Hybrid simulation of breast CT for assessing microcalcification detectability
- 3 July 2025
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-17
Abstract
PurposeVirtual imaging trials (VITs) are of interest for regulatory evaluation because they enable faster and more cost-effective evaluation of new imaging technologies than patient clinical trials. Our purpose is to develop a hybrid VIT methodology for breast computed tomography (CT) applications and use it to investigate microcalcification detectability.ApproachRay tracing was used to generate projection images of clusters of five microcalcifications which varied in diameter, chemical composition, and density. These simulated projection images were added to patient projection images acquired with the fourth-generation breast CT scanner from UC Davis (Doheny) and reconstructed using the Feldkamp filtered backprojection algorithm with varying apodization kernels. Volumes of interest and maximum intensity projections were extracted from the reconstructed volumes. Human observers (HOs) and deep learning model observers (DLMOs) were used to detect calcification clusters, and receiver operating characteristic curve analysis was used to analyze detection performance.ResultsDLMO detected 0.18-mm type I calcifications with AUC = 0.80 and 0.21 mm calcifications with AUC=0.99. HO performance was inferior to deep learning model observer performance, but both HO and DLMO detected 0.21-mm type I calcifications with AUC>0.90 and 0.24-mm type I calcifications with near-perfect performance. Microcalcification clusters embedded in adipose tissue were more conspicuous than clusters embedded in fibroglandular tissue. There was superior detection performance for clusters located anteriorly within the breast compared with clusters located posteriorly within the breast.ConclusionsA hybrid approach for virtual imaging trials shows promise for the assessment of imaging systems across a broad range of parameters.Keywords
Funding Information
- U.S. Food and Drug Administration Office of Women’s Health
This publication has 29 references indexed in Scilit:
- Effect of slice thickness on detectability in breast CT using a prewhitened matched filter and simulated mass lesionsMedical Physics, 2012
- The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesisMedical Physics, 2011
- Development and characterization of an anthropomorphic breast software phantom based upon region-growing algorithmMedical Physics, 2011
- The characterization of breast anatomical metrics using dedicated breast CTMedical Physics, 2011
- Dedicated Breast CT: Initial Clinical ExperienceRadiology, 2008
- A computer simulation platform for the optimization of a breast tomosynthesis systemMedical Physics, 2007
- Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulationMedical Physics, 2002
- Breast tumors: composition of microcalcifications.Radiology, 1988
- Different types of microcalcifications observed in breast pathologyVirchows Archiv, 1987
- [Diagnostic value of clustered microcalcifications discovered by mammography (apropos of 227 cases with histological verification and without a palpable breast tumor)].1984