Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenjie Liu has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Physically Constrained Inverse-Gaussian Deconvolution of Diffusion-Broadened Drift-Tube Ion Mobility Spectra

    by Haoran Huang, Zhicheng Li, Lu Chen, Jianna Yu, Wenjie Liu

    Peak overlap limits chemical assignment in drift-tube ion mobility spectrometry (DT-IMS). Diffusion broadening is commonly modeled with symmetric Gaussian kernels, although a fixed detector records ion first-passage times. We developed an inverse-Gaussian-Nernst-Townsend-Einstein (IG-NTE) deconvolution framework in which the point-spread function (PSF) follows an inverse-Gaussian distribution and its temporal width is constrained by instrument settings through the NTE relation. The resulting drift-time-dependent measurement operator was inverted by nonnegative Richardson-Lucy iteration without peak-width calibration or specification of component number. In simulations, relative to a Gaussian kernel, IG-NTE deconvolution reduced the average full-residual root-mean-square value by 11.4%, the right-tail residual by 18.1%, and the mean absolute peak-area deviation from 5.10% to 1.19%. Applied to a 63Ni DT-IMS instrument, the method separated ethyl 2-methylpentanoate and 1,8-cineole responses 0.040 ms apart while retaining 2,6-di-tert-butylpyridine (DTBP) as a single-component control. It also recovered paired alkyl-pyrazine mobility features consistent with protonation site- and hydration-dependent collision cross sections. In the negative mode, dichloromethane-derived chloride responses assigned to 35Cl− and 37Cl− exhibited a 3.08:1 area ratio and were supported by GC-TOF-MS. These results show that detector-domain transport modeling can improve the effective reconstructed resolution of diffusion-broadened DT-IMS spectra without hardware modification, provided that controls and forward residual analysis are used to assess reconstruction artifacts.

  • Efficient Separation of Disaccharide Isomers Using Ion Mobility Spectrometry by Metal Cation and Anion Assisted Strategy

    by Wen Liu, Shi Chen, Xingjuan Du, Zhengwen Zhang, Jianna Yu, Guoxing Jing, Wenshan Li, Wenjie Liu

    The rapid separation and identification of disaccharide isomers pose a significant analytical challenge in fields such as food science and glycobiology. This study developed a fast, simple, and low-cost analytical method based on electrospray ionization ion mobility spectrometry (ESI-IMS) combined with an ion adduction strategy for the efficient separation of eight common disaccharide isomers. The principle involves introducing specific metal cations or anions into the disaccharide solution to form stable adducts, thereby significantly altering their drift behavior during IMS analysis. Systematic screening of seven cations and nine anions and mass spectrometry result revealed that in positive ion mode, Cu+ forms structurally rigid dimeric adducts [Cu + 2M]+ with disaccharides, effectively amplifying subtle stereostructural differences into significant distinctions in collision cross section (CCS) and increasing the proportion of fully separated disaccharide pairs to 71.4%. In negative ion mode, I− forms predominantly single [I + M]− adducts, substantially simplifying the complex original spectra and achieving a full separation rate of 60.7%. Theoretical calculations indicated stable electronic structures within the complex systems and the differences in both the strength and interaction characteristics between the two types of adducts. This method requires no complex pretreatment or expensive advanced instrumentation, and is readily implementable on conventional drift-tube IMS platforms. It thus offers a robust, cost-effective, and high-throughput solution for disaccharide isomer analysis, with potential applications in food science, biomedicine, and materials characterization.

  • Fourier Deconvolution Multiplexing Boosts Ion Throughput in Pinhole-Interfaced GC-IMS/MS for Synchronous Peak Identification

    by Xiuqing Zheng, Jianna Yu, Mengting Huang, Jiaxu Liu, Jiaxing Li, Peixuan Huang, Lu Cheng, Binwang Yang, Haoran Huang, Zhuyue Peng, et al.

    Gas chromatography-ion mobility spectrometry has been recognized as a rapid, sensitive, portable approach at low cost in food safety analysis, environmental monitoring, and security screening. However, the peak identification remains a major challenge due to the lack of sufficiently comprehensive reference databases. This study successfully developed and validated an integrated gas chromatography-ion mobility spectrometry/mass spectrometry (GC-IMS/MS) platform incorporating Fourier deconvolution (FD) technology and a pinhole IMS-MS interface, aiming to resolve the limitations of low ion utilization efficiency and detector sensitivity imbalance in conventional GC-IMS/MS systems. The implementation of FD multiplexing increased the ion gate duty cycle from 0.995) across concentration ranges spanning 3 orders of magnitude and achieving detection limits at the ng/mL level. Three complex extracts including tobacco, Da Hong Pao tea, and apricot flavoring were investigated to evaluate the performance of the developed system, and it was demonstrated that the developed system exhibited precise compound identification and high-throughput nontargeted screening capabilities.


  • Accurate detection of trace level black powder with miniaturized Fourier deconvolution ion mobility spectrometer

    by Binwang Yang, Xiuqing Zheng, Feiyu Lu, Jianna Yu, Guoxing Jing, Wen Liu, Wenshan Li, Zhaohong Wang, Wenjie Liu


  • Quantitative Determination of Volatile N-Nitrosamines in Meat Products Using Gas Chromatography Coupled to an Ion Mobility Spectrometer with an Ammonia Dopant

    by Cheng Wang, Lian Duan, Binwang Yang, Zhixiong Ye, Jianna Yu, Jiaxu Liu, Xiuqin Zheng, Qi Yang, Guoxin Jing, Wen Liu, et al.

    Herein, we develop a novel method using gas chromatography-ion mobility spectrometry (IMS) with an ammonia dopant for the determination of volatile N-nitrosamines in meat products. The IMS system was implemented with Fourier deconvolution multiplexing to simultaneously improve the resolving power and sensitivity. The ammonia dopant mitigated the formation of N-nitrosamine dimer ions, suppressing the ionization of interferents and shifting the reactant peak from hydrated protons to hydrated ammonium ions. The ammonium adduct product ions of N-nitrosamines were confirmed using time-of-flight mass spectrometry. The instrument limits of detection and quantitation for nitrosamines were 0.78-1.79 and 2.60-5.82 ng/mL, respectively, with recoveries between 71.39% and 110.59% using a simple water distillation method. The developed method showed satisfactory performance when applied to the detection of nitrosamines in various meat products.


  • High Resolving Power Electrospray Ionization Ion Mobility Spectrometer Based on Fourier Deconvolution Multiplexing

    by Binwang Yang, Zhixiong Ye, Feiyu Lu, Jianna Yu, Jiaxu Liu, Xiuqing Zheng, Cheng Wang, Lian Duan, Zhijian Yang, Guoxing Jing, et al.

    The resolving power of the drift tube ion mobility spectrometry (IMS) is mainly dependent on the drift length, the drift voltage, the pulse width of an ion gate, and the pressure inside the drift tube. Electrospray ionization (ESI)-IMS is a highly sensitive and reliable technique for the detection and analysis of nonvolatile compounds, and high resolving power is necessary to separate structurally similar compounds. To improve the analytical performance of atmospheric pressure ESI-IMS, the Fourier deconvolution (FD) multiplexing technique is investigated as an effective and convenient means to improve the resolving power as well as the signal-to-noise ratio. By reducing the equivalent ion gate opening width to 5 μs using a typical Tyndall-Powell ion shutter, a high resolving power RP up to 170 can be achieved with a drift length of 12 cm and a drift voltage of 10 kV. Rhodamine 6G (R6G), sodium dodecyl sulfate (SDS), methacycline, oxytetracycline, and ractopamine were evaluated using the FD-ESI-IMS, and mixtures with similar ion mobility can be well separated without prolonging the drift length.


  • Implementing of Fourier Deconvolution Multiplexing to Fast Polarity Switching Miniaturized Ion Mobility Spectrometer

    by Binwang Yang, Zhixiong Ye, Hehan Li, Juliet Nwadiuso Okonkwo, Jianna Yu, Guoxing Jing, Wen Liu, Wenshan Li, Wenjie Liu

    Ion mobility spectrometry (IMS) is a reliable and sensitive technique for the detection and analysis of compounds at the trace level. Depending on the chemical composition of the sample, compounds may be positively or negatively charged to form different polarity ions and detected in positive or negative polarity of the electric field. In order to detect multiple threats simultaneously with miniaturized devices, using a single detection unit to achieve high resolving power and high sensitivity is important. In this work, a miniaturized drift tube with fast polarity switching capabilities integrated with Fourier deconvolution multiplexing techniques is proposed for the first time as a means to improve the performance of ion mobility spectrometry. The sensitivity and resolving power are improved compared to traditional polarity switching signal averaging data acquisition methods. The displayed device had a high resolving power up to 52 at a drift length of 41 mm and a drift tube voltage of 2 kV. Trinitrotoluene (TNT), methamphetamine (MA), benzene, toluene, methyl tert-butyl ether (MTBE), acetic acid, and methylene chloride were evaluated using the proposed fast polarity switching multiplexing spectrometer and exhibited satisfied performance.


  • Open Access

    Miniaturized Photo-Ionization Fourier Deconvolution Ion Mobility Spectrometer for the Detection of Volatile Organic Compounds

    by Binwang Yang, Jianna Yu, Wen Liu, Guoxing Jing, Wenshan Li, Wenjie Liu

    Because of its simplicity, reliability, and sensitivity, the drift tube ion mobility spectrometer (IMS) has been recognized as the equipment of choice for the on-site monitoring and identification of volatile organic compounds (VOCs). However, the performance of handheld IMS is often limited by the size, weight, and drift voltage, which heavily determine the sensitivity and resolving power that is crucial for the detection and identification of VOCs. In this work, we present a low-cost, miniaturized drift tube ion mobility spectrometer incorporated with a miniaturized UV ionization lamp and a relatively low drift voltage. The sensitivity and resolving power are boosted with the implementation of Fourier deconvolution multiplexing compared to the conventional signal averaging data acquisition method. The drift tube provides a high resolving power of up to 52 at a drift length of 41 mm, 10 mm ID dimensions, and a drift voltage of 1.57 kV. Acetone, benzene, dimethyl methyl phosphonate, methyl salicylate, and acetic acid were evaluated in the developed spectrometer and showed satisfactory performance.