Zied Kaabia
Research Subjects
Zied Kaabia has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Loup
GIE LCH, Laboratoire des Courses Hippiques Verrières‐le‐Buisson France
2 shared publications - Ludovic Bailly‐Chouriberry
GIE LCH, Laboratoire des Courses Hippiques Verrières‐le‐Buisson France
2 shared publications - Marie‐Agnès Popot
GIE LCH, Laboratoire des Courses Hippiques Verrières‐le‐Buisson France
2 shared publications - Patrice Garcia
GIE LCH, Laboratoire des Courses Hippiques Verrières‐le‐Buisson France
2 shared publications - Vivian Delcourt
GIE LCH, Laboratoire des Courses Hippiques Verrières‐le‐Buisson France
2 shared publications Anne‐Lise Royer
ONIRIS, INRAE, LABERCA Nantes France
1 shared publication
Latest Publications
- 9 January 2022
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (5) , 864-878
From a non‐targeted metabolomics approach to a targeted biomarkers strategy to highlight testosterone abuse in equine. Illustration of a methodological transfer between platforms and laboratories
In order to overcome the challenge associated with the screening of Anabolic‐Androgenic Steroids abuses in animal competitions, a non‐targeted liquid chromatography coupled to high resolution mass spectrometry based metabolomics approach was implemented on equine urine samples to highlight potential biomarkers associated with the administration of such compounds, using testosterone esters as model steroids. A statistical model relying on four potential biomarkers intensity could be defined to predict the status of the samples. With a routine application perspective, the monitoring of the highlighted potential biomarkers was first transferred into high‐throughput liquid chromatography‐selected reaction monitoring (LC‐SRM). The model's performances and robustness of the approach were preserved and providing a first demonstration of metabolomics‐based biomarkers integration within a targeted workflow using common benchtop MS instrumentation. In addition, with a view to the widespread implementation of such biomarker‐based tools, we have transferred the method to a second laboratory with similar instrumentation. This proof of concept allows the development and application of biomarker‐based strategies to meet current doping control needs.
- 9 January 2022
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (5) , 864-878
From a non‐targeted metabolomics approach to a targeted biomarkers strategy to highlight testosterone abuse in equine. Illustration of a methodological transfer between platforms and laboratories
In order to overcome the challenge associated with the screening of Anabolic‐Androgenic Steroids abuses in animal competitions, a non‐targeted liquid chromatography coupled to high resolution mass spectrometry based metabolomics approach was implemented on equine urine samples to highlight potential biomarkers associated with the administration of such compounds, using testosterone esters as model steroids. A statistical model relying on four potential biomarkers intensity could be defined to predict the status of the samples. With a routine application perspective, the monitoring of the highlighted potential biomarkers was first transferred into high‐throughput liquid chromatography‐selected reaction monitoring (LC‐SRM). The model's performances and robustness of the approach were preserved and providing a first demonstration of metabolomics‐based biomarkers integration within a targeted workflow using common benchtop MS instrumentation. In addition, with a view to the widespread implementation of such biomarker‐based tools, we have transferred the method to a second laboratory with similar instrumentation. This proof of concept allows the development and application of biomarker‐based strategies to meet current doping control needs.
- 11 October 2021
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (2) , 252-261
LC‐HRMS/MS study of the prodrug ciclesonide and its active metabolite desisobutyryl‐ciclesonide in plasma after an inhalative administration to horses for doping control purposes
Ciclesonide (CIC) is the first inhaled highly potent corticosteroid which does not cause any cortisol suppression. It has been developed for the treatment of asthma in human and more recently in equine. CIC is the active compound of Aservo® EquiHaler® (Boehringer Ingelheim Vetmedica GmbH), the pre-filled inhaler generating a medicated mist based on Soft MistTM technology. This prodrug is rapidly converted to desisobutyryl-ciclesonide (des-CIC), the main pharmacologically active compound. Due to its anti-inflammatory properties CIC is prohibited for use in horse competitions. To set up an appropriate control, the determination of detection times and screening limits are required. Therefore, a highly sensitive analytical method based on Supported Liquid Extraction (SLE) combined with Liquid Chromatography - High Resolution tandem Mass Spectrometry (LC-HRMS/MS) was developed to detect CIC and its active metabolite des-CIC in plasma. The lower limit of detection of CIC and des-CIC was approximately 1 pg/mL in plasma. After a pilot study conducted on a single horse at the recommended dose (8 actuations twice daily corresponding to 5.5 mg/day for the first five days, followed by 12 actuations once daily corresponding to 4.1 mg/day in the last five days), the same protocol was applied in the main study using six-horses. In all horses, CIC and des-CIC levels were less than 5 and 10 pg/mL, respectively, at 36 hours after the end of the administration. The outcome of this risk assessment study should be useful to draw any recommendations for horse competitions.
- 11 October 2021
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (2) , 252-261
LC‐HRMS/MS study of the prodrug ciclesonide and its active metabolite desisobutyryl‐ciclesonide in plasma after an inhalative administration to horses for doping control purposes
Ciclesonide (CIC) is the first inhaled highly potent corticosteroid which does not cause any cortisol suppression. It has been developed for the treatment of asthma in human and more recently in equine. CIC is the active compound of Aservo® EquiHaler® (Boehringer Ingelheim Vetmedica GmbH), the pre-filled inhaler generating a medicated mist based on Soft MistTM technology. This prodrug is rapidly converted to desisobutyryl-ciclesonide (des-CIC), the main pharmacologically active compound. Due to its anti-inflammatory properties CIC is prohibited for use in horse competitions. To set up an appropriate control, the determination of detection times and screening limits are required. Therefore, a highly sensitive analytical method based on Supported Liquid Extraction (SLE) combined with Liquid Chromatography - High Resolution tandem Mass Spectrometry (LC-HRMS/MS) was developed to detect CIC and its active metabolite des-CIC in plasma. The lower limit of detection of CIC and des-CIC was approximately 1 pg/mL in plasma. After a pilot study conducted on a single horse at the recommended dose (8 actuations twice daily corresponding to 5.5 mg/day for the first five days, followed by 12 actuations once daily corresponding to 4.1 mg/day in the last five days), the same protocol was applied in the main study using six-horses. In all horses, CIC and des-CIC levels were less than 5 and 10 pg/mL, respectively, at 36 hours after the end of the administration. The outcome of this risk assessment study should be useful to draw any recommendations for horse competitions.
- 31 January 2012
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 23 (5) , 850-857
Using Electron Induced Dissociation (EID) on an LC Time-Scale to Characterize a Mixture of Analogous Small Organic Molecules
LC ESI FTICR MS of a sample of cediranib identified this pharmaceutical target molecule plus an additional 10 compounds of interest, all of which were less than 10% total ion current (TIC) peak intensity relative to cediranib. LC FTICR tandem mass spectrometry using electron induced dissociation (EID) has been achieved and has proven to be the best way to generate useful product ion information for all of these singly protonated molecules. Cediranib [M + H]+ fragmented by EID to give 29 product ions whereas QTOF-CID generated only one very intense product ion, and linear ion trap-CID, which generated 10 product ions, but all with poor S/N. Twenty-six of the EID product ions were unique to this fragmentation technique alone. By considering the complementary LC-EID and LC-CID data together, all 10 unknown compounds were structurally characterized and proven to be analogous to cediranib. Of particular importance, EID produced unique product ion information for one of the low level cediranib analogues that enabled full characterization of the molecule such that the presence of an extra propylpyrrolidine group was discovered and proven to be located on the pyrrolidine ring of cediranib, solving an analytical problem that could not be solved by collision induced dissociation (CID). Thus, it has been demonstrated that EID is in harmony with the chromatography duty-cycle and the dynamic concentration range of synthetic compounds containing trace impurities, providing crucial analytical information that cannot be obtained by more traditional methodologies.
- 31 January 2012
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 23 (5) , 850-857
Using Electron Induced Dissociation (EID) on an LC Time-Scale to Characterize a Mixture of Analogous Small Organic Molecules
LC ESI FTICR MS of a sample of cediranib identified this pharmaceutical target molecule plus an additional 10 compounds of interest, all of which were less than 10% total ion current (TIC) peak intensity relative to cediranib. LC FTICR tandem mass spectrometry using electron induced dissociation (EID) has been achieved and has proven to be the best way to generate useful product ion information for all of these singly protonated molecules. Cediranib [M + H]+ fragmented by EID to give 29 product ions whereas QTOF-CID generated only one very intense product ion, and linear ion trap-CID, which generated 10 product ions, but all with poor S/N. Twenty-six of the EID product ions were unique to this fragmentation technique alone. By considering the complementary LC-EID and LC-CID data together, all 10 unknown compounds were structurally characterized and proven to be analogous to cediranib. Of particular importance, EID produced unique product ion information for one of the low level cediranib analogues that enabled full characterization of the molecule such that the presence of an extra propylpyrrolidine group was discovered and proven to be located on the pyrrolidine ring of cediranib, solving an analytical problem that could not be solved by collision induced dissociation (CID). Thus, it has been demonstrated that EID is in harmony with the chromatography duty-cycle and the dynamic concentration range of synthetic compounds containing trace impurities, providing crucial analytical information that cannot be obtained by more traditional methodologies.