Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Salman Al Farisi has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Zoonoses research in veterinary epidemiology from 1956 to 2024: A bibliometric and network analysis of global trends, research collaboration, and the shift toward molecular and genomic approaches

    by Imron Rosyadi, Ahmad Kusumaatmaja, Wahyu Aristyaning Putri, Woro Anindito Sri Tunjung, Hanif Khoirudin, Annisa Salma Rosy Audina, Muhammad Salman Al Farisi

    Background and Aim: Zoonotic diseases pose substantial threats to global public health, emphasizing the importance of veterinary epidemiology in surveillance and prevention. However, the growth, geographic distribution, collaborative networks, and thematic evolution of zoonoses research remain insufficiently characterized. This study aimed to map the bibliometric landscape of zoonoses research in veterinary epidemiology from 1956 to 2024, with particular emphasis on the transition toward molecular and genomic approaches. Materials and Methods: A bibliometric analysis was conducted using 1,867 Scopus-indexed documents published between 1956 and 2024 and retrieved on February 14, 2026. Publication trends, citation performance, geographic contributions, institutional productivity, and international collaboration were evaluated. Co-authorship and keyword co-occurrence networks were constructed using VOSviewer with association-strength normalization. Temporal overlay visualization and comparative keyword-frequency analysis were used to identify emerging research themes and quantify changes in molecular, genomic, and serological research emphasis. Results: Annual publication output increased at a compound annual growth rate of 14.4% during 2000–2024 (R² = 0.88), reaching 329 documents in 2024. Research articles accounted for 77.8% of publications, while English-language documents represented 94.2%. The United States contributed the most publications (400; 21.4%), followed by Brazil (196; 10.5%) and the United Kingdom (193; 10.3%). Internationally co-authored publications represented 38.2% of records with usable affiliation data. The corpus accumulated 54,734 citations, with an h-index of 109. Keyword network analysis identified five thematic clusters spanning epidemiology, public health, serological surveillance, molecular genetics, and companion-animal research. The proportion of publications containing molecular or genomic keywords increased significantly from 50.5% in 2005–2014 to 70.2% in 2015–2024 (p < 0.001), indicating a measurable shift in research emphasis. Conclusion: Zoonoses research in veterinary epidemiology has expanded substantially, accompanied by increasing molecular and genomic emphasis and growing international collaboration. Nevertheless, geographic disparities persist. Strengthening genomic surveillance capacity, interdisciplinary One Health research, and equitable partnerships with endemic regions may improve future zoonotic disease surveillance and control. These findings reflect bibliometric trends rather than verified changes in laboratory practices. Keywords: bibliometric analysis, genomic surveillance, international research collaboration, molecular epidemiology, One Health, research trends, veterinary epidemiology, zoonotic diseases.

  • Open Access

    Global research trends and emerging frontiers of Clitoria ternatea in veterinary and animal sciences: A bibliometric analysis (1973–2026)

    by Ahmad Kusumaatmaja, Yesi Deviana, Wahyu Aristyaning Putri, Hanif Khoirudin, Annisa Salma Rosy Audina, Muhammad Salman Al Farisi, Imron Rosyadi

    Background and Aim: Clitoria ternatea L. (butterfly pea) has attracted increasing research interest in veterinary and animal sciences because of its applications in livestock nutrition, animal-model pharmacology, and intelligent packaging for animal-origin foods. However, the geographical distribution, collaborative structure, thematic organization, and evolution of this research remain insufficiently characterized. This study aimed to map global publication trends, leading contributors, research networks, and emerging scientific frontiers of C. ternatea in veterinary and animal sciences. Materials and Methods: A bibliometric analysis was conducted using Scopus records retrieved on March 18, 2026. Publications addressing C. ternatea in veterinary and animal sciences were identified through predefined search terms and eligibility criteria. Of the 1,466 retrieved records, we excluded 1,148 after screening, leaving 318 publications from 1973 to March 2026. Publication trends, citation indicators, geographical contributions, institutional productivity, international collaboration, and keyword co-occurrence were analyzed using Microsoft Excel, Python, and VOSviewer. Thematic communities were identified through weighted modularity-based network analysis, and temporal keyword mapping was used to characterize changing research priorities. Results: Annual publication output increased by approximately 14% during 2000–2025 (R² = 0.88), reaching 45 publications in 2024. Of the 318 publications, 170 (53.5%) appeared during 2021–March 2026. The publications accumulated 4,991 citations, averaging 15.7 citations per document, with an h-index of 34. India (91 publications) and Indonesia (66) were the leading contributors, followed by Australia (32), Thailand (26), Brazil (25), and Malaysia (25). International collaboration accounted for only 19.8% of publications. Analysis of 112 keywords identified five thematic clusters (modularity Q = 0.33): animal-model pharmacology and toxicology, anthocyanin-based intelligent packaging, tropical forage and ruminant nutrition, phytochemistry and bioactive characterization, and antidiabetic and metabolic animal models. Temporal mapping indicated increasing emphasis on intelligent packaging during 2020–2024. Conclusion: Research on C. ternatea is expanding but remains geographically concentrated and internationally fragmented. The identified research fronts highlight opportunities for coordinated investigations into livestock nutrition, animal-origin food quality, and veterinary applications. Broader collaboration and controlled translational studies are needed to strengthen veterinary and One Health relevance. Keywords: animal nutrition, anthocyanins, bibliometric analysis, Clitoria ternatea, intelligent food packaging, research trends, tropical forage, veterinary science.

  • Single-step laser patterning and thinning of biocompatible MEMS flow sensor

    by Mohammad Nizar Mohamed Zukri, Muhammad Salman Al Farisi, Yoshihiro Hasegawa, Mitsuhiro Shikida


  • Open Access

    Single-step laser patterning and thinning of biocompatible MEMS flow sensor

    by Mohammad Nizar Mohamed Zukri, Muhammad Salman Al Farisi, Yoshihiro Hasegawa, Mitsuhiro Shikida

    Micro-electro mechanical systems (MEMS) thermal flow sensors are increasingly used for compact, low-power flow monitoring in biomedical applications. However, silicon-based method for sensor fabrication is limited by high cost, rigidity, and multi-step cleanroom processes. This study presents a single-step fiber laser micromachining method for fabricating biocompatible, free-standing MEMS thermal flow sensors from ultrathin titanium foil. The process combines patterning and localized thinning in single-step process, with titanium serving as resistive sensing element. A dual-matrix optimization approach consisting of a Threshold Mapping Matrix (TMM) and Energy Density Matrix (EDM) was used to determine optimized parameters without repeated trial-and-error. For localized thinning, sequential R-T scans with cooling intervals reduced redeposition from the Gaussian beam profile and produced uniform thickness reduction from 50 μm to 20--30 μm. The fabricated sensors were evaluated through thermal coefficient resistance (TCR) measurement, Infrared (IR) thermography, and airflow tests under steady and cyclic conditions controlled by artificial ventilation system. The fabricated devices showed a stable TCR of 3278 ppm °C$^{-1}$, a linear relationship calibration curve between velocity and resistance with $R^2$=0.986 and a 54% improvement in thermal response was achieved with the free-standing structure design compared to substrate-fixed designs. This fabrication approach removes the need for photolithography, wet/dry etching, and wafer bonding, enabling faster and lower-cost production of flexible, biocompatible flow sensors. The method can be applied to other MEMS devices that require compact size, flexibility, localized thinning and free-standing structures.

  • Open Access

    Response Time Suppression in Flexible MEMS Thermal Sensor by Backside Laser Ablation

    by Muhammad Salman Al Farisi, Yoshihiro Hasegawa, Mitsuhiro Shikida

    Thermal sensing is a promising mechanism for flexible micro-electro mechanical systems (MEMS) physical sensors, owing to its lack of moving or resonating parts. However, achieving fast response times has been hindered by the thermal mass surrounding the sensing structure. Unlike rigid MEMS devices, flexible sensors cannot easily incorporate free-standing structures due to their low mechanical rigidity. Conventional methods to reduce thermal mass, such as thinning the entire substrate, are often limited by difficulties in sensor handling and integration. To address this challenge, here we propose a localized backside laser ablation technique that selectively removes substrate material only beneath the sensing region. By employing a pulsed ultraviolet (UV) laser, this method reduces the thermal mass while preserving the structural integrity of the overall device. The resulting flexible thermal sensor, fabricated on a polyimide film, demonstrated a dramatic improvement in time response, achieving over 90% reduction compared to unprocessed counterparts. Experimental airflow sensing further validated the technique's effectiveness, including successful operation under 4 Hz reciprocating flow conditions.

  • Response Time Suppression in Flexible MEMS Thermal Sensor by Backside Laser Ablation

    by Muhammad Salman Al Farisi, Yoshihiro Hasegawa, Mitsuhiro Shikida

    Thermal sensing is a promising mechanism for flexible micro-electro mechanical systems (MEMS) physical sensors, owing to its lack of moving or resonating parts. However, achieving fast response times has been hindered by the thermal mass surrounding the sensing structure. Unlike rigid MEMS devices, flexible sensors cannot easily incorporate free-standing structures due to their low mechanical rigidity. Conventional methods to reduce thermal mass, such as thinning the entire substrate, are often limited by difficulties in sensor handling and integration. To address this challenge, here we propose a localized backside laser ablation technique that selectively removes substrate material only beneath the sensing region. By employing a pulsed ultraviolet (UV) laser, this method reduces the thermal mass while preserving the structural integrity of the overall device. The resulting flexible thermal sensor, fabricated on a polyimide film, demonstrated a dramatic improvement in time response, achieving over 90% reduction compared to unprocessed counterparts. Experimental airflow sensing further validated the technique’s effectiveness, including successful operation under 4 Hz reciprocating flow conditions.

  • Open Access

    Laser fabrication of Ti stent and facile MEMS flow sensor integration for implantable respiration monitoring

    by Muhammad Salman Al Farisi, Takuya Kawata, Yoshihiro Hasegawa, Mohammad Nizar Mohamed Zukri, Miyoko Matsushima, Tsutomu Kawabe, Mitsuhiro Shikida

    Animal experiments play a vital role in drug discovery and development by providing essential data on a drug's efficacy, safety, and physiological effects before advancing to human clinical trials. In this study, we propose a stent-based flow sensor designed to measure airflow in the airways of laboratory animals. The stent was fabricated from biocompatible Ti using a combination of fiber laser digital processing and an origami-inspired folding technique. The sensing structure was developed through standard micro-electromechanical systems (MEMS) microfabrication technology. To integrate the sensing structure with the metallic stent, a facile insertion process was employed, where the sensor film was positioned at the stent's center using its natural buckling mechanism. Once fabricated, the stent implant was expanded and installed within an airway-mimicking tube to validate its functionality. A proof-of-concept trial using an artificial ventilator successfully demonstrated real-time respiration monitoring, confirming the feasibility of the proposed system for airflow measurement in preclinical studies. This stent-based sensor offers a promising approach for enhancing respiratory assessments in laboratory animals, potentially improving the accuracy of drug evaluations and respiratory disease research.

  • Laser fabrication of Ti stent and facile MEMS flow sensor integration for implantable respiration monitoring

    by Muhammad Salman Al Farisi, Takuya Kawata, Yoshihiro Hasegawa, Mohammad Nizar Mohamed Zukri, Miyoko Matsushima, Tsutomu Kawabe, Mitsuhiro Shikida


  • Open Access

    Slip-Joint Adaptor Enabling Respiratory Monitoring in Tracheal Intubation Tube

    by Ayaka Sueyoshi, Muhammad Salman Al Farisi, Yoshihiro Hasegawa, Miyoko Matsushima, Tsutomu Kawabe, Mitsuhiro Shikida

    Endotracheal intubation is frequently performed on critically ill patients or those under general anesthesia, but it carries risks of incorrect insertion into the esophagus or premature removal. To address these concerns, we propose an adaptor for tracheal intubation tube with integrated respiration monitoring functionality, enabled by a MEMS airflow sensor packaged in a 3D-printed housing. The adaptor shared the same dimensions as the conventional slip-joint, ensuring seamless compatibility with standard intubation tubes. Basic characteristics measurement indicated a sufficient performance for human respiration monitoring. Feasibility tests using an artificial ventilator to simulate breathing demonstrated the system's effectiveness. Further proof of concept via animal experiments also demonstrated successful respiration monitoring using the proposed system. The proposed device has a potential to enhance the safety and precision of endotracheal intubation by offering real-time airflow monitoring, reducing the risk of misplacement or premature extraction.

  • Open Access

    Pneumatic Tactile Sensor Probe with Variable Sensitivity for Palpation during Catheterization

    by Muhammad Salman Al Farisi, Kazumi Tsuji, Yoshihiro Hasegawa, Miyoko Matsushima, Tsutomu Kawabe, Mitsuhiro Shikida

    Palpation technologies in teleoperated catheterization are essential for remotely assessing tissue characteristics such as stiffness and elasticity, which are critical for identifying pathways in cardiovascular or pulmonary system, as well as to detect abnormalities like tumors. In this study, we present the development of a tactile sensor probe designed to support catheterization procedures. The sensor utilizes a pneumatic sensing mechanism, with its deformable tip fabricated from polydimethylsiloxane (PDMS) elastomer for biocompatibility and flexibility. Tip deformation is transmitted to a remotely located pressure sensor through a dual-fluid system using incompressible water and compressible air to relay force information. This configuration enables spatial separation between the sensing tip and the detection electronics, enhancing safety and compatibility in medical environments. Sensitivity of the system was tuned by adjusting the air gap height, and experimental results closely matched theoretical models. A reliable correlation was observed between sensor output, tip deformation, and applied normal force, confirming the sensor's capability for quantitative tactile feedback. These results demonstrate the potential of the proposed sensor for enhancing palpation in catheter-based, minimally invasive procedures.