Binwang Yang
Research Subjects
Binwang Yang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Jianna Yu
College of Chemical Engineering
5 shared publications- Wenjie Liu
Xiangtan University
5 shared publications Wen Liu
College of Chemical Engineering, Xiangtan University, Xiangtan, 411105, China
4 shared publicationsWenshan Li
College of Chemical Engineering, Xiangtan University, Xiangtan, 411105, China
4 shared publicationsGuoxing Jing
College of Chemical Engineering, Xiangtan University, Xiangtan, 411105, China
3 shared publicationsJiaxu Liu
College of Chemical Engineering
3 shared publications
Latest Publications
- 20 March 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (12) , 9334-9344
Fourier Deconvolution Multiplexing Boosts Ion Throughput in Pinhole-Interfaced GC-IMS/MS for Synchronous Peak Identification
Gas chromatography-ion mobility spectrometry has been recognized as a rapid, sensitive, portable approach at low cost in food safety analysis, environmental monitoring, and security screening. However, the peak identification remains a major challenge due to the lack of sufficiently comprehensive reference databases. This study successfully developed and validated an integrated gas chromatography-ion mobility spectrometry/mass spectrometry (GC-IMS/MS) platform incorporating Fourier deconvolution (FD) technology and a pinhole IMS-MS interface, aiming to resolve the limitations of low ion utilization efficiency and detector sensitivity imbalance in conventional GC-IMS/MS systems. The implementation of FD multiplexing increased the ion gate duty cycle from 0.995) across concentration ranges spanning 3 orders of magnitude and achieving detection limits at the ng/mL level. Three complex extracts including tobacco, Da Hong Pao tea, and apricot flavoring were investigated to evaluate the performance of the developed system, and it was demonstrated that the developed system exhibited precise compound identification and high-throughput nontargeted screening capabilities.
- 20 March 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (12) , 9334-9344
Fourier Deconvolution Multiplexing Boosts Ion Throughput in Pinhole-Interfaced GC-IMS/MS for Synchronous Peak Identification
Gas chromatography-ion mobility spectrometry has been recognized as a rapid, sensitive, portable approach at low cost in food safety analysis, environmental monitoring, and security screening. However, the peak identification remains a major challenge due to the lack of sufficiently comprehensive reference databases. This study successfully developed and validated an integrated gas chromatography-ion mobility spectrometry/mass spectrometry (GC-IMS/MS) platform incorporating Fourier deconvolution (FD) technology and a pinhole IMS-MS interface, aiming to resolve the limitations of low ion utilization efficiency and detector sensitivity imbalance in conventional GC-IMS/MS systems. The implementation of FD multiplexing increased the ion gate duty cycle from 0.995) across concentration ranges spanning 3 orders of magnitude and achieving detection limits at the ng/mL level. Three complex extracts including tobacco, Da Hong Pao tea, and apricot flavoring were investigated to evaluate the performance of the developed system, and it was demonstrated that the developed system exhibited precise compound identification and high-throughput nontargeted screening capabilities.
- 17 October 2024
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 72 (43) , 24101-24108
Quantitative Determination of Volatile N-Nitrosamines in Meat Products Using Gas Chromatography Coupled to an Ion Mobility Spectrometer with an Ammonia Dopant
Herein, we develop a novel method using gas chromatography-ion mobility spectrometry (IMS) with an ammonia dopant for the determination of volatile N-nitrosamines in meat products. The IMS system was implemented with Fourier deconvolution multiplexing to simultaneously improve the resolving power and sensitivity. The ammonia dopant mitigated the formation of N-nitrosamine dimer ions, suppressing the ionization of interferents and shifting the reactant peak from hydrated protons to hydrated ammonium ions. The ammonium adduct product ions of N-nitrosamines were confirmed using time-of-flight mass spectrometry. The instrument limits of detection and quantitation for nitrosamines were 0.78-1.79 and 2.60-5.82 ng/mL, respectively, with recoveries between 71.39% and 110.59% using a simple water distillation method. The developed method showed satisfactory performance when applied to the detection of nitrosamines in various meat products.
- 17 October 2024
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 72 (43) , 24101-24108
Quantitative Determination of Volatile N-Nitrosamines in Meat Products Using Gas Chromatography Coupled to an Ion Mobility Spectrometer with an Ammonia Dopant
Herein, we develop a novel method using gas chromatography-ion mobility spectrometry (IMS) with an ammonia dopant for the determination of volatile N-nitrosamines in meat products. The IMS system was implemented with Fourier deconvolution multiplexing to simultaneously improve the resolving power and sensitivity. The ammonia dopant mitigated the formation of N-nitrosamine dimer ions, suppressing the ionization of interferents and shifting the reactant peak from hydrated protons to hydrated ammonium ions. The ammonium adduct product ions of N-nitrosamines were confirmed using time-of-flight mass spectrometry. The instrument limits of detection and quantitation for nitrosamines were 0.78-1.79 and 2.60-5.82 ng/mL, respectively, with recoveries between 71.39% and 110.59% using a simple water distillation method. The developed method showed satisfactory performance when applied to the detection of nitrosamines in various meat products.
- 16 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (43) , 17423-17431
High Resolving Power Electrospray Ionization Ion Mobility Spectrometer Based on Fourier Deconvolution Multiplexing
The resolving power of the drift tube ion mobility spectrometry (IMS) is mainly dependent on the drift length, the drift voltage, the pulse width of an ion gate, and the pressure inside the drift tube. Electrospray ionization (ESI)-IMS is a highly sensitive and reliable technique for the detection and analysis of nonvolatile compounds, and high resolving power is necessary to separate structurally similar compounds. To improve the analytical performance of atmospheric pressure ESI-IMS, the Fourier deconvolution (FD) multiplexing technique is investigated as an effective and convenient means to improve the resolving power as well as the signal-to-noise ratio. By reducing the equivalent ion gate opening width to 5 μs using a typical Tyndall-Powell ion shutter, a high resolving power RP up to 170 can be achieved with a drift length of 12 cm and a drift voltage of 10 kV. Rhodamine 6G (R6G), sodium dodecyl sulfate (SDS), methacycline, oxytetracycline, and ractopamine were evaluated using the FD-ESI-IMS, and mixtures with similar ion mobility can be well separated without prolonging the drift length.
- 16 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (43) , 17423-17431
High Resolving Power Electrospray Ionization Ion Mobility Spectrometer Based on Fourier Deconvolution Multiplexing
The resolving power of the drift tube ion mobility spectrometry (IMS) is mainly dependent on the drift length, the drift voltage, the pulse width of an ion gate, and the pressure inside the drift tube. Electrospray ionization (ESI)-IMS is a highly sensitive and reliable technique for the detection and analysis of nonvolatile compounds, and high resolving power is necessary to separate structurally similar compounds. To improve the analytical performance of atmospheric pressure ESI-IMS, the Fourier deconvolution (FD) multiplexing technique is investigated as an effective and convenient means to improve the resolving power as well as the signal-to-noise ratio. By reducing the equivalent ion gate opening width to 5 μs using a typical Tyndall-Powell ion shutter, a high resolving power RP up to 170 can be achieved with a drift length of 12 cm and a drift voltage of 10 kV. Rhodamine 6G (R6G), sodium dodecyl sulfate (SDS), methacycline, oxytetracycline, and ractopamine were evaluated using the FD-ESI-IMS, and mixtures with similar ion mobility can be well separated without prolonging the drift length.
- 30 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (6) , 2360-2368
Implementing of Fourier Deconvolution Multiplexing to Fast Polarity Switching Miniaturized Ion Mobility Spectrometer
Ion mobility spectrometry (IMS) is a reliable and sensitive technique for the detection and analysis of compounds at the trace level. Depending on the chemical composition of the sample, compounds may be positively or negatively charged to form different polarity ions and detected in positive or negative polarity of the electric field. In order to detect multiple threats simultaneously with miniaturized devices, using a single detection unit to achieve high resolving power and high sensitivity is important. In this work, a miniaturized drift tube with fast polarity switching capabilities integrated with Fourier deconvolution multiplexing techniques is proposed for the first time as a means to improve the performance of ion mobility spectrometry. The sensitivity and resolving power are improved compared to traditional polarity switching signal averaging data acquisition methods. The displayed device had a high resolving power up to 52 at a drift length of 41 mm and a drift tube voltage of 2 kV. Trinitrotoluene (TNT), methamphetamine (MA), benzene, toluene, methyl tert-butyl ether (MTBE), acetic acid, and methylene chloride were evaluated using the proposed fast polarity switching multiplexing spectrometer and exhibited satisfied performance.
- 30 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (6) , 2360-2368
Implementing of Fourier Deconvolution Multiplexing to Fast Polarity Switching Miniaturized Ion Mobility Spectrometer
Ion mobility spectrometry (IMS) is a reliable and sensitive technique for the detection and analysis of compounds at the trace level. Depending on the chemical composition of the sample, compounds may be positively or negatively charged to form different polarity ions and detected in positive or negative polarity of the electric field. In order to detect multiple threats simultaneously with miniaturized devices, using a single detection unit to achieve high resolving power and high sensitivity is important. In this work, a miniaturized drift tube with fast polarity switching capabilities integrated with Fourier deconvolution multiplexing techniques is proposed for the first time as a means to improve the performance of ion mobility spectrometry. The sensitivity and resolving power are improved compared to traditional polarity switching signal averaging data acquisition methods. The displayed device had a high resolving power up to 52 at a drift length of 41 mm and a drift tube voltage of 2 kV. Trinitrotoluene (TNT), methamphetamine (MA), benzene, toluene, methyl tert-butyl ether (MTBE), acetic acid, and methylene chloride were evaluated using the proposed fast polarity switching multiplexing spectrometer and exhibited satisfied performance.
- 14 December 2023
- Published by Wiley in Journal of Separation Science
- Vol. 47 (1) , e2300597
High‐performance liquid chromatography analysis of alkaloids in various parts of lotus extracts with ion mobility spectrometry and mass spectrometry dual detection
Using high‐performance liquid chromatography coupled with electrospray ionization‐ion mobility spectrometry and mass spectrometry, we proposed a dual‐detection method for the identification and profiling of alkaloids in various lotus parts including leaf, plumule, stem, seed epicarp, and receptacle. The eluent from high‐performance liquid chromatography was split and conducted to electrospray ionization‐ion mobility spectrometry and time‐of‐flight mass spectrometry separately to facilitate the compound identification. In total, 23 kinds of alkaloids were identified based on m/z, drift time, and retention time, including alkaloid isomers such as lirinidine, N‐nornuciferine, and O‐nornuciferine with identical m/z that are difficult to differentiate using mass spectrometry alone. Using this method, we investigated the changing dynamics of alkaloid accumulation in lotus leaves and lotus stems at different harvesting periods. The total alkaloid content showed an increasing trend with the growth and development of leave and stem. Overall, the developed dual detection method has the advantages of high peak capacity and high sensitivity compared with the conventional detection method and facilitates the identification of detected compounds.
- 14 December 2023
- Published by Wiley in Journal of Separation Science
- Vol. 47 (1) , e2300597
High‐performance liquid chromatography analysis of alkaloids in various parts of lotus extracts with ion mobility spectrometry and mass spectrometry dual detection
Using high‐performance liquid chromatography coupled with electrospray ionization‐ion mobility spectrometry and mass spectrometry, we proposed a dual‐detection method for the identification and profiling of alkaloids in various lotus parts including leaf, plumule, stem, seed epicarp, and receptacle. The eluent from high‐performance liquid chromatography was split and conducted to electrospray ionization‐ion mobility spectrometry and time‐of‐flight mass spectrometry separately to facilitate the compound identification. In total, 23 kinds of alkaloids were identified based on m/z, drift time, and retention time, including alkaloid isomers such as lirinidine, N‐nornuciferine, and O‐nornuciferine with identical m/z that are difficult to differentiate using mass spectrometry alone. Using this method, we investigated the changing dynamics of alkaloid accumulation in lotus leaves and lotus stems at different harvesting periods. The total alkaloid content showed an increasing trend with the growth and development of leave and stem. Overall, the developed dual detection method has the advantages of high peak capacity and high sensitivity compared with the conventional detection method and facilitates the identification of detected compounds.