SBSebastien Berujon

Sebastien Berujon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sebastien Berujon has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Métrologie en ligne de faisceaux et d'optiques X de synchrotrons

    by Sébastien Bérujon

    Cette thèse présente des travaux de recherche de métrologie en ligne de faisceaux de rayons X dans les installations synchrotrons. Deux approches principales ont été étudiées pour extraire la phase d'un front d'onde X : les méthodes utilisant des réseaux optiques et celles utilisant l'effet speckle dans le domaine X. L'interféromètre à réseaux X est l'outil le plus répandu résentatif de la première catégorie. Ses performances et son potentiel furent étudiés dans diverses situations de métrologie en ligne. Les méthodes utilisant le speckle X sont des techniques originales développées au cours de ce projet. Elles utilisent des membranes faites de petits grains diffusants, dont seule la distribution statistique est connue, pour permettre la modulation du front d'onde. Les différentes techniques furent déployées expérimentalement sur les lignes de lumière BM05 de l'ESRF et B16 de Diamond Light Source. Leurs implémentations servirent à la caractérisation de différents composants optiques utilisés pour manipuler les faisceaux synchrotron X et à l'étude de la faisabilité de micro imagerie par contraste de phase avec les sus citées techniques.

  • Directional dark-field implicit x-ray speckle tracking using an anisotropic-diffusion Fokker-Planck equation

    by Konstantin M. Pavlov, David M. Paganin, Kaye S. Morgan, Heyang (Thomas) Li, Sebastien Berujon, Laurène Quénot, Emmanuel Brun

    When a macroscopic-sized noncrystalline sample is illuminated using coherent x-ray radiation, a bifurcation of photon energy flow may occur. The coarse-grained complex refractive index of the sample may be considered to attenuate and refract the incident coherent beam, leading to a coherent component of the transmitted beam. Spatially unresolved sample microstructure, associated with the fine-grained components of the complex refractive index, introduces a diffuse component to the transmitted beam. This diffuse photon-scattering channel may be viewed in terms of position-dependent fans of ultrasmall-angle x-ray scatter. These position-dependent fans, at the exit surface of the object, may under certain circumstances be approximated as having a locally elliptical shape. By using an anisotropic-diffusion Fokker-Planck approach to model this bifurcated x-ray energy flow, we show how all three components (attenuation, refraction, and locally elliptical diffuse scatter) may be recovered. This is done via x-ray speckle tracking, in which the sample is illuminated with spatially random x-ray fields generated by coherent illumination of a spatially random membrane. The theory is developed and then successfully applied to experimental x-ray data.


  • X-ray multi-modal intrinsic-speckle-tracking

    by Konstantin M Pavlov, David M Paganin, Heyang (Thomas) Li, Sebastien Berujon, Hélène Rougé-Labriet, Emmanuel Brun

    We develop x-ray multi-modal intrinsic-speckle-tracking (MIST), a form of x-ray speckle-tracking that is able to recover both the position-dependent phase shift and the position-dependent small-angle x-ray scattering (SAXS) signal of a phase object. MIST is based on combining a Fokker–Planck description of paraxial x-ray optics, with an optical-flow formalism for x-ray speckle-tracking. Only two images need to be taken in the presence of the sample, corresponding to two different transverse positions of the speckle-generating membrane, in order to recover both the refractive and local-SAXS properties of the sample. Like the optical-flow x-ray phase-retrieval method which it generalises, the MIST method implicitly rather than explicitly tracks both the transverse motion and the diffusion of speckles that is induced by the presence of a sample. Application to x-ray synchrotron data shows the method to be efficient, rapid and stable.


  • Single-Shot X-Ray Speckle-Based Imaging of a Single-Material Object

    by Konstantin M. Pavlov, Heyang (Thomas) Li, David M. Paganin, Sebastien Berujon, Hélène Rougé-Labriet, Emmanuel Brun

    We develop a means for speckle-based phase imaging of the projected thickness of a single-material object, under the assumption of illumination by spatially random time-independent x-ray speckles. These speckles are generated by passing x rays through a suitable spatially random mask. The method makes use of a single image obtained in the presence of the object, which serves to deform the illuminating speckle field relative to a reference speckle field (which only needs to be measured once) obtained in the presence of the mask and the absence of the object. The method implicitly rather than explicitly tracks speckles and utilizes the transport-of-intensity equation to give a closed-form solution to the inverse problem of determining the complex transmission function of the object. Implementation using x-ray synchrotron data shows the method to be robust and efficient with respect to noise. Applications include x-ray phase-amplitude radiography and tomography, as well as time-dependent imaging of dynamic and radiation-sensitive samples using low-flux sources.


  • Open Access

    X-ray optics and beam characterization using random modulation: Theory

    by Sebastien Berujon, Ruxandra Cojocaru, Pierre Piault, Rafael Celestre, Thomas Roth, Raymond Barrett, Eric Ziegler

    X-ray near-field speckle-based phase-sensing approaches provide efficient means to characterise optical elements. Here, we present a theoretical review of several of these speckle methods in the frame of optical characterisation and provide a generalization of the concept. As we also demonstrate experimentally in another paper, the methods theoretically developed here can be applied with different beams and optics and within a variety of situations where at-wavelength metrology is desired. By understanding the differences between the various processing methods, it is possible to find and implement the best suited approach for each metrology scenario.

  • Open Access

    X-ray optics and beam characterization using random modulation: theory

    by Sebastien Berujon, Ruxandra Cojocaru, Pierre Piault, Rafael Celestre, Thomas Roth, Raymond Barrett, Eric Ziegler

    X-ray near-field speckle-based phase-sensing approaches provide efficient means of characterizing optical elements. Presented here is a theoretical review of several of these speckle methods within the framework of optical characterization, and a generalization of the concept is provided. As is also demonstrated experimentally in a parallel paper [Berujon, Cojocaru, Piault, Celestre, Roth, Barrett & Ziegler (2020), J. Synchrotron Rad. 27, (this issue)], the methods theoretically developed here can be applied to different beams and optics and within a variety of situations where at-wavelength metrology is desired. By understanding the differences between the various processing methods, it is possible to find and implement the most suitable approach for each metrology scenario.


  • X-ray optics and beam characterization using random modulation: experiments

    by Sebastien Berujon, Ruxandra Cojocaru, Pierre Piault, Rafael Celestre, Thomas Roth, Raymond Barrett, Eric Ziegler

    A parallel paper [Berujon, Cojocaru, Piault, Celestre, Roth, Barrett & Ziegler (2020),J. Synchrotron Rad.27, 284–292] reviewed theoretically some of the available processing schemes for X-ray wavefront sensing based on random modulation. Shown here are experimental applications of the technique for characterizing both refractive and reflective optical components. These fast and accurate X-ray at-wavelength metrology methods can assist the manufacture of X-ray optics that transport X-ray beams with a minimum amount of wavefront distortion. It is also recalled how such methods can facilitate online optimization of active optics.


  • Open Access

    Modelling phase imperfections in compound refractive lenses

    by Rafael Celestre, Sebastien Berujon, Thomas Roth, Manuel Sanchez del Rio, Raymond Barrett

    A framework based on physical optics for simulating the effect of imperfect compound refractive lenses (CRLs) upon an X-ray beam is described, taking into account measured phase errors obtained from at-wavelength metrology. A CRL stack is modelled, with increasing complexity, as a single thin phase element, then as a more realistic compound element including absorption and thickness effects, and finally adding realistic optical imperfections to the CRL. Coherent and partially coherent simulations using Synchrotron Radiation Workshop (SRW) are used to evaluate the different models, the effects of the phase errors and to check the validity of the design equations and suitability of the figures of merit.


  • Open Access

    X-ray Phase Contrast osteo-articular imaging: a pilot study on cadaveric human hands

    by Hélène Rougé-Labriet, Sebastien Berujon, Hervé Mathieu, Sylvain Bohic, Barbara Fayard, Jean-Noel Ravey, Yohann Robert, Philippe Gaudin, Emmanuel Brun

    X-ray Phase Contrast Imaging (PCI) is an emerging modality whose availability in clinics for mammography and lung imaging is expected to materialize within the coming years. In this study, we evaluate the PCI Computed Tomography (PCI-CT) performances with respect to current conventional imaging modalities in the context of osteo-articular disorders diagnosis. X-ray PCI-CT was performed on 3 cadaveric human hands and wrists using a synchrotron beam. Conventional CT, MRI and Ultrasound were also performed on these three samples using routine procedures as well as research protocols. Six radiologists and rheumatologists independently evaluated qualitatively and semi quantitatively the 3D images’ quality. Medical interpretations were also made from the images. PCI-CT allows the simultaneous visualization of both the high absorbing and the softer tissues. The 6 reader evaluations characterized PCI-CT as a visualization tool with improved performances for all tissue types (significant p-values), which provides sharper outlines and clearer internal structures than images obtained using conventional modalities. The PCI-CT images contain overall more information, especially at smaller scales with for instance more visible micro-calcifications in our chondrocalcinosis case. Despite a reduced number of samples used, this pilot study highlights the possible medical benefits of PCI for osteo-articular disorders evaluation. Although PCI-CT is not yet available in hospitals, the improved visualization capabilities demonstrated so far and the enhanced tissue measurement quality let suggest strong diagnosis benefits for rheumatology in case of a widespread application of PCI.


  • Open Access

    X-ray optics and beam characterisation using random modulation: Experiments

    by Sebastien Berujon, Ruxandra Cojocaru, Pierre Piault, Rafael Celestre, Thomas Roth, Raymond Barrett, Eric Ziegler

    In a previous paper, we reviewed theoretically some of the available processing schemes for X-ray wavefront sensing based on random modulation. We here show experimental applications of the technique for characterising both refractive and reflective optical components. These fast and accurate X-ray at-wavelength metrology methods can assist the manufacture of X-ray optics that transport X-ray beams with minimum amount of wavefront distortion. We also recall how such methods can facilitate online optimization of active optics.