Michael C. Constantinou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael C. Constantinou has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Huseyin Cilsalar
Department of Civil Engineering, Yozgat Bozok University, Yozgat, Türkiye
2 shared publications - Hyun‐Myung Kim
Univ. at Buffalo, State Univ. of New York
2 shared publications - Sebastian Lopez Restrepo
Department of Civil Structural, and Environmental Engineering University at Buffalo State University of New York Buffalo New York USA
1 shared publication - Shoma Kitayama
Brunel University London
1 shared publication Y.Q. Chen
Department of Civil Engineering, State University of New York Buffalo, NY 14260, USA
1 shared publication
Latest Publications
- 15 November 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (2) , 562-582
Shake table testing of a seismic isolation system for lightweight structures
The implementation of seismic isolation in lightweight structures, such as houses, is limited, except for Japan, where nearly 5000 houses are seismically isolated with highly engineered systems. The use of such systems in countries of growing economies is prohibitive due to their cost, difficulties in locally fabricating components, and incompatibility with local construction practices. Previous studies on low‐cost isolation systems showed that isolation devices with rolling rather than sliding elements are more suitable for lightweight structures. A low‐cost isolation system based on a deformable rolling bearing developed at the University at Buffalo has simple components that can be easily manufactured, has a large displacement capacity, and features a fail‐safe mechanism. The bearing is composed of one flat and one concave concrete plate and a rubber rolling ball. This paper presents the results of shake table testing of half‐length scale versions of prototype houses and small bridges equipped with this deformable rolling isolation system in three‐directional seismic excitation. The results showed that deformable rolling bearings provide significant seismic protection of lightweight structures against strong ground motions, which in the testing reached a maximum peak ground velocity of 1.2 m/s in the test scale and a peak ground acceleration of 4 g in the horizontal direction and up to 1 g in the vertical direction. The isolation system was particularly effective in the horizontal direction, whereas it did not provide any vertical isolation. The tests included cases of extreme response, which included vertical impact within the bearing's components and uplift of the isolated structure.
- 15 November 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (2) , 562-582
Shake table testing of a seismic isolation system for lightweight structures
The implementation of seismic isolation in lightweight structures, such as houses, is limited, except for Japan, where nearly 5000 houses are seismically isolated with highly engineered systems. The use of such systems in countries of growing economies is prohibitive due to their cost, difficulties in locally fabricating components, and incompatibility with local construction practices. Previous studies on low‐cost isolation systems showed that isolation devices with rolling rather than sliding elements are more suitable for lightweight structures. A low‐cost isolation system based on a deformable rolling bearing developed at the University at Buffalo has simple components that can be easily manufactured, has a large displacement capacity, and features a fail‐safe mechanism. The bearing is composed of one flat and one concave concrete plate and a rubber rolling ball. This paper presents the results of shake table testing of half‐length scale versions of prototype houses and small bridges equipped with this deformable rolling isolation system in three‐directional seismic excitation. The results showed that deformable rolling bearings provide significant seismic protection of lightweight structures against strong ground motions, which in the testing reached a maximum peak ground velocity of 1.2 m/s in the test scale and a peak ground acceleration of 4 g in the horizontal direction and up to 1 g in the vertical direction. The isolation system was particularly effective in the horizontal direction, whereas it did not provide any vertical isolation. The tests included cases of extreme response, which included vertical impact within the bearing's components and uplift of the isolated structure.
- 26 July 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (12) , 3924-3937
Testing seismic isolators for the effect of maximum earthquake based on measure of cumulative energy
This paper presents results on what the conditions of testing for assessing the adequacy of seismic isolators in the maximum considered earthquake should be by utilizing an approach in which the cumulative dissipated energy history is used as the performance parameter. This test is what is described as Item 4 in section 17.8.2.2 of standard ASCE/SEI 7. The approach used follows the paradigm of another study in which the history of temperature at the sliding interfaces or in the bulk of the lead core of isolators was used. In conducting this work, many isolation systems (a total of 96 systems, single friction pendulum, triple friction pendulum, and lead‐rubber) were used, with isolator models capable of simulating the effects of heating on the strength of the isolators. The study utilized a large set of bi‐directional ground motions with short‐ and long‐duration characteristics (71 pairs of short‐ and long‐duration ground motions, 96 isolation systems, three seismic intensities, for a total of 40,896 ground motion pairs). The adequacy tests were designed to reproduce various percentile cumulative energy histories obtained in the response history analysis. The requirements of these tests are compared to the testing requirements obtained by the use of temperature history as the performance criterion, and the test currently prescribed as test item 4 of section 17.8.2.2 of standard ASCE/SEI‐7. The study shows that use of the cumulative dissipated energy as the performance criterion for designing tests to represent the effects of maximum earthquake results in onerous testing requirements. This is because the cumulative energy increases monotonically without accounting for fluctuations in the seismic ground motion intensity, unlike the history of temperature at the sliding interfaces or the lead core of isolators. Accordingly, tests designed using the temperature as the performance criterion are recommended for use in specifications for testing.
- 26 July 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (12) , 3924-3937
Testing seismic isolators for the effect of maximum earthquake based on measure of cumulative energy
This paper presents results on what the conditions of testing for assessing the adequacy of seismic isolators in the maximum considered earthquake should be by utilizing an approach in which the cumulative dissipated energy history is used as the performance parameter. This test is what is described as Item 4 in section 17.8.2.2 of standard ASCE/SEI 7. The approach used follows the paradigm of another study in which the history of temperature at the sliding interfaces or in the bulk of the lead core of isolators was used. In conducting this work, many isolation systems (a total of 96 systems, single friction pendulum, triple friction pendulum, and lead‐rubber) were used, with isolator models capable of simulating the effects of heating on the strength of the isolators. The study utilized a large set of bi‐directional ground motions with short‐ and long‐duration characteristics (71 pairs of short‐ and long‐duration ground motions, 96 isolation systems, three seismic intensities, for a total of 40,896 ground motion pairs). The adequacy tests were designed to reproduce various percentile cumulative energy histories obtained in the response history analysis. The requirements of these tests are compared to the testing requirements obtained by the use of temperature history as the performance criterion, and the test currently prescribed as test item 4 of section 17.8.2.2 of standard ASCE/SEI‐7. The study shows that use of the cumulative dissipated energy as the performance criterion for designing tests to represent the effects of maximum earthquake results in onerous testing requirements. This is because the cumulative energy increases monotonically without accounting for fluctuations in the seismic ground motion intensity, unlike the history of temperature at the sliding interfaces or the lead core of isolators. Accordingly, tests designed using the temperature as the performance criterion are recommended for use in specifications for testing.
- 22 December 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (3) , 1308-1325
Validity of models for frictional heating in sliding isolators
This paper investigates the validity of theories for the prediction of the temperature increase at the sliding interfaces of sliding isolators. The prevailing theory considers the isolator to be indefinite in depth and the heat flux generated at the sliding interface(s) to be infinite in extent. In reality, the depth is finite and small, and bounded by an insulating boundary, whereas the heat flux is bound by the circular area of contact. New theories are presented in which the restrictions of the past theory are relaxed. The resulting solutions have been implemented in program OpenSees for single and for triple friction pendulum isolators but are very complex and time‐consuming to be used in response history analysis with many isolators. Analysis of the response of sliding isolated structures with these models demonstrates that consideration of the finite depth of the isolators and of the limited extent of the heat flux does not have any important effects on the calculated isolator displacement demands in either short‐duration or long‐duration ground motions. It is shown that the finite depth has some effect on the peak temperature at the sliding interface and, more importantly, on the duration of the high temperature in long‐duration ground motions. This is of some importance in the use of these theories for the development of testing specifications for isolators with unusually thin end plates.
- 22 December 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (3) , 1308-1325
Validity of models for frictional heating in sliding isolators
This paper investigates the validity of theories for the prediction of the temperature increase at the sliding interfaces of sliding isolators. The prevailing theory considers the isolator to be indefinite in depth and the heat flux generated at the sliding interface(s) to be infinite in extent. In reality, the depth is finite and small, and bounded by an insulating boundary, whereas the heat flux is bound by the circular area of contact. New theories are presented in which the restrictions of the past theory are relaxed. The resulting solutions have been implemented in program OpenSees for single and for triple friction pendulum isolators but are very complex and time‐consuming to be used in response history analysis with many isolators. Analysis of the response of sliding isolated structures with these models demonstrates that consideration of the finite depth of the isolators and of the limited extent of the heat flux does not have any important effects on the calculated isolator displacement demands in either short‐duration or long‐duration ground motions. It is shown that the finite depth has some effect on the peak temperature at the sliding interface and, more importantly, on the duration of the high temperature in long‐duration ground motions. This is of some importance in the use of these theories for the development of testing specifications for isolators with unusually thin end plates.
- 23 November 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (4) , 1475-1498
Parametric study of seismic collapse performance of lightweight buildings with spherical deformable rolling isolation system
- 23 November 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (4) , 1475-1498
Parametric study of seismic collapse performance of lightweight buildings with spherical deformable rolling isolation system
- 26 April 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (7) , 4321-4345
Behavior of a spherical deformable rolling seismic isolator for lightweight residential construction
- 26 April 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (7) , 4321-4345
Behavior of a spherical deformable rolling seismic isolator for lightweight residential construction
- 8 January 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (5) , 2767-2786
Effect of displacement restraint on the collapse performance of seismically isolated buildings
- 8 January 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (5) , 2767-2786
Effect of displacement restraint on the collapse performance of seismically isolated buildings
- 1 January 1994
- Published by Springer Nature
- p. 199-208
Seismic Isolation Development in Europe
- 1 October 1990
- Published by Elsevier in Engineering Structures
- Vol. 12 (4) , 243-253
Use of Teflon sliders in a modification of the concept of soft first storey
- 1 October 1990
- Published by Elsevier in Engineering Structures
- Vol. 12 (4) , 243-253
Use of Teflon sliders in a modification of the concept of soft first storey