MCMichele Carrabba

Michele Carrabba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michele Carrabba has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Thickness of Opaque Porcelain and Alloy Color on the Final Color of Porcelain-Fused-to-Metal Restorations

    by Alessandro Vichi, Gabriele Corciolani, Michele Carrabba, Alvaro Munoz, Chris Louca

    Despite the advent of metal-free solutions, porcelain-fused-to-metal restorations (PFM) are still widely used. Particularly for the latest ceramic systems, scarce information is present in the scientific literature about the ideal opaque layer thickness and the alloy color impact to achieve the desired final color of PFM restorations. This study aimed to evaluate the influence of opaque thickness variation layered on different metal alloys on the final color of PFM restorations. Opaque porcelain of one metal–ceramic system (VITA VM13) was layered in four different thicknesses (0.10 mm, 0.15 mm, 0.20 mm, and 0.25 mm) on three differently colored dental alloys: a gold–platinum alloy (yellowish), a gold–palladium alloy (light grayish), and a nickel–chromium alloy (dark grayish). The veneering porcelain layered over the opaque was kept constant (Base Dentine 0.45 mm, Transpa Dentine 0.50 mm, and Enamel 0.20 mm). Sixty specimens were fabricated, five samples for each combination of alloy/opaque thickness. The color difference (ΔE) between specimen and reference was measured using a clinical spectrophotometer. The two-way ANOVA revealed that the thickness of both the opaque (p < 0.001) and the metal alloy (p < 0.001) significantly influenced the ΔE values. Gray-colored alloys covered by a 0.10 mm thick opaque layer enabled the closest color match, whereas this occurred for yellow-color alloys covered by a 0.15 mm thick opaque layer. In contrast, the samples covered by a 0.25 mm thick opaque layer obtained the worst ΔE.


  • Open Access

    Comparison between Hydrofluoric Acid and Single-Component Primer as Conditioners on Resin Cement Adhesion to Lithium Silicate and Lithium Disilicate Glass Ceramics

    by Alessandro Vichi, Riccardo Fabian Fonzar, Michele Carrabba, Chris Louca, Nicola Scotti, Claudia Mazzitelli, Lorenzo Breschi, Cecilia Goracci

    This study aimed at evaluating the effects of different surface conditionings on the microshear bond strength (µSBS) of a self-adhesive resin cement to VITA Suprinity (ZLS) and IPS e.max CAD (LD). Three surface conditioning protocols were performed on ZLS and LD before luting with a self-adhesive resin cement (RelyX Unicem 2, RXU): hydrofluoric acid (HF), HF + silane (HF + S), or Monobond Etch & Prime (EP). In each group, 15 cylindrical buildups of RXU were prepared on five milled bars and submitted to a µSBS test. Data were statistically analyzed with two-way ANOVA and Tukey’s post hoc test (p < 0.05). Failure modes were recorded and classified as adhesive, mixed, cohesive in resin, or ceramic, and statistically analyzed with Fisher’s exact test (p = 0.05). One additional bar per group was used for the morphological characterization of the conditioned surface by means of SEM. The material per se did not significantly influence adhesion (p = 0.744). Conditioning protocol was a significant factor: EP yielded significantly higher μSBS than HF (p = 0.005), while no significant differences emerged between EP and HF + S (p = 0.107), or HF + S and HF (p = 0.387). The material-conditioning protocol interaction was not statistically significant (p = 0.109). Significant intergroup differences were found in distribution of failure modes: mixed failures were predominant in the ZLS/EP group, while the other groups showed a prevalence of adhesive failures. The self-etching primer showed promising results in terms of immediate bond strength of a self-adhesive resin cement to lithium-silica-based glass ceramics, suggesting its alternative use to hydrofluoric acid and silane conditioning protocols.


  • Cement opacity and color as influencing factors on the final shade of metal‐free ceramic restorations

    by Michele Carrabba, Alessandro Vichi, Gianluca Tozzi, Chris Louca, Marco Ferrari

    Objective: To investigate the influence of opacity and color of luting cements on the final shade of metal‐free restorations.Materials and Methods: Five resin cement colors in combination with four different thicknesses of CAD/CAM ceramic materials were tested, and a composite substrate was used as dentin color reference (n = 3). Specimen color was measured with a spectrophotometer equipped with an integrating sphere before and after cementation (CIELAB). Cement and ceramic color and opacity (TP) were assessed by measuring the tested ceramic thickness as a 1‐mm thick disk for each of the cement shades. The differences in color were evaluated (ΔE00). Data were statistically analyzed by a Two‐Way ANOVA followed by the Tukey Test for post‐hoc comparison (P < .05) and multiple comparison Pearson's test (P < .05); the acceptability and perceptibility threshold were evaluated.Results: Statistically significant influence was found for factors ceramic thickness and cement shade (P < .001). Perceptible and unacceptable color changes were induced on the final restoration by resin cements (ranging from ΔE00 = 0.69 ± 0.54 to ΔE00 = 5.53 ± 0.46), the correlation between factors became strong (r2 > 0.6) in case of mismatch between color and translucency of cement and ceramic. Only the clear shade in combination with the thickest ceramic, resulted in an imperceptible color change (ΔE00 = 0.69 ± 0.54).Conclusions: The final shade of ceramic restorations can be influenced by resin cements; the magnitude of influence is related to the cement optical properties.Clinical Significance: In order to influence the final shade of a ceramic restoration, a cement more opaque than the restorative material should be used. Conversely, in the case of a fitting shade of the restoration, a cement more translucent than the restoration should be used to avoid undesired changes.


  • Influência da Cor do Pilar e da Espessura da Mucosa Sobre a Cor do Tecido Mole

    by Marco Ferrari, Michele Carrabba, Alessandro Vichi, Cecilia Goracci, Maria Crysanti Cagidiaco

  • Post-Retained Single Crowns versus Fixed Dental Prostheses: A 7-Year Prospective Clinical Study

    by M. Ferrari, R. Sorrentino, J. Juloski, S. Grandini, M. Carrabba, N. Discepoli, E. Ferrari Cagidiaco

    Biomechanical integrity of endodontically treated teeth (ETT) is often compromised. Degree of hard tissue loss and type of final prosthetic restoration should be carefully considered when making a treatment plan. The objective of this prospective clinical trial was to assess the influence of the type of prosthetic restoration as well as the degree of hard tissue loss on 7-y clinical performance of ETT restored with fiber posts. Two groups ( n = 60) were defined depending on the type of prosthetic restoration needed: 1) single unit porcelain-fused-to-metal (PFM) crowns (SCs) and 2) 3- to 4-unit PFM fixed dental prostheses (FDPs), with 1 healthy and 1 endodontically treated and fiber post-restored abutment. Within each group, samples were divided into 2 subgroups ( n = 30) according to the amount of residual coronal tissues after abutment buildup and final preparation: A) >50% of coronal residual structure or B) equal to or <50% of coronal residual structure. The clinical outcome was assessed based on clinical and intraoral radiographic examinations at the recalls after 6, 12, 24, 36, 48, and 84 mo. Data were analyzed by Kaplan-Meier log-rank test and Cox regression analysis ( P < 0.05). The overall 7-y survival rate of ETT restored with fiber post and either SCs or FDPs was 69.2%. The highest 84-mo survival rate was recorded in group 1A (90%), whereas teeth in group 2B exhibited the lowest performance (56.7% survival rate). The log-rank test detected statistically significant differences in survival rates among the groups ( P = 0.048). Cox regression analysis revealed that the amount of residual coronal structure ( P = 0.041; hazard ratio [HR], 2.026; 95% confidence interval [CI] for HR, 1.031–3.982) and the interaction between the type of prosthetic restoration and the amount of residual coronal structure ( P = 0.024; HR, 1.372; 95% CI for HR, 1.042–1.806) were statistically significant factors for survival ( ClinicalTrials.gov NCT01532947).


  • Open Access

    Translucent zirconia in the ceramic scenario for monolithic restorations: A flexural strength and translucency comparison test

    by Michele Carrabba, Andrew J. Keeling, Aziz Aziz, Alessandro Vichi, Riccardo Fabian Fonzar, David Wood, Marco Ferrari


  • Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color

    by Marco Ferrari, Michele Carrabba, Alessandro Vichi, Cecilia Goracci, Maria Cagidiaco

    Marco Ferrari, MD, DMD, PhD/Michele Carrabba, DDS, PhD/Alessandro Vichi, DDS, MS, PhD/Cecilia Goracci, DDS, MS, PhD/Maria Crysanti Cagidiaco, MD, DMD, PhD: Purpose: Zirconia (ZrO2) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium?s gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO2 and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. Materials and Methods: Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (> 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO2. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l?Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. Results: Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO2 group. All the patients with thin soft tissues reported color changes that exceeded the critical threshold. Conclusion: The different abutment materials showed comparable results in terms of influence on soft tissue color. Regarding peri-implant soft tissue thickness, the influence of the tested abutments on soft tissue color became clinically relevant for values ≤ 2 mm.


  • Effect of Finishing and Polishing on the Surface Roughness and Gloss of Feldspathic Ceramic for Chairside CAD/CAM Systems

    by M Carrabba, A Vichi, G Vultaggio, S Pallari, R Paravina, M Ferrari

    SUMMARY: Objectives: To evaluate surface roughness and gloss of feldspathic ceramic blocks for chairside CAD/CAM systems before and after finishing and polishing.Methods: VITA Mark II ceramic blocks for the CEREC CAD/CAM system were cut perpendicularly in order to obtain a total of 70 specimens (14 × 18 × 3 mm). The flat surface was roughened using a grinder/polisher with dry 120-grit silicone-carbide paper. Surface roughness and gloss were measured using a digital profilometer (Ra) and a glossmeter (GU), respectively. Specimens were randomly divided into seven groups (n=10) based on the finishing/polishing system as follows: 1) Identoflex NGPorcelain Polisher (INP), 2) Identoflex Diamond Ceramic Polisher (IDP), 3) Hiluster Polishing System (HPS), 4) OptraFine (OF), 5) Identoflex Lucent (IL), 6) VITA Akzent Glaze Spray (AGS), and 7) VITA Shading Paste and Liquid (SPL). Surface analysis was repeated after the finishing/polishing treatment, and the obtained data were compared to the baseline in order to evaluate the ΔRa and ΔGU. Results were statistically analyzed. The surface morphology was observed by scanning electron microscopy.Results: The mean surface roughness of polished systems increased in the order (statistical groups designated) SPLa < ILa < OFab < IDPbc < AGSbc < INPbc < HPSc and mean gloss decreased in the order AGSa > SPLa > OFab > ILabc > HPSbcd > INPcd > IDPd.Conclusions: The smoothest surface of CAD/CAM feldspathic ceramic blocks was achieved using the furnace-based glaze systems VITA Akzent Glaze Spray and VITA Shading Paste and Liquid and manual systems Identoflex Lucent and OptraFine.


  • Open Access

    Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics

    by Michele Carrabba, Alessandro Vichi, Chris Louca, Marco Ferrari

    Carrabba M, et al. J Adv Prosthodont. 2017 Aug;9(4):257-264. https://doi.org/10.4047/jap.2017.9.4.257


  • Flexural resistance of heat-pressed and CAD-CAM lithium disilicate with different translucencies

    by Riccardo Fabian Fonzar, Michele Carrabba, Maurizio Sedda, Marco Ferrari, Cecilia Goracci, Alessandro Vichi