The Jülich Experience With Simultaneous 3T MR-BrainPET: Methods and Technology
- 9 August 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (3) , 352-362
Abstract
Building on the success of positron emission tomography (PET)/CT scanners, a hybrid imaging technology, combining PET with the versatile attributes of magnetic resonance imaging (MRI), has been in use for over ten years. At the Forschungszentrum Jülich, one of the four prototypes available worldwide, combining a commercial 3T MRI with a newly developed BrainPET insert, was installed in 2008, allowing simultaneous data acquisition with PET and MRI. Here, we report on our ten-year-long experience of the methods and technology developed through this paper with numerous patients and volunteers. In the course of our research, a number of different radiotracers, such as [ 18 F]Fluoroethyltyrosine, [ 11 C]Flumazenil, [ 11 C]Raclopride, and [ 15 O]H 2 O, have been applied while simultaneously measuring several different MR sequences. The PET data obtained with the BrainPET has demonstrated higher image quality and superior resolution capability compared to the stand-alone PET scanner, ECAT Exact HR+. Furthermore, the simultaneous acquisition of MR images alongside BrainPET scans, using different sequences, showed an excellent quality without any relevant artifacts and provided useful complementary information. Our experiences with the hybrid 3T MR-BrainPET indicate a promising basis for further developments of this unique technique, allowing simultaneous brain imaging in a clinical setting.Keywords
Funding Information
- Internal Sources
This publication has 58 references indexed in Scilit:
- MR-Based PET Motion Correction Procedure for Simultaneous MR-PET Neuroimaging of Human BrainPLOS ONE, 2012
- Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contourAnnals of Nuclear Medicine, 2012
- High resolution BrainPET combined with simultaneous MRINuklearmedizin-Nuclear Medicine, 2011
- SPECT/CTJournal of Nuclear Medicine, 2008
- Partial volume corrected image derived input functions for dynamic PET brain studies: Methodology and validation for [11C]flumazenilNeuroImage, 2008
- Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scannerPhysics in Medicine & Biology, 2007
- Comprehensive processing, display and analysis for in vivo MR spectroscopic imagingNMR in Biomedicine, 2006
- Nonlinear spatial normalization using basis functionsHuman Brain Mapping, 1999
- Physical characteristics of the ECAT 953B/31: a new high resolution brain positron tomographIEEE Transactions on Medical Imaging, 1991
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1981