Jie Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jie Li has a total of 306 co-authors. Here are the top co-authors by number of shared publications:
C. K. Ong
Center for Superconducting and Magnetic Materials and Department of Physics, National University of Singapore, Singapore 119260
10 shared publicationsQ. Huang
Department of Physics, National University of Singapore, Singapore 119 260 SG
10 shared publicationsD.N. Zheng
9 shared publicationsD. N. Zheng
Beijing National Laboratory for Condensed Matter Physics & Institute of Physics, Chinese Academy of Sciences 3 , Beijing 100190, China
8 shared publications- Song-Lin Li
School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
8 shared publications - Dong-Ning Zheng
Chinese Academy of Sciences
7 shared publications
Latest Publications
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (7) , 1-6
International Round-Robin Test of Critical Current of Superconducting Cable Sample
Ten institutes from six countries participated in an international round-robin test to evaluate the critical current of a superconducting power cable made of Bi-2223 tapes. The cable design featured a two-layer inner core conductor and a single-layer outer shield conductor. The shield layer measured approximately 40 mm in diameter, and the cable length was 2.0 m. To eliminate the influence of resistive voltage drops from current transfer, voltage taps for measurement were positioned at a sufficient distance from the current terminals. The critical current was determined using the resistive method with the electric field criterion of 1.0 ${\rm{\mu V}}/\text{cm}$ . In addition, the $n$ -value, an optional parameter reflecting the current–voltage ( $I$ – $V$ ) characteristics, was extracted from the $I$ – $V$ curve within an electric field range of 0.1–1.0 ${\rm{\mu V}}/\text{cm}$ . A detailed uncertainty analysis was conducted for both the critical current and the $n$ -value. Finally, this article discusses the potential for standardization of the employed resistive measurement method.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (7) , 1-6
International Round-Robin Test of Critical Current of Superconducting Cable Sample
Ten institutes from six countries participated in an international round-robin test to evaluate the critical current of a superconducting power cable made of Bi-2223 tapes. The cable design featured a two-layer inner core conductor and a single-layer outer shield conductor. The shield layer measured approximately 40 mm in diameter, and the cable length was 2.0 m. To eliminate the influence of resistive voltage drops from current transfer, voltage taps for measurement were positioned at a sufficient distance from the current terminals. The critical current was determined using the resistive method with the electric field criterion of 1.0 ${\rm{\mu V}}/\text{cm}$ . In addition, the $n$ -value, an optional parameter reflecting the current–voltage ( $I$ – $V$ ) characteristics, was extracted from the $I$ – $V$ curve within an electric field range of 0.1–1.0 ${\rm{\mu V}}/\text{cm}$ . A detailed uncertainty analysis was conducted for both the critical current and the $n$ -value. Finally, this article discusses the potential for standardization of the employed resistive measurement method.
- Open Access
- 4 April 2022
- Published by Elsevier in Superconductivity
- Vol. 1, 100004
China’s participation in the international RRT for Ic measurement of superconducting cables organized by IEC/TC90
- 4 April 2022
- Published by Elsevier in Superconductivity
- Vol. 1, 100004
Open AccessChina’s participation in the international RRT for Ic measurement of superconducting cables organized by IEC/TC90
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (8) , 2523-2529
Encapsulated Microbubble Fiber-Tip Fabry-Perot Cavity With Tunable Bandwidth for Sensitive Acoustic Detection
A photothermally generated microbubble on a single-mode fiber tip with tunable frequency bandwidth was demonstrated for sensitive detection of acoustic waves. The microbubble with spherical gas-water interface formed a flexible Fabry-Pérot cavity at the fiber tip and detected the acoustic waves by interferometric readout of the bubble deformation. To work in different liquids besides water, the sensor was encapsulated into a water-filled tube and the effects of the encapsulation process on the optical and acoustic characteristics of the sensor were investigated. A 40 μm-diameter microbubble based sensor exhibited a noise-equivalent pressure level of ∼1.0 mPa/Hz 1/2 at the frequency of ∼100 kHz. The bubble diameter was photothermally changed from 20 μm to 60 μm, which enabled online tuning of the sensor resonant frequency from 100 kHz to 300 kHz. This tunable feature is attractive to applications that requires the detection of acoustic waves covering different frequency bands. The encapsulated microbubble sensor with advantages of high sensitivity, tunable bandwidth and low-cost would be interesting for applications in biomedical and industrial areas involving various liquid environments.
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (8) , 2523-2529
Encapsulated Microbubble Fiber-Tip Fabry-Perot Cavity With Tunable Bandwidth for Sensitive Acoustic Detection
A photothermally generated microbubble on a single-mode fiber tip with tunable frequency bandwidth was demonstrated for sensitive detection of acoustic waves. The microbubble with spherical gas-water interface formed a flexible Fabry-Pérot cavity at the fiber tip and detected the acoustic waves by interferometric readout of the bubble deformation. To work in different liquids besides water, the sensor was encapsulated into a water-filled tube and the effects of the encapsulation process on the optical and acoustic characteristics of the sensor were investigated. A 40 μm-diameter microbubble based sensor exhibited a noise-equivalent pressure level of ∼1.0 mPa/Hz 1/2 at the frequency of ∼100 kHz. The bubble diameter was photothermally changed from 20 μm to 60 μm, which enabled online tuning of the sensor resonant frequency from 100 kHz to 300 kHz. This tunable feature is attractive to applications that requires the detection of acoustic waves covering different frequency bands. The encapsulated microbubble sensor with advantages of high sensitivity, tunable bandwidth and low-cost would be interesting for applications in biomedical and industrial areas involving various liquid environments.
- Open Access
- 17 June 2021
- Published by Springer Nature in Advances in Aerodynamics
- Vol. 3 (1) , 1-12
High frequency AC electric glow discharge visualization technology and application in big diameter hypersonic low-density wind tunnel
In order to visualize the rarefied flow field in a Φ1m hypersonic low-density wind tunnel, an electric glow discharge technique based on high frequency excited power has been developed. Firstly, finite element simulation analysis has been carried out, and it is concluded that the breakdown voltage can be reduced by using high frequency power supply; then an electric glow discharge apparatus has been fabricated, and the discharge images were compared with simulations; besides, a clear flow field around HB-1 standard model has been observed using this technology; finally, the influence of glow discharge on the flow field, as well as the differences between direct current and high frequency electric glow discharges is discussed at the end of this paper.
- 17 June 2021
- Published by Springer Nature in Advances in Aerodynamics
- Vol. 3 (1) , 1-12
Open AccessHigh frequency AC electric glow discharge visualization technology and application in big diameter hypersonic low-density wind tunnel
In order to visualize the rarefied flow field in a Φ1m hypersonic low-density wind tunnel, an electric glow discharge technique based on high frequency excited power has been developed. Firstly, finite element simulation analysis has been carried out, and it is concluded that the breakdown voltage can be reduced by using high frequency power supply; then an electric glow discharge apparatus has been fabricated, and the discharge images were compared with simulations; besides, a clear flow field around HB-1 standard model has been observed using this technology; finally, the influence of glow discharge on the flow field, as well as the differences between direct current and high frequency electric glow discharges is discussed at the end of this paper.
- 12 May 2021
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Physica, Mechanica & Astronomica
- Vol. 51 (6) , 067514
Zero-field cooling exchange bias induced by spin metastable state in MnNiGa system
- 12 May 2021
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Physica, Mechanica & Astronomica
- Vol. 51 (6) , 067514
Zero-field cooling exchange bias induced by spin metastable state in MnNiGa system
- 22 January 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (2) , 025505
Research on corona discharge suppression of high-voltage direct-current transmission lines based on dielectric-film-covered conductor
Corona discharge suppression for high-voltage direct-current (HVDC) transmission lines at line terminals such as converter stations is a subject that requires attention. In this paper, a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup. Compared with the bare conductor, the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device. The influences of film thickness and film material on the corona discharge suppression effect are investigated. The charge accumulation and dissipation characteristics of different film materials are also studied. The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge. The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength, and its ion current density is at the nA m−2 level. The corona threshold voltage can be promoted by increasing the film thickness, but the ability to inhibit corona discharge becomes weak. The larger the surface electric field strength, the more charge accumulated, but the faster the charge dissipation rate. Compared with polyvinyl chloride film, cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate, which can better restrain the corona discharge of HVDC transmission lines.
- 22 January 2021
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 23 (2) , 025505
Research on corona discharge suppression of high-voltage direct-current transmission lines based on dielectric-film-covered conductor
Corona discharge suppression for high-voltage direct-current (HVDC) transmission lines at line terminals such as converter stations is a subject that requires attention. In this paper, a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup. Compared with the bare conductor, the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device. The influences of film thickness and film material on the corona discharge suppression effect are investigated. The charge accumulation and dissipation characteristics of different film materials are also studied. The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge. The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength, and its ion current density is at the nA m−2 level. The corona threshold voltage can be promoted by increasing the film thickness, but the ability to inhibit corona discharge becomes weak. The larger the surface electric field strength, the more charge accumulated, but the faster the charge dissipation rate. Compared with polyvinyl chloride film, cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate, which can better restrain the corona discharge of HVDC transmission lines.
- 24 April 2019
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 61 (6) , 064002
Study of electromagnetic mode contributing inward particle pinch in the scrape-off layer during H-mode discharge
With the application of a four-tip Langmuir probe, the anomalous transport contributed by the turbulence and its impact on particle decay length in the scrape-off layer (SOL) has been studied on HL-2A tokamak. A high-frequency electromagnetic mode (HFM, 100 kHz < f HFM < 400 kHz) is reported, which can both be observed in the pedestal region and the SOL during the type-III ELMy H-mode discharge. In SOL, the HFM propagates in the electron diamagnetic direction in both the laboratory frame (22 km s −1 ) and plasma frame (24 km s −1 ) with m ≃ 28, n ∼ 8 and k θ ρ i ∼ 0.04. Direct measurement shows that the HFM can drive inward particle flux, which can be explained by the electron diamagnetic rotation of the HFM. The time evolutions of particle flux driven by the low frequency turbulence (LFT, ‘blobby’ structures) and the HFM as well as the typical decay length of divertor particle flux suggest that the decay length in SOL can both be modified by the outward particle transport of the ‘blobby’ structures (Γ r ,LFT , r ,HFM ). The decay length of the particle flux is mostly suppressed when a significant inward flux by the HFM bursts under the condition of a low-level outward flux by ‘blobby’ events, suggesting the important role of anomalous transport on the decay length in the SOL.
- 24 April 2019
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 61 (6) , 064002
Study of electromagnetic mode contributing inward particle pinch in the scrape-off layer during H-mode discharge
With the application of a four-tip Langmuir probe, the anomalous transport contributed by the turbulence and its impact on particle decay length in the scrape-off layer (SOL) has been studied on HL-2A tokamak. A high-frequency electromagnetic mode (HFM, 100 kHz < f HFM < 400 kHz) is reported, which can both be observed in the pedestal region and the SOL during the type-III ELMy H-mode discharge. In SOL, the HFM propagates in the electron diamagnetic direction in both the laboratory frame (22 km s −1 ) and plasma frame (24 km s −1 ) with m ≃ 28, n ∼ 8 and k θ ρ i ∼ 0.04. Direct measurement shows that the HFM can drive inward particle flux, which can be explained by the electron diamagnetic rotation of the HFM. The time evolutions of particle flux driven by the low frequency turbulence (LFT, ‘blobby’ structures) and the HFM as well as the typical decay length of divertor particle flux suggest that the decay length in SOL can both be modified by the outward particle transport of the ‘blobby’ structures (Γ r ,LFT , r ,HFM ). The decay length of the particle flux is mostly suppressed when a significant inward flux by the HFM bursts under the condition of a low-level outward flux by ‘blobby’ events, suggesting the important role of anomalous transport on the decay length in the SOL.
- 20 November 2013
- Published by Springer Nature in Science China Physics, Mechanics & Astronomy
- Vol. 56 (12) , 2312-2326
Growth and in situ high-pressure reflection high energy electron diffraction monitoring of oxide thin films
- 20 November 2013
- Published by Springer Nature in Science China Physics, Mechanics & Astronomy
- Vol. 56 (12) , 2312-2326
Growth and in situ high-pressure reflection high energy electron diffraction monitoring of oxide thin films
- 1 September 2013
- Published by IOP Publishing in Chinese Physics B
- Vol. 22 (9) , 090312
Spectroscopy and coherent manipulation of single and coupled flux qubits
Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time TRabi = 78 ns and energy relaxation time T1 = 315 ns. We found that the value of TRabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.
- 1 September 2013
- Published by IOP Publishing in Chinese Physics B
- Vol. 22 (9) , 090312
Spectroscopy and coherent manipulation of single and coupled flux qubits
Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time TRabi = 78 ns and energy relaxation time T1 = 315 ns. We found that the value of TRabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.
- 1 August 2013
- Published by IOP Publishing in Chinese Physics B
- Vol. 22 (8) , 087503
Field-induced insulator—metal—insulator transitions in low-energy H+2ion-irradiated epitaxial La2/3Ca1/3MnO3thin films
- 1 August 2013
- Published by IOP Publishing in Chinese Physics B
- Vol. 22 (8) , 087503
Field-induced insulator—metal—insulator transitions in low-energy H+2ion-irradiated epitaxial La2/3Ca1/3MnO3thin films