Hong Kuan Kok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hong Kuan Kok has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Hamed Asadi
Department of Neuroradiology, Austin Health, Melbourne, Victoria, Australia
5 shared publications - Julian Maingard
Department of Interventional Neuroradiology, Austin Health, Heidelberg, Melbourne, Australia
4 shared publications - Goran Mitreski
Interventional Radiology Service, Northern Imaging Victoria, Northern Health, Melbourne, Australia
3 shared publications Hamed Asadi
Interventional Radiology Service, Department of Radiology, Austin Health, Melbourne, Australia; Interventional Radiology, Department of Radiology, St. Vincent's Health, Melbourne, Victoria, Australia; Interventional Radiology, Department of Imaging, Monash University, Melbourne, Victoria, Australia
3 shared publications- Michelle Foo
Interventional Neuroradiology Unit, Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia
3 shared publications - Ashu Jhamb
Department of Radiology, Interventional Neuroradiology Service, St. Vincent’s Hospital, Melbourne, VIC, Australia
2 shared publications
Latest Publications
- Open Access
- 27 March 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (7) , 108762
Quality of Life Following Endovascular Treatment of Proximal Lower Limb Deep Vein Thrombosis: A Systematic Review and Meta-Analysis
- 27 March 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (7) , 108762
Open AccessQuality of Life Following Endovascular Treatment of Proximal Lower Limb Deep Vein Thrombosis: A Systematic Review and Meta-Analysis
- Open Access
- 6 February 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8 (1) , 1-5
Percutaneous large-bore mechanical thrombectomy for macroscopic fat pulmonary embolism: a case report
Background: Macroscopic fat pulmonary embolism is extremely uncommon. Most cases occur in the context of fat grafting or long bone fractures. Macroscopic fat pulmonary embolism may be associated with cardiopulmonary compromise and is associated with high mortality. Mechanical thrombectomy is an emerging technique in interventional radiology, primarily investigated as a therapeutic approach for thrombotic pulmonary embolism. Case presentation: We present a case report of a 73-year-old woman with macroscopic fat pulmonary embolism after a neck of femur fracture. Initially, she had severe circulatory shock, requiring multiple vasopressors and admission to the Intensive Care Unit. A percutaneous large-bore mechanical thrombectomy was performed, after which notable improvements to haemodynamic function and overall clinical trajectory were observed. Conclusions: To our knowledge, this is the first report of mechanical thrombectomy in macroscopic fat pulmonary embolism. Further research is required to better delineate the role of mechanical thrombectomy in this rare condition.
- 6 February 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8 (1) , 1-5
Open AccessPercutaneous large-bore mechanical thrombectomy for macroscopic fat pulmonary embolism: a case report
Background: Macroscopic fat pulmonary embolism is extremely uncommon. Most cases occur in the context of fat grafting or long bone fractures. Macroscopic fat pulmonary embolism may be associated with cardiopulmonary compromise and is associated with high mortality. Mechanical thrombectomy is an emerging technique in interventional radiology, primarily investigated as a therapeutic approach for thrombotic pulmonary embolism. Case presentation: We present a case report of a 73-year-old woman with macroscopic fat pulmonary embolism after a neck of femur fracture. Initially, she had severe circulatory shock, requiring multiple vasopressors and admission to the Intensive Care Unit. A percutaneous large-bore mechanical thrombectomy was performed, after which notable improvements to haemodynamic function and overall clinical trajectory were observed. Conclusions: To our knowledge, this is the first report of mechanical thrombectomy in macroscopic fat pulmonary embolism. Further research is required to better delineate the role of mechanical thrombectomy in this rare condition.
- 16 April 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (8) , 1127-1138
A Qualitative Systematic Review of Endovascular Management of Renal Artery Aneurysms
- 16 April 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (8) , 1127-1138
A Qualitative Systematic Review of Endovascular Management of Renal Artery Aneurysms
- 29 March 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (7) , 1200-1213
Radioembolization for Treatment of Hepatocellular Carcinoma: Current Evidence and Patterns of Utilization
- 29 March 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (7) , 1200-1213
Radioembolization for Treatment of Hepatocellular Carcinoma: Current Evidence and Patterns of Utilization
- Open Access
- 1 November 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (3) , 260-266
CaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection
Purpose: Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS–the CaRotid Artery Filtering Technique (CRAFT).Materials and Methods: The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.Results: A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.Conclusion: The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.
- 1 November 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (3) , 260-266
Open AccessCaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection
Purpose: Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS–the CaRotid Artery Filtering Technique (CRAFT).Materials and Methods: The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.Results: A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.Conclusion: The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.
- Open Access
- 30 September 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (9) , e244380
Intrahepatic migration of pancreatic stent after pancreaticoduodenectomy: percutaneous cholangioscopic retrieval is feasible
Herein, we describe a case where a pancreatic stent had migrated into a segment VI intrahepatic duct following a pancreaticoduodenectomy.
- 30 September 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (9) , e244380
Open AccessIntrahepatic migration of pancreatic stent after pancreaticoduodenectomy: percutaneous cholangioscopic retrieval is feasible
Herein, we describe a case where a pancreatic stent had migrated into a segment VI intrahepatic duct following a pancreaticoduodenectomy.
- 29 July 2021
- Published by Wiley in Journal of Digestive Diseases
- Vol. 22 (9) , 506-519
Transjugular intrahepatic portosystemic shunts in portal vein thrombosis: A review
The presence of portal vein thrombosis (PVT) has previously been considered a contraindication to the insertion of transjugular intrahepatic portosystemic shunts (TIPSS). However, patients with PVT may have portal hypertension complications and may thus benefit from TIPSS to reduce portal venous pressure. There is an increasing body of literature that discusses the techniques and outcomes of TIPSS in PVT. This review summarizes the techniques, indications and outcomes of TIPSS in PVT in published case reports, case series and comparative trials, especially regarding the reduction in portal hypertensive complications such as variceal bleeding. A comprehensive literature search was conducted using MEDLINE and PubMed databases. Manuscripts published in English between 1 January 1990 and 1 March 2021 were used. Abstracts were screened and data from potentially relevant articles analyzed. TIPSS in PVT has been reported with high levels of technical success, short‐term portal vein recanalization and long‐term PV patency and TIPSS patency outcomes. Several comparative studies, including randomized controlled trials, have shown favorable outcomes of TIPSS compared with non‐TIPSS treatment of PVT complications. Outcomes of TIPSS with PVT appear similar to those in TIPSS without PVT. However, TIPSS may be more technically difficult in the presence of PVT, and such procedures should be performed in expert high‐volume centers to mitigate the risk of procedural complications. The presence of PVT should no longer be considered a contraindication to TIPSS. TIPSS for PVT has been acknowledged as a therapeutic strategy in recent international guidelines, although further studies are needed before recommendations can be strengthened.Key Points: Portal vein thrombosis (PVT) is no longer a contraindication to the insertion of transjugular intrahepatic portosystemic shunts (TIPSS) TIPSS often leads to the spontaneous dissolution of PVT, but can be combined with mechanical or pharmacological thrombectomy TIPSS reduces portal hypertensive complications of PVT, such as variceal bleeding, and can also facilitate liver transplantation where PVT may otherwise interfere with vascular anastomoses Studies have shown favorable long‐term outcomes of TIPSS compared with TIPSS without PVT; as well as compared with non‐TIPSS treatment of PVT complications TIPSS in PVT should be performed in high‐volume specialist centers due to technical difficulties
- 29 July 2021
- Published by Wiley in Journal of Digestive Diseases
- Vol. 22 (9) , 506-519
Transjugular intrahepatic portosystemic shunts in portal vein thrombosis: A review
The presence of portal vein thrombosis (PVT) has previously been considered a contraindication to the insertion of transjugular intrahepatic portosystemic shunts (TIPSS). However, patients with PVT may have portal hypertension complications and may thus benefit from TIPSS to reduce portal venous pressure. There is an increasing body of literature that discusses the techniques and outcomes of TIPSS in PVT. This review summarizes the techniques, indications and outcomes of TIPSS in PVT in published case reports, case series and comparative trials, especially regarding the reduction in portal hypertensive complications such as variceal bleeding. A comprehensive literature search was conducted using MEDLINE and PubMed databases. Manuscripts published in English between 1 January 1990 and 1 March 2021 were used. Abstracts were screened and data from potentially relevant articles analyzed. TIPSS in PVT has been reported with high levels of technical success, short‐term portal vein recanalization and long‐term PV patency and TIPSS patency outcomes. Several comparative studies, including randomized controlled trials, have shown favorable outcomes of TIPSS compared with non‐TIPSS treatment of PVT complications. Outcomes of TIPSS with PVT appear similar to those in TIPSS without PVT. However, TIPSS may be more technically difficult in the presence of PVT, and such procedures should be performed in expert high‐volume centers to mitigate the risk of procedural complications. The presence of PVT should no longer be considered a contraindication to TIPSS. TIPSS for PVT has been acknowledged as a therapeutic strategy in recent international guidelines, although further studies are needed before recommendations can be strengthened.Key Points: Portal vein thrombosis (PVT) is no longer a contraindication to the insertion of transjugular intrahepatic portosystemic shunts (TIPSS) TIPSS often leads to the spontaneous dissolution of PVT, but can be combined with mechanical or pharmacological thrombectomy TIPSS reduces portal hypertensive complications of PVT, such as variceal bleeding, and can also facilitate liver transplantation where PVT may otherwise interfere with vascular anastomoses Studies have shown favorable long‐term outcomes of TIPSS compared with TIPSS without PVT; as well as compared with non‐TIPSS treatment of PVT complications TIPSS in PVT should be performed in high‐volume specialist centers due to technical difficulties
- Open Access
- 1 July 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (2) , 122-131
Endovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience
Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
- 1 July 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (2) , 122-131
Open AccessEndovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience
Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
- 17 August 2020
- Published by Elsevier in Clinical Radiology
- Vol. 75 (12) , 960.e23-960.e34
Contemporary endovascular management of splenic vascular pathologies
- 17 August 2020
- Published by Elsevier in Clinical Radiology
- Vol. 75 (12) , 960.e23-960.e34
Contemporary endovascular management of splenic vascular pathologies
- 10 January 2020
- Published by Springer Nature
- p. 235-240
Tutorial 15: Emerging Imaging Technologies