Kylie Dundas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kylie Dundas has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Geoffrey Paul Delaney
Collaboration for Cancer Outcomes Research and Evaluation (CCORE), School of Clinical Medicine University of New South Wales (UNSW) Sydney Australia
5 shared publications - Vikneswary Batumalai
The George Institute for Global Health, UNSW Sydney, Randwick, Australia
4 shared publications - Elise Maree Pogson
Institute for Superconducting and Electronic Materials, University of Wollongong, Wollongong, New South Wales 2522, Australia
3 shared publications - Lois Holloway
South Western Sydney Clinical School, Faculty of Medicine, UNSW, Sydney, Australia
3 shared publications Mei Ling Yap
Liverpool and Macarthur Cancer Therapy Centres, Liverpool, Australia; Ingham Institute for Applied Medical Research, Liverpool, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, Australia; School of Medicine, University of Western Sydney, Sydney, Australia
3 shared publications- Peter Metcalfe
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
3 shared publications
Latest Publications
- 16 January 2026
- Published by Elsevier in Practical Radiation Oncology
- Vol. 16 (4) , 345-362
The Bare Essentials: Exploring Modesty Concerns to Enhance Radiation Therapy Practice and Patient Care
- 16 January 2026
- Published by Elsevier in Practical Radiation Oncology
- Vol. 16 (4) , 345-362
The Bare Essentials: Exploring Modesty Concerns to Enhance Radiation Therapy Practice and Patient Care
- Open Access
- 18 June 2022
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 69 (4) , 473-483
Correcting rotational error in rectal cancer radiation therapy: Can planning target volume margins be safely reduced?
Introduction: The magnitude and impact of rotational error is unclear in rectal cancer radiation therapy. This study evaluates rotational errors in rectal cancer patients, and investigates the feasibility of planning target volume (PTV) margin reduction to decrease organs at risk (OAR) irradiation.Methods: In this study, 10 patients with rectal cancer were retrospectively selected. Rotational errors were assessed through image registration of daily cone beam computed tomography (CBCT) and planning CT scans. Two reference treatment plans (TPR) with PTV margins of 5 mm and 10 mm were generated for each patient. Pre‐determined rotational errors (±1°, ±3°, ±5°) were simulated to produce six manipulated treatment plans (TPM) from each TPR. Differences in evaluated dose‐volume metrics between TPR and TPM of each rotation were compared using Wilcoxon Signed‐Rank Test. Clinical compliance was investigated for statistically significant dose‐volume metrics.Results: Mean rotational errors in pitch, roll and yaw were −0.72 ± 1.81°, −0.04 ± 1.36° and 0.38 ± 0.96° respectively. Pitch resulted in the largest potential circumferential displacement of clinical target volume (CTV) at 1.42 ± 1.06 mm. Pre‐determined rotational errors resulted in statistically significant differences in CTV, small bowel, femoral heads and iliac crests (P < 0.05). Only small bowel and iliac crests failed clinical compliance, with majority in the PTV 10 mm margin group.Conclusion: Rotational errors affected clinical compliance for OAR dose but exerted minimal impact on CTV coverage even with reduced PTV margins. Both PTV margin reduction and rotational correction decreased irradiated volume of OAR. PTV margin reduction to 5 mm is feasible, and rotational corrections are recommended in rectal patients to further minimise OAR irradiation.
- 18 June 2022
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 69 (4) , 473-483
Open AccessCorrecting rotational error in rectal cancer radiation therapy: Can planning target volume margins be safely reduced?
Introduction: The magnitude and impact of rotational error is unclear in rectal cancer radiation therapy. This study evaluates rotational errors in rectal cancer patients, and investigates the feasibility of planning target volume (PTV) margin reduction to decrease organs at risk (OAR) irradiation.Methods: In this study, 10 patients with rectal cancer were retrospectively selected. Rotational errors were assessed through image registration of daily cone beam computed tomography (CBCT) and planning CT scans. Two reference treatment plans (TPR) with PTV margins of 5 mm and 10 mm were generated for each patient. Pre‐determined rotational errors (±1°, ±3°, ±5°) were simulated to produce six manipulated treatment plans (TPM) from each TPR. Differences in evaluated dose‐volume metrics between TPR and TPM of each rotation were compared using Wilcoxon Signed‐Rank Test. Clinical compliance was investigated for statistically significant dose‐volume metrics.Results: Mean rotational errors in pitch, roll and yaw were −0.72 ± 1.81°, −0.04 ± 1.36° and 0.38 ± 0.96° respectively. Pitch resulted in the largest potential circumferential displacement of clinical target volume (CTV) at 1.42 ± 1.06 mm. Pre‐determined rotational errors resulted in statistically significant differences in CTV, small bowel, femoral heads and iliac crests (P < 0.05). Only small bowel and iliac crests failed clinical compliance, with majority in the PTV 10 mm margin group.Conclusion: Rotational errors affected clinical compliance for OAR dose but exerted minimal impact on CTV coverage even with reduced PTV margins. Both PTV margin reduction and rotational correction decreased irradiated volume of OAR. PTV margin reduction to 5 mm is feasible, and rotational corrections are recommended in rectal patients to further minimise OAR irradiation.
- Open Access
- 7 December 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 68 (2) , 157-166
The effect of imaging modality (magnetic resonance imaging vs. computed tomography) and patient position (supine vs. prone) on target and organ at risk doses in partial breast irradiation
Introduction Conventionally computed tomography (CT) has been used to delineate target volumes in radiotherapy; however, magnetic resonance imaging (MRI) is being continually integrated into clinical practice; therefore, the investigation into targets derived from MRI is warranted. The purpose of this study was to evaluate the impact of imaging modality (MRI vs. CT) and patient positioning (supine vs. prone) on planning target volumes (PTVs) and organs at risk (OARs) for partial breast irradiation (PBI). Methods A retrospective data set, of 35 patients, was accessed where each patient had undergone MRI and CT imaging for tangential whole breast radiotherapy in both the supine and prone position. PTVs were defined from seroma cavity (SC) volumes delineated on each respective image, resulting in 4 PTVs per patient. PBI plans were generated with 6MV external beam radiotherapy (EBRT) using the TROG 06.02 protocol guidelines. A prescription of 38.5Gy in 10 fractions was used for all cases. The impact analysis of imaging modality and patient positioning included dose to PTVs, and OARs based on agreed criteria. Statistical analysis was conducted though Mann–Whitey U, Fisher’s exact and chi‐squared testing (P < 0.005). Results Twenty‐four patients were eligible for imaging analysis. However, positioning analysis could only be investigated on 19 of these data sets. No statistically significant difference was found in OAR doses based on imaging modality. Supine patient position resulted in lower contralateral breast dose (0.10Gy ± 0.35 vs. 0.33Gy ± 0.78, p = 0.011). Prone positioning resulted in a lower dose to ipsilateral lung volumes (10.85Gy ± 11.37 vs. 3.41Gy ± 3.93, P = <0.001). Conclusions PBI plans with PTVs derived from MRI exhibited no clinically significant differences when compared to plans created from CT in relation to plan compliance and OAR dose. Patient position requires careful consideration regardless of imaging modality chosen. Although there was no proven superiority of MRI derived target volumes, it indicates that MRI could be considered for PBI target delineation.
- 7 December 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 68 (2) , 157-166
Open AccessThe effect of imaging modality (magnetic resonance imaging vs. computed tomography) and patient position (supine vs. prone) on target and organ at risk doses in partial breast irradiation
Introduction Conventionally computed tomography (CT) has been used to delineate target volumes in radiotherapy; however, magnetic resonance imaging (MRI) is being continually integrated into clinical practice; therefore, the investigation into targets derived from MRI is warranted. The purpose of this study was to evaluate the impact of imaging modality (MRI vs. CT) and patient positioning (supine vs. prone) on planning target volumes (PTVs) and organs at risk (OARs) for partial breast irradiation (PBI). Methods A retrospective data set, of 35 patients, was accessed where each patient had undergone MRI and CT imaging for tangential whole breast radiotherapy in both the supine and prone position. PTVs were defined from seroma cavity (SC) volumes delineated on each respective image, resulting in 4 PTVs per patient. PBI plans were generated with 6MV external beam radiotherapy (EBRT) using the TROG 06.02 protocol guidelines. A prescription of 38.5Gy in 10 fractions was used for all cases. The impact analysis of imaging modality and patient positioning included dose to PTVs, and OARs based on agreed criteria. Statistical analysis was conducted though Mann–Whitey U, Fisher’s exact and chi‐squared testing (P < 0.005). Results Twenty‐four patients were eligible for imaging analysis. However, positioning analysis could only be investigated on 19 of these data sets. No statistically significant difference was found in OAR doses based on imaging modality. Supine patient position resulted in lower contralateral breast dose (0.10Gy ± 0.35 vs. 0.33Gy ± 0.78, p = 0.011). Prone positioning resulted in a lower dose to ipsilateral lung volumes (10.85Gy ± 11.37 vs. 3.41Gy ± 3.93, P = <0.001). Conclusions PBI plans with PTVs derived from MRI exhibited no clinically significant differences when compared to plans created from CT in relation to plan compliance and OAR dose. Patient position requires careful consideration regardless of imaging modality chosen. Although there was no proven superiority of MRI derived target volumes, it indicates that MRI could be considered for PBI target delineation.
- Open Access
- 1 December 2020
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 16, 58-64
Cautiously optimistic: A survey of radiation oncology professionals’ perceptions of automation in radiotherapy planning
- 1 December 2020
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 16, 58-64
Open AccessCautiously optimistic: A survey of radiation oncology professionals’ perceptions of automation in radiotherapy planning
- 9 November 2016
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 61 (3) , 394-401
Survey of image‐guided radiotherapy use in Australia
Introduction: This study aimed to evaluate the current use of imaging technologies for planning and delivery of radiotherapy (RT) in Australia.Methods: An online survey was emailed to all Australian RT centres in August 2015. The survey inquired about imaging practices during planning and treatment delivery processes. Participants were asked about the types of image‐guided RT (IGRT) technologies and the disease sites they were used for, reasons for implementation, frequency of imaging and future plans for IGRT use in their department.Results: The survey was completed by 71% of Australian RT centres. All respondents had access to computed tomography (CT) simulators and regularly co‐registered the following scans to the RT: diagnostic CT (50%), diagnostic magnetic resonance imaging (MRI) (95%), planning MRI (34%), planning positron emission tomography (PET) (26%) and diagnostic PET (97%) to aid in tumour delineation. The main reason for in‐room IGRT implementation was the use of highly conformal techniques, while the most common reason for under‐utilisation was lack of equipment capability. The most commonly used IGRT modalities were kilovoltage (kV) cone‐beam CT (CBCT) (97%), kV electronic portal image (EPI) (89%) and megavoltage (MV) EPI (75%). Overall, participants planned to increase IGRT use in planning (33%) and treatment delivery (36%).Conclusions: IGRT is widely used among Australian RT centres. On the basis of future plans of respondents, the installation of new imaging modalities is expected to increase for both planning and treatment.
- 9 November 2016
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 61 (3) , 394-401
Survey of image‐guided radiotherapy use in Australia
Introduction: This study aimed to evaluate the current use of imaging technologies for planning and delivery of radiotherapy (RT) in Australia.Methods: An online survey was emailed to all Australian RT centres in August 2015. The survey inquired about imaging practices during planning and treatment delivery processes. Participants were asked about the types of image‐guided RT (IGRT) technologies and the disease sites they were used for, reasons for implementation, frequency of imaging and future plans for IGRT use in their department.Results: The survey was completed by 71% of Australian RT centres. All respondents had access to computed tomography (CT) simulators and regularly co‐registered the following scans to the RT: diagnostic CT (50%), diagnostic magnetic resonance imaging (MRI) (95%), planning MRI (34%), planning positron emission tomography (PET) (26%) and diagnostic PET (97%) to aid in tumour delineation. The main reason for in‐room IGRT implementation was the use of highly conformal techniques, while the most common reason for under‐utilisation was lack of equipment capability. The most commonly used IGRT modalities were kilovoltage (kV) cone‐beam CT (CBCT) (97%), kV electronic portal image (EPI) (89%) and megavoltage (MV) EPI (75%). Overall, participants planned to increase IGRT use in planning (33%) and treatment delivery (36%).Conclusions: IGRT is widely used among Australian RT centres. On the basis of future plans of respondents, the installation of new imaging modalities is expected to increase for both planning and treatment.
- 1 November 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 96 (4) , 905-912
Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions
- 1 November 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 96 (4) , 905-912
Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions
- Open Access
- 8 September 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (5) , 7-19
MRI geometric distortion: Impact on tangential whole‐breast IMRT
The purpose of this study was to determine the impact of magnetic resonance imaging (MRI) geometric distortions when using MRI for target delineation and planning for whole-breast, intensity-modulated radiotherapy (IMRT). Residual system distortions and combined systematic and patient-induced distortions are considered. This retrospective study investigated 18 patients who underwent whole-breast external beam radiotherapy, where both CT and MRIs were acquired for treatment planning. Distortion phantoms were imaged on two MRI systems, dedicated to radiotherapy planning (a wide, closed-bore 3T and an open-bore 1T). Patient scans were acquired on the 3T system. To simulate MRI-based planning, distortion maps representing residual system distortions were generated via deformable registration between phantom CT and MRIs. Patient CT images and structures were altered to match the residual system distortion measured by the phantoms on each scanner. The patient CTs were also registered to the corresponding patient MRI scans, to assess patient and residual system effects. Tangential IMRT plans were generated and optimized on each resulting CT dataset, then propagated to the original patient CT space. The resulting dose distributions were then evaluated with respect to the standard clinically acceptable DVH and visual assessment criteria. Maximum residual systematic distortion was measured to be 7.9 mm ( ) and 11.9 mm ( ) for the 3T and 1T scanners, respectively, which did not result in clinically unacceptable plans. Eight of the plans accounting for patient and systematic distortions were deemed clinically unacceptable when assessed on the original CT. For these plans, the mean difference in PTV (volume receiving 95% prescription dose) was and for right- and left-sided patients, respectively. Residual system distortions alone had minimal impact on the dosimetry for the two scanners investigated. The combination of MRI systematic and patient-related distortions can result in unacceptable dosimetry for whole-breast IMRT, a potential issue when considering MRI-only radiotherapy treatment planning. PACS number(s): 87.61.-c, 87.57.cp, 87.57.nj, 87.55.D-- 8 September 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (5) , 7-19
Open AccessMRI geometric distortion: Impact on tangential whole‐breast IMRT
The purpose of this study was to determine the impact of magnetic resonance imaging (MRI) geometric distortions when using MRI for target delineation and planning for whole-breast, intensity-modulated radiotherapy (IMRT). Residual system distortions and combined systematic and patient-induced distortions are considered. This retrospective study investigated 18 patients who underwent whole-breast external beam radiotherapy, where both CT and MRIs were acquired for treatment planning. Distortion phantoms were imaged on two MRI systems, dedicated to radiotherapy planning (a wide, closed-bore 3T and an open-bore 1T). Patient scans were acquired on the 3T system. To simulate MRI-based planning, distortion maps representing residual system distortions were generated via deformable registration between phantom CT and MRIs. Patient CT images and structures were altered to match the residual system distortion measured by the phantoms on each scanner. The patient CTs were also registered to the corresponding patient MRI scans, to assess patient and residual system effects. Tangential IMRT plans were generated and optimized on each resulting CT dataset, then propagated to the original patient CT space. The resulting dose distributions were then evaluated with respect to the standard clinically acceptable DVH and visual assessment criteria. Maximum residual systematic distortion was measured to be 7.9 mm ( ) and 11.9 mm ( ) for the 3T and 1T scanners, respectively, which did not result in clinically unacceptable plans. Eight of the plans accounting for patient and systematic distortions were deemed clinically unacceptable when assessed on the original CT. For these plans, the mean difference in PTV (volume receiving 95% prescription dose) was and for right- and left-sided patients, respectively. Residual system distortions alone had minimal impact on the dosimetry for the two scanners investigated. The combination of MRI systematic and patient-related distortions can result in unacceptable dosimetry for whole-breast IMRT, a potential issue when considering MRI-only radiotherapy treatment planning. PACS number(s): 87.61.-c, 87.57.cp, 87.57.nj, 87.55.D- - 13 August 2015
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 59 (6) , 736-742
Australian survey on current practices for breast radiotherapy
Introduction: Detailed, published surveys specific to Australian breast radiotherapy practice were last conducted in 2002. More recent international surveys specific to breast radiotherapy practice include a European survey conducted in 2008/2009 and a Spanish survey conducted in 2009. Radiotherapy techniques continue to evolve, and the utilisation of new techniques, such as intensity‐modulated radiation therapy (IMRT), is increasing. This survey aimed to determine current breast radiotherapy practices across Australia.Method: An online survey was completed by 50 of the 69 Australian radiation therapy treatment centres.Results: Supine tangential beam whole breast irradiation remains the standard of care for breast radiotherapy in Australia. A growing number of institutions are exploring prone positioning and IMRT utilisation. This survey demonstrated a wide variation in the benchmarks used to limit and report organ at risk doses, prescribed dose regimen, and post‐mastectomy bolus practices. This survey also indicated, when compared with international literature, that there may be less interest in or uptake of external beam partial breast irradiation, prone positioning, simultaneous integrated boost and breath hold techniques. These are areas where further review and research may be warranted to ensure Australian patients are receiving the best care possible based on the best evidence available.Conclusion: This survey provides insight into the current radiotherapy practice for breast cancer in Australia.
- 13 August 2015
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 59 (6) , 736-742
Australian survey on current practices for breast radiotherapy
Introduction: Detailed, published surveys specific to Australian breast radiotherapy practice were last conducted in 2002. More recent international surveys specific to breast radiotherapy practice include a European survey conducted in 2008/2009 and a Spanish survey conducted in 2009. Radiotherapy techniques continue to evolve, and the utilisation of new techniques, such as intensity‐modulated radiation therapy (IMRT), is increasing. This survey aimed to determine current breast radiotherapy practices across Australia.Method: An online survey was completed by 50 of the 69 Australian radiation therapy treatment centres.Results: Supine tangential beam whole breast irradiation remains the standard of care for breast radiotherapy in Australia. A growing number of institutions are exploring prone positioning and IMRT utilisation. This survey demonstrated a wide variation in the benchmarks used to limit and report organ at risk doses, prescribed dose regimen, and post‐mastectomy bolus practices. This survey also indicated, when compared with international literature, that there may be less interest in or uptake of external beam partial breast irradiation, prone positioning, simultaneous integrated boost and breath hold techniques. These are areas where further review and research may be warranted to ensure Australian patients are receiving the best care possible based on the best evidence available.Conclusion: This survey provides insight into the current radiotherapy practice for breast cancer in Australia.