Caroline Lafond
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Caroline Lafond has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Joel Castelli
University of Rennes, CLCC Eugène Marquis, Inserm, LTSI–UMR 1099, Rennes, France
2 shared publications Renaud de Crevoisier
Univ Rennes, CLCC Eugène Marquis, INSERM, LTSI - UMR 1099, F-35000 Rennes, France
2 shared publicationsA. Simon
Inserm U1099, 35000 Rennes, France; LTSI, université Rennes-1, 35000 Rennes, France
1 shared publicationAnne Devillers
Centre Eugène Marquis Rennes France
1 shared publicationAnthony Vela
Centre François Baclesse, 14000 Caen, France
1 shared publication- Antoine Simon
LTSI, Universite de Rennes 1, Bât. 22, Campus de Beaulieu, Rennes, 35065, FRANCE
1 shared publication
Latest Publications
- Open Access
- 9 March 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111475
Longitudinal voxel-based analysis identifies a bladder neck subregion predicting genitourinary toxicity after prostate cancer reirradiation
- 9 March 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111475
Open AccessLongitudinal voxel-based analysis identifies a bladder neck subregion predicting genitourinary toxicity after prostate cancer reirradiation
- 8 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105063
Dose escalation in pediatric pelvic Ewing’s Sarcoma: Insights from a national treatment planning exercise
- 8 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105063
Dose escalation in pediatric pelvic Ewing’s Sarcoma: Insights from a national treatment planning exercise
- 27 April 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (5) , 664-670
DEMAT: A multi-institutional dosimetry audit of rotational and static intensity-modulated radiotherapy
- 27 April 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (5) , 664-670
DEMAT: A multi-institutional dosimetry audit of rotational and static intensity-modulated radiotherapy
- 1 October 2015
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 19 (6-7) , 450-457
Radiothérapie adaptative en routine ? État de l’art : point de vue du physicien médical
- 1 October 2015
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 19 (6-7) , 450-457
Radiothérapie adaptative en routine ? État de l’art : point de vue du physicien médical
- 1 February 2014
- Published by Elsevier in Physica Medica
- Vol. 30 (1) , 2-9
Comparison between two treatment planning systems for volumetric modulated arc therapy optimization for prostate cancer
- 1 February 2014
- Published by Elsevier in Physica Medica
- Vol. 30 (1) , 2-9
Comparison between two treatment planning systems for volumetric modulated arc therapy optimization for prostate cancer
- Open Access
- 8 November 2013
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 14 (6) , 40-52
Impact of MLC leaf width on volumetric‐modulated arc therapy planning for head and neck cancers
This dosimetric study investigated the impact of multileaf collimators (MLC) leaf width in volumetric-modulated arc therapy (VMAT) for head and neck cancers (HNC), either with a “standard” simultaneously integrated boost technique (S-SIB) or with a “dose painting” SIB technique (DP-SIB). HNC patients were planned either with an S-SIB comprising three dose levels, from 56 to 70 Gy (16 patients), or with a DP-SIB comprising five dose levels, from 56 to 84 Gy (8 patients), in 35 fractions. Two VMAT plans were calculated for each SIB technique using two Elekta MLCs: MLCi2 with 10 mm leaf width and Beam Modulator (BM) with 4 mm leaf width. Dose distributions were evaluated by comparing doses on PTVs, main OARs, and healthy tissue, and by comparing conformation indexes. Treatment efficiencies were evaluated by comparing the number of monitor units and the number of needed arcs. Comparisons of the two MLCs depending on the two SIB techniques showed: i) Regarding PTVs: Dmean and D2% on lower doses PTV decreased respectively by 0.5 Gy and 0.9 Gy with BM than with MLCi2 for S-SIB; no significant difference was found for DP-SIB; ii) Regarding OARs: for spinal cord and brainstem, D2% decreased respectively by 1.2 Gy and 4.2 Gy with BM than with MLCi2 for S-SIB; for controlateral parotid, D50% decreased by 1.5 Gy- 8 November 2013
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 14 (6) , 40-52
Open AccessImpact of MLC leaf width on volumetric‐modulated arc therapy planning for head and neck cancers
This dosimetric study investigated the impact of multileaf collimators (MLC) leaf width in volumetric-modulated arc therapy (VMAT) for head and neck cancers (HNC), either with a “standard” simultaneously integrated boost technique (S-SIB) or with a “dose painting” SIB technique (DP-SIB). HNC patients were planned either with an S-SIB comprising three dose levels, from 56 to 70 Gy (16 patients), or with a DP-SIB comprising five dose levels, from 56 to 84 Gy (8 patients), in 35 fractions. Two VMAT plans were calculated for each SIB technique using two Elekta MLCs: MLCi2 with 10 mm leaf width and Beam Modulator (BM) with 4 mm leaf width. Dose distributions were evaluated by comparing doses on PTVs, main OARs, and healthy tissue, and by comparing conformation indexes. Treatment efficiencies were evaluated by comparing the number of monitor units and the number of needed arcs. Comparisons of the two MLCs depending on the two SIB techniques showed: i) Regarding PTVs: Dmean and D2% on lower doses PTV decreased respectively by 0.5 Gy and 0.9 Gy with BM than with MLCi2 for S-SIB; no significant difference was found for DP-SIB; ii) Regarding OARs: for spinal cord and brainstem, D2% decreased respectively by 1.2 Gy and 4.2 Gy with BM than with MLCi2 for S-SIB; for controlateral parotid, D50% decreased by 1.5 GyOpen Access- 30 May 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 132
Salivary gland-sparing other than parotid-sparing in definitive head-and-neck intensity-modulated radiotherapy does not seem to jeopardize local control
The objective was to analyze locoregional (LR) failure patterns in patients with head-and-neck cancer (HNC) treated using intensity-modulated radiotherapy (IMRT) with whole salivary gland-sparing: parotid (PG), submandibular (SMG), and accessory salivary glands represented by the oral cavity (OC).
- 30 May 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 132
Open AccessSalivary gland-sparing other than parotid-sparing in definitive head-and-neck intensity-modulated radiotherapy does not seem to jeopardize local control
The objective was to analyze locoregional (LR) failure patterns in patients with head-and-neck cancer (HNC) treated using intensity-modulated radiotherapy (IMRT) with whole salivary gland-sparing: parotid (PG), submandibular (SMG), and accessory salivary glands represented by the oral cavity (OC).