Mustafa Sinasi Ayas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mustafa Sinasi Ayas has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Erdinc Sahin
Computer Engineering Giresun University Giresun Türkiye
11 shared publications - Özay Can
Recep Tayyip Erdoğan University
7 shared publications Ismail Hakki Altas
Department of Electrical and Electronics Engineering, Karadeniz Technical University, Trabzon, Turkey
5 shared publicationsAli Kivanc Sahin
3 shared publications- Ali Kivanc Sahin
Department of Electrical Electronics Engineering, Faculty of Engineering, Erzurum Technical University, Erzurum, Turkey
3 shared publications - Babak Nahid-Mobarakeh
McMaster Automotive Resource Centre, McMaster University, Hamilton, ON, Canada
3 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by SAGE Publications in Journal of Low Frequency Noise, Vibration and Active Control
Optimal design of a predictive PI controller for integrating processes with time delay using the fata morgana algorithm
Integrating-plus-dead-time (IPTD) processes are difficult to control because they are non-self-regulating and sensitive to parameter uncertainty. This simulation study presents a constraint-aware tuning framework for a Predictive PI (PPI) controller. The Fata Morgana Algorithm (FATA) minimizes a penalty-augmented objective that combines ITAE with quadratic penalties on maximum overshoot ( M p ) and settling time ( t s ). Two IPTD benchmark systems are used to compare the proposed controller with published PI–PD and I–PD designs. Within these comparisons, the settling time decreases by up to 47.5%, while the objective value J decreases by up to 71.3%. Twenty independent FATA runs are performed for each benchmark to characterize the repeatability of the tuning results. Under the tested simultaneous ± 25% gain-and-delay perturbations, both the proposed controller and the corresponding published comparator exhibit bounded responses approaching the reference in each benchmark. In Benchmark II, the I–PD response under the +25% perturbation exhibits more pronounced, slowly decaying oscillations than the PPI response, rather than instability. These simulation results indicate improved nominal transient performance within the selected comparisons, but do not establish formal robustness margins.
- 19 October 2026
- Published by SAGE Publications in Journal of Low Frequency Noise, Vibration and Active Control
Open AccessOptimal design of a predictive PI controller for integrating processes with time delay using the fata morgana algorithm
Integrating-plus-dead-time (IPTD) processes are difficult to control because they are non-self-regulating and sensitive to parameter uncertainty. This simulation study presents a constraint-aware tuning framework for a Predictive PI (PPI) controller. The Fata Morgana Algorithm (FATA) minimizes a penalty-augmented objective that combines ITAE with quadratic penalties on maximum overshoot ( M p ) and settling time ( t s ). Two IPTD benchmark systems are used to compare the proposed controller with published PI–PD and I–PD designs. Within these comparisons, the settling time decreases by up to 47.5%, while the objective value J decreases by up to 71.3%. Twenty independent FATA runs are performed for each benchmark to characterize the repeatability of the tuning results. Under the tested simultaneous ± 25% gain-and-delay perturbations, both the proposed controller and the corresponding published comparator exhibit bounded responses approaching the reference in each benchmark. In Benchmark II, the I–PD response under the +25% perturbation exhibits more pronounced, slowly decaying oscillations than the PPI response, rather than instability. These simulation results indicate improved nominal transient performance within the selected comparisons, but do not establish formal robustness margins.
- 6 March 2026
- Published by Taylor & Francis in International Journal of Systems Science
- p. 1-21
A reinforcement learning-cooperated dynamic controller parameter optimisation for frequency control in a nonlinear power system
1. Frequency stability and management have become increasingly critical challenges in modern power systems, particularly with the increasing integration of renewable energy sources (RESs). The freq...
- 6 March 2026
- Published by Taylor & Francis in International Journal of Systems Science
- p. 1-21
A reinforcement learning-cooperated dynamic controller parameter optimisation for frequency control in a nonlinear power system
1. Frequency stability and management have become increasingly critical challenges in modern power systems, particularly with the increasing integration of renewable energy sources (RESs). The freq...
- Open Access
- 2 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Hippopotamus optimization–tuned sigmoid PID controller for load frequency control of a two-area thermal power system with renewable energy sources
The increasing penetration of renewable energy sources (RES) in modern interconnected power systems introduces significant challenges for load frequency control (LFC) due to increased nonlinearities, the governor dead-band (GDB) effect, parameter uncertainties, and continuous power fluctuations. These factors reduce the effectiveness of conventional fixed-gain controllers and make it difficult to maintain frequency and tie-line power deviations within acceptable limits under varying operating conditions. To address these limitations, this study proposes a sigmoid proportional-integral-derivative (SPID) controller for LFC in a two-area thermal power system integrated with RES. In the proposed approach, the controller gains are adaptively adjusted through a sigmoid-based nonlinear mapping, and the corresponding parameters are optimally tuned using the Hippopotamus Optimization (HO) algorithm by minimizing the Integral of Time-weighted Absolute Error (ITAE) performance index. The performance of the proposed HO-SPID controller is evaluated under four time-domain scenarios: a baseline case without GDB and RES, a GDB-inclusive case without RES, a case with variable RES effects, and a robustness analysis of the baseline system under simultaneous ± 25% and ± 50% variations in all system parameters. Additionally, to demonstrate the stability of the proposed controller, frequency-domain stability is examined using Bode analysis. Simulation results demonstrate that the proposed HO-SPID controller significantly outperforms state-of-the-art PID-based metaheuristic controllers in terms of ITAE minimization, settling time, and undershoot, while the robustness analysis under parameter uncertainties and the Bode-based frequency-domain assessment jointly confirm its stable operation.
- 2 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessHippopotamus optimization–tuned sigmoid PID controller for load frequency control of a two-area thermal power system with renewable energy sources
The increasing penetration of renewable energy sources (RES) in modern interconnected power systems introduces significant challenges for load frequency control (LFC) due to increased nonlinearities, the governor dead-band (GDB) effect, parameter uncertainties, and continuous power fluctuations. These factors reduce the effectiveness of conventional fixed-gain controllers and make it difficult to maintain frequency and tie-line power deviations within acceptable limits under varying operating conditions. To address these limitations, this study proposes a sigmoid proportional-integral-derivative (SPID) controller for LFC in a two-area thermal power system integrated with RES. In the proposed approach, the controller gains are adaptively adjusted through a sigmoid-based nonlinear mapping, and the corresponding parameters are optimally tuned using the Hippopotamus Optimization (HO) algorithm by minimizing the Integral of Time-weighted Absolute Error (ITAE) performance index. The performance of the proposed HO-SPID controller is evaluated under four time-domain scenarios: a baseline case without GDB and RES, a GDB-inclusive case without RES, a case with variable RES effects, and a robustness analysis of the baseline system under simultaneous ± 25% and ± 50% variations in all system parameters. Additionally, to demonstrate the stability of the proposed controller, frequency-domain stability is examined using Bode analysis. Simulation results demonstrate that the proposed HO-SPID controller significantly outperforms state-of-the-art PID-based metaheuristic controllers in terms of ITAE minimization, settling time, and undershoot, while the robustness analysis under parameter uncertainties and the Bode-based frequency-domain assessment jointly confirm its stable operation.
- 22 August 2025
- Published by Elsevier in Journal of Information Security and Applications
- Vol. 94
Detecting cyberattacks based on deep neural network approaches in industrial control systems
- 22 August 2025
- Published by Elsevier in Journal of Information Security and Applications
- Vol. 94
Detecting cyberattacks based on deep neural network approaches in industrial control systems
- 20 August 2025
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 48 (10) , 2414-2426
Enhancing automatic generation control in renewable energy-integrated thermal power systems with a novel PID+I λ controller tuned by INFO algorithm
Electrical systems need to balance generation and demand to ensure that customers are supplied with safe and high-quality electricity. Failure to maintain this balance may result in unwanted frequency oscillation and, accordingly, tie-line power variation. Automatic generation control (AGC) is an important mechanism for controlling system responses and keeping them within predetermined bounds. Integrating renewable energy sources (RESs) into the grid can be complicated due to their erratic and weather-dependent nature, leading to imbalances in generation and consumption. To reduce these disparities, this study focuses on developing a novel proportional–integral–derivative (PID)+I λ controller for the AGC in a two-area thermal power system utilizing wind turbines and photovoltaic (PV) panels as renewables. For achieving the best possible performance, the controller parameters are optimized using the weighted mean of vectors (INFO) algorithm. Simulation studies are conducted to evaluate the performance of the proposed controller under different load demands and RES scenarios. Comparative studies are also conducted to evaluate the true efficacy of the INFO-tuned PID+I λ controller against some published control schemes available in the literature. It is found that our proposal outperforms its rivals in mitigating the unwanted system oscillations, lessening the overshoot/undershoot, and shortening the settling time of frequency and tie-line power responses.
- 20 August 2025
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 48 (10) , 2414-2426
Enhancing automatic generation control in renewable energy-integrated thermal power systems with a novel PID+I λ controller tuned by INFO algorithm
Electrical systems need to balance generation and demand to ensure that customers are supplied with safe and high-quality electricity. Failure to maintain this balance may result in unwanted frequency oscillation and, accordingly, tie-line power variation. Automatic generation control (AGC) is an important mechanism for controlling system responses and keeping them within predetermined bounds. Integrating renewable energy sources (RESs) into the grid can be complicated due to their erratic and weather-dependent nature, leading to imbalances in generation and consumption. To reduce these disparities, this study focuses on developing a novel proportional–integral–derivative (PID)+I λ controller for the AGC in a two-area thermal power system utilizing wind turbines and photovoltaic (PV) panels as renewables. For achieving the best possible performance, the controller parameters are optimized using the weighted mean of vectors (INFO) algorithm. Simulation studies are conducted to evaluate the performance of the proposed controller under different load demands and RES scenarios. Comparative studies are also conducted to evaluate the true efficacy of the INFO-tuned PID+I λ controller against some published control schemes available in the literature. It is found that our proposal outperforms its rivals in mitigating the unwanted system oscillations, lessening the overshoot/undershoot, and shortening the settling time of frequency and tie-line power responses.
- 9 July 2025
- Published by Taylor & Francis in International Journal of Systems Science
- Vol. 57 (5) , 1221-1238
Performance enhancement of PI and PIDn controllers through deep reinforcement learning for frequency regulation in renewable-integrated power systems
- 9 July 2025
- Published by Taylor & Francis in International Journal of Systems Science
- Vol. 57 (5) , 1221-1238
Performance enhancement of PI and PIDn controllers through deep reinforcement learning for frequency regulation in renewable-integrated power systems
- 13 January 2025
- Published by Elsevier in International Journal of Critical Infrastructure Protection
- Vol. 48
OptAML: Optimized adversarial machine learning on water treatment and distribution systems
- 13 January 2025
- Published by Elsevier in International Journal of Critical Infrastructure Protection
- Vol. 48
OptAML: Optimized adversarial machine learning on water treatment and distribution systems
- Top Cited PapersOpen Access
- 7 May 2024
- Published by Springer Nature in Neural Computing and Applications
- Vol. 36 (23) , 14409-14431
An adaptive fractional controller design for automatic voltage regulator system: sigmoid-based fractional-order PID controller
The primary objective of a power system is to provide safe and reliable electrical energy to consumers. This objective is achieved by maintaining the stability of the power system, a multifaceted concept that can be divided into three distinct classes. The focus of this study is on one of these classes, voltage stability. A critical component in maintaining voltage stability is the automatic voltage regulator (AVR) system of synchronous generators. In this paper, a novel control method, the sigmoid-based fractional-order PID (SFOPID), is introduced with the aim of improving the dynamic response and the robustness of the AVR system. The dandelion optimizer (DO), a successful optimization algorithm, is used to optimize the parameters of the proposed SFOPID control strategy. The optimization process for the DO-SFOPID control strategy includes a variety of objective functions, including error-based metrics such as integral of absolute error, integral of squared error, integral of time absolute error, and integral of time squared error, in addition to the user-defined Zwee Lee Gaing’s metric. The effectiveness of the DO-SFOPID control technique on the AVR system has been rigorously investigated through a series of tests and analyses, including aspects such as time domain, robustness, frequency domain, and evaluation of nonlinearity effects. The simulation results are compared between the proposed DO-SFOPID control technique and the fractional-order PID (FOPID) and sigmoid-based PID (SPID) control techniques, both of which have been tuned using different metaheuristic algorithms that have gained significant recognition in recent years. As a result of these comparative analyses, the superiority of the DO-SFOPID control technique is confirmed as it shows an improved performance with respect to the other control techniques. Furthermore, the performance of the proposed DO-SFOPID control technique is validated within an experimental setup for the AVR system. The simulation results show that the proposed DO-SFOPID control technique is highly successful in terms of stability and robustness. In summary, this study provides comprehensive evidence supporting the effectiveness and superiority of the DO-SFOPID control technique on the AVR system through both simulation and experimental results.
- 7 May 2024
- Published by Springer Nature in Neural Computing and Applications
- Vol. 36 (23) , 14409-14431
Top Cited PapersOpen AccessAn adaptive fractional controller design for automatic voltage regulator system: sigmoid-based fractional-order PID controller
The primary objective of a power system is to provide safe and reliable electrical energy to consumers. This objective is achieved by maintaining the stability of the power system, a multifaceted concept that can be divided into three distinct classes. The focus of this study is on one of these classes, voltage stability. A critical component in maintaining voltage stability is the automatic voltage regulator (AVR) system of synchronous generators. In this paper, a novel control method, the sigmoid-based fractional-order PID (SFOPID), is introduced with the aim of improving the dynamic response and the robustness of the AVR system. The dandelion optimizer (DO), a successful optimization algorithm, is used to optimize the parameters of the proposed SFOPID control strategy. The optimization process for the DO-SFOPID control strategy includes a variety of objective functions, including error-based metrics such as integral of absolute error, integral of squared error, integral of time absolute error, and integral of time squared error, in addition to the user-defined Zwee Lee Gaing’s metric. The effectiveness of the DO-SFOPID control technique on the AVR system has been rigorously investigated through a series of tests and analyses, including aspects such as time domain, robustness, frequency domain, and evaluation of nonlinearity effects. The simulation results are compared between the proposed DO-SFOPID control technique and the fractional-order PID (FOPID) and sigmoid-based PID (SPID) control techniques, both of which have been tuned using different metaheuristic algorithms that have gained significant recognition in recent years. As a result of these comparative analyses, the superiority of the DO-SFOPID control technique is confirmed as it shows an improved performance with respect to the other control techniques. Furthermore, the performance of the proposed DO-SFOPID control technique is validated within an experimental setup for the AVR system. The simulation results show that the proposed DO-SFOPID control technique is highly successful in terms of stability and robustness. In summary, this study provides comprehensive evidence supporting the effectiveness and superiority of the DO-SFOPID control technique on the AVR system through both simulation and experimental results.