elements fire assay collector, and Bi-remaining protection cupellation was employed to generate Bi granule. After the Bi granule was microwave-digested by aqua regia (40, v/v), 197Au, 195Pt, 106Pd, 101Ru, 103Rh, and 193Ir in the sample solution were determined by ICP-MS. Using Bi as cupellation protector, volatile Ru could be collected effectively and without volatilization loss during microwave digestion and decompression. Moreover, the toxicity of Bi was exceptionally low compared to toxic nickel oxide and lead oxide in nickel sulfide/lead fire assay; thus Bi-FA was a green environmental analysis method. The mineral composition and decomposition character of chromite, black shale, and polymetallic ore were investigated, and pretreatment procedures were optimized for such special samples. Besides, the influence of mass spectrum interference of coexisting elements was discussed. Under the optimal conditions, excellent curve fittings of Au, Pt, Pd, Ru, Rh, and Ir were obtained between 0.01 and 100ng·mL−1, with the correlation coefficients exceeding 0.9995. The detection limits were from 0.002ng·g−1 to 0.025ng·g−1. The developed method was applied to analyze the Chinese Certified Reference Materials (CRMs) and the determined values were in good agreement with the certified values.
- 5 May 2021
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2021, 1-8
Open AccessBismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
In this work, a novel method of bismuth fire assay (Bi-FA) combined with inductively coupled plasma mass spectrometry (ICP-MS) simultaneous determination of ultratrace gold (Au), platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), and iridium (Ir) in geologic samples was established. Bismuth oxide (Bi2O3) was used as noble metal elements fire assay collector, and Bi-remaining protection cupellation was employed to generate Bi granule. After the Bi granule was microwave-digested by aqua regia (40, v/v), 197Au, 195Pt, 106Pd, 101Ru, 103Rh, and 193Ir in the sample solution were determined by ICP-MS. Using Bi as cupellation protector, volatile Ru could be collected effectively and without volatilization loss during microwave digestion and decompression. Moreover, the toxicity of Bi was exceptionally low compared to toxic nickel oxide and lead oxide in nickel sulfide/lead fire assay; thus Bi-FA was a green environmental analysis method. The mineral composition and decomposition character of chromite, black shale, and polymetallic ore were investigated, and pretreatment procedures were optimized for such special samples. Besides, the influence of mass spectrum interference of coexisting elements was discussed. Under the optimal conditions, excellent curve fittings of Au, Pt, Pd, Ru, Rh, and Ir were obtained between 0.01 and 100ng·mL−1, with the correlation coefficients exceeding 0.9995. The detection limits were from 0.002ng·g−1 to 0.025ng·g−1. The developed method was applied to analyze the Chinese Certified Reference Materials (CRMs) and the determined values were in good agreement with the certified values.
- Open Access
- 24 March 2021
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 17 (4) , 552-563
Simultaneous Determination of Ultra-trace Pt, Pd, Rh and Ir in Geochemical Samples by Inductively Coupled Plasma Mass Spectrometry Following Tin Fire Assay Preconcentration and Microwave Digestion
Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as a fire assay collector to reduce the melting temperature from 1250°C to 1050°C, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution was determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale was investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1, with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g-1 to 0.057 ng g-1. Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.
- 24 March 2021
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 17 (4) , 552-563
Open AccessSimultaneous Determination of Ultra-trace Pt, Pd, Rh and Ir in Geochemical Samples by Inductively Coupled Plasma Mass Spectrometry Following Tin Fire Assay Preconcentration and Microwave Digestion
Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as a fire assay collector to reduce the melting temperature from 1250°C to 1050°C, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution was determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale was investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1, with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g-1 to 0.057 ng g-1. Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.
- Open Access
- 2 January 2014
- Published by Taylor & Francis in Journal of Plant Interactions
- Vol. 9 (1) , 640-646
The impacts of increased nitrate supply onCatharanthus roseusgrowth and alkaloid accumulations under ultraviolet-B stress
It has been reported that nitrate availability was able to modify the detrimental effects induced by excess ultraviolet-B (UV-B) radiation on plants. In this study, the medical plant Catharanthus roseus was subjected to UV-B stress and altered levels of nitrate nutrition to investigate their influence in a sole or combined way on growth and alkaloid productions. Our results showed that the UV-B stress obviously inhibited growth and led to damages of oxidative stress and lipid peroxidation. The simultaneous supply of higher nitrate nutrition could largely alleviate the inhibitory effects and damage symptom under the UV-B stress in C. roseus. Meanwhile, the UV-B-absorbing compounds as well as three alkaloids, vinblastine, vindoline, and catharanthine, were observed to have a remarkable elevation. These compounds were considered to serve as protectants of UV-B radiation. It was concluded that an increased nitrogen (N) supply could not only alleviate the inhibitory effect of UV-B stress on plant growth, but also enhance the accumulation of pharmaceutically used alkaloid in these plants. We proposed that the enrichment of N nutrition might provide more N source for alkaloid synthesis induced by UV-B radiation, eventually resulting in an increase of alkaloids accumulation.
- 2 January 2014
- Published by Taylor & Francis in Journal of Plant Interactions
- Vol. 9 (1) , 640-646
Open AccessThe impacts of increased nitrate supply onCatharanthus roseusgrowth and alkaloid accumulations under ultraviolet-B stress
It has been reported that nitrate availability was able to modify the detrimental effects induced by excess ultraviolet-B (UV-B) radiation on plants. In this study, the medical plant Catharanthus roseus was subjected to UV-B stress and altered levels of nitrate nutrition to investigate their influence in a sole or combined way on growth and alkaloid productions. Our results showed that the UV-B stress obviously inhibited growth and led to damages of oxidative stress and lipid peroxidation. The simultaneous supply of higher nitrate nutrition could largely alleviate the inhibitory effects and damage symptom under the UV-B stress in C. roseus. Meanwhile, the UV-B-absorbing compounds as well as three alkaloids, vinblastine, vindoline, and catharanthine, were observed to have a remarkable elevation. These compounds were considered to serve as protectants of UV-B radiation. It was concluded that an increased nitrogen (N) supply could not only alleviate the inhibitory effect of UV-B stress on plant growth, but also enhance the accumulation of pharmaceutically used alkaloid in these plants. We proposed that the enrichment of N nutrition might provide more N source for alkaloid synthesis induced by UV-B radiation, eventually resulting in an increase of alkaloids accumulation.