PSPratik Shah

Pratik Shah

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pratik Shah has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Matrix Element-Based Theory of Compressive Sensing and Its Application to Electromagnetic Imaging

    by Pratik Shah, Mahta Moghaddam

    We present a simple and general theory of compressive sensing (CS) that relies on elements of the sensing matrix rather than on the number of measurements. We prove the exact recovery using a dual certificate by showing that the sensing matrix satisfies an incoherence property and isotropy property if the sparsity level is kept lower than the reciprocal of the largest element of a matrix created from the sensing matrix. Unlike the CS literature, this unconventional approach does not require a linear relationship between the sparsity and the number of measurements and at the same time, can easily be evaluated. This adaptability captures anisotropic measurements appropriately as with anisotropic measurements, adding more measurements does not really imply that a signal with more nonzero elements will be recovered exactly. As an illustration, we demonstrate the theory’s ability to accurately handle the anisotropic (Green’s function-based sensing matrix) measurements and also its similarity to the existing CS literature for isotropic (Fourier) measurements. Further, we show the usefulness of the theory in comparing different sensing matrices and in generating dielectric images. The dielectric images are perfectly recovered even when there is only a single transmitter.

  • Learning-Assisted Multimodality Dielectric Imaging

    by Guanbo Chen, Pratik Shah, John Stang, Mahta Moghaddam

    We introduce a Convolutional Neural Network (CNN) assisted dielectric imaging method, which uses CNN to incorporate the abundant image information from Magnetic Resonance (MR) images into the model-based microwave inverse scattering imaging process and generate high-fidelity dielectric images. A CNN is designed and trained to learn the complex mapping function from MR T1 images to dielectric images. Once trained, the new patients’ MR T1 images are fed into the CNN to generate predicted dielectric images, which are used as the starting image for the microwave inverse scattering imaging. The CNN-predicted dielectric image, containing abundant prior information from MR images, significantly reduces the non-linearity and ill-posedness of the inverse scattering problem. We demonstrate the application of the proposed method to recover human brain dielectric images at 4 mm and 2 mm resolution with single-frequency and multi-frequency microwave measurements. The reconstructed brain dielectric images with the proposed method show significant improvements in image quality compared with images reconstructed with no assistance from MR and CNN.


  • 3-D Level Set Method for Joint Contrast and Shape Recovery in Microwave Imaging

    by Pratik Shah, Guanbo Chen, John Stang, Mahta Moghaddam

    We propose a 3D fast level set method, which can estimate both object shape and dielectric contrast with reduced computational cost. In prior work, we presented a 2D fast level set method that integrated the level set inversion within the Born Iterative Method (BIM). That approach significantly reduced the computational cost; however, it was limited to estimating object shape without providing any dielectric contrast inversion. In this work, we extend our previous method to 3D and add the capability to estimate dielectric contrast in addition to the shape. The contrast estimation is formulated as a separate step within the BIM iteration, such that shape and contrast are estimated sequentially in each BIM iteration. This modular framework enables the freedom to choose any arbitrary constraints on the contrast in the cost function. Here, we demonstrate the applicability of a total-variation (TV) constraint for the contrast cost function. To validate the method, synthetic data are generated for objects within a three-dimensional imaging cavity and are then used to test for robustness against variations in object shape, size, position, and contrast. Further, the method is tested on MRI-derived numerical breast phantoms. The reconstructed images indicate that the method can produce accurate estimates of object location, shape, and size while recovering the contrast with an error lower than $2\%$ .


  • Matrix norm based method for recovery of high contrast and sparse objects in microwave imaging

    by Pratik Shah, Mahta Moghaddam

    The application of matrix-norm-minimization based compressive sensing (CS) for inverse scattering problems is discussed. In particular, two CS - based techniques are developed and compared to solve the imaging problem in a 2D sparse domain. The two proposed methods are (i) mix-norm constrained minimization and (ii) proposed joint minimization of a matrix rank and element-wise sparsity of the matrix. The problem is formulated as a linear system in contrast source as an unknown variable. A set of numerical simulations is presented to convey advantages and limitations of the considered methods.

  • Open Access

    Nyquist filter design using POCS methods: Including constraints in design

    by Sanjeel Parekh, Pratik Shah

    The problem of constrained finite impulse response (FIR) filter design is central to signal processing and arises in a variety of disciplines. This paper surveys the design of such filters using Projection onto convex sets (POCS) and discusses certain commonly encountered time and frequency domain constraints. We study in particular the design of Nyquist filters and propose a simple extension to the work carried out by Haddad, Stark and Galatsanos in [1]. The flexibility and the ease that this design method provides in terms of accommodating constraints is one of its outstanding features.