Thomas Sangild Sørensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Sangild Sørensen has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
- Kari Tanderup
Danish Center for Particle Therapy, Aarhus University Hospital, 8200 N Aarhus, Denmark
10 shared publications Jesper Mosegaard
The Alexandra Institute Ltd
8 shared publications- Michael Schacht Hansen
National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA
8 shared publications - Jesper Mosegaard
University of Aarhus, Denmark
6 shared publications - Tobias Schaeffter
Physikalisch‐Technische Bundesanstalt Berlin Germany
6 shared publications Allan Rasmusson
Department of Computer Science, Aarhus University, Aarhus, Denmark
5 shared publications
Latest Publications
- Open Access
- 22 March 2018
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 47 (5) , 20180013
An ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability
Objectives:To assess the impact of head motion artefacts and an automated artefact-correction system on CBCT image quality and interpretability for simulated diagnostic tasks.Methods:A partially dentate human skull was mounted on a robot simulating four types of head movement (antero-posterior translation, nodding, lateral rotation, and tremor), at three distances (0.75, 1.5, and 3 mm) based on two movement patterns (skull returning/not returning to the initial position). Two diagnostic tasks were simulated: dental implant planning and detection of a periapical lesion. Three CBCT units were used to examine the skull during the movements and no-motion (control): Cranex 3Dx (CRA), Orthophos SL 3D (ORT), and X1 without (X1wo) and with (X1wi) an automated motion artefact-correction system. For each diagnostic task, 88 examinations were performed. Three observers, blinded to unit and movement, scored image quality: presence of stripe artefacts (present/absent), overall unsharpness (present/absent), and image i...
- 22 March 2018
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 47 (5) , 20180013
Open AccessAn ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability
Objectives:To assess the impact of head motion artefacts and an automated artefact-correction system on CBCT image quality and interpretability for simulated diagnostic tasks.Methods:A partially dentate human skull was mounted on a robot simulating four types of head movement (antero-posterior translation, nodding, lateral rotation, and tremor), at three distances (0.75, 1.5, and 3 mm) based on two movement patterns (skull returning/not returning to the initial position). Two diagnostic tasks were simulated: dental implant planning and detection of a periapical lesion. Three CBCT units were used to examine the skull during the movements and no-motion (control): Cranex 3Dx (CRA), Orthophos SL 3D (ORT), and X1 without (X1wo) and with (X1wi) an automated motion artefact-correction system. For each diagnostic task, 88 examinations were performed. Three observers, blinded to unit and movement, scored image quality: presence of stripe artefacts (present/absent), overall unsharpness (present/absent), and image i...
- 22 March 2016
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (6) , 717-722
Overcoming foetal motion using interactive real‐time magnetic resonance imaging
Summary: Objective: Foetal MRI has become an established image modality in the prenatal diagnosis of CNS anomalies, but image quality can be severely affected by foetal movements. The objective was to overcome these inherent motion problems by applying interactive real‐time MRI and to evaluate the diagnostic usefulness of the applied real‐time MRI sequence in relation to standard protocols.Methods: Ten healthy foetuses (gestation week 21·3 ± 0·5) were scanned using a system, which allowed visual feedback and interactive slice positioning in real time. The data were compared to a control group of 14 healthy foetuses (gestation week 21·0 ± 0·8) who had previously been scanned using standard MRI. Comparisons were carried out by two radiologists with regard to cerebral anthropometric sizes, presence of important brain structures, degree of movement, clinical image value, image quality and ability to obtain correct slice planes.Results: Two out of eight anthropometric sizes were statistically different between the two groups. Representation of cerebral structures was found in 70–100% in the real‐time group. No statistically differences were found in clinical image value and image quality. The mean ability to obtain optimal slice planes was higher in the real‐time group, but it was not significant.Conclusion: Imaging of the foetal brain using the proposed interactive real‐time MRI system is a promising alternative to traditional foetal MRI for anthropometrics or as a supplement for the representation of foetal brain structures in cases in which foetal motion causes challenges in relation to obtaining optimal slice planes using conventional MRI techniques.
- 22 March 2016
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (6) , 717-722
Overcoming foetal motion using interactive real‐time magnetic resonance imaging
Summary: Objective: Foetal MRI has become an established image modality in the prenatal diagnosis of CNS anomalies, but image quality can be severely affected by foetal movements. The objective was to overcome these inherent motion problems by applying interactive real‐time MRI and to evaluate the diagnostic usefulness of the applied real‐time MRI sequence in relation to standard protocols.Methods: Ten healthy foetuses (gestation week 21·3 ± 0·5) were scanned using a system, which allowed visual feedback and interactive slice positioning in real time. The data were compared to a control group of 14 healthy foetuses (gestation week 21·0 ± 0·8) who had previously been scanned using standard MRI. Comparisons were carried out by two radiologists with regard to cerebral anthropometric sizes, presence of important brain structures, degree of movement, clinical image value, image quality and ability to obtain correct slice planes.Results: Two out of eight anthropometric sizes were statistically different between the two groups. Representation of cerebral structures was found in 70–100% in the real‐time group. No statistically differences were found in clinical image value and image quality. The mean ability to obtain optimal slice planes was higher in the real‐time group, but it was not significant.Conclusion: Imaging of the foetal brain using the proposed interactive real‐time MRI system is a promising alternative to traditional foetal MRI for anthropometrics or as a supplement for the representation of foetal brain structures in cases in which foetal motion causes challenges in relation to obtaining optimal slice planes using conventional MRI techniques.
- 29 January 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 411-421
ISMRM Raw data format: A proposed standard for MRI raw datasets
Purpose: This work proposes the ISMRM Raw Data format as a common MR raw data format, which promotes algorithm and data sharing.Methods: A file format consisting of a flexible header and tagged frames of k‐space data was designed. Application Programming Interfaces were implemented in C/C++, MATLAB, and Python. Converters for Bruker, General Electric, Philips, and Siemens proprietary file formats were implemented in C++. Raw data were collected using magnetic resonance imaging scanners from four vendors, converted to ISMRM Raw Data format, and reconstructed using software implemented in three programming languages (C++, MATLAB, Python).Results: Images were obtained by reconstructing the raw data from all vendors. The source code, raw data, and images comprising this work are shared online, serving as an example of an image reconstruction project following a paradigm of reproducible research.Conclusion: The proposed raw data format solves a practical problem for the magnetic resonance imaging community. It may serve as a foundation for reproducible research and collaborations. The ISMRM Raw Data format is a completely open and community‐driven format, and the scientific community is invited (including commercial vendors) to participate either as users or developers. Magn Reson Med 77:411–421, 2017.
- 29 January 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 411-421
ISMRM Raw data format: A proposed standard for MRI raw datasets
Purpose: This work proposes the ISMRM Raw Data format as a common MR raw data format, which promotes algorithm and data sharing.Methods: A file format consisting of a flexible header and tagged frames of k‐space data was designed. Application Programming Interfaces were implemented in C/C++, MATLAB, and Python. Converters for Bruker, General Electric, Philips, and Siemens proprietary file formats were implemented in C++. Raw data were collected using magnetic resonance imaging scanners from four vendors, converted to ISMRM Raw Data format, and reconstructed using software implemented in three programming languages (C++, MATLAB, Python).Results: Images were obtained by reconstructing the raw data from all vendors. The source code, raw data, and images comprising this work are shared online, serving as an example of an image reconstruction project following a paradigm of reproducible research.Conclusion: The proposed raw data format solves a practical problem for the magnetic resonance imaging community. It may serve as a foundation for reproducible research and collaborations. The ISMRM Raw Data format is a completely open and community‐driven format, and the scientific community is invited (including commercial vendors) to participate either as users or developers. Magn Reson Med 77:411–421, 2017.
- 1 November 2015
- Published by Elsevier in Brachytherapy
- Vol. 14 (6) , 953-962
Uncertainties of deformable image registration for dose accumulation of high-dose regions in bladder and rectum in locally advanced cervical cancer
- 1 November 2015
- Published by Elsevier in Brachytherapy
- Vol. 14 (6) , 953-962
Uncertainties of deformable image registration for dose accumulation of high-dose regions in bladder and rectum in locally advanced cervical cancer
- 29 July 2015
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 54 (9) , 1638-1642
A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark
Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Results. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Conclusion. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.
- 29 July 2015
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 54 (9) , 1638-1642
A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark
Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Results. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Conclusion. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.
- 30 November 2014
- Published by Wiley in Medical Physics
- Vol. 41 (11) , 111908
The image quality of ion computed tomography at clinical imaging dose levels
Purpose: Accurately predicting the range of radiotherapy ions in vivo is important for the precise delivery of dose in particle therapy. Range uncertainty is currently the single largest contribution to the dose margins used in planning and leads to a higher dose to normal tissue. The use of ion CT has been proposed as a method to improve the range uncertainty and thereby reduce dose to normal tissue of the patient. A wide variety of ions have been proposed and studied for this purpose, but no studies evaluate the image quality obtained with different ions in a consistent manner. However, imaging doses ion CT is a concern which may limit the obtainable image quality. In addition, the imaging doses reported have not been directly comparable with x‐ray CT doses due to the different biological impacts of ion radiation. The purpose of this work is to develop a robust methodology for comparing the image quality of ion CT with respect to particle therapy, taking into account different reconstruction methods and ion species.Methods: A comparison of different ions and energies was made. Ion CT projections were simulated for five different scenarios: Protons at 230 and 330 MeV, helium ions at 230 MeV/u, and carbon ions at 430 MeV/u. Maps of the water equivalent stopping power were reconstructed using a weighted least squares method. The dose was evaluated via a quality factor weighted CT dose index called the CT dose equivalent index (CTDEI). Spatial resolution was measured by the modulation transfer function. This was done by a noise‐robust fit to the edge spread function. Second, the image quality as a function of the number of scanning angles was evaluated for protons at 230 MeV. In the resolution study, the CTDEI was fixed to 10 mSv, similar to a typical x‐ray CT scan. Finally, scans at a range of CTDEI's were done, to evaluate dose influence on reconstruction error.Results: All ions yielded accurate stopping power estimates, none of which were statistically different from the ground truth image. Resolution (as defined by the modulation transfer function = 10% point) was the best for the helium ions (18.21 line pairs/cm) and worst for the lower energy protons (9.37 line pairs/cm). The weighted quality factor for the different ions ranged from 1.23 for helium to 2.35 for carbon ions. For the angle study, a sharp increase in absolute error was observed below 45 distinct angles, giving the impression of a threshold, rather than smooth, limit to the number of angles.Conclusions: The method presented for comparing various ion CT modalities is feasible for practical use. While all studied ions would improve upon x‐ray CT for particle range estimation, helium appears to give the best results and deserves further study for imaging.
- 30 November 2014
- Published by Wiley in Medical Physics
- Vol. 41 (11) , 111908
The image quality of ion computed tomography at clinical imaging dose levels
Purpose: Accurately predicting the range of radiotherapy ions in vivo is important for the precise delivery of dose in particle therapy. Range uncertainty is currently the single largest contribution to the dose margins used in planning and leads to a higher dose to normal tissue. The use of ion CT has been proposed as a method to improve the range uncertainty and thereby reduce dose to normal tissue of the patient. A wide variety of ions have been proposed and studied for this purpose, but no studies evaluate the image quality obtained with different ions in a consistent manner. However, imaging doses ion CT is a concern which may limit the obtainable image quality. In addition, the imaging doses reported have not been directly comparable with x‐ray CT doses due to the different biological impacts of ion radiation. The purpose of this work is to develop a robust methodology for comparing the image quality of ion CT with respect to particle therapy, taking into account different reconstruction methods and ion species.Methods: A comparison of different ions and energies was made. Ion CT projections were simulated for five different scenarios: Protons at 230 and 330 MeV, helium ions at 230 MeV/u, and carbon ions at 430 MeV/u. Maps of the water equivalent stopping power were reconstructed using a weighted least squares method. The dose was evaluated via a quality factor weighted CT dose index called the CT dose equivalent index (CTDEI). Spatial resolution was measured by the modulation transfer function. This was done by a noise‐robust fit to the edge spread function. Second, the image quality as a function of the number of scanning angles was evaluated for protons at 230 MeV. In the resolution study, the CTDEI was fixed to 10 mSv, similar to a typical x‐ray CT scan. Finally, scans at a range of CTDEI's were done, to evaluate dose influence on reconstruction error.Results: All ions yielded accurate stopping power estimates, none of which were statistically different from the ground truth image. Resolution (as defined by the modulation transfer function = 10% point) was the best for the helium ions (18.21 line pairs/cm) and worst for the lower energy protons (9.37 line pairs/cm). The weighted quality factor for the different ions ranged from 1.23 for helium to 2.35 for carbon ions. For the angle study, a sharp increase in absolute error was observed below 45 distinct angles, giving the impression of a threshold, rather than smooth, limit to the number of angles.Conclusions: The method presented for comparing various ion CT modalities is feasible for practical use. While all studied ions would improve upon x‐ray CT for particle range estimation, helium appears to give the best results and deserves further study for imaging.
- 24 June 2014
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 53 (10) , 1329-1336
Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy
Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p < 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.
- 24 June 2014
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 53 (10) , 1329-1336
Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy
Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p < 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.
- 24 June 2014
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 53 (8) , 1107-1113
Clinical use of iterative 4D-cone beam computed tomography reconstructions to investigate respiratory tumor motion in lung cancer patients
Cone beam computed tomography (CBCT) provides means for respiratory resolved volumetric imaging of the thorax. However, merely sorting the acquired projections into respiratory phases and performing a series of conventional three-dimensional (3D) reconstructions lead to clinically prohibitive reconstruction artifacts. This problem can be mitigated by iterative 4D reconstruction. We present a clinical evaluation of two iterative 4D-CBCT reconstruction algorithms during stereotactic body radiation therapy. Two types of iterative 4D-CBCT reconstructions were performed utilizing: 1) total variation (TV) minimization; and 2) optical flow (OF) based deformable registration between phases. The reconstructions were initially evaluated on a lung phantom with a moveable target insert. Subsequently, 4D-CBCT reconstructions were performed for 19 patients on 2-3 CBCT projection datasets previously acquired for conventional 3D-CBCT reconstruction (∼650 half-fan projections per scan in a full one-minute gantry rotation). The 4D reconstructions were imported into a treatment planning system, where the gross tumor volume (GTV) was delineated and used to extract the tumor motion amplitude. For both phantom and patient scans, the iterative 4D-CBCT reconstructions had sufficient quality for GTV delineation when the breathing period was faster than 3.5 seconds (15 of 19 patients), but not for slower breathing periods (4 patients). The 3D tumor motion amplitude for the patients was significantly lower (p = 10(-6), Wilcoxon signed rank test) in the OF reconstructions (mean 4.0 mm) than in the TV reconstructions (mean 5.3 mm). TV and OF iterative 4D-CBCT reconstruction of the thorax in a lung phantom and for 19 patients was demonstrated from standard CBCT scans and used to estimate the daily lung tumor motion.
- 24 June 2014
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 53 (8) , 1107-1113
Clinical use of iterative 4D-cone beam computed tomography reconstructions to investigate respiratory tumor motion in lung cancer patients
Cone beam computed tomography (CBCT) provides means for respiratory resolved volumetric imaging of the thorax. However, merely sorting the acquired projections into respiratory phases and performing a series of conventional three-dimensional (3D) reconstructions lead to clinically prohibitive reconstruction artifacts. This problem can be mitigated by iterative 4D reconstruction. We present a clinical evaluation of two iterative 4D-CBCT reconstruction algorithms during stereotactic body radiation therapy. Two types of iterative 4D-CBCT reconstructions were performed utilizing: 1) total variation (TV) minimization; and 2) optical flow (OF) based deformable registration between phases. The reconstructions were initially evaluated on a lung phantom with a moveable target insert. Subsequently, 4D-CBCT reconstructions were performed for 19 patients on 2-3 CBCT projection datasets previously acquired for conventional 3D-CBCT reconstruction (∼650 half-fan projections per scan in a full one-minute gantry rotation). The 4D reconstructions were imported into a treatment planning system, where the gross tumor volume (GTV) was delineated and used to extract the tumor motion amplitude. For both phantom and patient scans, the iterative 4D-CBCT reconstructions had sufficient quality for GTV delineation when the breathing period was faster than 3.5 seconds (15 of 19 patients), but not for slower breathing periods (4 patients). The 3D tumor motion amplitude for the patients was significantly lower (p = 10(-6), Wilcoxon signed rank test) in the OF reconstructions (mean 4.0 mm) than in the TV reconstructions (mean 5.3 mm). TV and OF iterative 4D-CBCT reconstruction of the thorax in a lung phantom and for 19 patients was demonstrated from standard CBCT scans and used to estimate the daily lung tumor motion.
- Open Access
- 31 March 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (3) , 1015-1025
Distributed MRI reconstruction using gadgetron-based cloud computing
Purpose To expand the open source Gadgetron reconstruction framework to support distributed computing and to demonstrate that a multinode version of the Gadgetron can be used to provide nonlinear reconstruction with clinically acceptable latency. Methods The Gadgetron framework was extended with new software components that enable an arbitrary number of Gadgetron instances to collaborate on a reconstruction task. This cloud‐enabled version of the Gadgetron was deployed on three different distributed computing platforms ranging from a heterogeneous collection of commodity computers to the commercial Amazon Elastic Compute Cloud. The Gadgetron cloud was used to provide nonlinear, compressed sensing reconstruction on a clinical scanner with low reconstruction latency (eg, cardiac and neuroimaging applications). Results The proposed setup was able to handle acquisition and 11‐SPIRiT reconstruction of nine high temporal resolution real‐time, cardiac short axis cine acquisitions, covering the ventricles for functional evaluation, in under 1 min. A three‐dimensional high‐resolution brain acquisition with 1 mm3 isotropic pixel size was acquired and reconstructed with nonlinear reconstruction in less than 5 min. Conclusion A distributed computing enabled Gadgetron provides a scalable way to improve reconstruction performance using commodity cluster computing. Nonlinear, compressed sensing reconstruction can be deployed clinically with low image reconstruction latency. Magn Reson Med 73:1015–1025, 2015.
- 31 March 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (3) , 1015-1025
Open AccessDistributed MRI reconstruction using gadgetron-based cloud computing
Purpose To expand the open source Gadgetron reconstruction framework to support distributed computing and to demonstrate that a multinode version of the Gadgetron can be used to provide nonlinear reconstruction with clinically acceptable latency. Methods The Gadgetron framework was extended with new software components that enable an arbitrary number of Gadgetron instances to collaborate on a reconstruction task. This cloud‐enabled version of the Gadgetron was deployed on three different distributed computing platforms ranging from a heterogeneous collection of commodity computers to the commercial Amazon Elastic Compute Cloud. The Gadgetron cloud was used to provide nonlinear, compressed sensing reconstruction on a clinical scanner with low reconstruction latency (eg, cardiac and neuroimaging applications). Results The proposed setup was able to handle acquisition and 11‐SPIRiT reconstruction of nine high temporal resolution real‐time, cardiac short axis cine acquisitions, covering the ventricles for functional evaluation, in under 1 min. A three‐dimensional high‐resolution brain acquisition with 1 mm3 isotropic pixel size was acquired and reconstructed with nonlinear reconstruction in less than 5 min. Conclusion A distributed computing enabled Gadgetron provides a scalable way to improve reconstruction performance using commodity cluster computing. Nonlinear, compressed sensing reconstruction can be deployed clinically with low image reconstruction latency. Magn Reson Med 73:1015–1025, 2015.
- 14 March 2014
- Published by Wiley in Medical Physics
- Vol. 41 (4) , 042302
Three‐dimensional liver motion tracking using real‐time two‐dimensional MRI
Purpose:: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR‐Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real‐time spatial target localization. This study develops and evaluates a method for tracking three‐dimensional (3D) respiratory liver motion in two‐dimensional (2D) real‐time MRI image series with high temporal and spatial resolution.Methods:: The proposed method for 3D tracking in 2D real‐time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real‐time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through‐plane and in‐plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real‐time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions.Results:: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in‐plane motion or estimated indirectly as through‐plane motion. The mean peak‐to‐peak breathing amplitude was 1.6 mm (left‐right), 11.0 mm (craniocaudal), and 2.5 mm (anterior‐posterior). The position of the watermelon structure was estimated in 2D MRI images with a root‐mean‐square error of 0.52 mm (in‐plane) and 0.87 mm (through‐plane).Conclusions:: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real‐time 3D localization with integrated MR‐Linac systems.
- 14 March 2014
- Published by Wiley in Medical Physics
- Vol. 41 (4) , 042302
Three‐dimensional liver motion tracking using real‐time two‐dimensional MRI
Purpose:: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR‐Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real‐time spatial target localization. This study develops and evaluates a method for tracking three‐dimensional (3D) respiratory liver motion in two‐dimensional (2D) real‐time MRI image series with high temporal and spatial resolution.Methods:: The proposed method for 3D tracking in 2D real‐time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real‐time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through‐plane and in‐plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real‐time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions.Results:: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in‐plane motion or estimated indirectly as through‐plane motion. The mean peak‐to‐peak breathing amplitude was 1.6 mm (left‐right), 11.0 mm (craniocaudal), and 2.5 mm (anterior‐posterior). The position of the watermelon structure was estimated in 2D MRI images with a root‐mean‐square error of 0.52 mm (in‐plane) and 0.87 mm (through‐plane).Conclusions:: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real‐time 3D localization with integrated MR‐Linac systems.