Huseyin Cilsalar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Huseyin Cilsalar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Michael C. Constantinou
Department of Civil Structural and Environmental Engineering University at Buffalo State University of New York Buffalo New York USA
2 shared publications Ayfer Erken
1 shared publicationCenk Cuma Cadir
1 shared publication- Shoma Kitayama
Brunel University London
1 shared publication - Zulkuf Kaya
Department of Civil Engineering, Erciyes University, Kayseri, Turkey
1 shared publication - Özgür Anil
Gazi University
1 shared publication
Latest Publications
- 14 July 2025
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 23 (11) , 4499-4524
Investigation of seismic collapse performance of RC frames with strengthened masonry infill walls under February 6, 2023 earthquakes in Türkiye
- 14 July 2025
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 23 (11) , 4499-4524
Investigation of seismic collapse performance of RC frames with strengthened masonry infill walls under February 6, 2023 earthquakes in Türkiye
- 30 June 2022
- Published by Golden Light Publishing in Journal of Structural Engineering & Applied Mechanics
- Vol. 5 (2) , 77-95
Comparative fire-following-earthquake performance of code-compliant low-rise base-isolated structures
Seismic base isolation is an effective way of protecting structures against seismic loads and is very effective in terms of both collapse mitigation of structures and protection of non-structural elements under severe ground shaking. In this study, the structural demand of base-isolated three- and four-story steel moment-resisting frames is determined in case of a fire event followed by an earthquake, and compared with the results of fixed-base frames, which have similar geometry, load, and seismic hazard for a location in California. Four compartments are selected as possible locations for fire events in each building, and beams and columns in those compartments are exposed to a representative temperature increase in time, which includes a cooling phase as well. Maximum, minimum, and residual axial force, and moment demands on elements of the fire compartments, and drift demand of structural frames on the first and second floor, where the fire is assumed to occur, are determined and compared. Results are given in terms of parameters of three-parameter log-normal distribution, hence fragility curves can be constructed for each response considered in the study. Seismic isolation is effective in reducing both maximum and residual drift demand of the frames, and axial force in the beam element for each compartment considered. Fixed-base frames have 20% more maximum axial load on beams. Beam and column elements in the four-story configuration are under relatively more moments in case of a fire, while the performance of three-story frames depends on the location of the assumed fire.
- 30 June 2022
- Published by Golden Light Publishing in Journal of Structural Engineering & Applied Mechanics
- Vol. 5 (2) , 77-95
Comparative fire-following-earthquake performance of code-compliant low-rise base-isolated structures
Seismic base isolation is an effective way of protecting structures against seismic loads and is very effective in terms of both collapse mitigation of structures and protection of non-structural elements under severe ground shaking. In this study, the structural demand of base-isolated three- and four-story steel moment-resisting frames is determined in case of a fire event followed by an earthquake, and compared with the results of fixed-base frames, which have similar geometry, load, and seismic hazard for a location in California. Four compartments are selected as possible locations for fire events in each building, and beams and columns in those compartments are exposed to a representative temperature increase in time, which includes a cooling phase as well. Maximum, minimum, and residual axial force, and moment demands on elements of the fire compartments, and drift demand of structural frames on the first and second floor, where the fire is assumed to occur, are determined and compared. Results are given in terms of parameters of three-parameter log-normal distribution, hence fragility curves can be constructed for each response considered in the study. Seismic isolation is effective in reducing both maximum and residual drift demand of the frames, and axial force in the beam element for each compartment considered. Fixed-base frames have 20% more maximum axial load on beams. Beam and column elements in the four-story configuration are under relatively more moments in case of a fire, while the performance of three-story frames depends on the location of the assumed fire.
- Open Access
- 16 November 2021
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 20 (2) , 1143-1168
Seismic loss assessment of seismically isolated buildings designed by the procedures of ASCE/SEI 7-16
This paper investigates the seismic loss assessment of seismically isolated and non-isolated buildings with steel moment or braced frames, designed by the seismic design standard of ASCE/SEI 7-16. The seismic loss is calculated from the damage to structural and non-structural components, as well as the demolition and the collapse of buildings. This study demonstrates that the expected annual losses for seismically isolated buildings are half or less than half of those calculated for non-isolated buildings. These losses depend on the types of seismic isolation systems and seismic force resisting systems used. Among the cases of isolated buildings studied in this paper, the most cost-effective systems are found to be the buildings designed by minimum strength requirement in ASCE/SEI 7-16 and with isolators which have displacement capacity 1.5 times larger than the minimum required in ASCE/SEI 7-16, in terms of expected annual losses. This study also compares the results obtained from different approaches of selection and scaling of ground motions. The following research finds that when Incremental Dynamic Analysis approach with far-field ground motion set in FEMA P695 is used, the computed expected total annual losses become doubled from the Conditional Spectra approach.
- 16 November 2021
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 20 (2) , 1143-1168
Open AccessSeismic loss assessment of seismically isolated buildings designed by the procedures of ASCE/SEI 7-16
This paper investigates the seismic loss assessment of seismically isolated and non-isolated buildings with steel moment or braced frames, designed by the seismic design standard of ASCE/SEI 7-16. The seismic loss is calculated from the damage to structural and non-structural components, as well as the demolition and the collapse of buildings. This study demonstrates that the expected annual losses for seismically isolated buildings are half or less than half of those calculated for non-isolated buildings. These losses depend on the types of seismic isolation systems and seismic force resisting systems used. Among the cases of isolated buildings studied in this paper, the most cost-effective systems are found to be the buildings designed by minimum strength requirement in ASCE/SEI 7-16 and with isolators which have displacement capacity 1.5 times larger than the minimum required in ASCE/SEI 7-16, in terms of expected annual losses. This study also compares the results obtained from different approaches of selection and scaling of ground motions. The following research finds that when Incremental Dynamic Analysis approach with far-field ground motion set in FEMA P695 is used, the computed expected total annual losses become doubled from the Conditional Spectra approach.
- 1 January 2021
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 140
Seismic performance evaluation of adjacent buildings with consideration of improved soil conditions
- 1 January 2021
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 140
Seismic performance evaluation of adjacent buildings with consideration of improved soil conditions
- 23 November 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (4) , 1475-1498
Parametric study of seismic collapse performance of lightweight buildings with spherical deformable rolling isolation system
- 23 November 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (4) , 1475-1498
Parametric study of seismic collapse performance of lightweight buildings with spherical deformable rolling isolation system
- 26 April 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (7) , 4321-4345
Behavior of a spherical deformable rolling seismic isolator for lightweight residential construction
- 26 April 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (7) , 4321-4345
Behavior of a spherical deformable rolling seismic isolator for lightweight residential construction