Yong Ki Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yong Ki Cho has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Chanyong Seo
Department of Physics, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications - Donggeun Jung
Department of Physics, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications - Kyoung Il Moon
Customized Manufacturing R&D Department (Siheung Technology Support Center), Korea Institute of Industrial Technology, Siheung 15014, Republic of Korea
2 shared publications - Namwuk Baek
Department of Physics, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications Sang Gweon Kim
Customized Manufacturing R&D Department Korea Institute of Industrial Technology Research Institute of Intelligent Manufacturing & Materials Technology Siheung‐Si 15014 Republic of Korea
2 shared publications- Sang Gweon Kim
KITECH, Korea, Republic of
2 shared publications
Latest Publications
- Open Access
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Diffusion barrier performance of the tungsten intermediate layer between the chromium coating and the zirconium alloy on the accident-tolerant fuel (ATF) cladding in the eutectic temperatures
Accident-tolerant fuel (ATF) claddings are being developed by depositing corrosion-resistant chromium onto zirconium alloys to suppress the rapid oxidation of zirconium alloys in full-field power loss and coolant loss (LOCA) environments. Normally Cr-Zr systems, exposure to ultra-high temperatures above 1332 °C triggers a eutectic reaction, leading to the dissolution of chromium and the formation of intermetallic compounds, which causes degradation of the cladding tube. To suppress this, Cr-RM-Zr systems have been studied, in which a refractory metal is introduced between zirconium and chromium as a diffusion barrier. In this study, tungsten was formed as a diffusion barrier under a chromium layer on cladding tubes, and high-temperature steam oxidation tests were conducted at temperatures above the eutectic temperature, specifically at 1350 and 1400 °C. Cr-W-Zr systems with different tungsten and chromium layers were prepared by sequential deposition using cathodic arc ion plating (CAIP). Four different samples were prepared with tungsten layer thicknesses ranging from 0.5 to 2.5 μm to determine the diffusion barrier performance, and the functional chromium layer was 15 μm. The diffusion barrier performance of the Cr-W-Zr systems was investigated using FE-SEM, EDX mapping, and depth profiling after high-temperature steam oxidation tests. The results show that the diffusion barrier performance of tungsten as a diffusion barrier can sufficiently prevent the deterioration of ATF cladding at a thickness of 1.5 μm or more. The destruction behavior of the thin tungsten layer as a diffusion barrier and the degradation mechanism of the Cr-W-Zr system are discussed.
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDiffusion barrier performance of the tungsten intermediate layer between the chromium coating and the zirconium alloy on the accident-tolerant fuel (ATF) cladding in the eutectic temperatures
Accident-tolerant fuel (ATF) claddings are being developed by depositing corrosion-resistant chromium onto zirconium alloys to suppress the rapid oxidation of zirconium alloys in full-field power loss and coolant loss (LOCA) environments. Normally Cr-Zr systems, exposure to ultra-high temperatures above 1332 °C triggers a eutectic reaction, leading to the dissolution of chromium and the formation of intermetallic compounds, which causes degradation of the cladding tube. To suppress this, Cr-RM-Zr systems have been studied, in which a refractory metal is introduced between zirconium and chromium as a diffusion barrier. In this study, tungsten was formed as a diffusion barrier under a chromium layer on cladding tubes, and high-temperature steam oxidation tests were conducted at temperatures above the eutectic temperature, specifically at 1350 and 1400 °C. Cr-W-Zr systems with different tungsten and chromium layers were prepared by sequential deposition using cathodic arc ion plating (CAIP). Four different samples were prepared with tungsten layer thicknesses ranging from 0.5 to 2.5 μm to determine the diffusion barrier performance, and the functional chromium layer was 15 μm. The diffusion barrier performance of the Cr-W-Zr systems was investigated using FE-SEM, EDX mapping, and depth profiling after high-temperature steam oxidation tests. The results show that the diffusion barrier performance of tungsten as a diffusion barrier can sufficiently prevent the deterioration of ATF cladding at a thickness of 1.5 μm or more. The destruction behavior of the thin tungsten layer as a diffusion barrier and the degradation mechanism of the Cr-W-Zr system are discussed.
- 1 March 2026
- Published by American Vacuum Society in Biointerphases
- Vol. 21 (2)
Improving resistance to biliary stent occlusion by surface hydrophilization and amidation through plasma treatment to the inner surface of polyethylene tubes
Biliary stents are medical devices inserted into the bile duct to treat biliary strictures. However, inserted stents can become occluded within a few months after placement. In this study, the inner surface of a polyethylene (PE) tube was plasma-treated with helium (He), nitrogen (N2), oxygen (O2), and their gas mixtures to improve resistance to stent occlusion. Surface characteristics were analyzed by water contact angle (WCA) and x-ray photoelectron spectroscopy (XPS) measurements. In the WCA results, bare PE without plasma treatment was the most hydrophobic at 100.7°, whereas PE(He) plasma-treated with He gas became the most hydrophilic at 26.1°. XPS deconvolution analysis revealed that the PE(He) and PE(He/N2) contained a considerable proportion of O 1s present as amide (–CONH–) groups exceeding 40%, whereas the other samples had proportions below 7%. The resistance to stent occlusion was verified through microbial and cancer cell adhesion assays. In the microbial adhesion assay, Escherichia coli (E. coli) was used, and PE(He) showed a statistically significant reduction in E. coli growth compared to bare PE. Inhibition of cancer cell adhesion was the most pronounced in PE(He) and PE(He/N2), with reductions in fluorescence intensities of 75.5% and 81.5%, respectively. Overall, both surface hydrophilization and amidation were found to be effective in inhibiting the adhesion of organic contaminants. It was proposed that plasma surface treatment has the potential to improve resistance to biliary stent occlusion.
- 1 March 2026
- Published by American Vacuum Society in Biointerphases
- Vol. 21 (2)
Improving resistance to biliary stent occlusion by surface hydrophilization and amidation through plasma treatment to the inner surface of polyethylene tubes
Biliary stents are medical devices inserted into the bile duct to treat biliary strictures. However, inserted stents can become occluded within a few months after placement. In this study, the inner surface of a polyethylene (PE) tube was plasma-treated with helium (He), nitrogen (N2), oxygen (O2), and their gas mixtures to improve resistance to stent occlusion. Surface characteristics were analyzed by water contact angle (WCA) and x-ray photoelectron spectroscopy (XPS) measurements. In the WCA results, bare PE without plasma treatment was the most hydrophobic at 100.7°, whereas PE(He) plasma-treated with He gas became the most hydrophilic at 26.1°. XPS deconvolution analysis revealed that the PE(He) and PE(He/N2) contained a considerable proportion of O 1s present as amide (–CONH–) groups exceeding 40%, whereas the other samples had proportions below 7%. The resistance to stent occlusion was verified through microbial and cancer cell adhesion assays. In the microbial adhesion assay, Escherichia coli (E. coli) was used, and PE(He) showed a statistically significant reduction in E. coli growth compared to bare PE. Inhibition of cancer cell adhesion was the most pronounced in PE(He) and PE(He/N2), with reductions in fluorescence intensities of 75.5% and 81.5%, respectively. Overall, both surface hydrophilization and amidation were found to be effective in inhibiting the adhesion of organic contaminants. It was proposed that plasma surface treatment has the potential to improve resistance to biliary stent occlusion.
- 18 July 2024
- Published by Wiley in Advanced Engineering Materials
- Vol. 26 (20)
Chromium Coatings Applied to Zr Alloy Claddings by Cathodic Arc Ion Plating: Effect of Nitrogen Inclusion on Limiting Columnar Defects
The effect of nitrogen on an anticorrosive Cr coating for the Zr alloy cladding of nuclear fuel rods is investigated. It is aimed to reduce the number of typical columnar defects generated in Cr‐based coatings when using the cathodic arc ion plating method through reactive nitrogen inclusion and improve the oxidation resistance. Under a working pressure of 5 Pa and an arc current of 60 A in a chrome target, Cr‐based coatings are fabricated under varying N 2 /Ar gas flow ratios and substrate biases. The growth structures, crystallography, and corrosion behavior of the coatings are characterized using scanning electron microscopy, X‐ray diffraction, and potentiodynamic polarization tests. The Cr coating exhibits a typical columnar structure with voids, pores, and columnar defects. In comparison, through nitrogen inclusion, when the nitrogen content of the Cr‐based coating is less than 15 at%, the Cr(N) coating shows a “featureless structure” similar to an amorphous structure, resulting in fewer voids and defects. Potentiodynamic polarization tests reveal that the Cr(N) coating, featuring a distorted body‐centered cubic‐Cr structure, exhibits a significantly low corrosion current in the passive region. The protection efficiency of the Cr(N) coating is calculated to be 96.9%, confirming its superior substrate protection capabilities compared with chromium nitride coatings.
- 18 July 2024
- Published by Wiley in Advanced Engineering Materials
- Vol. 26 (20)
Chromium Coatings Applied to Zr Alloy Claddings by Cathodic Arc Ion Plating: Effect of Nitrogen Inclusion on Limiting Columnar Defects
The effect of nitrogen on an anticorrosive Cr coating for the Zr alloy cladding of nuclear fuel rods is investigated. It is aimed to reduce the number of typical columnar defects generated in Cr‐based coatings when using the cathodic arc ion plating method through reactive nitrogen inclusion and improve the oxidation resistance. Under a working pressure of 5 Pa and an arc current of 60 A in a chrome target, Cr‐based coatings are fabricated under varying N 2 /Ar gas flow ratios and substrate biases. The growth structures, crystallography, and corrosion behavior of the coatings are characterized using scanning electron microscopy, X‐ray diffraction, and potentiodynamic polarization tests. The Cr coating exhibits a typical columnar structure with voids, pores, and columnar defects. In comparison, through nitrogen inclusion, when the nitrogen content of the Cr‐based coating is less than 15 at%, the Cr(N) coating shows a “featureless structure” similar to an amorphous structure, resulting in fewer voids and defects. Potentiodynamic polarization tests reveal that the Cr(N) coating, featuring a distorted body‐centered cubic‐Cr structure, exhibits a significantly low corrosion current in the passive region. The protection efficiency of the Cr(N) coating is calculated to be 96.9%, confirming its superior substrate protection capabilities compared with chromium nitride coatings.
- Open Access
- 1 January 2023
- Published by XMLink in Investigative and Clinical Urology
- Vol. 64 (2) , 175-181
Inner surface modification of polyurethane ureteral stents using plasma-enhanced chemical vapor deposition to improve the resistance to encrustation in a pig model
Chung JH, et al. Investig Clin Urol. 2023 Mar;64(2):175-181. https://doi.org/10.4111/icu.20220393
- 1 January 2023
- Published by XMLink in Investigative and Clinical Urology
- Vol. 64 (2) , 175-181
Open AccessInner surface modification of polyurethane ureteral stents using plasma-enhanced chemical vapor deposition to improve the resistance to encrustation in a pig model
Chung JH, et al. Investig Clin Urol. 2023 Mar;64(2):175-181. https://doi.org/10.4111/icu.20220393
- 30 August 2008
- Published by Elsevier in Surface and Coatings Technology
- Vol. 202 (22-23) , 5390-5394
Synthesis of conductive Ti–C:H films on the stainless steel plates by PECVD process
- 30 August 2008
- Published by Elsevier in Surface and Coatings Technology
- Vol. 202 (22-23) , 5390-5394
Synthesis of conductive Ti–C:H films on the stainless steel plates by PECVD process
- 1 January 2005
- Published by Springer Nature in MRS Proceedings
- Vol. 890
Effects of Preferred Orientation on the Tribological Behavior of the TiN and CrN Films by the CAIP
- 1 January 2005
- Published by Springer Nature in MRS Proceedings
- Vol. 890
Effects of Preferred Orientation on the Tribological Behavior of the TiN and CrN Films by the CAIP
- 1 January 2005
- Published by Springer Nature in MRS Proceedings
- Vol. 903
A Study on the Tribological Properties of DLC Films Deposited with Different Reaction Gases
- 1 January 2005
- Published by Springer Nature in MRS Proceedings
- Vol. 903
A Study on the Tribological Properties of DLC Films Deposited with Different Reaction Gases