Ashu Jhamb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ashu Jhamb has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Hamed Asadi
Department of Neuroradiology, Austin Health, Melbourne, Victoria, Australia
4 shared publications - Yifan Ren
Department of Neuroradiology, Austin Health, Melbourne, Victoria, Australia
4 shared publications - Duncan Mark Brooks
Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia; School of Medicine, Deakin University, Melbourne, Australia
3 shared publications - Julian Maingard
Department of Interventional Neuroradiology, Austin Health, Heidelberg, Melbourne, Australia
3 shared publications - Michelle Foo
Interventional Neuroradiology Unit, Austin Health, 145 Studley Rd, Heidelberg, VIC 3084, Australia
3 shared publications - Hong Kuan Kok
Interventional Radiology Service, Northern Imaging Victoria, Northern Health, Melbourne, Australia
2 shared publications
Latest Publications
- Open Access
- 1 March 2022
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 17 (1) , 28-36
The Woven EndoBridge Device for the Treatment of Intracranial Aneurysms: Initial Clinical Experience within an Australian Population
Purpose: Advances in endovascular technology have expanded the treatment options for intracranial aneurysms. Intrasaccular flow diversion is a relatively new technique that aims to disrupt blood inflow at the neck of the aneurysm, hence promoting intrasaccular thrombosis. The Woven EndoBridge device (WEB; MicroVention, Aliso Viejo, CA, USA) is an US Food and Drug Administration approved intrasaccular flow diverter for wide-necked aneurysms. We report the early interim clinical and radiological outcomes of patients with both ruptured and unruptured intracranial aneurysms (IAs) treated using the WEB device in an Australian population.Materials and Methods: A retrospective analysis was done of patients with ruptured or unruptured IAs who received treatment with WEB across 5 Australian neuroendovascular referral centers between May 2017 and November 2020. Angiographic occlusion was assessed with time-of-flight magnetic resonance angiography. Complications were recorded and clinical outcomes were assessed using the modified Rankin scale at follow-up.Results: In total, 66 aneurysms were treated in 63 patients, with successful deployment of the WEB device in 98.5% (n=65). Eighteen (26.9%) ruptured aneurysms were included. Failure of deployment occurred in a single case. Adjunct coiling and/or stenting was performed in 20.9% (n=14) cases. Sixty-two patients with 65 aneurysms using a WEB device were followed up (mean=9.1 months), and 89.4% of these had complete aneurysm occlusion while 1.5% remained patent. Functional independence was achieved in 93.5% of cases.Conclusion: Early results following the use of WEB devices in Australia demonstrate safety and adequate aneurysm occlusion comparable to international literature.
- 1 March 2022
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 17 (1) , 28-36
Open AccessThe Woven EndoBridge Device for the Treatment of Intracranial Aneurysms: Initial Clinical Experience within an Australian Population
Purpose: Advances in endovascular technology have expanded the treatment options for intracranial aneurysms. Intrasaccular flow diversion is a relatively new technique that aims to disrupt blood inflow at the neck of the aneurysm, hence promoting intrasaccular thrombosis. The Woven EndoBridge device (WEB; MicroVention, Aliso Viejo, CA, USA) is an US Food and Drug Administration approved intrasaccular flow diverter for wide-necked aneurysms. We report the early interim clinical and radiological outcomes of patients with both ruptured and unruptured intracranial aneurysms (IAs) treated using the WEB device in an Australian population.Materials and Methods: A retrospective analysis was done of patients with ruptured or unruptured IAs who received treatment with WEB across 5 Australian neuroendovascular referral centers between May 2017 and November 2020. Angiographic occlusion was assessed with time-of-flight magnetic resonance angiography. Complications were recorded and clinical outcomes were assessed using the modified Rankin scale at follow-up.Results: In total, 66 aneurysms were treated in 63 patients, with successful deployment of the WEB device in 98.5% (n=65). Eighteen (26.9%) ruptured aneurysms were included. Failure of deployment occurred in a single case. Adjunct coiling and/or stenting was performed in 20.9% (n=14) cases. Sixty-two patients with 65 aneurysms using a WEB device were followed up (mean=9.1 months), and 89.4% of these had complete aneurysm occlusion while 1.5% remained patent. Functional independence was achieved in 93.5% of cases.Conclusion: Early results following the use of WEB devices in Australia demonstrate safety and adequate aneurysm occlusion comparable to international literature.
- 17 December 2021
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (2) , E47-E49
International Study of Intracranial Aneurysm Treatment Using Woven EndoBridge: Results of the WorldWideWEB Consortium
- 17 December 2021
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (2) , E47-E49
International Study of Intracranial Aneurysm Treatment Using Woven EndoBridge: Results of the WorldWideWEB Consortium
- Open Access
- 1 November 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (3) , 260-266
CaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection
Purpose: Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS–the CaRotid Artery Filtering Technique (CRAFT).Materials and Methods: The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.Results: A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.Conclusion: The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.
- 1 November 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (3) , 260-266
Open AccessCaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection
Purpose: Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS–the CaRotid Artery Filtering Technique (CRAFT).Materials and Methods: The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.Results: A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.Conclusion: The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.
- Open Access
- 1 July 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (2) , 122-131
Endovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience
Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
- 1 July 2021
- Published by Korean Society of Interventional Neuroradiology in Neurointervention
- Vol. 16 (2) , 122-131
Open AccessEndovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience
Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
- 1 November 2016
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 27 (11) , 1722-1724
Bard DENALI Inferior Vena Cava Filter: Another “Arm” Fracture
- 1 November 2016
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 27 (11) , 1722-1724
Bard DENALI Inferior Vena Cava Filter: Another “Arm” Fracture
- 1 December 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (12) , 1860-1865
Percutaneous Placement of Permanent Metallic Stents in the Cystic Duct to Treat Obstructive Cholecystitis
- 1 December 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (12) , 1860-1865
Percutaneous Placement of Permanent Metallic Stents in the Cystic Duct to Treat Obstructive Cholecystitis