Saidhbhe L. O'RIordan
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Saidhbhe L. O'RIordan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- John Patrick Lowry
Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland
5 shared publications - Niall J. Finnerty
Chemistry Department, Maynooth University, Co. Kildare, Ireland
2 shared publications - Coughlan
Department of Physiology and Medical Physics, Centre for the Study of Neurological Disorders, Royal College of Surgeons in Ireland, 123 St. Stephen's Green, Dublin 2, Ireland
1 shared publication Daniel Klamer
Department of Pharmacology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
1 shared publication- Erik Pålsson
Institute of Neuroscience and Physiology, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden
1 shared publication Finbar O. Brown
Sensors Development Unit and Neurochemistry Research Unit, BioAnalytics Laboratory, Department of Chemistry, National University of Ireland Maynooth, Co. Kildare, Ireland
1 shared publication
Latest Publications
- 1 May 2018
- Published by Elsevier in Neuropharmacology
- Vol. 133, 503-511
Pleiotropic activity of systemically delivered angiogenin in the SOD1G93A mouse model
- 1 May 2018
- Published by Elsevier in Neuropharmacology
- Vol. 133, 503-511
Pleiotropic activity of systemically delivered angiogenin in the SOD1G93A mouse model
- 2 February 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (8) , 1253-1264
In vivo characterisation of a catalase-based biosensor for real-time electrochemical monitoring of brain hydrogen peroxide in freely-moving animals
A catalase-based microelectrochemical biosensor developed for real-time neurochemical monitoring of hydrogen peroxide (H2O2) was characterised in freely-moving rats.
- 2 February 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (8) , 1253-1264
In vivo characterisation of a catalase-based biosensor for real-time electrochemical monitoring of brain hydrogen peroxide in freely-moving animals
A catalase-based microelectrochemical biosensor developed for real-time neurochemical monitoring of hydrogen peroxide (H2O2) was characterised in freely-moving rats.
- 12 October 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (42) , 7614-7622
In vitro physiological performance factors of a catalase-based biosensor for real-time electrochemical detection of brain hydrogen peroxide in freely-moving animals
Physiological performance factors of a catalase-based paired microelectrochemical biosensor, developed for real-time neurochemical monitoring of hydrogen peroxide (H2O2), were determined in the in vitro environment. The excellent ascorbic acid (AA) rejection characteristics and high sensitivity of the paired H2O2 sensor were assessed and verified. The highly suitable response time of the H2O2 sensor was demonstrated and the limit of detection of this sensor was calculated as ca. 0.075 μM. The H2O2 sensor was selective over the electroactive substance Mercaptosuccinate which is used in vivo to disrupt the enzymatic degradation of brain H2O2. The H2O2 sensing element of this paired design was impervious to an acidic/basic shift in environmental pH (6.5/8.0) relative to physiological levels (7.4). The influence of a temperature transition (ca. 23 °C to 37 °C) and a physiological temperature fluctuation expected to be found in vivo (1–4 °C), on the response of the paired H2O2 sensor was deemed negligible and consistent with other amperometric methods. The enzymatic component of the paired H2O2 sensor was found to be stable over a 14 day period of continuous ex vivo brain tissue exposure.
- 12 October 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (42) , 7614-7622
In vitro physiological performance factors of a catalase-based biosensor for real-time electrochemical detection of brain hydrogen peroxide in freely-moving animals
Physiological performance factors of a catalase-based paired microelectrochemical biosensor, developed for real-time neurochemical monitoring of hydrogen peroxide (H2O2), were determined in the in vitro environment. The excellent ascorbic acid (AA) rejection characteristics and high sensitivity of the paired H2O2 sensor were assessed and verified. The highly suitable response time of the H2O2 sensor was demonstrated and the limit of detection of this sensor was calculated as ca. 0.075 μM. The H2O2 sensor was selective over the electroactive substance Mercaptosuccinate which is used in vivo to disrupt the enzymatic degradation of brain H2O2. The H2O2 sensing element of this paired design was impervious to an acidic/basic shift in environmental pH (6.5/8.0) relative to physiological levels (7.4). The influence of a temperature transition (ca. 23 °C to 37 °C) and a physiological temperature fluctuation expected to be found in vivo (1–4 °C), on the response of the paired H2O2 sensor was deemed negligible and consistent with other amperometric methods. The enzymatic component of the paired H2O2 sensor was found to be stable over a 14 day period of continuous ex vivo brain tissue exposure.
- 1 May 2015
- Published by Elsevier in Nitric Oxide
- Vol. 47, 52-57
Increased brain nitric oxide levels following ethanol administration
- 1 May 2015
- Published by Elsevier in Nitric Oxide
- Vol. 47, 52-57
Increased brain nitric oxide levels following ethanol administration
- 1 January 2013
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 3 (3) , 351-362
Continuous Real-Time in vivo Measurement of Cerebral Nitric Oxide Supports Theoretical Predictions of an Irreversible Switching in Cerebral ROS after Sufficient Exposure to External Toxins
Background: Mathematical models of the interactions between alphasynuclein (αS) and reactive oxygen species (ROS) predict a systematic and irreversible switching to damagingly high levels of ROS after sufficient exposure to risk factors associated with Parkinson's disease (PD). Objectives: We tested this prediction by continuously monitoring real-time changes in neurochemical levels over periods of several days in animals exposed to a toxin known to cause Parkinsonian symptoms. Methods: Nitric oxide (NO) sensors were implanted in the brains of freely moving rats and the NO levels continuously recorded while the animals were exposed to paraquat (PQ) injections of various amounts and frequencies. Results: Long-term, real-time measurement of NO in a cohort of animals showed systematic switching in levels when PQ injections of sufficient size and frequency were administered. The experimental observations of changes in NO imply a corresponding switching in endogenous ROS levels and support theoretical predictions of an irreversible change to damagingly high levels of endogenous ROS when PD risks are sufficiently large. Conclusions: Our current results only consider one form of PD risk, however, we are sufficiently confident in them to conclude that: (i) continuous long-term measurement of neurochemical dynamics provide a novel way to measure the temporal change and system dynamics which determine Parkinsonian damage, and (ii) the bistable feedback switching predicted by mathematical modelling seems to exist and that a deeper analysis of its characteristics would provide a way of understanding the pathogenic mechanisms that initiate Parkinsonian cell damage.
- 1 January 2013
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 3 (3) , 351-362
Continuous Real-Time in vivo Measurement of Cerebral Nitric Oxide Supports Theoretical Predictions of an Irreversible Switching in Cerebral ROS after Sufficient Exposure to External Toxins
Background: Mathematical models of the interactions between alphasynuclein (αS) and reactive oxygen species (ROS) predict a systematic and irreversible switching to damagingly high levels of ROS after sufficient exposure to risk factors associated with Parkinson's disease (PD). Objectives: We tested this prediction by continuously monitoring real-time changes in neurochemical levels over periods of several days in animals exposed to a toxin known to cause Parkinsonian symptoms. Methods: Nitric oxide (NO) sensors were implanted in the brains of freely moving rats and the NO levels continuously recorded while the animals were exposed to paraquat (PQ) injections of various amounts and frequencies. Results: Long-term, real-time measurement of NO in a cohort of animals showed systematic switching in levels when PQ injections of sufficient size and frequency were administered. The experimental observations of changes in NO imply a corresponding switching in endogenous ROS levels and support theoretical predictions of an irreversible change to damagingly high levels of endogenous ROS when PD risks are sufficiently large. Conclusions: Our current results only consider one form of PD risk, however, we are sufficiently confident in them to conclude that: (i) continuous long-term measurement of neurochemical dynamics provide a novel way to measure the temporal change and system dynamics which determine Parkinsonian damage, and (ii) the bistable feedback switching predicted by mathematical modelling seems to exist and that a deeper analysis of its characteristics would provide a way of understanding the pathogenic mechanisms that initiate Parkinsonian cell damage.
- 11 January 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 4 (2) , 550-557
In vivo characterisation of a Nafion®-modified Pt electrode for real-time nitric oxide monitoring in brain extracellular fluid
A Nafion ®-modified Pt sensor developed for real-time neurochemical monitoring in freely-moving animals has now been characterised in vivo for the detection of nitric oxide (NO). Experiments were undertaken to test sensitivity, selectivity and stability. In control experiments, local administration of aCSF resulted in a decrease in signal (42 ± 12 pA, n = 9), while systemic administration of saline caused a transient increase in signal (22 ± 3 pA, n = 9) from baseline levels. Local MD perfusions of known concentrations of NO (1 mM) and L-arginine (720 μM) caused significant increases in current (4 ± 1 nA (n = 7) and 271 ± 37 pA (n = 5) respectively) while systemic administration of the non-selective NOS inhibitor L-NAME produced a significant decrease in current (91 ± 19 pA, n = 4) compared to baseline levels. Confirmation that the sensor remained selective was achieved by injection of ascorbic acid (2 g kg−1, i.p). The oxidation current showed no variation over the selected time interval of 60 min, indicating no deterioration of the polymer membrane. Finally, after an initial decrease in sensitivity (ca. 50%) within the first 24 h of implantation the Nafion ®-modified Pt sensor showed excellent stability under physiological conditions over extended periods (8 days) validating its use for continuous chronic in vivo recordings.
- 11 January 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 4 (2) , 550-557
In vivo characterisation of a Nafion®-modified Pt electrode for real-time nitric oxide monitoring in brain extracellular fluid
A Nafion ®-modified Pt sensor developed for real-time neurochemical monitoring in freely-moving animals has now been characterised in vivo for the detection of nitric oxide (NO). Experiments were undertaken to test sensitivity, selectivity and stability. In control experiments, local administration of aCSF resulted in a decrease in signal (42 ± 12 pA, n = 9), while systemic administration of saline caused a transient increase in signal (22 ± 3 pA, n = 9) from baseline levels. Local MD perfusions of known concentrations of NO (1 mM) and L-arginine (720 μM) caused significant increases in current (4 ± 1 nA (n = 7) and 271 ± 37 pA (n = 5) respectively) while systemic administration of the non-selective NOS inhibitor L-NAME produced a significant decrease in current (91 ± 19 pA, n = 4) compared to baseline levels. Confirmation that the sensor remained selective was achieved by injection of ascorbic acid (2 g kg−1, i.p). The oxidation current showed no variation over the selected time interval of 60 min, indicating no deterioration of the polymer membrane. Finally, after an initial decrease in sensitivity (ca. 50%) within the first 24 h of implantation the Nafion ®-modified Pt sensor showed excellent stability under physiological conditions over extended periods (8 days) validating its use for continuous chronic in vivo recordings.