Ceren Kaçar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ceren Kaçar has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Berna Dalkiran
Ankara University, Faculty of Science, Department of Chemistry, Ankara, Turkey
5 shared publications - Esma Kılıç
Department of Chemistry, Faculty of Science, Ankara University, Ankara, Turkey
5 shared publications - Pınar Esra Erden
Ankara University
5 shared publications - Dilek Söğüt Özdemir
Selcuk University
1 shared publication E. Kiliç
1 shared publication- Emine Kubra İnAl
Ankara University
1 shared publication
Latest Publications
- 11 May 2024
- Published by Springer Nature in Ionics
- Vol. 30 (7) , 4215-4226
Electrochemical xanthine biosensor based on carbon nanofiber and ferrocene carboxylic acid for the assessment of fish freshness
- 11 May 2024
- Published by Springer Nature in Ionics
- Vol. 30 (7) , 4215-4226
Electrochemical xanthine biosensor based on carbon nanofiber and ferrocene carboxylic acid for the assessment of fish freshness
- 14 July 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (10) , 2118-2127
Disposable Bienzymatic Choline Biosensor Based on MnO2 Nanoparticles Decorated Carbon Nanofibers and Poly(methylene green) Modified Screen Printed Carbon Electrode
In this study, utilization of MnO2 nanoparticles decorated carbon nanofibers (CNF‐MnO2) and poly(methylene green) (PMG) to create a bienzymatic biosensor for choline determination is described. Choline oxidase (ChOx) and horseradish peroxidase (HRP) were co‐immobilized onto the CNF‐MnO2/PMG/SPCE by glutaraldehyde crosslinking. Scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed to investigate the morphology and electrochemical behavior of the modified electrodes. Upon optimized conditions, ChOx‐HRP/CNF‐MnO2/PMG/SPCE had a wide working range of 4.0×10−6–9.0×10−3 M with a sensitivity of 2.44 μA mM−1 and detection limit of 8.1×10−7 M. The proposed biosensor exhibits high repeatability (RSD 2.7 %) and retained 97 % of its initial activity after stored 15 days at +4 °C. The applicability of the biosensor in infant formula was demonstrated.
- 14 July 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (10) , 2118-2127
Disposable Bienzymatic Choline Biosensor Based on MnO2 Nanoparticles Decorated Carbon Nanofibers and Poly(methylene green) Modified Screen Printed Carbon Electrode
In this study, utilization of MnO2 nanoparticles decorated carbon nanofibers (CNF‐MnO2) and poly(methylene green) (PMG) to create a bienzymatic biosensor for choline determination is described. Choline oxidase (ChOx) and horseradish peroxidase (HRP) were co‐immobilized onto the CNF‐MnO2/PMG/SPCE by glutaraldehyde crosslinking. Scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed to investigate the morphology and electrochemical behavior of the modified electrodes. Upon optimized conditions, ChOx‐HRP/CNF‐MnO2/PMG/SPCE had a wide working range of 4.0×10−6–9.0×10−3 M with a sensitivity of 2.44 μA mM−1 and detection limit of 8.1×10−7 M. The proposed biosensor exhibits high repeatability (RSD 2.7 %) and retained 97 % of its initial activity after stored 15 days at +4 °C. The applicability of the biosensor in infant formula was demonstrated.
- 19 February 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (8) , 1933-1946
Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase– or monoamine oxidase–modified electrodes
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 × 10−6–6.9 × 10−4 M with a sensitivity of 1.84 μA mM−1. On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
- 19 February 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (8) , 1933-1946
Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase– or monoamine oxidase–modified electrodes
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 × 10−6–6.9 × 10−4 M with a sensitivity of 1.84 μA mM−1. On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
- Open Access
- 31 January 2020
- Published by Duzce Universitesi Bilim ve Teknoloji Dergisi in Düzce Üniversitesi Bilim ve Teknoloji Dergisi
- Vol. 8 (1) , 631-641
Tryptamine Biosensor Based on Amino-Functionalized Multiwalled Carbon Nanotubes, Tin Oxide Nanoparticles and Diamine Oxidase
Tr en Bu çalışmada amino fonksiyonlu çok duvarlı karbon nanotüp (NH2 - MWCNT) ve kalay oksit nanopartikül (SnO2) ile modifiye edilmiş perde baskılı karbon elektrotlara (SPCE) dayanan amperometrik triptamin biyosensörü geliştirildi. Diamin oksidaz (DAO) enzimi NH2 - MWCNT-SnO2/SPCE yüzeyine N-etil-N′-(3-dimetilaminopropil) karbodiimit (EDC) ve N-hidroksi süksinimit (NHS) kullanılarak kovalent bağlama yöntemi ile immobilize edildi. Hazırlanan elektrot yüzeyi, enzimlerin yüzeyden uzaklaşmasını engellemek ve girişim etkilerini azaltmak amacıyla son olarak Nafyon ile kaplandı. Biyosensörün yüzey morfolojisi, elektrokimyasal özellikleri ve analitik performansı taramalı elektron mikroskobu (SEM), dönüşümlü voltammetri (CV), elektrokimyasal empedans spektroskopi (EIS) ve kronoamperometri yöntemleri kullanılarak incelendi. Geliştirilen biyosensör ile triptamin için elde edilen doğrusal çalışma aralığı, gözlenebilme sınırı ve duyarlık sırası ile 2,0×10-6 ‒ 2,5×10-3 M, 6,0×10-7 M ve 6,52 µA mM-1 olarak bulundu. Hazırlanan biyosensörün tekrar kullanılabilirlik ve tekrar üretilebilirliğinin oldukça iyi olduğu belirlendi. In this study, amperometric tryptamine biosensor based on amino functionalized multiwalled carbon nanotubes (NH2 - MWCNT) and tin oxide nanoparticles (SnO2) modified screen-printed carbon electrode (SPCE) was developed. Diamine oxidase (DAO) enzyme was covalently immobilized onto NH2 - MWCNT-SnO2/SPCE surface via (1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide) (EDC) ve N-hydroxysuccinimide (NHS) chemistry. The resulting electrode surface was finally covered with Nafion in order to prevent enzyme leakage from the surface and minimize the effect of interferences. The surface morphology, electrochemical bahaviour and analytical performance of the biosensor was investigated by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry methods. Linear working range, limit of detection and sensitivity of the developed biosensor was found to be 2.0×10-6 ‒ 2.5×10-3 M, 6.0×10-7 M ve 6.52 µA mM-1, respectively. Biosensor also showed high repeatability and reproducibility.
- 31 January 2020
- Published by Duzce Universitesi Bilim ve Teknoloji Dergisi in Düzce Üniversitesi Bilim ve Teknoloji Dergisi
- Vol. 8 (1) , 631-641
Open AccessTryptamine Biosensor Based on Amino-Functionalized Multiwalled Carbon Nanotubes, Tin Oxide Nanoparticles and Diamine Oxidase
Tr en Bu çalışmada amino fonksiyonlu çok duvarlı karbon nanotüp (NH2 - MWCNT) ve kalay oksit nanopartikül (SnO2) ile modifiye edilmiş perde baskılı karbon elektrotlara (SPCE) dayanan amperometrik triptamin biyosensörü geliştirildi. Diamin oksidaz (DAO) enzimi NH2 - MWCNT-SnO2/SPCE yüzeyine N-etil-N′-(3-dimetilaminopropil) karbodiimit (EDC) ve N-hidroksi süksinimit (NHS) kullanılarak kovalent bağlama yöntemi ile immobilize edildi. Hazırlanan elektrot yüzeyi, enzimlerin yüzeyden uzaklaşmasını engellemek ve girişim etkilerini azaltmak amacıyla son olarak Nafyon ile kaplandı. Biyosensörün yüzey morfolojisi, elektrokimyasal özellikleri ve analitik performansı taramalı elektron mikroskobu (SEM), dönüşümlü voltammetri (CV), elektrokimyasal empedans spektroskopi (EIS) ve kronoamperometri yöntemleri kullanılarak incelendi. Geliştirilen biyosensör ile triptamin için elde edilen doğrusal çalışma aralığı, gözlenebilme sınırı ve duyarlık sırası ile 2,0×10-6 ‒ 2,5×10-3 M, 6,0×10-7 M ve 6,52 µA mM-1 olarak bulundu. Hazırlanan biyosensörün tekrar kullanılabilirlik ve tekrar üretilebilirliğinin oldukça iyi olduğu belirlendi. In this study, amperometric tryptamine biosensor based on amino functionalized multiwalled carbon nanotubes (NH2 - MWCNT) and tin oxide nanoparticles (SnO2) modified screen-printed carbon electrode (SPCE) was developed. Diamine oxidase (DAO) enzyme was covalently immobilized onto NH2 - MWCNT-SnO2/SPCE surface via (1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide) (EDC) ve N-hydroxysuccinimide (NHS) chemistry. The resulting electrode surface was finally covered with Nafion in order to prevent enzyme leakage from the surface and minimize the effect of interferences. The surface morphology, electrochemical bahaviour and analytical performance of the biosensor was investigated by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry methods. Linear working range, limit of detection and sensitivity of the developed biosensor was found to be 2.0×10-6 ‒ 2.5×10-3 M, 6.0×10-7 M ve 6.52 µA mM-1, respectively. Biosensor also showed high repeatability and reproducibility.
- 19 December 2018
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (7) , 5381-5398
Effect of hexaammineruthenium chloride and/or horseradish peroxidase on the performance of hydrogen peroxide (bio)sensors: a comparative study
- 19 December 2018
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (7) , 5381-5398
Effect of hexaammineruthenium chloride and/or horseradish peroxidase on the performance of hydrogen peroxide (bio)sensors: a comparative study
- 19 January 2018
- Published by The Turkish Chemical Society in Journal of the Turkish Chemical Society Section A: Chemistry
- Vol. 5 (1) , 317-332
Electrochemical xanthine biosensor based on zinc oxide nanoparticles‒multiwalled carbon nanotubes‒1,4-benzoquinone composite
- 19 January 2018
- Published by The Turkish Chemical Society in Journal of the Turkish Chemical Society Section A: Chemistry
- Vol. 5 (1) , 317-332
Electrochemical xanthine biosensor based on zinc oxide nanoparticles‒multiwalled carbon nanotubes‒1,4-benzoquinone composite
- Open Access
- 16 January 2018
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 22 (2) , 832
Ksantin Biyosensörlerin Performansına Çeşitli Çok Duvarlı Karbon Nanotüplerin Etkisi
Bu çalışmada, fonksiyonel grup içermeyen (MWCNT) ve karboksil (COOH-MWCNT), hidroksil (OH-MWCNT) ve amino (NH2-MWCNT) grubu içeren çok duvarlı karbon nanotüplerin amperometrik ksantin biyosensörünün cevabına etkileri incelendi. Bu amaçla, MWCNT’ler ve ksantin oksidaz (XO) enzimi jelatin çözeltisi içinde dağıtıldı ve bu karışımlardan belirli miktarların camsı karbon elektrot yüzeyine damlatılması ile ksantin biyosensörleri hazırlandı. Bu biyosensörlerin optimum pH, enzim miktarı gibi çalışma koşulları belirlendi ve bu koşullarda biyosensörlerin performans faktörleri incelendi. NH2-MWCNT ile hazırlanan biyosensörün en yüksek duyarlık ile ksantine cevap verdiği gözlendi. Bu biyosensör ksantine -7 M – 9,4×10-4 M aralığında doğrusal cevap gösterdi ve gözlenebilme sınırı 8,7×10-7 M, duyarlığı 23,36 µA mM-1 olarak belirlendi.
- 16 January 2018
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 22 (2) , 832
Open AccessKsantin Biyosensörlerin Performansına Çeşitli Çok Duvarlı Karbon Nanotüplerin Etkisi
Bu çalışmada, fonksiyonel grup içermeyen (MWCNT) ve karboksil (COOH-MWCNT), hidroksil (OH-MWCNT) ve amino (NH2-MWCNT) grubu içeren çok duvarlı karbon nanotüplerin amperometrik ksantin biyosensörünün cevabına etkileri incelendi. Bu amaçla, MWCNT’ler ve ksantin oksidaz (XO) enzimi jelatin çözeltisi içinde dağıtıldı ve bu karışımlardan belirli miktarların camsı karbon elektrot yüzeyine damlatılması ile ksantin biyosensörleri hazırlandı. Bu biyosensörlerin optimum pH, enzim miktarı gibi çalışma koşulları belirlendi ve bu koşullarda biyosensörlerin performans faktörleri incelendi. NH2-MWCNT ile hazırlanan biyosensörün en yüksek duyarlık ile ksantine cevap verdiği gözlendi. Bu biyosensör ksantine -7 M – 9,4×10-4 M aralığında doğrusal cevap gösterdi ve gözlenebilme sınırı 8,7×10-7 M, duyarlığı 23,36 µA mM-1 olarak belirlendi.
- 1 January 2014
- Vol. 61 (1) , 19-26
Amperometric biosensor for xanthine determination based on Fe3O4 nanoparticles.
An amperometric xanthine biosensor was developed based on the immobilization of xanthine oxidase (XO) into the Fe3O4 nanoparticles modified carbon paste. Electron transfer properties of unmodified and Fe3O4 nanoparticles modified carbon paste electrodes were investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Fe3O4 nanoparticles increased electroactive surface area of the electrode and electron transfer at solution/electrode interface. Optimum pH, nanoparticle loading and enzyme loading were found to be 6.0; 14.2% and 0.6 Unit XO respectively. Fe3O4 nanoparticles modified carbon paste enzyme electrode allowed xanthine determination at -0.20 V, thus minimizing the potential interferences from electrochemically oxidizable substances such as ascorbic acid and uric acid. A linear relationship was obtained in the concentration range from 7.4 × 10-7 mol L-1 to 7.5 × 10-5 mol L-1 and a detection limit of 2.0 × 10-7 mol L-1. The biosensor was used for determination of xanthine in urine samples and the results indicate that the biosensor is effective for the detection of xanthine.
- 1 January 2014
- Vol. 61 (1) , 19-26
Amperometric biosensor for xanthine determination based on Fe3O4 nanoparticles.
An amperometric xanthine biosensor was developed based on the immobilization of xanthine oxidase (XO) into the Fe3O4 nanoparticles modified carbon paste. Electron transfer properties of unmodified and Fe3O4 nanoparticles modified carbon paste electrodes were investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Fe3O4 nanoparticles increased electroactive surface area of the electrode and electron transfer at solution/electrode interface. Optimum pH, nanoparticle loading and enzyme loading were found to be 6.0; 14.2% and 0.6 Unit XO respectively. Fe3O4 nanoparticles modified carbon paste enzyme electrode allowed xanthine determination at -0.20 V, thus minimizing the potential interferences from electrochemically oxidizable substances such as ascorbic acid and uric acid. A linear relationship was obtained in the concentration range from 7.4 × 10-7 mol L-1 to 7.5 × 10-5 mol L-1 and a detection limit of 2.0 × 10-7 mol L-1. The biosensor was used for determination of xanthine in urine samples and the results indicate that the biosensor is effective for the detection of xanthine.
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (7) , 1931-1937
Electrochemical Behavior of Trazodone at Mercury and Glassy Carbon Electrodes and Voltammetric Methods for its Determination
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (7) , 1931-1937
Electrochemical Behavior of Trazodone at Mercury and Glassy Carbon Electrodes and Voltammetric Methods for its Determination