Guillermo Orozco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guillermo Orozco has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
R. Nocentini
Max Planck Inst Plasma Phys, Boltzmannstr 2, D-85748 Garching, Germany
4 shared publications- Andrew Hurlbatt
Max Planck Institut f. Plasmaphysik (IPP), Boltzmannstr. 2, 85748 Garching, Germany
3 shared publications B. Heinemann
Max Planck Inst Plasma Phys, Boltzmannstr 2, D-85748 Garching, Germany
3 shared publications- Bernd Heinemann
Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching, Germany
3 shared publications - Christian Wimmer
Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching, Germany
3 shared publications M. Froeschle
3 shared publications
Latest Publications
- Open Access
- 19 June 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 205
A calorimetric evaluation method for beam targets with IR imaging: Implementation for the negative ion source BATMAN Upgrade
- 19 June 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 205
Open AccessA calorimetric evaluation method for beam targets with IR imaging: Implementation for the negative ion source BATMAN Upgrade
- Open Access
- 26 January 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 189
3D magnetic field measurements and improvements at the negative ion source BATMAN Upgrade
- 26 January 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 189
Open Access3D magnetic field measurements and improvements at the negative ion source BATMAN Upgrade
- Open Access
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012053
ITER-HNB plasma and extraction grids in BUG: Characterization of magnetic deflection correction
The BATMAN Upgrade test facility aims to extract H-/D- at high current densities. The inevitably co-extracted electrons are deflected out of the beamlet by permanent magnets before acceleration. These magnets induce a row-wise zig-zag deflection of the beamlets. In the new MITICA-like extraction system, this deflection is compensated by additional deflection correction magnets. IBSimu modeling studies indicate that the deflection correction system not only acts on the horizontal beamlet deflection, but also causes aberrations to the vertical angular distribution. Dependencies of the beamlet position and size are studied in several parameter scans with the available diagnostic tools (CFC tile calorimetry, Beam Emission Spectroscopy). The horizontal beamlet deflection is robustly compensated within the systematic uncertainty of the experiment. The triangular beamlet shape predicted on basis of the magnetic field structure is visible in the CFC calorimetry.
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012053
Open AccessITER-HNB plasma and extraction grids in BUG: Characterization of magnetic deflection correction
The BATMAN Upgrade test facility aims to extract H-/D- at high current densities. The inevitably co-extracted electrons are deflected out of the beamlet by permanent magnets before acceleration. These magnets induce a row-wise zig-zag deflection of the beamlets. In the new MITICA-like extraction system, this deflection is compensated by additional deflection correction magnets. IBSimu modeling studies indicate that the deflection correction system not only acts on the horizontal beamlet deflection, but also causes aberrations to the vertical angular distribution. Dependencies of the beamlet position and size are studied in several parameter scans with the available diagnostic tools (CFC tile calorimetry, Beam Emission Spectroscopy). The horizontal beamlet deflection is robustly compensated within the systematic uncertainty of the experiment. The triangular beamlet shape predicted on basis of the magnetic field structure is visible in the CFC calorimetry.
- Open Access
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012051
Overview of recent and upcoming activities at the BATMAN Upgrade test facility
The BATMAN Upgrade (BUG) test facility at IPP is contributing to the development of RF-driven H- sources towards the ITER neutral beam injection and beyond. BUG is equipped with an 1/8 size of the ITER NBI ion source and thus is highly flexible for setup changes or diagnostic access. The present strategy for BUG is aligned along two paths: (i) BUG is continuing to be upgraded upgrading for long pulse operation (up to 1 hour, both in H and D) to identify measures for the stabilization of long pulses. For pulses > 100 s a cooling of the plasma grid (first grid of the extraction system) is required in order to avoid the dominance of thermal Cs desorption. A Cs evaporation concept with evaporation close to the extraction system is being tested, showing a stabilization of co-extracted electrons in 100 s H pulses, (ii) BUG is used for investigations of whole beam and beamlet optics for which the beam diagnostics have been massively upgraded. The beam diagnostics have been used to characterize a newly installed MITICA-like extraction system including asymmetric deflection compensation magnets.
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2244 (1) , 012051
Open AccessOverview of recent and upcoming activities at the BATMAN Upgrade test facility
The BATMAN Upgrade (BUG) test facility at IPP is contributing to the development of RF-driven H- sources towards the ITER neutral beam injection and beyond. BUG is equipped with an 1/8 size of the ITER NBI ion source and thus is highly flexible for setup changes or diagnostic access. The present strategy for BUG is aligned along two paths: (i) BUG is continuing to be upgraded upgrading for long pulse operation (up to 1 hour, both in H and D) to identify measures for the stabilization of long pulses. For pulses > 100 s a cooling of the plasma grid (first grid of the extraction system) is required in order to avoid the dominance of thermal Cs desorption. A Cs evaporation concept with evaporation close to the extraction system is being tested, showing a stabilization of co-extracted electrons in 100 s H pulses, (ii) BUG is used for investigations of whole beam and beamlet optics for which the beam diagnostics have been massively upgraded. The beam diagnostics have been used to characterize a newly installed MITICA-like extraction system including asymmetric deflection compensation magnets.
- Open Access
- 1 January 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2373 (1) , 030004
Impact of operational parameters on single beamlet deflection in a negative ion source for NBI applications
For current and future large scale tokamaks, neutral beams for heating and current drive are generated from the neutralisation of large negative ion beams with energies up to 1 MeV and current of up to 40 A. To improve efficiency and prevent high heat loads on beamline components, permanent magnets are used to deflect co-extracted electrons out of the beam at a low energy. This field also affects the negative ions as they are accelerated, causing beamlets to exit the grid system with a residual offset and deflection angle. This adversely affects the overall divergence of the beam, and compensation is foreseen in future devices. Measurements of the residual deflection of a single beamlet have been carried out at the BATMAN Upgrade test facility by calculating relative beamlet angles from beam emission spectroscopy (BES) spectra, and through the use of one-dimensional carbon fibre composite (1D-CFC) tile calorimetry to find beamlet positions. It is described how these measurements can be made, and that they are limited to relative measurements only, for a single beamlet and for a single line of sight. The amount of beamlet deflection is shown to change significantly, by up to 0.6°(10 mrad), depending on the operational parameters used. As is to be expected the beamlet deflection angle is observed to be affected by changes to the voltages of the acceleration system. However, the beamlet deflection angle is also observed to change with RF power and other source parameters, which, to a first approximation, should only affect beamlet divergence, and not the deflection. These changes to beamlet deflection through parameters other than the grid voltages used may have consequences for systems planning to use suppression systems for the zig-zag deflection. The effectiveness of the suppression system may be reduced due to changes in the source parameters, which could lead to beam losses and high heat loads on downstream components.
- 1 January 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2373 (1) , 030004
Open AccessImpact of operational parameters on single beamlet deflection in a negative ion source for NBI applications
For current and future large scale tokamaks, neutral beams for heating and current drive are generated from the neutralisation of large negative ion beams with energies up to 1 MeV and current of up to 40 A. To improve efficiency and prevent high heat loads on beamline components, permanent magnets are used to deflect co-extracted electrons out of the beam at a low energy. This field also affects the negative ions as they are accelerated, causing beamlets to exit the grid system with a residual offset and deflection angle. This adversely affects the overall divergence of the beam, and compensation is foreseen in future devices. Measurements of the residual deflection of a single beamlet have been carried out at the BATMAN Upgrade test facility by calculating relative beamlet angles from beam emission spectroscopy (BES) spectra, and through the use of one-dimensional carbon fibre composite (1D-CFC) tile calorimetry to find beamlet positions. It is described how these measurements can be made, and that they are limited to relative measurements only, for a single beamlet and for a single line of sight. The amount of beamlet deflection is shown to change significantly, by up to 0.6°(10 mrad), depending on the operational parameters used. As is to be expected the beamlet deflection angle is observed to be affected by changes to the voltages of the acceleration system. However, the beamlet deflection angle is also observed to change with RF power and other source parameters, which, to a first approximation, should only affect beamlet divergence, and not the deflection. These changes to beamlet deflection through parameters other than the grid voltages used may have consequences for systems planning to use suppression systems for the zig-zag deflection. The effectiveness of the suppression system may be reduced due to changes in the source parameters, which could lead to beam losses and high heat loads on downstream components.
- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 2105-2109
Reviewed design of the high heat flux panels for the AUG and W7-X neutral beam calorimeter
- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 2105-2109
Reviewed design of the high heat flux panels for the AUG and W7-X neutral beam calorimeter
- 11 January 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 518-521
Modeling neutral beam transport in fusion experiments: Studying the effects of reionisation and deflection
- 11 January 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 518-521
Modeling neutral beam transport in fusion experiments: Studying the effects of reionisation and deflection
- 17 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 44 (9) , 1553-1558
Optimization of Large Titanium Sublimation Pumps for the Neutral Beam Injection System on AUG and W7-X
The neutral beam injection (NBI) system for the magnetic confinement experiments ASDEX Upgrade (AUG) and Wendelstein 7-X (W7-X) require a vacuum system with a high pumping speed of up to 3000 m 3 /s for H 2 and a large capacity with a gas feed of up to 30 Pa m 3 /s and 10 s. It must ensure a maximum vacuum level of 10 -2 Pa in any section of the neutral beam line in order to avoid reionization losses. The large titanium sublimation pumps (TSPs) of the NBI system at AUG have been proved suitable for operation within the permanent stray magnetic field of W7-X (up to 30 mT) if they are operated with 200-500-Hz sine ac instead of dc for the ohmic heating of the 4-m long hanging pairs of titanium sublimators. During each heating cycle, the pair of sublimators experiences a reversible thermal expansion of around 50 mm and, in addition, the tantalum core of the sublimators is subject to material creep, leading to residual lengthening. When this lengthening reaches 70 mm after 80-100 thermal cycles (3.5-4.5 h operation time), the wires contact the bottom of the NBI vessel causing a short circuit. In order to extend the availability and operation time of the TSP, a modification of the sublimator with a tantalum-tungsten core with 2.5% W is tested, for which less creep is expected. The first results confirm a reduction in the creep rate by a factor of ~20. This allows sublimation of the whole Ti inventory without intermediate maintenance of the TSP. Furthermore, possible short-circuit mitigation strategies are discussed.
- 17 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 44 (9) , 1553-1558
Optimization of Large Titanium Sublimation Pumps for the Neutral Beam Injection System on AUG and W7-X
The neutral beam injection (NBI) system for the magnetic confinement experiments ASDEX Upgrade (AUG) and Wendelstein 7-X (W7-X) require a vacuum system with a high pumping speed of up to 3000 m 3 /s for H 2 and a large capacity with a gas feed of up to 30 Pa m 3 /s and 10 s. It must ensure a maximum vacuum level of 10 -2 Pa in any section of the neutral beam line in order to avoid reionization losses. The large titanium sublimation pumps (TSPs) of the NBI system at AUG have been proved suitable for operation within the permanent stray magnetic field of W7-X (up to 30 mT) if they are operated with 200-500-Hz sine ac instead of dc for the ohmic heating of the 4-m long hanging pairs of titanium sublimators. During each heating cycle, the pair of sublimators experiences a reversible thermal expansion of around 50 mm and, in addition, the tantalum core of the sublimators is subject to material creep, leading to residual lengthening. When this lengthening reaches 70 mm after 80-100 thermal cycles (3.5-4.5 h operation time), the wires contact the bottom of the NBI vessel causing a short circuit. In order to extend the availability and operation time of the TSP, a modification of the sublimator with a tantalum-tungsten core with 2.5% W is tested, for which less creep is expected. The first results confirm a reduction in the creep rate by a factor of ~20. This allows sublimation of the whole Ti inventory without intermediate maintenance of the TSP. Furthermore, possible short-circuit mitigation strategies are discussed.
- 1 December 2014
- Published by Elsevier in Fusion Engineering and Design
- Vol. 89 (12) , 3070-3077
AC operation of large titanium sublimation pumps in a magnetic field: Results of the test stand for the W7-X neutral beam injectors
- 1 December 2014
- Published by Elsevier in Fusion Engineering and Design
- Vol. 89 (12) , 3070-3077
AC operation of large titanium sublimation pumps in a magnetic field: Results of the test stand for the W7-X neutral beam injectors