Sebastien Berujon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sebastien Berujon has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Eric Ziegler
European Synchrotron Radiation Facility CS 40220 F-38043 Grenoble cedex 9 France
15 shared publicationsKawal Sawhney
Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot, OX11 0DE, UK
14 shared publicationsHongchang Wang
Diamond Light Source Ltd. (United Kingdom)
9 shared publications- Emmanuel Brun
Université Grenoble Alpes, Inserm UA7Strobe Laboratory, 38000 Grenoble, France
8 shared publications - Hongchang Wang
Diamond Light Source
7 shared publications - Helene Labriet
Novitom, 3 avenue du Doyen Louis Weil 38000 Grenoble, France
6 shared publications
Latest Publications
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Métrologie en ligne de faisceaux et d'optiques X de synchrotrons
Cette thèse présente des travaux de recherche de métrologie en ligne de faisceaux de rayons X dans les installations synchrotrons. Deux approches principales ont été étudiées pour extraire la phase d'un front d'onde X : les méthodes utilisant des réseaux optiques et celles utilisant l'effet speckle dans le domaine X. L'interféromètre à réseaux X est l'outil le plus répandu résentatif de la première catégorie. Ses performances et son potentiel furent étudiés dans diverses situations de métrologie en ligne. Les méthodes utilisant le speckle X sont des techniques originales développées au cours de ce projet. Elles utilisent des membranes faites de petits grains diffusants, dont seule la distribution statistique est connue, pour permettre la modulation du front d'onde. Les différentes techniques furent déployées expérimentalement sur les lignes de lumière BM05 de l'ESRF et B16 de Diamond Light Source. Leurs implémentations servirent à la caractérisation de différents composants optiques utilisés pour manipuler les faisceaux synchrotron X et à l'étude de la faisabilité de micro imagerie par contraste de phase avec les sus citées techniques.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Métrologie en ligne de faisceaux et d'optiques X de synchrotrons
Cette thèse présente des travaux de recherche de métrologie en ligne de faisceaux de rayons X dans les installations synchrotrons. Deux approches principales ont été étudiées pour extraire la phase d'un front d'onde X : les méthodes utilisant des réseaux optiques et celles utilisant l'effet speckle dans le domaine X. L'interféromètre à réseaux X est l'outil le plus répandu résentatif de la première catégorie. Ses performances et son potentiel furent étudiés dans diverses situations de métrologie en ligne. Les méthodes utilisant le speckle X sont des techniques originales développées au cours de ce projet. Elles utilisent des membranes faites de petits grains diffusants, dont seule la distribution statistique est connue, pour permettre la modulation du front d'onde. Les différentes techniques furent déployées expérimentalement sur les lignes de lumière BM05 de l'ESRF et B16 de Diamond Light Source. Leurs implémentations servirent à la caractérisation de différents composants optiques utilisés pour manipuler les faisceaux synchrotron X et à l'étude de la faisabilité de micro imagerie par contraste de phase avec les sus citées techniques.
- 2 November 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (5) , 053505
Directional dark-field implicit x-ray speckle tracking using an anisotropic-diffusion Fokker-Planck equation
When a macroscopic-sized noncrystalline sample is illuminated using coherent x-ray radiation, a bifurcation of photon energy flow may occur. The coarse-grained complex refractive index of the sample may be considered to attenuate and refract the incident coherent beam, leading to a coherent component of the transmitted beam. Spatially unresolved sample microstructure, associated with the fine-grained components of the complex refractive index, introduces a diffuse component to the transmitted beam. This diffuse photon-scattering channel may be viewed in terms of position-dependent fans of ultrasmall-angle x-ray scatter. These position-dependent fans, at the exit surface of the object, may under certain circumstances be approximated as having a locally elliptical shape. By using an anisotropic-diffusion Fokker-Planck approach to model this bifurcated x-ray energy flow, we show how all three components (attenuation, refraction, and locally elliptical diffuse scatter) may be recovered. This is done via x-ray speckle tracking, in which the sample is illuminated with spatially random x-ray fields generated by coherent illumination of a spatially random membrane. The theory is developed and then successfully applied to experimental x-ray data.
- 2 November 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (5) , 053505
Directional dark-field implicit x-ray speckle tracking using an anisotropic-diffusion Fokker-Planck equation
When a macroscopic-sized noncrystalline sample is illuminated using coherent x-ray radiation, a bifurcation of photon energy flow may occur. The coarse-grained complex refractive index of the sample may be considered to attenuate and refract the incident coherent beam, leading to a coherent component of the transmitted beam. Spatially unresolved sample microstructure, associated with the fine-grained components of the complex refractive index, introduces a diffuse component to the transmitted beam. This diffuse photon-scattering channel may be viewed in terms of position-dependent fans of ultrasmall-angle x-ray scatter. These position-dependent fans, at the exit surface of the object, may under certain circumstances be approximated as having a locally elliptical shape. By using an anisotropic-diffusion Fokker-Planck approach to model this bifurcated x-ray energy flow, we show how all three components (attenuation, refraction, and locally elliptical diffuse scatter) may be recovered. This is done via x-ray speckle tracking, in which the sample is illuminated with spatially random x-ray fields generated by coherent illumination of a spatially random membrane. The theory is developed and then successfully applied to experimental x-ray data.
- 11 November 2020
- Published by IOP Publishing in Journal of Optics
- Vol. 22 (12) , 125604
X-ray multi-modal intrinsic-speckle-tracking
We develop x-ray multi-modal intrinsic-speckle-tracking (MIST), a form of x-ray speckle-tracking that is able to recover both the position-dependent phase shift and the position-dependent small-angle x-ray scattering (SAXS) signal of a phase object. MIST is based on combining a Fokker–Planck description of paraxial x-ray optics, with an optical-flow formalism for x-ray speckle-tracking. Only two images need to be taken in the presence of the sample, corresponding to two different transverse positions of the speckle-generating membrane, in order to recover both the refractive and local-SAXS properties of the sample. Like the optical-flow x-ray phase-retrieval method which it generalises, the MIST method implicitly rather than explicitly tracks both the transverse motion and the diffusion of speckles that is induced by the presence of a sample. Application to x-ray synchrotron data shows the method to be efficient, rapid and stable.
- 11 November 2020
- Published by IOP Publishing in Journal of Optics
- Vol. 22 (12) , 125604
X-ray multi-modal intrinsic-speckle-tracking
We develop x-ray multi-modal intrinsic-speckle-tracking (MIST), a form of x-ray speckle-tracking that is able to recover both the position-dependent phase shift and the position-dependent small-angle x-ray scattering (SAXS) signal of a phase object. MIST is based on combining a Fokker–Planck description of paraxial x-ray optics, with an optical-flow formalism for x-ray speckle-tracking. Only two images need to be taken in the presence of the sample, corresponding to two different transverse positions of the speckle-generating membrane, in order to recover both the refractive and local-SAXS properties of the sample. Like the optical-flow x-ray phase-retrieval method which it generalises, the MIST method implicitly rather than explicitly tracks both the transverse motion and the diffusion of speckles that is induced by the presence of a sample. Application to x-ray synchrotron data shows the method to be efficient, rapid and stable.
- 11 May 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 13 (5) , 054023
Single-Shot X-Ray Speckle-Based Imaging of a Single-Material Object
We develop a means for speckle-based phase imaging of the projected thickness of a single-material object, under the assumption of illumination by spatially random time-independent x-ray speckles. These speckles are generated by passing x rays through a suitable spatially random mask. The method makes use of a single image obtained in the presence of the object, which serves to deform the illuminating speckle field relative to a reference speckle field (which only needs to be measured once) obtained in the presence of the mask and the absence of the object. The method implicitly rather than explicitly tracks speckles and utilizes the transport-of-intensity equation to give a closed-form solution to the inverse problem of determining the complex transmission function of the object. Implementation using x-ray synchrotron data shows the method to be robust and efficient with respect to noise. Applications include x-ray phase-amplitude radiography and tomography, as well as time-dependent imaging of dynamic and radiation-sensitive samples using low-flux sources.
- 11 May 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 13 (5) , 054023
Single-Shot X-Ray Speckle-Based Imaging of a Single-Material Object
We develop a means for speckle-based phase imaging of the projected thickness of a single-material object, under the assumption of illumination by spatially random time-independent x-ray speckles. These speckles are generated by passing x rays through a suitable spatially random mask. The method makes use of a single image obtained in the presence of the object, which serves to deform the illuminating speckle field relative to a reference speckle field (which only needs to be measured once) obtained in the presence of the mask and the absence of the object. The method implicitly rather than explicitly tracks speckles and utilizes the transport-of-intensity equation to give a closed-form solution to the inverse problem of determining the complex transmission function of the object. Implementation using x-ray synchrotron data shows the method to be robust and efficient with respect to noise. Applications include x-ray phase-amplitude radiography and tomography, as well as time-dependent imaging of dynamic and radiation-sensitive samples using low-flux sources.
- Open Access
X-ray optics and beam characterization using random modulation: Theory
X-ray near-field speckle-based phase-sensing approaches provide efficient means to characterise optical elements. Here, we present a theoretical review of several of these speckle methods in the frame of optical characterisation and provide a generalization of the concept. As we also demonstrate experimentally in another paper, the methods theoretically developed here can be applied with different beams and optics and within a variety of situations where at-wavelength metrology is desired. By understanding the differences between the various processing methods, it is possible to find and implement the best suited approach for each metrology scenario.
Open AccessX-ray optics and beam characterization using random modulation: Theory
X-ray near-field speckle-based phase-sensing approaches provide efficient means to characterise optical elements. Here, we present a theoretical review of several of these speckle methods in the frame of optical characterisation and provide a generalization of the concept. As we also demonstrate experimentally in another paper, the methods theoretically developed here can be applied with different beams and optics and within a variety of situations where at-wavelength metrology is desired. By understanding the differences between the various processing methods, it is possible to find and implement the best suited approach for each metrology scenario.
- Open Access
- 20 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 284-292
X-ray optics and beam characterization using random modulation: theory
X-ray near-field speckle-based phase-sensing approaches provide efficient means of characterizing optical elements. Presented here is a theoretical review of several of these speckle methods within the framework of optical characterization, and a generalization of the concept is provided. As is also demonstrated experimentally in a parallel paper [Berujon, Cojocaru, Piault, Celestre, Roth, Barrett & Ziegler (2020), J. Synchrotron Rad. 27, (this issue)], the methods theoretically developed here can be applied to different beams and optics and within a variety of situations where at-wavelength metrology is desired. By understanding the differences between the various processing methods, it is possible to find and implement the most suitable approach for each metrology scenario.
- 20 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 284-292
Open AccessX-ray optics and beam characterization using random modulation: theory
X-ray near-field speckle-based phase-sensing approaches provide efficient means of characterizing optical elements. Presented here is a theoretical review of several of these speckle methods within the framework of optical characterization, and a generalization of the concept is provided. As is also demonstrated experimentally in a parallel paper [Berujon, Cojocaru, Piault, Celestre, Roth, Barrett & Ziegler (2020), J. Synchrotron Rad. 27, (this issue)], the methods theoretically developed here can be applied to different beams and optics and within a variety of situations where at-wavelength metrology is desired. By understanding the differences between the various processing methods, it is possible to find and implement the most suitable approach for each metrology scenario.
- 20 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 293-304
X-ray optics and beam characterization using random modulation: experiments
A parallel paper [Berujon, Cojocaru, Piault, Celestre, Roth, Barrett & Ziegler (2020),J. Synchrotron Rad.27, 284–292] reviewed theoretically some of the available processing schemes for X-ray wavefront sensing based on random modulation. Shown here are experimental applications of the technique for characterizing both refractive and reflective optical components. These fast and accurate X-ray at-wavelength metrology methods can assist the manufacture of X-ray optics that transport X-ray beams with a minimum amount of wavefront distortion. It is also recalled how such methods can facilitate online optimization of active optics.
- 20 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 293-304
X-ray optics and beam characterization using random modulation: experiments
A parallel paper [Berujon, Cojocaru, Piault, Celestre, Roth, Barrett & Ziegler (2020),J. Synchrotron Rad.27, 284–292] reviewed theoretically some of the available processing schemes for X-ray wavefront sensing based on random modulation. Shown here are experimental applications of the technique for characterizing both refractive and reflective optical components. These fast and accurate X-ray at-wavelength metrology methods can assist the manufacture of X-ray optics that transport X-ray beams with a minimum amount of wavefront distortion. It is also recalled how such methods can facilitate online optimization of active optics.
- Open Access
- 11 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 305-318
Modelling phase imperfections in compound refractive lenses
A framework based on physical optics for simulating the effect of imperfect compound refractive lenses (CRLs) upon an X-ray beam is described, taking into account measured phase errors obtained from at-wavelength metrology. A CRL stack is modelled, with increasing complexity, as a single thin phase element, then as a more realistic compound element including absorption and thickness effects, and finally adding realistic optical imperfections to the CRL. Coherent and partially coherent simulations using Synchrotron Radiation Workshop (SRW) are used to evaluate the different models, the effects of the phase errors and to check the validity of the design equations and suitability of the figures of merit.
- 11 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 305-318
Open AccessModelling phase imperfections in compound refractive lenses
A framework based on physical optics for simulating the effect of imperfect compound refractive lenses (CRLs) upon an X-ray beam is described, taking into account measured phase errors obtained from at-wavelength metrology. A CRL stack is modelled, with increasing complexity, as a single thin phase element, then as a more realistic compound element including absorption and thickness effects, and finally adding realistic optical imperfections to the CRL. Coherent and partially coherent simulations using Synchrotron Radiation Workshop (SRW) are used to evaluate the different models, the effects of the phase errors and to check the validity of the design equations and suitability of the figures of merit.
- Open Access
- 5 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
X-ray Phase Contrast osteo-articular imaging: a pilot study on cadaveric human hands
X-ray Phase Contrast Imaging (PCI) is an emerging modality whose availability in clinics for mammography and lung imaging is expected to materialize within the coming years. In this study, we evaluate the PCI Computed Tomography (PCI-CT) performances with respect to current conventional imaging modalities in the context of osteo-articular disorders diagnosis. X-ray PCI-CT was performed on 3 cadaveric human hands and wrists using a synchrotron beam. Conventional CT, MRI and Ultrasound were also performed on these three samples using routine procedures as well as research protocols. Six radiologists and rheumatologists independently evaluated qualitatively and semi quantitatively the 3D images’ quality. Medical interpretations were also made from the images. PCI-CT allows the simultaneous visualization of both the high absorbing and the softer tissues. The 6 reader evaluations characterized PCI-CT as a visualization tool with improved performances for all tissue types (significant p-values), which provides sharper outlines and clearer internal structures than images obtained using conventional modalities. The PCI-CT images contain overall more information, especially at smaller scales with for instance more visible micro-calcifications in our chondrocalcinosis case. Despite a reduced number of samples used, this pilot study highlights the possible medical benefits of PCI for osteo-articular disorders evaluation. Although PCI-CT is not yet available in hospitals, the improved visualization capabilities demonstrated so far and the enhanced tissue measurement quality let suggest strong diagnosis benefits for rheumatology in case of a widespread application of PCI.
- 5 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
Open AccessX-ray Phase Contrast osteo-articular imaging: a pilot study on cadaveric human hands
X-ray Phase Contrast Imaging (PCI) is an emerging modality whose availability in clinics for mammography and lung imaging is expected to materialize within the coming years. In this study, we evaluate the PCI Computed Tomography (PCI-CT) performances with respect to current conventional imaging modalities in the context of osteo-articular disorders diagnosis. X-ray PCI-CT was performed on 3 cadaveric human hands and wrists using a synchrotron beam. Conventional CT, MRI and Ultrasound were also performed on these three samples using routine procedures as well as research protocols. Six radiologists and rheumatologists independently evaluated qualitatively and semi quantitatively the 3D images’ quality. Medical interpretations were also made from the images. PCI-CT allows the simultaneous visualization of both the high absorbing and the softer tissues. The 6 reader evaluations characterized PCI-CT as a visualization tool with improved performances for all tissue types (significant p-values), which provides sharper outlines and clearer internal structures than images obtained using conventional modalities. The PCI-CT images contain overall more information, especially at smaller scales with for instance more visible micro-calcifications in our chondrocalcinosis case. Despite a reduced number of samples used, this pilot study highlights the possible medical benefits of PCI for osteo-articular disorders evaluation. Although PCI-CT is not yet available in hospitals, the improved visualization capabilities demonstrated so far and the enhanced tissue measurement quality let suggest strong diagnosis benefits for rheumatology in case of a widespread application of PCI.
- Open Access
X-ray optics and beam characterisation using random modulation: Experiments
In a previous paper, we reviewed theoretically some of the available processing schemes for X-ray wavefront sensing based on random modulation. We here show experimental applications of the technique for characterising both refractive and reflective optical components. These fast and accurate X-ray at-wavelength metrology methods can assist the manufacture of X-ray optics that transport X-ray beams with minimum amount of wavefront distortion. We also recall how such methods can facilitate online optimization of active optics.
Open AccessX-ray optics and beam characterisation using random modulation: Experiments
In a previous paper, we reviewed theoretically some of the available processing schemes for X-ray wavefront sensing based on random modulation. We here show experimental applications of the technique for characterising both refractive and reflective optical components. These fast and accurate X-ray at-wavelength metrology methods can assist the manufacture of X-ray optics that transport X-ray beams with minimum amount of wavefront distortion. We also recall how such methods can facilitate online optimization of active optics.