Ramazan Gürkan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ramazan Gürkan has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Halil İbRahim Ulusoy
Department of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas, 58140, Türkiye
6 shared publications - Nail Altunay
Sivas Cumhuriyet University, Faculty of Science, Department of Chemistry, 58140 Sivas, TÜRKİYE
6 shared publications - Nuket Kartal Temel
Sivas Cumhuriyet Üniversitesi
4 shared publications Ş. Kubilay
University of Yüzüncü Yıl
4 shared publicationsA. Savran
University of Yüzüncü Yıl
3 shared publications- H. Bayram Zengin
Department of Chemistry, Faculty of Sciences, Sivas Cumhuriyet University, TR-58140 Sivas, Turkey
3 shared publications
Latest Publications
- 30 January 2024
- Published by Springer Nature in Chemical Papers
- Vol. 78 (5) , 1-17
Pre-concentration of trace Mn from dairy products through a pH-induced tautomerization/charge transfer complexation before spectrophotometric analysis
- 30 January 2024
- Published by Springer Nature in Chemical Papers
- Vol. 78 (5) , 1-17
Pre-concentration of trace Mn from dairy products through a pH-induced tautomerization/charge transfer complexation before spectrophotometric analysis
- 9 January 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (18) , 7046-7066
Application of ultrasound assisted-cloud point extraction coupled with spectrophotometry for the selective extraction/pre-concentration of low levels of inorganic Hg (as Hg 2 2+ /Hg 2+ ) from liquid matrices
This study presents the analytical characterisation of a low-cost, selective and sensitive method for inorganic Hg (as Hg22+/Hg2+) determination in liquid matrices based on spectrophotometry. The novelty of the study lies in combining the pre-concentration of i-Hg with spectrophotometry after chelation with the 2-aminobenzimidazole modified amidic copolymer to increase the selectivity and sensitivity of the method. The method involves ultrasonic extraction of the samples in a dilute acid mixture of HClO4-HCl-CH3COOH and mixture of Cu(II)-oxalic acid-KCl adjusted to pH 5.0 in parallel, pre-con centration using UA-CPE process on modified amide copolymer, and absorbance measurement at 332 nm using a micro-volume UV-spectrophotometer. The figures of merit were discussed in relation with the demands in the national/international regulations and standards on the determination of toxic i-Hg in water intended for human consumption. After a pre-concentration of 62.5-fold, the limits of detection and quantification (LODs, LOQs) were 0.24 and 0.22 μg L−1 allowing the use of the method for i-Hg determination in liquid matrices such as cold-/hot-spring waters, plain soda, bottled drinking waters, and carbonated soft drinks. For concentrations of Hg22+, Hg2+ and total Hg in the range of −1, the precision was 3.3–8.3%, below and little above the maximum limits of 1.0 µg L−1 set in the mentioned legislation. The recovery of 92–96.4% and the precision in the range of 4.1–5.4% in the analysis of two certified waters were found to be satisfactory, so as to validate the method. The method developed is cost-effective and enables us to achieve i-Hg determination in liquid matrices complying with European legislation. The system has a good potential for the future and analytical perspectives.
- 9 January 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (18) , 7046-7066
Application of ultrasound assisted-cloud point extraction coupled with spectrophotometry for the selective extraction/pre-concentration of low levels of inorganic Hg (as Hg 2 2+ /Hg 2+ ) from liquid matrices
This study presents the analytical characterisation of a low-cost, selective and sensitive method for inorganic Hg (as Hg22+/Hg2+) determination in liquid matrices based on spectrophotometry. The novelty of the study lies in combining the pre-concentration of i-Hg with spectrophotometry after chelation with the 2-aminobenzimidazole modified amidic copolymer to increase the selectivity and sensitivity of the method. The method involves ultrasonic extraction of the samples in a dilute acid mixture of HClO4-HCl-CH3COOH and mixture of Cu(II)-oxalic acid-KCl adjusted to pH 5.0 in parallel, pre-con centration using UA-CPE process on modified amide copolymer, and absorbance measurement at 332 nm using a micro-volume UV-spectrophotometer. The figures of merit were discussed in relation with the demands in the national/international regulations and standards on the determination of toxic i-Hg in water intended for human consumption. After a pre-concentration of 62.5-fold, the limits of detection and quantification (LODs, LOQs) were 0.24 and 0.22 μg L−1 allowing the use of the method for i-Hg determination in liquid matrices such as cold-/hot-spring waters, plain soda, bottled drinking waters, and carbonated soft drinks. For concentrations of Hg22+, Hg2+ and total Hg in the range of −1, the precision was 3.3–8.3%, below and little above the maximum limits of 1.0 µg L−1 set in the mentioned legislation. The recovery of 92–96.4% and the precision in the range of 4.1–5.4% in the analysis of two certified waters were found to be satisfactory, so as to validate the method. The method developed is cost-effective and enables us to achieve i-Hg determination in liquid matrices complying with European legislation. The system has a good potential for the future and analytical perspectives.
- 22 September 2022
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 115, 104931
Novel amide- and imide-co-polymers modified with sulfathiazole as efficient chelator for selective extraction, pre-concentration and determination of trace inorganic antimony (as Sb(III)) from edible vegetable oils by ultrasound assisted-cloud point extraction coupled to micro-volume UV-spectrophotometry
- 22 September 2022
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 115, 104931
Novel amide- and imide-co-polymers modified with sulfathiazole as efficient chelator for selective extraction, pre-concentration and determination of trace inorganic antimony (as Sb(III)) from edible vegetable oils by ultrasound assisted-cloud point extraction coupled to micro-volume UV-spectrophotometry
- 25 May 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (26) , 2596-2607
An indirect method for the analysis of bisphenol A, as a Mn(iii)–chelate complex, in milk samples by ultrasound assisted-cloud point extraction/flame atomic absorption spectrometry
A new indirect method was developed for the selective determination of bisphenol A. The reproducibility was improved using polyvinyl alcohol. A detection limit of 0.23 μg L−1 was obtained in a linear range of 0.8–130 μg L−1.
- 25 May 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (26) , 2596-2607
An indirect method for the analysis of bisphenol A, as a Mn(iii)–chelate complex, in milk samples by ultrasound assisted-cloud point extraction/flame atomic absorption spectrometry
A new indirect method was developed for the selective determination of bisphenol A. The reproducibility was improved using polyvinyl alcohol. A detection limit of 0.23 μg L−1 was obtained in a linear range of 0.8–130 μg L−1.
- 15 October 2021
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 19 (5) , 1669-1688
A magnetic nanocomposite based on amine-functionalized pH-sensitive functional poly(styrene-co-maleic anhydride) copolymer for selective extraction, pre-concentration and determination of sub-trace Ag+ and Cu2+ ions from edible vegetable oils by a combination of spectrophotometry and ultrasound-assisted cloud point extraction
- 15 October 2021
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 19 (5) , 1669-1688
A magnetic nanocomposite based on amine-functionalized pH-sensitive functional poly(styrene-co-maleic anhydride) copolymer for selective extraction, pre-concentration and determination of sub-trace Ag+ and Cu2+ ions from edible vegetable oils by a combination of spectrophotometry and ultrasound-assisted cloud point extraction
- 8 September 2020
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 37 (11) , 1811-1830
Coupling of ion pair ultrasound assisted-cloud point extraction to microvolume UV-Vis spectrophotometry for speciation analysis of ionic NO2-,NO3- and total NO2-/NO3- without and with reduction in the selected beverage and food matrices
This study proposes a simple, low-cost, easy to use, fast, accurate and reliable ultrasound assisted-cloud point extraction (UA-CPE) method for the enrichment and speciation analysis of low levels of ionic NO2 −, NO3 − and total NO2 −/NO3 − without and with reduction by micro-volume UV-vis spectrophotometry. The method relies on the reaction of NO2 − with excess iodide at pH 5.5 to form triiodide, and then the extraction of the oxidation product formed by charge transfer into micellar phase of Triton X-114 using cationic redox-sensitive phenazine dye, neutral red (NRH+) as ion-pairing in absence and presence of 1.5 mL of 1.0 × 10−3 mol L−1 Br− ions. The main variables affecting extraction efficiency were studied and optimised in detail. Under the optimal conditions, the calibration curves in solvent were linear over the ranges of 5–100 and 100–1280 µg L−1 with a detection limit of 1.32 µg L−1 while the matrix-matched calibration curves prepared from sample extracts were linear over the ranges of 5–125 and 125–1350 µg L−1 with a detection limit ranging from 1.15 to 1.50 µg L−1 for sample matrices. From pre-concentration of 25-mL sample, pre-concentration and sensitivity enhancement folds of 62.5 and 76.5 were obtained. The accuracy/precision studies after spiking were performed, and observed to be in range of 96.5–99.6% and 1.9–5.7% (15, 75 and 250 µg L−1, n: 5). The speciation analysis of ionic NO2 −, NO3 − and total NO2 −/NO3 − was performed from artificially prepared binary mixtures after reduction with a mixture of Zn and NaCl in acidic media. The free NO3 − contents of samples were calculated from difference between free NO2 − and total NO2 −/NO3 − contents. After validation by analysis of a certified sample, the method was successfully applied to the speciation analysis of the beverage, cured meat, vegetable and milk samples. After pre-treatment with two sample preparation steps, it was observed that the results obtained were also compatible with each other, statistically validating the method.
- 8 September 2020
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 37 (11) , 1811-1830
Coupling of ion pair ultrasound assisted-cloud point extraction to microvolume UV-Vis spectrophotometry for speciation analysis of ionic NO2-,NO3- and total NO2-/NO3- without and with reduction in the selected beverage and food matrices
This study proposes a simple, low-cost, easy to use, fast, accurate and reliable ultrasound assisted-cloud point extraction (UA-CPE) method for the enrichment and speciation analysis of low levels of ionic NO2 −, NO3 − and total NO2 −/NO3 − without and with reduction by micro-volume UV-vis spectrophotometry. The method relies on the reaction of NO2 − with excess iodide at pH 5.5 to form triiodide, and then the extraction of the oxidation product formed by charge transfer into micellar phase of Triton X-114 using cationic redox-sensitive phenazine dye, neutral red (NRH+) as ion-pairing in absence and presence of 1.5 mL of 1.0 × 10−3 mol L−1 Br− ions. The main variables affecting extraction efficiency were studied and optimised in detail. Under the optimal conditions, the calibration curves in solvent were linear over the ranges of 5–100 and 100–1280 µg L−1 with a detection limit of 1.32 µg L−1 while the matrix-matched calibration curves prepared from sample extracts were linear over the ranges of 5–125 and 125–1350 µg L−1 with a detection limit ranging from 1.15 to 1.50 µg L−1 for sample matrices. From pre-concentration of 25-mL sample, pre-concentration and sensitivity enhancement folds of 62.5 and 76.5 were obtained. The accuracy/precision studies after spiking were performed, and observed to be in range of 96.5–99.6% and 1.9–5.7% (15, 75 and 250 µg L−1, n: 5). The speciation analysis of ionic NO2 −, NO3 − and total NO2 −/NO3 − was performed from artificially prepared binary mixtures after reduction with a mixture of Zn and NaCl in acidic media. The free NO3 − contents of samples were calculated from difference between free NO2 − and total NO2 −/NO3 − contents. After validation by analysis of a certified sample, the method was successfully applied to the speciation analysis of the beverage, cured meat, vegetable and milk samples. After pre-treatment with two sample preparation steps, it was observed that the results obtained were also compatible with each other, statistically validating the method.