H. Bayram Zengin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
H. Bayram Zengin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ramazan Gürkan
Department of Chemistry, Faculty of Sciences, Cumhuriyet University, Sivas, Turkey
3 shared publications A. Boztuğ
1 shared publicationAli Boztuğ
Department of Chemistry, Cumhuriyet University, 58140 Sivas, Turkey
1 shared publicationE. Yılmaz
1 shared publicationR. Gürkan
Cumhuriyet University
1 shared publicationSatılmış Basan
Faculty of Engineering, Gazi University, Çorum, Turkey
1 shared publication
Latest Publications
- Open Access
- 30 September 2024
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 45 (3) , 530-536
Effect of the Size of the Molecular Mass of Some Amine Groups Modified to Maleic anhydride-alt-1-Octadecene Copolymer on Thermal Stability
In this study, 1-octadecene-alt-maleic anhydride (OC-MA) copolymer was synthesized by radical polymerization method. The synthesized copolymer was first time modified with ammonia, methylamine, aniline and hexamethylenediamine reagents in acetone environment. The modified amidic acid derivatives were divided into two parts as quantity. One of these amounts was dried as an amidic acid derivative, and the other was imidized in dimethylformamide environment with constant stirring at 150 °C for 5 hours. Structural characterizations of the obtained samples were determined from the FTIR spectra. Thermal stability was compared from Thermogravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC) curves. It was established that the modified copolymers were thermally more stable than that of the original OC-MA copolymer. However, it was observed that the size of the molar masses of the reagents participating in the modification reactions showed linear or parabolic increases according to thermal parameter temperature of the decomposition reaction obtained from the TGA and DSC curves.
- 30 September 2024
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 45 (3) , 530-536
Open AccessEffect of the Size of the Molecular Mass of Some Amine Groups Modified to Maleic anhydride-alt-1-Octadecene Copolymer on Thermal Stability
In this study, 1-octadecene-alt-maleic anhydride (OC-MA) copolymer was synthesized by radical polymerization method. The synthesized copolymer was first time modified with ammonia, methylamine, aniline and hexamethylenediamine reagents in acetone environment. The modified amidic acid derivatives were divided into two parts as quantity. One of these amounts was dried as an amidic acid derivative, and the other was imidized in dimethylformamide environment with constant stirring at 150 °C for 5 hours. Structural characterizations of the obtained samples were determined from the FTIR spectra. Thermal stability was compared from Thermogravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC) curves. It was established that the modified copolymers were thermally more stable than that of the original OC-MA copolymer. However, it was observed that the size of the molar masses of the reagents participating in the modification reactions showed linear or parabolic increases according to thermal parameter temperature of the decomposition reaction obtained from the TGA and DSC curves.
- 9 January 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (18) , 7046-7066
Application of ultrasound assisted-cloud point extraction coupled with spectrophotometry for the selective extraction/pre-concentration of low levels of inorganic Hg (as Hg 2 2+ /Hg 2+ ) from liquid matrices
This study presents the analytical characterisation of a low-cost, selective and sensitive method for inorganic Hg (as Hg22+/Hg2+) determination in liquid matrices based on spectrophotometry. The novelty of the study lies in combining the pre-concentration of i-Hg with spectrophotometry after chelation with the 2-aminobenzimidazole modified amidic copolymer to increase the selectivity and sensitivity of the method. The method involves ultrasonic extraction of the samples in a dilute acid mixture of HClO4-HCl-CH3COOH and mixture of Cu(II)-oxalic acid-KCl adjusted to pH 5.0 in parallel, pre-con centration using UA-CPE process on modified amide copolymer, and absorbance measurement at 332 nm using a micro-volume UV-spectrophotometer. The figures of merit were discussed in relation with the demands in the national/international regulations and standards on the determination of toxic i-Hg in water intended for human consumption. After a pre-concentration of 62.5-fold, the limits of detection and quantification (LODs, LOQs) were 0.24 and 0.22 μg L−1 allowing the use of the method for i-Hg determination in liquid matrices such as cold-/hot-spring waters, plain soda, bottled drinking waters, and carbonated soft drinks. For concentrations of Hg22+, Hg2+ and total Hg in the range of −1, the precision was 3.3–8.3%, below and little above the maximum limits of 1.0 µg L−1 set in the mentioned legislation. The recovery of 92–96.4% and the precision in the range of 4.1–5.4% in the analysis of two certified waters were found to be satisfactory, so as to validate the method. The method developed is cost-effective and enables us to achieve i-Hg determination in liquid matrices complying with European legislation. The system has a good potential for the future and analytical perspectives.
- 9 January 2023
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (18) , 7046-7066
Application of ultrasound assisted-cloud point extraction coupled with spectrophotometry for the selective extraction/pre-concentration of low levels of inorganic Hg (as Hg 2 2+ /Hg 2+ ) from liquid matrices
This study presents the analytical characterisation of a low-cost, selective and sensitive method for inorganic Hg (as Hg22+/Hg2+) determination in liquid matrices based on spectrophotometry. The novelty of the study lies in combining the pre-concentration of i-Hg with spectrophotometry after chelation with the 2-aminobenzimidazole modified amidic copolymer to increase the selectivity and sensitivity of the method. The method involves ultrasonic extraction of the samples in a dilute acid mixture of HClO4-HCl-CH3COOH and mixture of Cu(II)-oxalic acid-KCl adjusted to pH 5.0 in parallel, pre-con centration using UA-CPE process on modified amide copolymer, and absorbance measurement at 332 nm using a micro-volume UV-spectrophotometer. The figures of merit were discussed in relation with the demands in the national/international regulations and standards on the determination of toxic i-Hg in water intended for human consumption. After a pre-concentration of 62.5-fold, the limits of detection and quantification (LODs, LOQs) were 0.24 and 0.22 μg L−1 allowing the use of the method for i-Hg determination in liquid matrices such as cold-/hot-spring waters, plain soda, bottled drinking waters, and carbonated soft drinks. For concentrations of Hg22+, Hg2+ and total Hg in the range of −1, the precision was 3.3–8.3%, below and little above the maximum limits of 1.0 µg L−1 set in the mentioned legislation. The recovery of 92–96.4% and the precision in the range of 4.1–5.4% in the analysis of two certified waters were found to be satisfactory, so as to validate the method. The method developed is cost-effective and enables us to achieve i-Hg determination in liquid matrices complying with European legislation. The system has a good potential for the future and analytical perspectives.
- 22 September 2022
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 115, 104931
Novel amide- and imide-co-polymers modified with sulfathiazole as efficient chelator for selective extraction, pre-concentration and determination of trace inorganic antimony (as Sb(III)) from edible vegetable oils by ultrasound assisted-cloud point extraction coupled to micro-volume UV-spectrophotometry
- 22 September 2022
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 115, 104931
Novel amide- and imide-co-polymers modified with sulfathiazole as efficient chelator for selective extraction, pre-concentration and determination of trace inorganic antimony (as Sb(III)) from edible vegetable oils by ultrasound assisted-cloud point extraction coupled to micro-volume UV-spectrophotometry
- 14 November 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 101 (14) , 1978-2002
Use of new polymeric composites for preconcentration of trace Ag+ ions from the selected mushroom/vegetables by ultrasound-assisted cloud-point extraction coupled to microvolume UV-Vis spectrophotometry
The magnetic nano-composites based on the tris(hydroxymethlmethyl)aminomethane-modified maleic anhydride-co-styrene copolymers and Fe3O4 nano-particles were prepared as new potential chelating agents for ultrasound-assisted-cloud point extraction (UA-CPE) and pre-concentration of trace levels of Ag+ ions from aqueous solutions. The structures of the nano-composites were characterised via FT-IR, 1H-NMR and XRD analysis. After structural characterisation of composites, Ag+ ions were detected by micro-volume UV-vis spectrophotometry at 347 nm. The variables affecting complex formation and extraction efficiency for separation/pre-concentration of the Ag+ ions from various food matrices were evaluated and optimised in detail. Under the optimised conditions, the method shows a good sensitivity with linearity range from 10 to 350 µg L−1 and 4 to 160 µg L−1 for amidic and imidic composites, respectively, with a better correlation coefficient than 0.9825. The limits of detection, intra- and inter-day precision (as RSDs%) and recovery rates for six replicate determinations of Ag+ ions at levels of 25 and 100 μg L−1 were 4.28/1.21 μg L−1, 2.4–4.1% and 92–98% for the modified copolymers, respectively. The pre-concentration factor for Ag+ ion from pre-concentration of 35-mL sample was 70. A significant matrix effect was not observed for the triplicate measurements of 100 µg L−1 Ag+ in the presence of various interfering species below their maximum concentrations allowed in this method, for Ag+ ions. The accuracy of the method was confirmed by analysis of the two certified samples. The method was successfully applied to determine low levels of Ag+ ions in mushroom and vegetable samples, and satisfactory recoveries were obtained in the range of 91-97% with lower RSD than 5.1% for the spiked samples.
- 14 November 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 101 (14) , 1978-2002
Use of new polymeric composites for preconcentration of trace Ag+ ions from the selected mushroom/vegetables by ultrasound-assisted cloud-point extraction coupled to microvolume UV-Vis spectrophotometry
The magnetic nano-composites based on the tris(hydroxymethlmethyl)aminomethane-modified maleic anhydride-co-styrene copolymers and Fe3O4 nano-particles were prepared as new potential chelating agents for ultrasound-assisted-cloud point extraction (UA-CPE) and pre-concentration of trace levels of Ag+ ions from aqueous solutions. The structures of the nano-composites were characterised via FT-IR, 1H-NMR and XRD analysis. After structural characterisation of composites, Ag+ ions were detected by micro-volume UV-vis spectrophotometry at 347 nm. The variables affecting complex formation and extraction efficiency for separation/pre-concentration of the Ag+ ions from various food matrices were evaluated and optimised in detail. Under the optimised conditions, the method shows a good sensitivity with linearity range from 10 to 350 µg L−1 and 4 to 160 µg L−1 for amidic and imidic composites, respectively, with a better correlation coefficient than 0.9825. The limits of detection, intra- and inter-day precision (as RSDs%) and recovery rates for six replicate determinations of Ag+ ions at levels of 25 and 100 μg L−1 were 4.28/1.21 μg L−1, 2.4–4.1% and 92–98% for the modified copolymers, respectively. The pre-concentration factor for Ag+ ion from pre-concentration of 35-mL sample was 70. A significant matrix effect was not observed for the triplicate measurements of 100 µg L−1 Ag+ in the presence of various interfering species below their maximum concentrations allowed in this method, for Ag+ ions. The accuracy of the method was confirmed by analysis of the two certified samples. The method was successfully applied to determine low levels of Ag+ ions in mushroom and vegetable samples, and satisfactory recoveries were obtained in the range of 91-97% with lower RSD than 5.1% for the spiked samples.
- 3 January 2019
- Published by Springer Nature in Biological Trace Element Research
- Vol. 191 (1) , 254-268
Use of 2-Hydrazinobenzothiazole-Modified Copolymer(s) as Potential Chelating Agent for Sensitive and Selective Determination of Low Levels of Mercury in Seafood by Ultrasound-Assisted Cloud-Point Extraction Combined with Spectrophotometry
In this study, a new method was developed for the pre-concentration of trace mercury from seafood samples prior to analysis by spectrophotometry. The method is based on the complexation between 2-hydrazinobenzothiazole (2-HBT)-modified copolymer(s) and Hg(II) in the presence of an ionic surfactant, cetyltrimethylammonium bromide (CTAB), as sensitivity enhancer at pH 4.5 and the extraction of the complex into the surfactant-rich phase of polyethylene glycol tert-octylphenyl ether (Triton X-114) as the extractant. The variables affecting extraction efficiency were evaluated and optimized. Due to the observation that the modified copolymers are 2.5-fold more sensitive and selective to the Hg2+ ions than the CH3Hg+, the amounts of free Hg2+ and total Hg were determined at 325 nm by spectrophotometric detection of free Hg2+ and total Hg in the pre-treated and extracted fish samples using dilute acid mixture containing Triton X-114 and K2Cr2O7, before and after oxidation of CH3Hg+ to Hg2+ with mixture of KBr and KBrO3 in the acidic media. The amount of CH3Hg+ was calculated from the difference between total Hg and free Hg2+ amounts. The accuracy was tested by analysis of two certified samples. The results were statistically in good agreement with the certified values, and the precision was lower than 6.4%. The limits of detection were 1.40 (1.58) and 1.91 (2.11) μg L−1 for Hg2+ from the two calibration solutions spiked before the pre-treatment, respectively. It has been observed that there is no significant matrix effect by comparison of slopes of the calibration curves. The method was applied to seafood samples for speciation analysis of free Hg2+ and CH3Hg+. In terms of speciation, while total Hg is detected in the range of 12.6–143.8 μg kg−1, the distribution of mercury in seafood was in the range of 7.4–53.3 μg kg−1 for CH3Hg+ and in 8.3–90.5 μg kg−1 for free Hg2+.
- 3 January 2019
- Published by Springer Nature in Biological Trace Element Research
- Vol. 191 (1) , 254-268
Use of 2-Hydrazinobenzothiazole-Modified Copolymer(s) as Potential Chelating Agent for Sensitive and Selective Determination of Low Levels of Mercury in Seafood by Ultrasound-Assisted Cloud-Point Extraction Combined with Spectrophotometry
In this study, a new method was developed for the pre-concentration of trace mercury from seafood samples prior to analysis by spectrophotometry. The method is based on the complexation between 2-hydrazinobenzothiazole (2-HBT)-modified copolymer(s) and Hg(II) in the presence of an ionic surfactant, cetyltrimethylammonium bromide (CTAB), as sensitivity enhancer at pH 4.5 and the extraction of the complex into the surfactant-rich phase of polyethylene glycol tert-octylphenyl ether (Triton X-114) as the extractant. The variables affecting extraction efficiency were evaluated and optimized. Due to the observation that the modified copolymers are 2.5-fold more sensitive and selective to the Hg2+ ions than the CH3Hg+, the amounts of free Hg2+ and total Hg were determined at 325 nm by spectrophotometric detection of free Hg2+ and total Hg in the pre-treated and extracted fish samples using dilute acid mixture containing Triton X-114 and K2Cr2O7, before and after oxidation of CH3Hg+ to Hg2+ with mixture of KBr and KBrO3 in the acidic media. The amount of CH3Hg+ was calculated from the difference between total Hg and free Hg2+ amounts. The accuracy was tested by analysis of two certified samples. The results were statistically in good agreement with the certified values, and the precision was lower than 6.4%. The limits of detection were 1.40 (1.58) and 1.91 (2.11) μg L−1 for Hg2+ from the two calibration solutions spiked before the pre-treatment, respectively. It has been observed that there is no significant matrix effect by comparison of slopes of the calibration curves. The method was applied to seafood samples for speciation analysis of free Hg2+ and CH3Hg+. In terms of speciation, while total Hg is detected in the range of 12.6–143.8 μg kg−1, the distribution of mercury in seafood was in the range of 7.4–53.3 μg kg−1 for CH3Hg+ and in 8.3–90.5 μg kg−1 for free Hg2+.
- Open Access
- 30 September 2017
- Published by Cumhuriyet University Sciences Journal in Cumhuriyet Science Journal
- Vol. 38 (3) , 581-587
Adsorption of Uranyl Ions in Aqueous Solutions of Maleic Anhydride-alt-Styrene Copolymers
En tr In this study, Maleic anhydride-alt-styrene (MA/S) copolymer was synthesized in benzene solution with an initiator such as azobisisobutyronitrile by free radical copolymerization. Anhydride units are seen in resulting copolymer and anhydride units are active. By considering activities of anhydride units, adsorptions of uranyl ions in uranyl nitrate solutions with spectrophotometric method was investigated uranyl ion concentration, at different temperature and dimension of MA/S copolymer. In the adsorption investigation, Langmuır (L) type was suggested according to Giles classification system. Binding parameters such as equilibrium constant (K), monolayer coverage (n) and thermodynamic parameters such as heat of adsorption (ΔH), free energy of adsorption (ΔG) and entropy of adsorption (ΔS) for (MA/S) copolymer were calculated by using van’t Hoff and Klotz linearization methods. As a result, it can be stated that MA/S copolymer can be used as a good absorbent for uranyl from removal from waste water. Bu çalışmada, Maleik anhidrid–ard–stiren (MA/S) kopolimerleri benzen çözücüsünde azobisizobütironitril başlatıcısı ile serbest radikal polimerleşmesi ile sentezlenmiştir. Elde edilen kopolimerin yapısında bulunan anhidrit birimleri çok reaktiftir. Anhidrit birimlerinin reaktifliği göz önünde bulundurularak, uranil iyonlarının kopolimerdeki adsorpsiyonuna uranil iyonunun başlangıç derişimi, sıcaklık ve tanecik boyutunun etkisi araştırılmıştır. Başlangıç ve dengedeki uranil iyonları derişimi spektrofotometrik yöntemle izlenmiştir. Adsorpsiyon çalışmasında, Giles sınıflandırma sistemine Langmuir (L) türü adsorpsiyon bulunmuştur. Klotz eşitliği yardımıyla tek tabaka kaplanma kapasitesi (n), denge sabiti (K) gibi adsorpsiyon parametreleri, van’t Hoff eşitliği ile de serbest enerji (ΔG), entalpi (ΔH) ve entropi (ΔS) gibi termodinamik parametrelerde hesaplanmıştır. Sonuç olarak MA/S kopolimerlerinin atık sulardan uranil gideriminde iyi bir adsorbent olarak kullanılabileceği söylenebilir.
- 30 September 2017
- Published by Cumhuriyet University Sciences Journal in Cumhuriyet Science Journal
- Vol. 38 (3) , 581-587
Open AccessAdsorption of Uranyl Ions in Aqueous Solutions of Maleic Anhydride-alt-Styrene Copolymers
En tr In this study, Maleic anhydride-alt-styrene (MA/S) copolymer was synthesized in benzene solution with an initiator such as azobisisobutyronitrile by free radical copolymerization. Anhydride units are seen in resulting copolymer and anhydride units are active. By considering activities of anhydride units, adsorptions of uranyl ions in uranyl nitrate solutions with spectrophotometric method was investigated uranyl ion concentration, at different temperature and dimension of MA/S copolymer. In the adsorption investigation, Langmuır (L) type was suggested according to Giles classification system. Binding parameters such as equilibrium constant (K), monolayer coverage (n) and thermodynamic parameters such as heat of adsorption (ΔH), free energy of adsorption (ΔG) and entropy of adsorption (ΔS) for (MA/S) copolymer were calculated by using van’t Hoff and Klotz linearization methods. As a result, it can be stated that MA/S copolymer can be used as a good absorbent for uranyl from removal from waste water. Bu çalışmada, Maleik anhidrid–ard–stiren (MA/S) kopolimerleri benzen çözücüsünde azobisizobütironitril başlatıcısı ile serbest radikal polimerleşmesi ile sentezlenmiştir. Elde edilen kopolimerin yapısında bulunan anhidrit birimleri çok reaktiftir. Anhidrit birimlerinin reaktifliği göz önünde bulundurularak, uranil iyonlarının kopolimerdeki adsorpsiyonuna uranil iyonunun başlangıç derişimi, sıcaklık ve tanecik boyutunun etkisi araştırılmıştır. Başlangıç ve dengedeki uranil iyonları derişimi spektrofotometrik yöntemle izlenmiştir. Adsorpsiyon çalışmasında, Giles sınıflandırma sistemine Langmuir (L) türü adsorpsiyon bulunmuştur. Klotz eşitliği yardımıyla tek tabaka kaplanma kapasitesi (n), denge sabiti (K) gibi adsorpsiyon parametreleri, van’t Hoff eşitliği ile de serbest enerji (ΔG), entalpi (ΔH) ve entropi (ΔS) gibi termodinamik parametrelerde hesaplanmıştır. Sonuç olarak MA/S kopolimerlerinin atık sulardan uranil gideriminde iyi bir adsorbent olarak kullanılabileceği söylenebilir.
- 1 June 2008
- Published by Taylor & Francis in Materials Research Innovations
- Vol. 12 (2) , 90-93
Chemical modification and thermal characterisation of poly(allylpropionate-alt-maleic anhydride) copolymer modified by hexamethylenediamine
- 1 June 2008
- Published by Taylor & Francis in Materials Research Innovations
- Vol. 12 (2) , 90-93
Chemical modification and thermal characterisation of poly(allylpropionate-alt-maleic anhydride) copolymer modified by hexamethylenediamine
- 27 May 2006
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 101 (4) , 2250-2254
Synthesis and comparative study of thermal stabilities of the imidization of some maleic anhydride copolymers
In the present study, first, maleic anhydride‐styrene (MA‐St), maleic anhydride‐allyl phenyl ether (MA‐APhE), maleic anhydride‐heptene‐1(MA‐Hp), and maleic anhydride‐allyl propionate (MA‐AP) copolymers have been synthesized in different solvents in the presence of azobisisobutyronitrile (AIBN) at 70°C. Then, these four copolymers have been reacted with aniline at 60°C in N,N‐dimethyl formamide (DMF), and maleamidic acid derivatives of these copolymers have been synthesized. Next, they have been obtained from their maleimide derivatives by heating under vacuum at 150°C. All these polymers have been characterized by Fourier Transform infrared spectroscopy (FTIR) and investigated their thermal properties by using differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA) methods. The analyses results showed that thermal properties of maleimide derivatives of maleic anhydride copolymers changed as depend on the neighbor monomers of maleic anhydride. © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 101: 2250–2254, 2006
- 27 May 2006
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 101 (4) , 2250-2254
Synthesis and comparative study of thermal stabilities of the imidization of some maleic anhydride copolymers
In the present study, first, maleic anhydride‐styrene (MA‐St), maleic anhydride‐allyl phenyl ether (MA‐APhE), maleic anhydride‐heptene‐1(MA‐Hp), and maleic anhydride‐allyl propionate (MA‐AP) copolymers have been synthesized in different solvents in the presence of azobisisobutyronitrile (AIBN) at 70°C. Then, these four copolymers have been reacted with aniline at 60°C in N,N‐dimethyl formamide (DMF), and maleamidic acid derivatives of these copolymers have been synthesized. Next, they have been obtained from their maleimide derivatives by heating under vacuum at 150°C. All these polymers have been characterized by Fourier Transform infrared spectroscopy (FTIR) and investigated their thermal properties by using differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA) methods. The analyses results showed that thermal properties of maleimide derivatives of maleic anhydride copolymers changed as depend on the neighbor monomers of maleic anhydride. © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 101: 2250–2254, 2006