Andreu Badal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andreu Badal has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Aldo Badano
Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration Silver Spring, Maryland, USA
5 shared publications - Nicholas Petrick
U.S. Food and Drug Administration
3 shared publications - Andrey Makeev
US Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Diagnostics, Imaging and Software Reliability, Silver Spring, Maryland, United States
2 shared publications - Bahaa Ghammraoui
Division of Imaging, Diagnostics, and Software Reliability, Office of Science and Engineering Labs, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
2 shared publications Berkman Sahiner
U.S. Food and Drug Administration (United States)
2 shared publications- Diksha Sharma
A. C. Joshi Library, Panjab University, Chandigarh, India
2 shared publications
Latest Publications
- 3 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-17
Hybrid simulation of breast CT for assessing microcalcification detectability
PurposeVirtual imaging trials (VITs) are of interest for regulatory evaluation because they enable faster and more cost-effective evaluation of new imaging technologies than patient clinical trials. Our purpose is to develop a hybrid VIT methodology for breast computed tomography (CT) applications and use it to investigate microcalcification detectability.ApproachRay tracing was used to generate projection images of clusters of five microcalcifications which varied in diameter, chemical composition, and density. These simulated projection images were added to patient projection images acquired with the fourth-generation breast CT scanner from UC Davis (Doheny) and reconstructed using the Feldkamp filtered backprojection algorithm with varying apodization kernels. Volumes of interest and maximum intensity projections were extracted from the reconstructed volumes. Human observers (HOs) and deep learning model observers (DLMOs) were used to detect calcification clusters, and receiver operating characteristic curve analysis was used to analyze detection performance.ResultsDLMO detected 0.18-mm type I calcifications with AUC = 0.80 and 0.21 mm calcifications with AUC=0.99. HO performance was inferior to deep learning model observer performance, but both HO and DLMO detected 0.21-mm type I calcifications with AUC>0.90 and 0.24-mm type I calcifications with near-perfect performance. Microcalcification clusters embedded in adipose tissue were more conspicuous than clusters embedded in fibroglandular tissue. There was superior detection performance for clusters located anteriorly within the breast compared with clusters located posteriorly within the breast.ConclusionsA hybrid approach for virtual imaging trials shows promise for the assessment of imaging systems across a broad range of parameters.
- 3 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-17
Hybrid simulation of breast CT for assessing microcalcification detectability
PurposeVirtual imaging trials (VITs) are of interest for regulatory evaluation because they enable faster and more cost-effective evaluation of new imaging technologies than patient clinical trials. Our purpose is to develop a hybrid VIT methodology for breast computed tomography (CT) applications and use it to investigate microcalcification detectability.ApproachRay tracing was used to generate projection images of clusters of five microcalcifications which varied in diameter, chemical composition, and density. These simulated projection images were added to patient projection images acquired with the fourth-generation breast CT scanner from UC Davis (Doheny) and reconstructed using the Feldkamp filtered backprojection algorithm with varying apodization kernels. Volumes of interest and maximum intensity projections were extracted from the reconstructed volumes. Human observers (HOs) and deep learning model observers (DLMOs) were used to detect calcification clusters, and receiver operating characteristic curve analysis was used to analyze detection performance.ResultsDLMO detected 0.18-mm type I calcifications with AUC = 0.80 and 0.21 mm calcifications with AUC=0.99. HO performance was inferior to deep learning model observer performance, but both HO and DLMO detected 0.21-mm type I calcifications with AUC>0.90 and 0.24-mm type I calcifications with near-perfect performance. Microcalcification clusters embedded in adipose tissue were more conspicuous than clusters embedded in fibroglandular tissue. There was superior detection performance for clusters located anteriorly within the breast compared with clusters located posteriorly within the breast.ConclusionsA hybrid approach for virtual imaging trials shows promise for the assessment of imaging systems across a broad range of parameters.
- 1 April 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12932, 51-358
Multimodality in silico imaging of dense breasts: a comparative study of ultrasound computed tomography and digital breast tomosynthesis
This study aimed to develop a software tool to simulate ultrasound computed tomography (USCT) scans of a realistic anthropomorphic breast phantom. The tool was incorporated in an existing simulation framework for x-ray based imaging, resulting in a multimodality in silico evaluation framework. Digital breast models were developed utilizing advanced mathematical modeling based on procedural generation techniques to closely mimic the complex structural and compositional heterogeneity observed in human breast tissue. The breast’s acoustic properties, including the speed of sound, density, and acoustic attenuation, were stochastically incorporated into the phantom in preparation for USCT simulation. Full waveform inversion was employed to reconstruct the ultrasound images. We were able to image a dense breast model with multiple modalities in silico. In addition to USCT simulation with the newly developed software, digital breast tomosynthesis, mammography, and computed tomography images of the same phantom were simulated using the GPU-accelerated Monte Carlo transport software MC-GPU. The presented in silico methods can be used to compare the performance of imaging technologies based on completely different physical characteristics, such as x-ray attenuation or ultrasound speed of sound. In silico evaluation has the advantage of enabling task-based evaluation in a fixed anatomy with known disease ground-truth, and without exposure of patients to ionizing radiation. With the required level of verification and validation, this framework could enhance our understanding of the performance of USCT as a standalone modality or as an adjunct to x-ray modalities, potentially providing in silico evidence that could be leveraged in regulatory evaluation of new USCT devices.
- 1 April 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12932, 51-358
Multimodality in silico imaging of dense breasts: a comparative study of ultrasound computed tomography and digital breast tomosynthesis
This study aimed to develop a software tool to simulate ultrasound computed tomography (USCT) scans of a realistic anthropomorphic breast phantom. The tool was incorporated in an existing simulation framework for x-ray based imaging, resulting in a multimodality in silico evaluation framework. Digital breast models were developed utilizing advanced mathematical modeling based on procedural generation techniques to closely mimic the complex structural and compositional heterogeneity observed in human breast tissue. The breast’s acoustic properties, including the speed of sound, density, and acoustic attenuation, were stochastically incorporated into the phantom in preparation for USCT simulation. Full waveform inversion was employed to reconstruct the ultrasound images. We were able to image a dense breast model with multiple modalities in silico. In addition to USCT simulation with the newly developed software, digital breast tomosynthesis, mammography, and computed tomography images of the same phantom were simulated using the GPU-accelerated Monte Carlo transport software MC-GPU. The presented in silico methods can be used to compare the performance of imaging technologies based on completely different physical characteristics, such as x-ray attenuation or ultrasound speed of sound. In silico evaluation has the advantage of enabling task-based evaluation in a fixed anatomy with known disease ground-truth, and without exposure of patients to ionizing radiation. With the required level of verification and validation, this framework could enhance our understanding of the performance of USCT as a standalone modality or as an adjunct to x-ray modalities, potentially providing in silico evidence that could be leveraged in regulatory evaluation of new USCT devices.
- 13 November 2023
- Published by Elsevier in Computer Physics Communications
- Vol. 296
MCGPU-PET: An open-source real-time Monte Carlo PET simulator
- 13 November 2023
- Published by Elsevier in Computer Physics Communications
- Vol. 296
MCGPU-PET: An open-source real-time Monte Carlo PET simulator
- 7 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12463, 19-1010
Towards appropriate use of test phantoms in training deep learning models for mammographic image conversion
We are developing machine learning methods for converting images from a source system to a target image acquisition system. The generated images preserve the anatomical content of a source image and produce the physical characteristics of a target image acquisition system. Our previous results indicated that incorporating slanted edge images into the training dataset improved the performance of the conditional generative adversarial network (cGAN) used for the image conversion. In this study, we investigated the appropriate use of phantom images in training when similar phantoms are used to measure the physical characteristics of the model-generated images. We performed two experiments with different training and testing data settings to study the bias that might be introduced when measuring the high contrast edge preservation (HCEP) capability of the cGAN with edge phantoms used as part of the training dataset. HCEP was measured using techniques borrowed from the measurement of the modulation transfer function (MTF). Our results indicated that using similar edge images in training the cGAN and then in measuring HCEP resulted in a biased estimate of the network performance in reproducing the target system MTF. Augmenting the training phantom data so that the training images were diverse and did not match the edge angle of the test phantom images reduced the bias and improved cGAN performance in modeling the target acquisition system. Moreover, this technique led to an improvement in the multi-scale structural similarity (MS-SSIM) value between the generated and the target breast images. Our results indicated that caution must be exercised when including phantom images in the training of a deep learning network if similar phantom images are also planned to be used for obtaining physical measures of image quality such as the HCEP or MTF.
- 7 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12463, 19-1010
Towards appropriate use of test phantoms in training deep learning models for mammographic image conversion
We are developing machine learning methods for converting images from a source system to a target image acquisition system. The generated images preserve the anatomical content of a source image and produce the physical characteristics of a target image acquisition system. Our previous results indicated that incorporating slanted edge images into the training dataset improved the performance of the conditional generative adversarial network (cGAN) used for the image conversion. In this study, we investigated the appropriate use of phantom images in training when similar phantoms are used to measure the physical characteristics of the model-generated images. We performed two experiments with different training and testing data settings to study the bias that might be introduced when measuring the high contrast edge preservation (HCEP) capability of the cGAN with edge phantoms used as part of the training dataset. HCEP was measured using techniques borrowed from the measurement of the modulation transfer function (MTF). Our results indicated that using similar edge images in training the cGAN and then in measuring HCEP resulted in a biased estimate of the network performance in reproducing the target system MTF. Augmenting the training phantom data so that the training images were diverse and did not match the edge angle of the test phantom images reduced the bias and improved cGAN performance in modeling the target acquisition system. Moreover, this technique led to an improvement in the multi-scale structural similarity (MS-SSIM) value between the generated and the target breast images. Our results indicated that caution must be exercised when including phantom images in the training of a deep learning network if similar phantom images are also planned to be used for obtaining physical measures of image quality such as the HCEP or MTF.
- 7 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12463, 152-851
In silico tools for evaluating denoising and super-resolution algorithms applied to radiographic images
Sophisticated non-linear image processing techniques based on machine learning, such as denoising and superresolution, are being aggressively incorporated into the clinical practice of radiology. There is a need for equally sophisticated methods to evaluate the performance of these new algorithms, particularly in cases where adaptive processing might behave differently in bench testing phantoms than in patients. This issue has been the subject of intense research in recent years in photography due to the emergence of cell-phone cameras with built-in processing. In this work, we introduce methods used to evaluate image resolution in photography, as defined by the international standards ISO 12233 and IEEE 1858, and describe how some of these methods can be adapted to radiography. We propose the use of a completely in silico pipeline for the evaluation of post-processing software devices, to enable the use of noise-free, high-resolution ground-truth data in the evaluation. A digital twin of a mammography device, based on the open-source VICTRE MC-GPU x-ray simulator which accurately replicates the noise and loss of resolution in clinical mammograms, was used as a test bed to study different evaluation methods. Three upgrades to the simulation software were implemented: a charge-sharing mechanism to model pixel correlations, fast primary-only x-ray tracking, and insertion of a 2D image of arbitrary resolution inside a voxelized 3D geometry. These new capabilities were used to insert complex image quality evaluation charts, such as the sine-wave Siemens star, slanted-edge, and “dead leaves” pattern, inside simulated mammograms. An innovative adaptation of the “dead leaves” pattern to mammography is introduced. The proposed method uses a noise-free, high-resolution projection of a VICTRE breast phantom as a reference to evaluate the spatial frequency response of the post-processed simulated mammograms. The advantage of this new test pattern is that the effective resolution is calculated directly on the mammogram itself, and deep-learning algorithms are likely to process the pattern in a similar way as a patient image. The introduced computer modeling and simulation methods might provide valuable information to complement bench testing results in the evaluation of image processing algorithms used in radiology.
- 7 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12463, 152-851
In silico tools for evaluating denoising and super-resolution algorithms applied to radiographic images
Sophisticated non-linear image processing techniques based on machine learning, such as denoising and superresolution, are being aggressively incorporated into the clinical practice of radiology. There is a need for equally sophisticated methods to evaluate the performance of these new algorithms, particularly in cases where adaptive processing might behave differently in bench testing phantoms than in patients. This issue has been the subject of intense research in recent years in photography due to the emergence of cell-phone cameras with built-in processing. In this work, we introduce methods used to evaluate image resolution in photography, as defined by the international standards ISO 12233 and IEEE 1858, and describe how some of these methods can be adapted to radiography. We propose the use of a completely in silico pipeline for the evaluation of post-processing software devices, to enable the use of noise-free, high-resolution ground-truth data in the evaluation. A digital twin of a mammography device, based on the open-source VICTRE MC-GPU x-ray simulator which accurately replicates the noise and loss of resolution in clinical mammograms, was used as a test bed to study different evaluation methods. Three upgrades to the simulation software were implemented: a charge-sharing mechanism to model pixel correlations, fast primary-only x-ray tracking, and insertion of a 2D image of arbitrary resolution inside a voxelized 3D geometry. These new capabilities were used to insert complex image quality evaluation charts, such as the sine-wave Siemens star, slanted-edge, and “dead leaves” pattern, inside simulated mammograms. An innovative adaptation of the “dead leaves” pattern to mammography is introduced. The proposed method uses a noise-free, high-resolution projection of a VICTRE breast phantom as a reference to evaluate the spatial frequency response of the post-processed simulated mammograms. The advantage of this new test pattern is that the effective resolution is calculated directly on the mammogram itself, and deep-learning algorithms are likely to process the pattern in a similar way as a patient image. The introduced computer modeling and simulation methods might provide valuable information to complement bench testing results in the evaluation of image processing algorithms used in radiology.
- 4 April 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12035, 16-25
Analyzing neural networks applied to an anatomical simulation of the breast
In the last 5 to 10 years, there has been an enormous increase in the interest and use of network models in imaging. These are being considered for numerous imaging applications, including denoising, decision support, learned-feature selection, and many others. Network models “learn” solutions to imaging problems from labelled training data and an elaborate training regime. When a successful model is developed, it represents a computational algorithm for performing some task of interest. But it also encodes a solution to an imaging problem that may be intractable by conventional analytical means. Network models are therefore of interest for how they formulate a solution to a problem of interest. This work focuses on that process. We present two case studies in the analysis of neural networks. The first consists of a denoising network for digital breast tomosynthesis (DBT) images developed using a complex anatomical simulation of breast tissues and realistic x-ray transport physics. The second looks at a lesion detection network, also for DBT images, based on the same anatomical simulation model. For the denoising network, we find that it is very well represented by a linear operation that is effectively a Gaussian convolution kernel. The detection filter appears to be locally linear, but the filter profile appears to depend on what stimulus is used to probe the network. There does not appear to be any clear structure in quadratic components from reverse correlation. Overall, this study shows how regression and reverse-correlation techniques can be used to analyze network models.
- 4 April 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12035, 16-25
Analyzing neural networks applied to an anatomical simulation of the breast
In the last 5 to 10 years, there has been an enormous increase in the interest and use of network models in imaging. These are being considered for numerous imaging applications, including denoising, decision support, learned-feature selection, and many others. Network models “learn” solutions to imaging problems from labelled training data and an elaborate training regime. When a successful model is developed, it represents a computational algorithm for performing some task of interest. But it also encodes a solution to an imaging problem that may be intractable by conventional analytical means. Network models are therefore of interest for how they formulate a solution to a problem of interest. This work focuses on that process. We present two case studies in the analysis of neural networks. The first consists of a denoising network for digital breast tomosynthesis (DBT) images developed using a complex anatomical simulation of breast tissues and realistic x-ray transport physics. The second looks at a lesion detection network, also for DBT images, based on the same anatomical simulation model. For the denoising network, we find that it is very well represented by a linear operation that is effectively a Gaussian convolution kernel. The detection filter appears to be locally linear, but the filter profile appears to depend on what stimulus is used to probe the network. There does not appear to be any clear structure in quadratic components from reverse correlation. Overall, this study shows how regression and reverse-correlation techniques can be used to analyze network models.
- Open Access
- 10 December 2021
- Published by Wiley in Radiology Research and Practice
- Vol. 2021, 1-18
A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator
Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.602.56) μSv, and panoramic, 17.93 (3.4775.00) μSv, procedures were found to be about1 and 15 of that delivered by CBCT, 121.09 (17.10392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29 more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150cm2) was about 1.6 times greater than that of a small FOV (2). The maximum CBCT effective dose with a large FOV for children, 392.2μSv, was about 13 of theeffective dose that a person receives on average every year from natural radiation, 3110μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.
- 10 December 2021
- Published by Wiley in Radiology Research and Practice
- Vol. 2021, 1-18
Open AccessA Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator
Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.602.56) μSv, and panoramic, 17.93 (3.4775.00) μSv, procedures were found to be about1 and 15 of that delivered by CBCT, 121.09 (17.10392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29 more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150cm2) was about 1.6 times greater than that of a small FOV (2). The maximum CBCT effective dose with a large FOV for children, 392.2μSv, was about 13 of theeffective dose that a person receives on average every year from natural radiation, 3110μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.
- Open Access
- 23 September 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (10) , 222-231
Method to measure the size of a radiographic field larger than a detector by imaging fluorescence X‐rays with a slit camera
Purpose: X‐ray imaging devices contain a collimator system that defines a rectangular irradiation field on the detector plane. The size and position of the X‐ray field, and its congruence with the corresponding light field, must be regularly tested for quality control. We propose a new method to estimate how far the x‐ray field extends beyond the detector which does not require the use of external detectors.Methods: A metallic foil is inserted perpendicularly between the source and the detector. A slit camera, a linear extension of a pinhole camera, is used to project onto the detector the fluorescence X‐rays emitted by the irradiated foil. The location where the fluorescence signal inside the camera vanishes is used to extrapolate the location of the field boundary. Monte Carlo simulations were performed to determine the optimal composition and thickness of the foil. A prototype camera with a 1‐mm‐wide slit was built and tested in a clinical mammography and digital breast tomosynthesis (DBT) system.Results: The simulations estimated that a foil made of 25 µm of Molybdenum provided the maximum signal inside the camera for a 39 kVp beam. The boundary of the X‐ray fields in mammography and DBT views were experimentally measured. With the camera along the chest wall side, the measured field in multiple DBT views had a variability of only 0.4 ± 0.1 mm compared to mammography. A difference in the measured boundary position of 2.4 and –1.0 mm was observed when comparing to measurements with a fluorescent ruler and self‐developing film.Conclusion: The introduced technique provides a practical alternative method to detect the boundary of an X‐ray field. The method can be combined with other testing methods to assess the congruence of the X‐rays and light fields, and to determine if the X‐ray field extends beyond the detector more than permitted.
- 23 September 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (10) , 222-231
Open AccessMethod to measure the size of a radiographic field larger than a detector by imaging fluorescence X‐rays with a slit camera
Purpose: X‐ray imaging devices contain a collimator system that defines a rectangular irradiation field on the detector plane. The size and position of the X‐ray field, and its congruence with the corresponding light field, must be regularly tested for quality control. We propose a new method to estimate how far the x‐ray field extends beyond the detector which does not require the use of external detectors.Methods: A metallic foil is inserted perpendicularly between the source and the detector. A slit camera, a linear extension of a pinhole camera, is used to project onto the detector the fluorescence X‐rays emitted by the irradiated foil. The location where the fluorescence signal inside the camera vanishes is used to extrapolate the location of the field boundary. Monte Carlo simulations were performed to determine the optimal composition and thickness of the foil. A prototype camera with a 1‐mm‐wide slit was built and tested in a clinical mammography and digital breast tomosynthesis (DBT) system.Results: The simulations estimated that a foil made of 25 µm of Molybdenum provided the maximum signal inside the camera for a 39 kVp beam. The boundary of the X‐ray fields in mammography and DBT views were experimentally measured. With the camera along the chest wall side, the measured field in multiple DBT views had a variability of only 0.4 ± 0.1 mm compared to mammography. A difference in the measured boundary position of 2.4 and –1.0 mm was observed when comparing to measurements with a fluorescent ruler and self‐developing film.Conclusion: The introduced technique provides a practical alternative method to detect the boundary of an X‐ray field. The method can be combined with other testing methods to assess the congruence of the X‐rays and light fields, and to determine if the X‐ray field extends beyond the detector more than permitted.
- 13 May 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (03) , 1-16
Exploring CNN potential in discriminating benign and malignant calcifications in conventional and dual-energy FFDM: simulations and experimental observations
The Journal of Medical Imaging allows for the peer-reviewed communication and archiving of fundamental and translational research, as well as applications, focused on medical imaging, a field that continues to benefit from technological improvements and yield biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal conditions.
- 13 May 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (03) , 1-16
Exploring CNN potential in discriminating benign and malignant calcifications in conventional and dual-energy FFDM: simulations and experimental observations
The Journal of Medical Imaging allows for the peer-reviewed communication and archiving of fundamental and translational research, as well as applications, focused on medical imaging, a field that continues to benefit from technological improvements and yield biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal conditions.
- 29 September 2020
- Published by Springer Nature
- p. 523-531
Mammographic Image Conversion Between Source and Target Acquisition Systems Using cGAN
- 29 September 2020
- Published by Springer Nature
- p. 523-531
Mammographic Image Conversion Between Source and Target Acquisition Systems Using cGAN