Chanyong Seo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chanyong Seo has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Donggeun Jung
Department of Physics, Sungkyunkwan University, Suwon, Republic of Korea
4 shared publications - Namwuk Baek
Department of Physics, Sungkyunkwan University, Suwon, Republic of Korea
4 shared publications - Hyuna Lim
Sungkyunkwan Univ, Dept Phys, Suwon 16419, South Korea
2 shared publications - Seonhee Jang
Department of Mechanical Engineering, University of Louisiana at Lafayette, Lafayette, USA
2 shared publications - Yong Ki Cho
Customized Manufacturing R&D Department, Korea Institute of Industrial Technology 6 , 113-58, Seohaean-ro, Siheung-si, Gyeonggi-do 15014
2 shared publications - Deok Hyun Han
Department of Urology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- 1 March 2026
- Published by American Vacuum Society in Biointerphases
- Vol. 21 (2)
Improving resistance to biliary stent occlusion by surface hydrophilization and amidation through plasma treatment to the inner surface of polyethylene tubes
Biliary stents are medical devices inserted into the bile duct to treat biliary strictures. However, inserted stents can become occluded within a few months after placement. In this study, the inner surface of a polyethylene (PE) tube was plasma-treated with helium (He), nitrogen (N2), oxygen (O2), and their gas mixtures to improve resistance to stent occlusion. Surface characteristics were analyzed by water contact angle (WCA) and x-ray photoelectron spectroscopy (XPS) measurements. In the WCA results, bare PE without plasma treatment was the most hydrophobic at 100.7°, whereas PE(He) plasma-treated with He gas became the most hydrophilic at 26.1°. XPS deconvolution analysis revealed that the PE(He) and PE(He/N2) contained a considerable proportion of O 1s present as amide (–CONH–) groups exceeding 40%, whereas the other samples had proportions below 7%. The resistance to stent occlusion was verified through microbial and cancer cell adhesion assays. In the microbial adhesion assay, Escherichia coli (E. coli) was used, and PE(He) showed a statistically significant reduction in E. coli growth compared to bare PE. Inhibition of cancer cell adhesion was the most pronounced in PE(He) and PE(He/N2), with reductions in fluorescence intensities of 75.5% and 81.5%, respectively. Overall, both surface hydrophilization and amidation were found to be effective in inhibiting the adhesion of organic contaminants. It was proposed that plasma surface treatment has the potential to improve resistance to biliary stent occlusion.
- 1 March 2026
- Published by American Vacuum Society in Biointerphases
- Vol. 21 (2)
Improving resistance to biliary stent occlusion by surface hydrophilization and amidation through plasma treatment to the inner surface of polyethylene tubes
Biliary stents are medical devices inserted into the bile duct to treat biliary strictures. However, inserted stents can become occluded within a few months after placement. In this study, the inner surface of a polyethylene (PE) tube was plasma-treated with helium (He), nitrogen (N2), oxygen (O2), and their gas mixtures to improve resistance to stent occlusion. Surface characteristics were analyzed by water contact angle (WCA) and x-ray photoelectron spectroscopy (XPS) measurements. In the WCA results, bare PE without plasma treatment was the most hydrophobic at 100.7°, whereas PE(He) plasma-treated with He gas became the most hydrophilic at 26.1°. XPS deconvolution analysis revealed that the PE(He) and PE(He/N2) contained a considerable proportion of O 1s present as amide (–CONH–) groups exceeding 40%, whereas the other samples had proportions below 7%. The resistance to stent occlusion was verified through microbial and cancer cell adhesion assays. In the microbial adhesion assay, Escherichia coli (E. coli) was used, and PE(He) showed a statistically significant reduction in E. coli growth compared to bare PE. Inhibition of cancer cell adhesion was the most pronounced in PE(He) and PE(He/N2), with reductions in fluorescence intensities of 75.5% and 81.5%, respectively. Overall, both surface hydrophilization and amidation were found to be effective in inhibiting the adhesion of organic contaminants. It was proposed that plasma surface treatment has the potential to improve resistance to biliary stent occlusion.
- 12 March 2025
- Published by Springer Nature in Journal of Materials Research
- Vol. 40 (7) , 1088-1097
Introducing tris(trimethylsiloxy)silane as a new precursor for low-k thin films in plasma-enhanced chemical vapor deposition system
- 12 March 2025
- Published by Springer Nature in Journal of Materials Research
- Vol. 40 (7) , 1088-1097
Introducing tris(trimethylsiloxy)silane as a new precursor for low-k thin films in plasma-enhanced chemical vapor deposition system
- 2 September 2024
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 13 (9) , 093008
Effects of Diethoxymethylsilane/Helium Flow Rate Ratio on Low-k Films Deposited by Plasma-Enhanced Chemical Vapor Deposition
As the semiconductor industry has continuously reduced the integrated circuit (IC) chip size, a resistance-capacitance (RC) delay emerged, causing deterioration of the chip performance. To reduce the RC delay, low dielectric constant (low-k) films with suitable mechanical strengths have been adopted as intermetal dielectrics (IMDs). In this study, low-k plasma-polymerized diethoxymethylsilane (ppDEMS) films were fabricated by plasma-enhanced chemical vapor deposition of the DEMS precursor with a flow rate ratio of the DEMS precursor to helium (He) carrier gas (DEMS/He FRR) as a key parameter. As the DEMS/He FRR increased, the refractive index was reduced from 1.401 to 1.386, and the k value decreased from 2.77 to 2.10. From high-resolution scans of C1s, O1s, and Si2p peaks of X-ray photoelectron spectroscopy, the carbon contents increased, and the oxygen contents decreased, along with a decrease in the film density. With the increased DEMS/He FRR, hardness decreased from 2.5 to 1.8 GPa, and elastic modulus decreased from 17.08 to 11.50 GPa. Leakage current densities for all the ppDEMS films were less than 10−7 A cm−2 at 1 MV cm−1. The ppDEMS films could be suggested as the IMDs according to their electrical and mechanical performance.
- 2 September 2024
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 13 (9) , 093008
Effects of Diethoxymethylsilane/Helium Flow Rate Ratio on Low-k Films Deposited by Plasma-Enhanced Chemical Vapor Deposition
As the semiconductor industry has continuously reduced the integrated circuit (IC) chip size, a resistance-capacitance (RC) delay emerged, causing deterioration of the chip performance. To reduce the RC delay, low dielectric constant (low-k) films with suitable mechanical strengths have been adopted as intermetal dielectrics (IMDs). In this study, low-k plasma-polymerized diethoxymethylsilane (ppDEMS) films were fabricated by plasma-enhanced chemical vapor deposition of the DEMS precursor with a flow rate ratio of the DEMS precursor to helium (He) carrier gas (DEMS/He FRR) as a key parameter. As the DEMS/He FRR increased, the refractive index was reduced from 1.401 to 1.386, and the k value decreased from 2.77 to 2.10. From high-resolution scans of C1s, O1s, and Si2p peaks of X-ray photoelectron spectroscopy, the carbon contents increased, and the oxygen contents decreased, along with a decrease in the film density. With the increased DEMS/He FRR, hardness decreased from 2.5 to 1.8 GPa, and elastic modulus decreased from 17.08 to 11.50 GPa. Leakage current densities for all the ppDEMS films were less than 10−7 A cm−2 at 1 MV cm−1. The ppDEMS films could be suggested as the IMDs according to their electrical and mechanical performance.
- Open Access
- 1 January 2023
- Published by XMLink in Investigative and Clinical Urology
- Vol. 64 (2) , 175-181
Inner surface modification of polyurethane ureteral stents using plasma-enhanced chemical vapor deposition to improve the resistance to encrustation in a pig model
Chung JH, et al. Investig Clin Urol. 2023 Mar;64(2):175-181. https://doi.org/10.4111/icu.20220393
- 1 January 2023
- Published by XMLink in Investigative and Clinical Urology
- Vol. 64 (2) , 175-181
Open AccessInner surface modification of polyurethane ureteral stents using plasma-enhanced chemical vapor deposition to improve the resistance to encrustation in a pig model
Chung JH, et al. Investig Clin Urol. 2023 Mar;64(2):175-181. https://doi.org/10.4111/icu.20220393