ASAli Kivanc Sahin

Ali Kivanc Sahin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ali Kivanc Sahin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hippopotamus optimization–tuned sigmoid PID controller for load frequency control of a two-area thermal power system with renewable energy sources

    by Özay Can, Mustafa Şinasi Ayas, Ali Kıvanç Şahin

    The increasing penetration of renewable energy sources (RES) in modern interconnected power systems introduces significant challenges for load frequency control (LFC) due to increased nonlinearities, the governor dead-band (GDB) effect, parameter uncertainties, and continuous power fluctuations. These factors reduce the effectiveness of conventional fixed-gain controllers and make it difficult to maintain frequency and tie-line power deviations within acceptable limits under varying operating conditions. To address these limitations, this study proposes a sigmoid proportional-integral-derivative (SPID) controller for LFC in a two-area thermal power system integrated with RES. In the proposed approach, the controller gains are adaptively adjusted through a sigmoid-based nonlinear mapping, and the corresponding parameters are optimally tuned using the Hippopotamus Optimization (HO) algorithm by minimizing the Integral of Time-weighted Absolute Error (ITAE) performance index. The performance of the proposed HO-SPID controller is evaluated under four time-domain scenarios: a baseline case without GDB and RES, a GDB-inclusive case without RES, a case with variable RES effects, and a robustness analysis of the baseline system under simultaneous ± 25% and ± 50% variations in all system parameters. Additionally, to demonstrate the stability of the proposed controller, frequency-domain stability is examined using Bode analysis. Simulation results demonstrate that the proposed HO-SPID controller significantly outperforms state-of-the-art PID-based metaheuristic controllers in terms of ITAE minimization, settling time, and undershoot, while the robustness analysis under parameter uncertainties and the Bode-based frequency-domain assessment jointly confirm its stable operation.


  • Top Cited Papers
    Open Access

    An adaptive fractional controller design for automatic voltage regulator system: sigmoid-based fractional-order PID controller

    by Ali Kivanc Sahin, Bora Cavdar, Mustafa Sinasi Ayas

    The primary objective of a power system is to provide safe and reliable electrical energy to consumers. This objective is achieved by maintaining the stability of the power system, a multifaceted concept that can be divided into three distinct classes. The focus of this study is on one of these classes, voltage stability. A critical component in maintaining voltage stability is the automatic voltage regulator (AVR) system of synchronous generators. In this paper, a novel control method, the sigmoid-based fractional-order PID (SFOPID), is introduced with the aim of improving the dynamic response and the robustness of the AVR system. The dandelion optimizer (DO), a successful optimization algorithm, is used to optimize the parameters of the proposed SFOPID control strategy. The optimization process for the DO-SFOPID control strategy includes a variety of objective functions, including error-based metrics such as integral of absolute error, integral of squared error, integral of time absolute error, and integral of time squared error, in addition to the user-defined Zwee Lee Gaing’s metric. The effectiveness of the DO-SFOPID control technique on the AVR system has been rigorously investigated through a series of tests and analyses, including aspects such as time domain, robustness, frequency domain, and evaluation of nonlinearity effects. The simulation results are compared between the proposed DO-SFOPID control technique and the fractional-order PID (FOPID) and sigmoid-based PID (SPID) control techniques, both of which have been tuned using different metaheuristic algorithms that have gained significant recognition in recent years. As a result of these comparative analyses, the superiority of the DO-SFOPID control technique is confirmed as it shows an improved performance with respect to the other control techniques. Furthermore, the performance of the proposed DO-SFOPID control technique is validated within an experimental setup for the AVR system. The simulation results show that the proposed DO-SFOPID control technique is highly successful in terms of stability and robustness. In summary, this study provides comprehensive evidence supporting the effectiveness and superiority of the DO-SFOPID control technique on the AVR system through both simulation and experimental results.


  • DC Motorun Hız Kontrolü İçin Meta-Sezgisel Algoritma Tabanlı PID Denetleyici Tasarımı

    by Ali Kıvanç Şahi̇n, Ömür Akyazi, Erdinc Sahin, Oğuzhan Çakir

    Bu makalede DC motorun hız kontrolü için balina optimizasyon (WOA) ve güve-alevi optimizasyon (MFO) algoritmaları kullanılarak en uygun kp, ki, kd PID denetleyici parametreleri belirlenmiştir. PID parametre değerleri belirlenirken her iki algoritma için de hata tabanlı bir amaç fonksiyonu olan hatanın mutlak değerinin zaman ağırlıklı integrali (ITAE) seçilmiştir. İki farklı yaklaşımla tasarlanan PID denetleyicilerin geçici yanıt analizi, frekans analizi, performans indislerinin analizi ve yük bozucu cevabı analizi Matlab programı aracılığıyla gerçekleştirilmiş ve performans karşılaştırılmaları yapılmıştır. Bulunan sonuçlara göre WOA-PID tabanlı denetleyicinin MFO-PID tabanlı denetleyiciye göre daha iyi sonuç verdiği gözlemlenmiştir. Ayrıca WOA-PID denetleyicisinin atom arama (ASO), gri kurt (GWO), yabani ot (IWO), stokastik fraktal arama (SFS) algoritmaları kullanılarak ayarlanmış PID denetleyicilerine göre geçici yanıt karakteristiğini iyileştirdiği, dayanıklılığını arttırdığı ve sistemde yük torkundan kaynaklanan bir değişiklik meydana geldiğinde bu bozulmayı daha kısa sürede toparlamayı başardığı görülmüştür.