Elena Rota Kops
Research Subjects
Elena Rota Kops has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Christoph W. Lerche
Institute of Neuroscience and Medicine, Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Straße, Building 15.9, Office: 2001e, Jülich, 52428, GERMANY
9 shared publications - Nadim Joni Shah
Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
9 shared publications - Karl-Josef Langen
Department of Nuclear Medicine, RWTH Aachen University Clinic, Pauwelsstraße 30, Aachen, Germany
7 shared publications - Hans Herzog
Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich, Jülich, Germany
6 shared publications - Jörg Mauler
Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
5 shared publications - Lutz Tellmann
Forschungszentrum Jülich
5 shared publications
Latest Publications
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (6) , 618-631
Attenuation Correction of the Cerebellum in PET/MR Data
Attenuation correction (AC) is essential for achieving artefact-free PET/MR images. Many PET studies use the cerebellum as a reference region; therefore, AC methods should also be tested concerning their performance within the cerebellum. This study compares AC methods for PET/MR data, focusing on the cerebellum. Sixteen subjects underwent an 18FFDG scan in a 3T-MR-BrainPET insert and a whole-head CT scan on the same day. The CT scan data were transformed into individual CT-based attenuation maps (AMCT), while the MR images were used to derive AMs using three methods: Boston-MGH (AMMGH), London-UCL (AMUCL), and Juelich-Tx-template-based (AMTx-Juel). After reconstruction of the PET data with these four AMs, correlations, coefficients of determination, and relative errors (RErr) between the PET-AMCT and the other three PET-AMs were computed. The cerebellar RErr varied strongly between the three AC methods. The AMMGH method gave a RErr value of 3.85±5.03 %, the AMUCL method gave 6.00±4.54 %, and the AMTx-Juel gave 0.25±5.01 %. Our results demonstrate that radiotracer uptake quantification in the cerebellum is sensitive to the applied PET attenuation correction. This dependency should be especially considered in neuroreceptor studies where the cerebellum is the reference region.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (6) , 618-631
Attenuation Correction of the Cerebellum in PET/MR Data
Attenuation correction (AC) is essential for achieving artefact-free PET/MR images. Many PET studies use the cerebellum as a reference region; therefore, AC methods should also be tested concerning their performance within the cerebellum. This study compares AC methods for PET/MR data, focusing on the cerebellum. Sixteen subjects underwent an 18FFDG scan in a 3T-MR-BrainPET insert and a whole-head CT scan on the same day. The CT scan data were transformed into individual CT-based attenuation maps (AMCT), while the MR images were used to derive AMs using three methods: Boston-MGH (AMMGH), London-UCL (AMUCL), and Juelich-Tx-template-based (AMTx-Juel). After reconstruction of the PET data with these four AMs, correlations, coefficients of determination, and relative errors (RErr) between the PET-AMCT and the other three PET-AMs were computed. The cerebellar RErr varied strongly between the three AC methods. The AMMGH method gave a RErr value of 3.85±5.03 %, the AMUCL method gave 6.00±4.54 %, and the AMTx-Juel gave 0.25±5.01 %. Our results demonstrate that radiotracer uptake quantification in the cerebellum is sensitive to the applied PET attenuation correction. This dependency should be especially considered in neuroreceptor studies where the cerebellum is the reference region.
- Open Access
- 10 January 2022
- Published by Springer Nature in Translational Psychiatry
- Vol. 12 (1) , 1-10
mGluR5 binding changes during a mismatch negativity task in a multimodal protocol with [11C]ABP688 PET/MR-EEG
Currently, the metabotropic glutamate receptor 5 (mGluR5) is the subject of several lines of research in the context of neurology and is of high interest as a target for positron-emission tomography (PET). Here, we assessed the feasibility of using [11C]ABP688, a specific antagonist radiotracer for an allosteric site on the mGluR5, to evaluate changes in glutamatergic neurotransmission through a mismatch-negativity (MMN) task as a part of a simultaneous and synchronized multimodal PET/MR-EEG study. We analyzed the effect of MMN by comparing the changes in nondisplaceable binding potential (BPND) prior to (baseline) and during the task in 17 healthy subjects by applying a bolus/infusion protocol. Anatomical and functional regions were analyzed. A small change in BPND was observed in anatomical regions (posterior cingulate cortex and thalamus) and in a functional network (precuneus) after the start of the task. The effect size was quantified using Kendall’s W value and was 0.3. The motor cortex was used as a control region for the task and did not show any significant BPND changes. There was a significant ΔBPND between acquisition conditions. On average, the reductions in binding across the regions were - 8.6 ± 3.2% in anatomical and - 6.4 ± 0.5% in the functional network (p ≤ 0.001). Correlations between ΔBPND and EEG latency for both anatomical (p = 0.008) and functional (p = 0.022) regions were found. Exploratory analyses suggest that the MMN task played a role in the glutamatergic neurotransmission, and mGluR5 may be indirectly modulated by these changes.
- 10 January 2022
- Published by Springer Nature in Translational Psychiatry
- Vol. 12 (1) , 1-10
Open AccessmGluR5 binding changes during a mismatch negativity task in a multimodal protocol with [11C]ABP688 PET/MR-EEG
Currently, the metabotropic glutamate receptor 5 (mGluR5) is the subject of several lines of research in the context of neurology and is of high interest as a target for positron-emission tomography (PET). Here, we assessed the feasibility of using [11C]ABP688, a specific antagonist radiotracer for an allosteric site on the mGluR5, to evaluate changes in glutamatergic neurotransmission through a mismatch-negativity (MMN) task as a part of a simultaneous and synchronized multimodal PET/MR-EEG study. We analyzed the effect of MMN by comparing the changes in nondisplaceable binding potential (BPND) prior to (baseline) and during the task in 17 healthy subjects by applying a bolus/infusion protocol. Anatomical and functional regions were analyzed. A small change in BPND was observed in anatomical regions (posterior cingulate cortex and thalamus) and in a functional network (precuneus) after the start of the task. The effect size was quantified using Kendall’s W value and was 0.3. The motor cortex was used as a control region for the task and did not show any significant BPND changes. There was a significant ΔBPND between acquisition conditions. On average, the reductions in binding across the regions were - 8.6 ± 3.2% in anatomical and - 6.4 ± 0.5% in the functional network (p ≤ 0.001). Correlations between ΔBPND and EEG latency for both anatomical (p = 0.008) and functional (p = 0.022) regions were found. Exploratory analyses suggest that the MMN task played a role in the glutamatergic neurotransmission, and mGluR5 may be indirectly modulated by these changes.
- 3 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (5) , 1104-1113
A Novel J-Shape Antenna Array for Simultaneous MR-PET or MR-SPECT Imaging
Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept. The end-fed J-shape antenna is particularly adept for hybrid ultra-high field MR-PET/-SPECT applications as it enables all highly attenuating materials to be placed outside the imaging field-of-view. Furthermore, this unique configuration also provides advantages in stand-alone MR applications by reducing the amount of coupling between the cables and the antenna elements, and by lowering the potential specific absorption rate burden. The use of this new design was experimentally verified according to the important features for both ultra-high field MRI and the 511 keV transmission scan. The reconstructed attenuation maps evidently showed much lower attenuation (~15%) for the proposed array when compared to the conventional dipole antenna array since there were no high-density components. In MR, it was observed that the signal-to-noise ratio from the whole volume obtained using the proposed array was comparable to that acquired by the conventional array which was also in agreement with the simulation results. The unique feature, J-shape array, would enable simultaneous MR-PET/-SPECT experiments to be conducted without unduly compromising any aspects of system performance and image quality compared to the stand-alone instrumentation.
- 3 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (5) , 1104-1113
A Novel J-Shape Antenna Array for Simultaneous MR-PET or MR-SPECT Imaging
Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept. The end-fed J-shape antenna is particularly adept for hybrid ultra-high field MR-PET/-SPECT applications as it enables all highly attenuating materials to be placed outside the imaging field-of-view. Furthermore, this unique configuration also provides advantages in stand-alone MR applications by reducing the amount of coupling between the cables and the antenna elements, and by lowering the potential specific absorption rate burden. The use of this new design was experimentally verified according to the important features for both ultra-high field MRI and the 511 keV transmission scan. The reconstructed attenuation maps evidently showed much lower attenuation (~15%) for the proposed array when compared to the conventional dipole antenna array since there were no high-density components. In MR, it was observed that the signal-to-noise ratio from the whole volume obtained using the proposed array was comparable to that acquired by the conventional array which was also in agreement with the simulation results. The unique feature, J-shape array, would enable simultaneous MR-PET/-SPECT experiments to be conducted without unduly compromising any aspects of system performance and image quality compared to the stand-alone instrumentation.
- 18 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (7) , 1852-1862
A Linearized Fit Model for Robust Shape Parameterization of FET-PET TACs
The kinetic analysis of 18F-FET time-activity curves (TAC) can provide valuable diagnostic information in glioma patients. The analysis is most often limited to the average TAC over a large tissue volume and is normally assessed by visual inspection or by evaluating the time-to-peak and linear slope during the late uptake phase. Here, we derived and validated a linearized model for TACs of 18F-FET in dynamic PET scans. Emphasis was put on the robustness of the numerical parameters and how reliably automatic voxel-wise analysis of TAC kinetics was possible. The diagnostic performance of the extracted shape parameters for the discrimination between isocitrate dehydrogenase (IDH) wildtype (wt) and IDH-mutant (mut) glioma was assessed by receiver-operating characteristic in a group of 33 adult glioma patients. A high agreement between the adjusted model and measured TACs could be obtained and relative, estimated parameter uncertainties were small. The best differentiation between IDH-wt and IDH-mut gliomas was achieved with the linearized model fitted to the averaged TAC values from dynamic FET PET data in the time interval 4-50 min p.i.. When limiting the acquisition time to 20-40 min p.i., classification accuracy was only slightly lower (-3%) and was comparable to classification based on linear fits in this time interval. Voxel-wise fitting was possible within a computation time ≈ 1 min per image slice. Parameter uncertainties smaller than 80% for all fits with the linearized model were achieved. The agreement of best-fit parameters when comparing voxel-wise fits and fits of averaged TACs was very high (p<0.001).
- 18 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (7) , 1852-1862
A Linearized Fit Model for Robust Shape Parameterization of FET-PET TACs
The kinetic analysis of 18F-FET time-activity curves (TAC) can provide valuable diagnostic information in glioma patients. The analysis is most often limited to the average TAC over a large tissue volume and is normally assessed by visual inspection or by evaluating the time-to-peak and linear slope during the late uptake phase. Here, we derived and validated a linearized model for TACs of 18F-FET in dynamic PET scans. Emphasis was put on the robustness of the numerical parameters and how reliably automatic voxel-wise analysis of TAC kinetics was possible. The diagnostic performance of the extracted shape parameters for the discrimination between isocitrate dehydrogenase (IDH) wildtype (wt) and IDH-mutant (mut) glioma was assessed by receiver-operating characteristic in a group of 33 adult glioma patients. A high agreement between the adjusted model and measured TACs could be obtained and relative, estimated parameter uncertainties were small. The best differentiation between IDH-wt and IDH-mut gliomas was achieved with the linearized model fitted to the averaged TAC values from dynamic FET PET data in the time interval 4-50 min p.i.. When limiting the acquisition time to 20-40 min p.i., classification accuracy was only slightly lower (-3%) and was comparable to classification based on linear fits in this time interval. Voxel-wise fitting was possible within a computation time ≈ 1 min per image slice. Parameter uncertainties smaller than 80% for all fits with the linearized model were achieved. The agreement of best-fit parameters when comparing voxel-wise fits and fits of averaged TACs was very high (p<0.001).
- Open Access
Excitatory-Inhibitory Balance within EEG Microstates and Resting-state fMRI Networks: Assessed via Simultaneous PET-MR-EEG Imaging
The symbiosis of neuronal activities and glucose energy metabolism is reflected in the generation of functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) signals. However, their association with the balance between neuronal excitation and inhibition (E/I-B), which is closely related to the activities of glutamate and GABA (γ -aminobutyric acid) and the receptor availability (RA) of GABA A and mGluR5, remains unexplored. This study investigates these associations during the resting state (RS) condition using simultaneously recorded PET/MR/EEG (trimodal) data. Glucose metabolism and neuroreceptor binding availability (non-displaceable binding potential (BP ND )) of GABA A and mGluR5 were found to be significantly higher and closely linked within core resting-state networks (RSNs). The neuronal generators of EEG microstates and the fMRI measures were most tightly associated with the BP ND of GABA A relative to mGluR5 BP ND and the glucose metabolism, emphasising a predominance of inhibitory processes within in the core RSNs at rest.
Open AccessExcitatory-Inhibitory Balance within EEG Microstates and Resting-state fMRI Networks: Assessed via Simultaneous PET-MR-EEG Imaging
The symbiosis of neuronal activities and glucose energy metabolism is reflected in the generation of functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) signals. However, their association with the balance between neuronal excitation and inhibition (E/I-B), which is closely related to the activities of glutamate and GABA (γ -aminobutyric acid) and the receptor availability (RA) of GABA A and mGluR5, remains unexplored. This study investigates these associations during the resting state (RS) condition using simultaneously recorded PET/MR/EEG (trimodal) data. Glucose metabolism and neuroreceptor binding availability (non-displaceable binding potential (BP ND )) of GABA A and mGluR5 were found to be significantly higher and closely linked within core resting-state networks (RSNs). The neuronal generators of EEG microstates and the fMRI measures were most tightly associated with the BP ND of GABA A relative to mGluR5 BP ND and the glucose metabolism, emphasising a predominance of inhibitory processes within in the core RSNs at rest.
- Open Access
- 9 March 2020
- Published by Wiley in Human Brain Mapping
- Vol. 41 (10) , 2762-2781
mGluR5 receptor availability is associated with lower levels of negative symptoms and better cognition in male patients with chronic schizophrenia
Consistent findings postulate disturbed glutamatergic function (more specifically a hypofunction of the ionotropic NMDA receptors) as an important pathophysiologic mechanism in schizophrenia. However, the role of the metabotropic glutamatergic receptors type 5 (mGluR5) in this disease remains unclear. In this study, we investigated their significance (using [11C]ABP688) for psychopathology and cognition in male patients with chronic schizophrenia and healthy controls. In the patient group, lower mGluR5 binding potential (BPND) values in the left temporal cortex and caudate were associated with higher general symptom levels (negative and depressive symptoms), lower levels of global functioning and worse cognitive performance. At the same time, in both groups, mGluR5 BPND were significantly lower in smokers (F[27,1] = 15.500; p = .001), but without significant differences between the groups. Our findings provide support for the concept that the impaired function of mGluR5 underlies the symptoms of schizophrenia. They further supply a new perspective on the complex relationship between tobacco addiction and schizophrenia by identifying glutamatergic neurotransmission—in particularly mGluR5—as a possible connection to a shared vulnerability.
- 9 March 2020
- Published by Wiley in Human Brain Mapping
- Vol. 41 (10) , 2762-2781
Open AccessmGluR5 receptor availability is associated with lower levels of negative symptoms and better cognition in male patients with chronic schizophrenia
Consistent findings postulate disturbed glutamatergic function (more specifically a hypofunction of the ionotropic NMDA receptors) as an important pathophysiologic mechanism in schizophrenia. However, the role of the metabotropic glutamatergic receptors type 5 (mGluR5) in this disease remains unclear. In this study, we investigated their significance (using [11C]ABP688) for psychopathology and cognition in male patients with chronic schizophrenia and healthy controls. In the patient group, lower mGluR5 binding potential (BPND) values in the left temporal cortex and caudate were associated with higher general symptom levels (negative and depressive symptoms), lower levels of global functioning and worse cognitive performance. At the same time, in both groups, mGluR5 BPND were significantly lower in smokers (F[27,1] = 15.500; p = .001), but without significant differences between the groups. Our findings provide support for the concept that the impaired function of mGluR5 underlies the symptoms of schizophrenia. They further supply a new perspective on the complex relationship between tobacco addiction and schizophrenia by identifying glutamatergic neurotransmission—in particularly mGluR5—as a possible connection to a shared vulnerability.
- 10 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (1) , 140-151
Scatter Correction Based on GPU-Accelerated Full Monte Carlo Simulation for Brain PET/MRI
Accurate scatter correction is essential for qualitative and quantitative PET imaging. Up to now, scatter correction based on Monte Carlo simulation (MCS) has been recognized as the most accurate method of scatter correction for PET. However, the major disadvantage of MCS is its long computational time, which makes it unfeasible for clinical usage. Meanwhile, single scatter simulation (SSS) is the most widely used method for scatter correction. Nevertheless, SSS has the disadvantage of limited robustness for dynamic measurements and for the measurement of large objects. In this work, a newly developed implementation of MCS using graphics processing unit (GPU) acceleration is employed, allowing full MCS-based scatter correction in clinical 3D brain PET imaging. Starting from the generation of annihilation photons to their detection in the simulated PET scanner, all relevant physical interactions and transport phenomena of the photons were simulated on GPUs. This resulted in an expected distribution of scattered events, which was subsequently used to correct the measured emission data. The accuracy of the approach was validated with simulations using GATE (Geant4 Application for Tomography Emission), and its performance was compared to SSS. The comparison of the computation time between a GPU and a single-threaded CPU showed an acceleration factor of 776 for a voxelized brain phantom study. The speedup of the MCS implemented on the GPU represents a major step towards the application of the more accurate MCS-based scatter correction for PET imaging in clinical routine.
- 10 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (1) , 140-151
Scatter Correction Based on GPU-Accelerated Full Monte Carlo Simulation for Brain PET/MRI
Accurate scatter correction is essential for qualitative and quantitative PET imaging. Up to now, scatter correction based on Monte Carlo simulation (MCS) has been recognized as the most accurate method of scatter correction for PET. However, the major disadvantage of MCS is its long computational time, which makes it unfeasible for clinical usage. Meanwhile, single scatter simulation (SSS) is the most widely used method for scatter correction. Nevertheless, SSS has the disadvantage of limited robustness for dynamic measurements and for the measurement of large objects. In this work, a newly developed implementation of MCS using graphics processing unit (GPU) acceleration is employed, allowing full MCS-based scatter correction in clinical 3D brain PET imaging. Starting from the generation of annihilation photons to their detection in the simulated PET scanner, all relevant physical interactions and transport phenomena of the photons were simulated on GPUs. This resulted in an expected distribution of scattered events, which was subsequently used to correct the measured emission data. The accuracy of the approach was validated with simulations using GATE (Geant4 Application for Tomography Emission), and its performance was compared to SSS. The comparison of the computation time between a GPU and a single-threaded CPU showed an acceleration factor of 776 for a voxelized brain phantom study. The speedup of the MCS implemented on the GPU represents a major step towards the application of the more accurate MCS-based scatter correction for PET imaging in clinical routine.
- 27 October 2018
- Published by Wiley in Human Brain Mapping
- Vol. 42 (13) , 4122-4133
Comparison of EEG microstates with resting state fMRI and FDG‐PET measures in the default mode network via simultaneously recorded trimodal (PET/MR/EEG) data
Simultaneous trimodal positron emission tomography/magnetic resonance imaging/electroencephalography (PET/MRI/EEG) resting state (rs) brain data were acquired from 10 healthy male volunteers. The rs‐functional MRI (fMRI) metrics, such as regional homogeneity (ReHo), degree centrality (DC) and fractional amplitude of low‐frequency fluctuations (fALFFs), as well as 2‐[18F]fluoro‐2‐desoxy‐d‐glucose (FDG)‐PET standardised uptake value (SUV), were calculated and the measures were extracted from the default mode network (DMN) regions of the brain. Similarly, four microstates for each subject, showing the diverse functional states of the whole brain via topographical variations due to global field power (GFP), were estimated from artefact‐corrected EEG signals. In this exploratory analysis, the GFP of microstates was nonparametrically compared to rs‐fMRI metrics and FDG‐PET SUV measured in the DMN of the brain. The rs‐fMRI metrics (ReHO, fALFF) and FDG‐PET SUV did not show any significant correlations with any of the microstates. The DC metric showed a significant positive correlation with microstate C (rs = 0.73, p = .01). FDG‐PET SUVs indicate a trend for a negative correlation with microstates A, B and C. The positive correlation of microstate C with DC metrics suggests a functional relationship between cortical hubs in the frontal and occipital lobes. The results of this study suggest further exploration of this method in a larger sample and in patients with neuropsychiatric disorders. The aim of this exploratory pilot study is to lay the foundation for the development of such multimodal measures to be applied as biomarkers for diagnosis, disease staging, treatment response and monitoring of neuropsychiatric disorders.
- 27 October 2018
- Published by Wiley in Human Brain Mapping
- Vol. 42 (13) , 4122-4133
Comparison of EEG microstates with resting state fMRI and FDG‐PET measures in the default mode network via simultaneously recorded trimodal (PET/MR/EEG) data
Simultaneous trimodal positron emission tomography/magnetic resonance imaging/electroencephalography (PET/MRI/EEG) resting state (rs) brain data were acquired from 10 healthy male volunteers. The rs‐functional MRI (fMRI) metrics, such as regional homogeneity (ReHo), degree centrality (DC) and fractional amplitude of low‐frequency fluctuations (fALFFs), as well as 2‐[18F]fluoro‐2‐desoxy‐d‐glucose (FDG)‐PET standardised uptake value (SUV), were calculated and the measures were extracted from the default mode network (DMN) regions of the brain. Similarly, four microstates for each subject, showing the diverse functional states of the whole brain via topographical variations due to global field power (GFP), were estimated from artefact‐corrected EEG signals. In this exploratory analysis, the GFP of microstates was nonparametrically compared to rs‐fMRI metrics and FDG‐PET SUV measured in the DMN of the brain. The rs‐fMRI metrics (ReHO, fALFF) and FDG‐PET SUV did not show any significant correlations with any of the microstates. The DC metric showed a significant positive correlation with microstate C (rs = 0.73, p = .01). FDG‐PET SUVs indicate a trend for a negative correlation with microstates A, B and C. The positive correlation of microstate C with DC metrics suggests a functional relationship between cortical hubs in the frontal and occipital lobes. The results of this study suggest further exploration of this method in a larger sample and in patients with neuropsychiatric disorders. The aim of this exploratory pilot study is to lay the foundation for the development of such multimodal measures to be applied as biomarkers for diagnosis, disease staging, treatment response and monitoring of neuropsychiatric disorders.
- 9 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 352-362
The Jülich Experience With Simultaneous 3T MR-BrainPET: Methods and Technology
Building on the success of positron emission tomography (PET)/CT scanners, a hybrid imaging technology, combining PET with the versatile attributes of magnetic resonance imaging (MRI), has been in use for over ten years. At the Forschungszentrum Jülich, one of the four prototypes available worldwide, combining a commercial 3T MRI with a newly developed BrainPET insert, was installed in 2008, allowing simultaneous data acquisition with PET and MRI. Here, we report on our ten-year-long experience of the methods and technology developed through this paper with numerous patients and volunteers. In the course of our research, a number of different radiotracers, such as [ 18 F]Fluoroethyltyrosine, [ 11 C]Flumazenil, [ 11 C]Raclopride, and [ 15 O]H 2 O, have been applied while simultaneously measuring several different MR sequences. The PET data obtained with the BrainPET has demonstrated higher image quality and superior resolution capability compared to the stand-alone PET scanner, ECAT Exact HR+. Furthermore, the simultaneous acquisition of MR images alongside BrainPET scans, using different sequences, showed an excellent quality without any relevant artifacts and provided useful complementary information. Our experiences with the hybrid 3T MR-BrainPET indicate a promising basis for further developments of this unique technique, allowing simultaneous brain imaging in a clinical setting.
- 9 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 352-362
The Jülich Experience With Simultaneous 3T MR-BrainPET: Methods and Technology
Building on the success of positron emission tomography (PET)/CT scanners, a hybrid imaging technology, combining PET with the versatile attributes of magnetic resonance imaging (MRI), has been in use for over ten years. At the Forschungszentrum Jülich, one of the four prototypes available worldwide, combining a commercial 3T MRI with a newly developed BrainPET insert, was installed in 2008, allowing simultaneous data acquisition with PET and MRI. Here, we report on our ten-year-long experience of the methods and technology developed through this paper with numerous patients and volunteers. In the course of our research, a number of different radiotracers, such as [ 18 F]Fluoroethyltyrosine, [ 11 C]Flumazenil, [ 11 C]Raclopride, and [ 15 O]H 2 O, have been applied while simultaneously measuring several different MR sequences. The PET data obtained with the BrainPET has demonstrated higher image quality and superior resolution capability compared to the stand-alone PET scanner, ECAT Exact HR+. Furthermore, the simultaneous acquisition of MR images alongside BrainPET scans, using different sequences, showed an excellent quality without any relevant artifacts and provided useful complementary information. Our experiences with the hybrid 3T MR-BrainPET indicate a promising basis for further developments of this unique technique, allowing simultaneous brain imaging in a clinical setting.
- Open Access
Markov Random Field Segmentation of Brain MR Images
We describe a fully-automatic 3D-segmentation technique for brain MR images. Using Markov random fields the segmentation algorithm captures three important MR features, i.e. non-parametric distributions of tissue intensities, neighborhood correlations and signal inhomogeneities. Detailed simulations and real MR images demonstrate the performance of the segmentation algorithm. The impact of noise, inhomogeneity, smoothing and structure thickness is analyzed quantitatively. Even single echo MR images are well classified into gray matter, white matter, cerebrospinal fluid, scalp-bone and background. A simulated annealing and an iterated conditional modes implementation are presented. Keywords: Magnetic Resonance Imaging, Segmentation, Markov Random Fields
Open AccessMarkov Random Field Segmentation of Brain MR Images
We describe a fully-automatic 3D-segmentation technique for brain MR images. Using Markov random fields the segmentation algorithm captures three important MR features, i.e. non-parametric distributions of tissue intensities, neighborhood correlations and signal inhomogeneities. Detailed simulations and real MR images demonstrate the performance of the segmentation algorithm. The impact of noise, inhomogeneity, smoothing and structure thickness is analyzed quantitatively. Even single echo MR images are well classified into gray matter, white matter, cerebrospinal fluid, scalp-bone and background. A simulated annealing and an iterated conditional modes implementation are presented. Keywords: Magnetic Resonance Imaging, Segmentation, Markov Random Fields