Lead extraction for cardiac implantable electronic device infection: comparable complication rates with or without abandoned leads
Authors:
- 19 July 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (9) , 1378-1384
Abstract
Aims: Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection. Methods and results: All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6–38.2) and 11.6 (5.6–17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration. Conclusion: Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.Keywords
This publication has 18 references indexed in Scilit:
- Timely detection of superior vena cava laceration with thoracoscopy during lead extractionHeart Rhythm, 2016
- Outcomes of Sprint Fidelis and Riata lead extraction: Data from 2 high-volume centersHeart Rhythm, 2015
- How adequate are the current methods of lead extraction? A review of the efficiency and safety of transvenous lead extraction methodsEP Europace, 2015
- Safety of transvenous lead extraction according to centre volume: a systematic review and meta-analysisEP Europace, 2014
- Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractionsHeart Rhythm, 2014
- Transvenous extraction of implantable cardioverter-defibrillator leads under advisory—A comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leadsHeart Rhythm, 2013
- The Needle's Eye Snare as a primary tool for pacing lead extractionEP Europace, 2012
- Lead Extraction in the Contemporary Setting: The LExICon StudyJACC, 2010
- Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leadsEuropean Heart Journal, 2008
- Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial11No financial support was received for performing the procedures or collecting the data, or for data analysis.JACC, 1999