Pınar Esra Erden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pınar Esra Erden has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Esma Kılıç
Department of Chemistry, Faculty of Science, Ankara University, Ankara, Turkey
13 shared publications Esma Kılıç
Department of Chemistry, Faculty of Science, Ankara University, Ankara, Turkey
10 shared publicationsCeren Kaçar
Department of Chemistry, Faculty of Science, Ankara University, 06100, Ankara, Turkey
9 shared publicationsFunda Öztürk
Department of Chemistry, Faculty of Science and Arts, Tekirdağ Namık Kemal University, Tekirdağ, Turkey
6 shared publications- Berna Dalkiran
Ankara University, Faculty of Science, Department of Chemistry, Ankara, Turkey
5 shared publications - Ceren Kaçar
Department of Chemistry, Faculty of Science, Ankara University, Ankara, TURKIYE
5 shared publications
Latest Publications
- 15 July 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
Electrochemical determination of the synthetic antioxidant propyl gallate in foodstuffs using a graphene, gold nanoparticles, and poly(L-serine)-based sensor.
In this study, an electrochemical sensor based on graphene (GR)-, gold nanoparticles (AuNPs)-, and poly(L-serine) (PSer)-modified glassy carbon electrode (GCE) was reported for the efficient determination of the synthetic antioxidant propyl gallate (PG) in foodstuffs. The surface composition of the working electrode was optimized using the one-factor-at-a-time method. The surface morphology of the PSer/AuNPs/GR/GCE was examined using the scanning electron microscopy (SEM) technique. To evaluate the electrochemical characteristics of the sensor, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) studies were carried out. Linear range, detection limit, and sensitivity of the PSer/AuNPs/GR/GCE were determined by differential pulse voltammetry (DPV) and found to be 6.1 × 10-7-5.7 × 10-5 M, 1.0 × 10-7 M, and 152.4 µA mM-1, respectively. Moreover, the sensor demonstrated high fabrication reproducibility and good operational stability. The PSer/AuNPs/GR/GCE was successfully utilized to determine PG in olive oil samples, and recoveries between 100 and 102% were obtained. Moreover, the obtained results showed good agreement with HPLC analysis demonstrating the applicability of the developed sensor for PG determination in foodstuffs.
- 15 July 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
Electrochemical determination of the synthetic antioxidant propyl gallate in foodstuffs using a graphene, gold nanoparticles, and poly(L-serine)-based sensor.
In this study, an electrochemical sensor based on graphene (GR)-, gold nanoparticles (AuNPs)-, and poly(L-serine) (PSer)-modified glassy carbon electrode (GCE) was reported for the efficient determination of the synthetic antioxidant propyl gallate (PG) in foodstuffs. The surface composition of the working electrode was optimized using the one-factor-at-a-time method. The surface morphology of the PSer/AuNPs/GR/GCE was examined using the scanning electron microscopy (SEM) technique. To evaluate the electrochemical characteristics of the sensor, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) studies were carried out. Linear range, detection limit, and sensitivity of the PSer/AuNPs/GR/GCE were determined by differential pulse voltammetry (DPV) and found to be 6.1 × 10-7-5.7 × 10-5 M, 1.0 × 10-7 M, and 152.4 µA mM-1, respectively. Moreover, the sensor demonstrated high fabrication reproducibility and good operational stability. The PSer/AuNPs/GR/GCE was successfully utilized to determine PG in olive oil samples, and recoveries between 100 and 102% were obtained. Moreover, the obtained results showed good agreement with HPLC analysis demonstrating the applicability of the developed sensor for PG determination in foodstuffs.
- 21 January 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 688, 115464
Disposable biosensor based on nanodiamond particles, ionic liquid and poly-l-lysine for determination of phenolic compounds
- 21 January 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 688, 115464
Disposable biosensor based on nanodiamond particles, ionic liquid and poly-l-lysine for determination of phenolic compounds
- Open Access
- 1 January 2023
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 47 (1) , 126-136
Electrochemical determination of aripiprazole based on aluminium oxide nanoparticles modified carbon paste electrode
The electrochemical oxidation of aripiprazole was explored at a carbon paste electrode modified with aluminium oxide nanoparticles by cyclic voltammetry and square-wave anodic adsorptive stripping voltammetry. Experimental parameters such as carbon paste composition, scan rate, buffer pH, accumulation time, and accumulation potential were optimized in order to obtain high analytical performance. The incorporation of aluminium oxide nanoparticles into the carbon paste matrix enhanced the effective surface area of the carbon paste electrode and improved the sensitivity. On the aluminium oxide nanoparticles modified carbon paste electrode, aripiprazole exhibited an irreversible anodic peak at +1.17 V in pH 1.8 BR buffer solution. Under optimum conditions, the peak current exhibited a linear dependence with aripiprazole concentration between 0.03 and 8.0 μM with a detection limit of 0.006 μM. The analytical applicability of the voltammetric method was evaluated by quantification of ARP in human serum samples and pharmaceutical formulations.
- 1 January 2023
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 47 (1) , 126-136
Open AccessElectrochemical determination of aripiprazole based on aluminium oxide nanoparticles modified carbon paste electrode
The electrochemical oxidation of aripiprazole was explored at a carbon paste electrode modified with aluminium oxide nanoparticles by cyclic voltammetry and square-wave anodic adsorptive stripping voltammetry. Experimental parameters such as carbon paste composition, scan rate, buffer pH, accumulation time, and accumulation potential were optimized in order to obtain high analytical performance. The incorporation of aluminium oxide nanoparticles into the carbon paste matrix enhanced the effective surface area of the carbon paste electrode and improved the sensitivity. On the aluminium oxide nanoparticles modified carbon paste electrode, aripiprazole exhibited an irreversible anodic peak at +1.17 V in pH 1.8 BR buffer solution. Under optimum conditions, the peak current exhibited a linear dependence with aripiprazole concentration between 0.03 and 8.0 μM with a detection limit of 0.006 μM. The analytical applicability of the voltammetric method was evaluated by quantification of ARP in human serum samples and pharmaceutical formulations.
- 5 December 2022
- Published by Elsevier in Analytical Biochemistry
- Vol. 662, 115002
Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A
- 5 December 2022
- Published by Elsevier in Analytical Biochemistry
- Vol. 662, 115002
Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol A
- 12 June 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (22) , 5315-5327
An amperometric biosensor based on poly(l-aspartic acid), nanodiamond particles, carbon nanofiber, and ascorbate oxidase–modified glassy carbon electrode for the determination of l-ascorbic acid
An amperometric l-ascorbic acid biosensor utilizing ascorbate oxidase (AOx) immobilized onto poly(l-aspartic acid) (P(l-Asp)) film was fabricated on carbon nanofiber (CNF) and nanodiamond particle (ND)-modified glassy carbon electrode (GCE). Effects of AOx, ND, and CNF amounts were investigated by monitoring the response currents of the biosensor at different amounts of AOx, ND, and CNF. The electropolymerization step of l-aspartic acid on CNF-ND/GCE surface was also optimized. Scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques were used to enlighten the modification steps of the biosensor. The effects of pH and applied potential were studied in detail to achieve the best analytical performance. Under optimized experimental conditions, the AOx/P(L-Asp)/ND-CNF/GCE biosensor showed a linear response to l-ascorbic acid in the range of 2.0 × 10−7–1.8 × 10−3 M with a detection limit of 1.0 × 10−7 M and sensitivity of 105.0 μAmM−1 cm−2. The novel biosensing platform showed good reproducibility and selectivity. The strong interaction between AOx and the P(l-Asp)/ND-CNF matrix was revealed by the high repeatability (3.4%) and good operational stability. The AOx/P(l-Asp)/ND-CNF/GCE biosensor was successfully applied to the determination of l-ascorbic acid in vitamin C effervescent tablet and pharmaceutical powder containing ascorbic acid with good results, which makes it a promising approach for quantification of l-ascorbic acid. Graphical abstract
- 12 June 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (22) , 5315-5327
An amperometric biosensor based on poly(l-aspartic acid), nanodiamond particles, carbon nanofiber, and ascorbate oxidase–modified glassy carbon electrode for the determination of l-ascorbic acid
An amperometric l-ascorbic acid biosensor utilizing ascorbate oxidase (AOx) immobilized onto poly(l-aspartic acid) (P(l-Asp)) film was fabricated on carbon nanofiber (CNF) and nanodiamond particle (ND)-modified glassy carbon electrode (GCE). Effects of AOx, ND, and CNF amounts were investigated by monitoring the response currents of the biosensor at different amounts of AOx, ND, and CNF. The electropolymerization step of l-aspartic acid on CNF-ND/GCE surface was also optimized. Scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques were used to enlighten the modification steps of the biosensor. The effects of pH and applied potential were studied in detail to achieve the best analytical performance. Under optimized experimental conditions, the AOx/P(L-Asp)/ND-CNF/GCE biosensor showed a linear response to l-ascorbic acid in the range of 2.0 × 10−7–1.8 × 10−3 M with a detection limit of 1.0 × 10−7 M and sensitivity of 105.0 μAmM−1 cm−2. The novel biosensing platform showed good reproducibility and selectivity. The strong interaction between AOx and the P(l-Asp)/ND-CNF matrix was revealed by the high repeatability (3.4%) and good operational stability. The AOx/P(l-Asp)/ND-CNF/GCE biosensor was successfully applied to the determination of l-ascorbic acid in vitamin C effervescent tablet and pharmaceutical powder containing ascorbic acid with good results, which makes it a promising approach for quantification of l-ascorbic acid. Graphical abstract
- 19 February 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (8) , 1933-1946
Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase– or monoamine oxidase–modified electrodes
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 × 10−6–6.9 × 10−4 M with a sensitivity of 1.84 μA mM−1. On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
- 19 February 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (8) , 1933-1946
Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase– or monoamine oxidase–modified electrodes
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 × 10−6–6.9 × 10−4 M with a sensitivity of 1.84 μA mM−1. On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
- 31 July 2019
- Published by Wiley in Electroanalysis
- Vol. 31 (12) , 2368-2378
Amperometric Biosensors for Tyramine Determination Based on Graphene Oxide and Polyvinylferrocene Modified Screen‐printed Electrodes
A comparison of the analytical characteristics of two tyramine biosensors, based on graphene oxide (GRO) and polyvinylferrocene (PVF) modified screen‐printed carbon electrodes (SPCE), is reported. Diamine oxidase (DAOx) or monoamine oxidase (MAOx) was immobilized onto the PVF/GRO modified SPCE to fabricate the biosensors. Surface characteristics and electrochemical behaviour of the modified SPCEs were investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy dispersive X‐ray spectroscopy (EDX) and cyclic voltammetry (CV). Electrode surface composition and experimental variables such as pH and working potential were optimized in order to ensure a high performance. Under optimum experimental conditions, both DAOx/PVF/GRO/SPCE and MAOx/PVF/GRO/SPCE biosensors exhibited wide linear dynamic ranges for tyramine from 9.9×10−7 to 1.2×10−4 M and from 9.9×10−7 to 1.1×10−4 M, respectively. MAOx/PVF/GRO/SPCE biosensor showed higher sensitivity (11.98 μA mM−1) for tyramine determination than the DAOx/PVF/GRO/SPCE biosensor (7.99 μA mM−1). The substrate specifity of the biosensors to other biogenic amines namely histamine, putrescine, spermine, spermidine, tryptamine, β‐phenylethylamine and cadaverine was also investigated. The developed biosensors were successfully used for tyramine determination in cheese sample.
- 31 July 2019
- Published by Wiley in Electroanalysis
- Vol. 31 (12) , 2368-2378
Amperometric Biosensors for Tyramine Determination Based on Graphene Oxide and Polyvinylferrocene Modified Screen‐printed Electrodes
A comparison of the analytical characteristics of two tyramine biosensors, based on graphene oxide (GRO) and polyvinylferrocene (PVF) modified screen‐printed carbon electrodes (SPCE), is reported. Diamine oxidase (DAOx) or monoamine oxidase (MAOx) was immobilized onto the PVF/GRO modified SPCE to fabricate the biosensors. Surface characteristics and electrochemical behaviour of the modified SPCEs were investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy dispersive X‐ray spectroscopy (EDX) and cyclic voltammetry (CV). Electrode surface composition and experimental variables such as pH and working potential were optimized in order to ensure a high performance. Under optimum experimental conditions, both DAOx/PVF/GRO/SPCE and MAOx/PVF/GRO/SPCE biosensors exhibited wide linear dynamic ranges for tyramine from 9.9×10−7 to 1.2×10−4 M and from 9.9×10−7 to 1.1×10−4 M, respectively. MAOx/PVF/GRO/SPCE biosensor showed higher sensitivity (11.98 μA mM−1) for tyramine determination than the DAOx/PVF/GRO/SPCE biosensor (7.99 μA mM−1). The substrate specifity of the biosensors to other biogenic amines namely histamine, putrescine, spermine, spermidine, tryptamine, β‐phenylethylamine and cadaverine was also investigated. The developed biosensors were successfully used for tyramine determination in cheese sample.
- Open Access
- 15 May 2019
- Published by The Turkish Chemical Society in Journal of the Turkish Chemical Society Section A: Chemistry
- Vol. 6 (1) , 79-88
Doping Agent Naphazoline Hydrochloride: Development of Simple and Fast Voltammetric Method for Its Determination in Human Serum
Electrochemical behavior of naphazoline hydrochloride on a carbon paste electrode that was modified with aluminium oxide nanoparticles (Al2O3NPs) was investigated in a Britton-Robinson (BR) buffer (pH 7.0) using various voltammetric techniques. The results support the presence of an irreversible and diffusion-controlled electrochemical oxidation signal of naphazoline hydrochloride which is approximately at 0.9 V vs. Ag/AgCl. A selective, accurate, and simple square-wave anodic adsorptive stripping voltammetric method was purposed for naphazoline hydrochloride detection. The linear response was within the range of 5.0 × 10-8- 3.0 × 10-5 mol L-1 with a detection limit of 2.6 × 10–8 mol L–1 (0.0064 mg L–1). In addition, the purposed method was also utilized for naphazoline hydrochloride determination in human serum sample.
- 15 May 2019
- Published by The Turkish Chemical Society in Journal of the Turkish Chemical Society Section A: Chemistry
- Vol. 6 (1) , 79-88
Open AccessDoping Agent Naphazoline Hydrochloride: Development of Simple and Fast Voltammetric Method for Its Determination in Human Serum
Electrochemical behavior of naphazoline hydrochloride on a carbon paste electrode that was modified with aluminium oxide nanoparticles (Al2O3NPs) was investigated in a Britton-Robinson (BR) buffer (pH 7.0) using various voltammetric techniques. The results support the presence of an irreversible and diffusion-controlled electrochemical oxidation signal of naphazoline hydrochloride which is approximately at 0.9 V vs. Ag/AgCl. A selective, accurate, and simple square-wave anodic adsorptive stripping voltammetric method was purposed for naphazoline hydrochloride detection. The linear response was within the range of 5.0 × 10-8- 3.0 × 10-5 mol L-1 with a detection limit of 2.6 × 10–8 mol L–1 (0.0064 mg L–1). In addition, the purposed method was also utilized for naphazoline hydrochloride determination in human serum sample.
- 19 December 2018
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (7) , 5381-5398
Effect of hexaammineruthenium chloride and/or horseradish peroxidase on the performance of hydrogen peroxide (bio)sensors: a comparative study
- 19 December 2018
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (7) , 5381-5398
Effect of hexaammineruthenium chloride and/or horseradish peroxidase on the performance of hydrogen peroxide (bio)sensors: a comparative study
- 22 November 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (2) , 413-425
Application of central composite design for the optimization of electrode surface composition for glucose biosensor fabrication
The use of a central composite design (CCD) for the optimization of electrode surface composition and its application to develop an amperometric glucose biosensor as a model system are described. A five-level three-factorial CCD was applied to determine the optimum electrode surface composition for three critical variables: amounts of carboxylated multiwall carbon nanotubes (c-MWCNT), titanium dioxide nanoparticles (TiO2NP), and glucose oxidase (GOx). The statistical significance of the model and factors were evaluated using the variance analysis (ANOVA) at 95% of confidence level. The optimized electrode surface composition was used for the fabrication of the glucose biosensor. The resulting biosensor showed linear response to glucose from 2.0 × 10−5 to 1.9 × 10−3 M with a detection limit of 2.1 × 10−6 M and sensitivity of 168.5 μA mM−1 cm−2 under optimal experimental conditions. Analytical performance parameters of the biosensor were also compared with those obtained with the glucose biosensors fabricated using the electrode compositions optimized by conventional one factor-at-a-time method and 22 CCD (for c-MWCNT and TiO2NP amounts). The optimization of the critical variables, achieved by CDD, leads us to fabricate the glucose biosensor in the best electrode surface composition which was promoted by the improved analytical performance. The proposed biosensor was applied to the analysis of glucose in serum samples and the obtained results were well correlated with the results of reference method.
- 22 November 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (2) , 413-425
Application of central composite design for the optimization of electrode surface composition for glucose biosensor fabrication
The use of a central composite design (CCD) for the optimization of electrode surface composition and its application to develop an amperometric glucose biosensor as a model system are described. A five-level three-factorial CCD was applied to determine the optimum electrode surface composition for three critical variables: amounts of carboxylated multiwall carbon nanotubes (c-MWCNT), titanium dioxide nanoparticles (TiO2NP), and glucose oxidase (GOx). The statistical significance of the model and factors were evaluated using the variance analysis (ANOVA) at 95% of confidence level. The optimized electrode surface composition was used for the fabrication of the glucose biosensor. The resulting biosensor showed linear response to glucose from 2.0 × 10−5 to 1.9 × 10−3 M with a detection limit of 2.1 × 10−6 M and sensitivity of 168.5 μA mM−1 cm−2 under optimal experimental conditions. Analytical performance parameters of the biosensor were also compared with those obtained with the glucose biosensors fabricated using the electrode compositions optimized by conventional one factor-at-a-time method and 22 CCD (for c-MWCNT and TiO2NP amounts). The optimization of the critical variables, achieved by CDD, leads us to fabricate the glucose biosensor in the best electrode surface composition which was promoted by the improved analytical performance. The proposed biosensor was applied to the analysis of glucose in serum samples and the obtained results were well correlated with the results of reference method.