FBFrank A. Bracke

Frank A. Bracke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Frank A. Bracke has a total of 117 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Subcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial

    by Reinoud E. Knops, Christelle Marquie, Peter Nordbeck, Roland Tilz, Leonard A. Dijkshoorn, Anne-Floor B.E. Quast, Tom F. Brouwer, Pier D. Lambiase, Christopher Cassidy, Lucas V.A. Boersma, et al.

    Background: To improve survival in patients at risk of sudden cardiac death, subcutaneous ICDs (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes based on chest X-rays. The PRAETORIAN-DFT trial evaluated whether omission of DF testing guided by the PRAETORIAN score is non-inferior for first-shock efficacy. Methods: In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary endpoint was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for non-inferiority with a 3% absolute risk margin. Secondary endpoints included mortality, potential DF testing-related complications, and S-ICD revisions. Results: The included 965 patients (No-DF testing, n=483;DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (–0.6%, 95% CI [ –2.6 to 1.4]; p<0.001). There were no significant differences in all-cause mortality (HR 0.9 [95% CI 0.6–1.4]) or arrhythmic death (HR 0.4 [95% CI 0.04–3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). Conclusions: PRAETORIAN score–guided omission of DF testing- after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. (Funded by Boston Scientific; PRAETORIAN-DFT).


  • Open Access

    Inappropriate Therapy and Shock Rates Between the Subcutaneous and Transvenous Implantable Cardiac Defibrillator: A Secondary Analysis of the PRAETORIAN Trial

    by Louise R.A. Olde Nordkamp, Shari Pepplinkhuizen, Abdul Ghani, Lucas V.A. Boersma, Juergen Kuschyk, Mikhael F. El-Chami, Elijah R. Behr, Tom F. Brouwer, Stefan Kääb, Suneet Mittal, et al.

    BACKGROUND: Inappropriate therapy (IAT) is an undesirable side effect of implantable cardiac defibrillator (ICD) therapy. Early studies with the subcutaneous ICD (S-ICD) showed relatively high inappropriate shock (IAS) rates. The PRAETORIAN (Prospective Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) trial demonstrated that the S-ICD is noninferior to the transvenous ICD (TV-ICD) with regard to the combined end point of IAS and complications. This secondary analyses evaluates all IAT in the PRAETORIAN trial. METHODS: This international, multicenter trial randomized 849 patients with an indication for ICD therapy between S-ICD (n=426) and TV-ICD therapy (n=423). ICD programming was mandated by protocol. All analysis were performed in the modified intention-to-treat population. RESULTS: In both groups 42 patients experienced IAT (48-month Kaplan-Meier estimated cumulative incidence, 9.9% and 10.1%, respectively; hazard ratio (HR), 0.99 [95% CI, 0.65–1.52]; P =0.97). There was no significant difference in patients experiencing IAS between both groups ( P =0.14). In the S-ICD group, 81 IAT episodes with 124 IAS and 1 inappropriate antitachycardia pacing occurred versus 89 IAT episodes with 130 IAS and 124 inappropriate antitachycardia pacing in the TV-ICD group. IAT episodes were most frequently caused by supraventricular tachycardias in the TV-ICD group (n=83/89) versus cardiac oversensing in the S-ICD group (n=40/81). In the TV-ICD group, a baseline heart rate >80 bpm (HR, 1.99 [95% CI, 1.05–3.76]; P =0.03), a history of atrial fibrillation (HR, 2.66 [95% CI, 1.41–5.02]; P =0.003), and smoking (HR, 2.46 [95% CI, 1.31–4.09]; P =0.005) were independent predictors for IAT. A QRS duration >120 ms was an independent predictor for IAT caused by cardiac oversensing in the S-ICD group (HR, 3.13 [95% CI, 1.34–7.31]; P =0.008). Post-IAS interventions significantly reduced IAS recurrence in both groups ( P =0.046). CONCLUSIONS: There was no significant difference in IAT and IAS rates between the S-ICD and TV-ICD in a conventional ICD population, but causes and predictors for IAT differed between the devices. After the first IAS, an intervention significantly reduced the recurrence rate of IAS. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.


  • Open Access

    Quality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial

    by Reinoud E. Knops, Jolien A. de Veld, Abdul Ghani, Lucas V.A. Boersma, Juergen Kuschyk, Mikhael F. El Chami, Hendrik Bonnemeier, Elijah R. Behr, Tom F. Brouwer, Stefan Kääb, et al.

    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.


  • Open Access

    Extraction of non-infected redundant pacing and defibrillator leads does not result in better patient outcomes

    by Frank A. Bracke, Leonard M. Rademakers, Dennis van Veghel

    The introduction of dedicated tools for pacing and defibrillator lead extraction has resulted in relatively high success and low complication rates. The confidence this elicits has broadened the indications from device infections to non-functional or redundant leads and the latter make up an increasing share of extraction procedures. Proponents of extracting these leads point to the higher complication burden of lead extraction in patients with longstanding abandoned leads when compared one-to-one with extraction when these leads become redundant. However, this does not translate into better patient outcomes on a population level: complications are rare with properly abandoned leads and thus most patients will never be subjected to an extraction procedure and the ensuing complications. Therefore, not extracting redundant leads minimises the risk for the patients and avoids many expensive procedures.


  • Open Access

    Comparison between laser sheaths, femoral approach and rotating mechanical sheaths for lead extraction

    by F. A. Bracke, N. Rademakers, N. Verberkmoes, M. Van ’t Veer, B. M. van Gelder

    Introduction: Efficiency and safety are important features in the selection of lead extraction tools. We report our experience with different endovascular techniques to extract individual pacing and defibrillator leads. Methods: This is a single-centre study of consecutive lead extraction procedures from 1997 until 2019. A total of 1725 leads were extracted in 775 patients. Direct traction sufficed for 588 leads, and 22 leads were primarily removed by surgery. The endovascular techniques used in the remainder were a laser sheath (190 leads), the femoral approach (717 leads) and rotating mechanical sheaths (208 leads). Results: The three approaches were comparably effective in completely removing the leads (p = 0.088). However, there were more major complications with the laser sheath than with the femoral approach or rotating mechanical sheaths (8.4%, 0.5% and 1.2%, respectively). Therefore, the procedural result—extraction without major complications—was significantly better with both the femoral approach and rotating mechanical sheaths than with the laser sheath (p < 0.001). This result was confirmed after propensity score matching to compensate for differences between lead cohorts (p = 0.007). Cross-over to another endovascular tool was necessary in 7.9%, 7.1% and 8.2% of laser, femoral and rotating mechanical attempts, respectively. Conclusion: All three endovascular lead extraction techniques showed comparable efficacy. However, there were significantly more major complications using the laser sheath compared to the femoral approach or rotating mechanical sheaths, leading us to abandon the laser technique. Importantly, no single endovascular technique sufficed to successfully extract all leads.


  • Lead extraction for cardiac implantable electronic device infection: comparable complication rates with or without abandoned leads

    by Frank Bracke, Niels Verberkmoes, Marcel van 'T Veer, Berry van Gelder

    Aims: Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection. Methods and results: All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6–38.2) and 11.6 (5.6–17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration. Conclusion: Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.


  • Open Access

    687Cardiomyoapthic aetiology affects the distribution of endocardial electrical latency; results from a multi-centre registry

    by B Sieniewicz, J Behar, M Sohal, B Porter, S Claridge, S Niederer, J Gamble, T R Betts, P Jais, N Derval, et al.

    Background: Biventricular endocardial (BIV ENDO) pacing may offer a potential benefit over standard CRT, especially in non-responders however the optimal left ventricular endocardial (LV ENDO) pacing site displays marked inter and intra-patient variability. Identifying and targeting late activating, viable tissue appears important.

  • 533Does targeting the site of maximal electrical delay result in the optimal haemodynamic improvement; results from an international multi-centre registry

    by B Sieniewicz, J Behar, M Sohal, S Claridge, B Porter, S Niederer, J Gamble, T R Betts, P Jais, N Derval, et al.

    Background: Biventricular endocardial (BIV ENDO) pacing may offer a potential benefit over standard CRT, especially in non-responders however the optimal left ventricular endocardial (LV ENDO) pacing site displays marked inter and intra-patient variability. Identifying and targeting late activating, viable tissue appears important.

  • Timely detection of superior vena cava laceration with thoracoscopy during lead extraction

    by Frank A. Bracke, Niels Verberkmoes, Berry M. van Gelder