SDSilvestro Damiani

Silvestro Damiani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Silvestro Damiani has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photoelectrocatalysis on TiO2 meshes: different applications in the integrated urban water management

    by Maria Cristina Collivignarelli, Alessandro Abbà, Marco Carnevale Miino, Giorgio Bertanza, Sabrina Sorlini, Silvestro Damiani, Hamed Arab, Massimiliano Bestetti, Silvia Franz

    Recently, among AOPs, photoelectrocatalysis (PEC) on TiO2 is gaining interest. In this study, five different real waters sampled in four different points of the integrated urban water management (IUWM) system were tested with PEC and UV alone, for comparison. This work aims to verify the effect of the PEC suggesting the optimal position in IUWM system where the PEC should be located to obtain the best performance. In groundwaters (GWs), PEC effectively removed atrazine-based compounds (> 99%), trichloroethylene, and perchloroethylene (96%), after 15 min of reaction time. However, given the low concentrations of emerging compounds, the synergistic effect of UV radiation with the catalyst and with the polarization of the mesh was not visible, with very few differences compared with the results obtained with UV alone. Pharmaceutical industrial wastewater (IWW) showed a significant increase in biodegradability after 2 h, both if subjected to PEC or UV (200%), despite the absence of COD removal. The PEC applied on IWW from a sewage sludge treatment plant allowed to effectively remove the COD (39.6%) and increase the biodegradability (300%). Good results in terms of COD removal (33.9%) and biodegradability increase (+900%) were also achieved testing PEC on wastewater treatment plant effluent. Except for GWs, PEC allowed significant EEO savings respect to UV alone (76.2–99.1%).


  • Open Access

    Comparison between experimental results of different technologies for arsenic removal from water intended for human consumption

    by Maria Cristina Collivignarelli, Silvestro Damiani, Sabrina Sorlini

    Arsenic contamination in drinking water is a major issue in the present world. Techniques such as oxidation, precipitation and adsorption have been widely used for arsenic removal. The goal of this work is to analyze four case studies where the problem of arsenic contamination in groundwater is faced with an approach that includes experimental activities at laboratory scale and/or pilot scale. The first case study investigates the mechanisms for enhancing arsenic removal with naturally occurring Fe by the addition of an oxidizing agent (KMnO4) or a concentrated basic solution of MnO4− and AlO2−. In the second case study, different experimental tests are carried out at laboratory scale in order to identify the best combination of treatments to be applied at full-scale. The third case study shows the results of experimental studies followed by a full scale upgrading for a drinking water treatment plant (DWTP) with no specific arsenic treatment in the first configuration. At last, the fourth case study investigates the performance of granular ferric oxide (GFO) with arsenic concentrations close to the Italian regulatory limit. A pilot GFO filter was installed in a DWTP. The monitoring results led to the implementation of the GFO filter at full-scale.


  • Resilience of a Combined Chemical-Physical and Biological Wastewater Treatment Facility

    by Maria C. Collivignarelli, Alessandro Abbà, Giorgio Bertanza, Silvestro Damiani, Massimo Raboni

    This work is aimed at assessing the effects of pretreated aqueous wastes stream-fed to a biological nutrient removal (BNR)–activated sludge plant. Aqueous wastes (mainly landfill leachate and liquid residues from chemical and pharmaceutical factories) are pretreated by means of a traditional coagulation-flocculation stage and subsequently sent to the BNR stage together with municipal wastewater. Pretreated aqueous wastes contribute up to about 75% of the influent load, in terms of chemical oxygen demand (COD; average concentration 23,000  mg/L ). The resilience of the system, that is, the capacity to maintain high and stable performances despite sudden perturbations of the input conditions, was evaluated by interrupting the aqueous waste dosage and then progressively restoring the initial condition. The consequent variation of the influent load and composition caused a reduction of the biomass activity, which led to a decrease of the nitrogen removal efficiency (from 89% down to 73%). More than 30 days were required for restoring typical working conditions (in terms of influent load, process performance, and biomass activity), the sludge retention time (SRT) being 23 days.


  • Top Cited Papers

    Treatments for color removal from wastewater: State of the art

    by Maria Cristina Collivignarelli, Alessandro Abbà, Marco Carnevale Miino, Silvestro Damiani


  • Process auditing and performance improvement in a mixed wastewater–aqueous waste treatment plant

    by Maria Cristina Collivignarelli, Giorgio Bertanza, Alessandro Abbà, Silvestro Damiani

    The wastewater treatment process is based on complex chemical, physical and biological mechanisms that are closely interconnected. The efficiency of the system (which depends on compliance with national regulations on wastewater quality) can be achieved through the use of tools such as monitoring, that is the detection of parameters that allow the continuous interpretation of the current situation, and the experimental tests, which allow the measurement of real performance (of a sector, a single treatment or equipment) and the comparison with the following ones. The experimental tests have a particular relevance in the case of municipal wastewater treatment plants fed by a strong industrial component and especially in the case of plants authorized to treat aqueous waste. In this essay a case study is presented, where the application of management tools such as careful monitoring and experimental tests allowed to achieve the technical-economic optimization of the plant: the main results obtained were the reduction of sludge production (from 4,000 t/y w.w. (wet weight) to about 2,200 t/y w.w.) and operating costs (e.g. from 600,000 €/y down to about 350,000 €/y for reagents), the increase of resource recovery and the improvement of the overall process performance.


  • Open Access

    Water Safety Plan for drinking water risk management: the case study of Mortara (Pavia, Italy)

    by Sabrina Sorlini, Michela Biasibetti, Alessandro Abbà, Maria Cristina Collivignarelli, Silvestro Damiani

    The Water Safety Plan (WSP) approach is an iterative method focused on analyzing the risks of water contamination in a drinking water supply system, from catchment to consumer, in order to protect human health. This approach is aimed at identifying and drastically reducing water contamination in the entire drinking water system, through the identification and mitigation or, if possible, elimination of all factors that may cause a chemical, physical, microbiological and radiological risk for water. This study developed a proposal of WSP for the drinking water supply system (DWSS) of Mortara, Italy, in order to understand which are the preliminary evaluation aspects to be considered in the elaboration of a WSP. The DWSS of Mortara (a town of 15,500 inhabitants, located in northern Italy) consists of three drinking water treatment plants (DWTPs), considering the following main contaminants: arsenic, iron, manganese and ammonia. Potential hazardous events and associated hazards were identified in each part of the water supply system. The risk assessment was carried out following the semi‑quantitative approach. The WSP proposal for Mortara was very useful not only as a risk mitigation approach, but also as a cost-effective tool for water suppliers. Furthermore, this approach will reduce public health risk, ensure a better compliance of water quality parameters with regulatory requirements, increase confidence of consumers and municipal authorities, and improve resource management due to intervention planning. Further, some new control measures are proposed by the WSP team within this work.