James Jin Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James Jin Kang has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Henry Larkin
Deakin University, School of Information Technology, Deakin University, Burwood, Victoria, Australia
6 shared publications- Magdalena Wajrak
Edith Cowan University
4 shared publications - Wencheng Yang
School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba, QLD, Australia
4 shared publications - Kiran Fahd
Department of Business and Construction, Melbourne Polytechnic, Preston, VIC 3072, Australia
3 shared publications - Paul Haskell-Dowland
Edith Cowan University
3 shared publications Sasan Adibi
School of Information Technology, Deakin University Geelong, VIC Australia
3 shared publications
Latest Publications
- Open Access
- 29 August 2026
- Published by Elsevier in SSRN Electronic Journal
The Metric Blind Spot in Deep Learning-Based Brain MRI Reconstruction: A Systematic Review
Objective: Deep learning accelerates brain MRI four- to tenfold, but learned models can erase a lesion or invent tissue, and pixel-averaged scores such as PSNR and SSIM miss both. We review whether evaluation practice could detect this blind spot. Methods: Following PRISMA 2020 we searched seven databases without date limit, included 263 studies (1995-2026), appraised them with QUADAS-2 and matched instruments, and synthesised narratively. Categories came from titles, abstracts and controlled vocabulary; every prevalence figure is a floor. Duplicate screening achieved substantial agreement (Fleiss' kappa = 0.877); appraisal agreement was substantial (0.788; 0.390 where observable); extraction is unaudited. Results: Only 18 of 263 studies (6.8%) record a fidelity metric and a reader assessment on the same data, leaving the field's central proxy unmeasured. Reader studies mostly measure reader-versus-reader agreement, which is weak: fastMRI 2020 concordance was 0.457 and 0.386 (Kendall's W), improving only where SSIM had diverged. Erasing a 100 mm3 lacunar infarct moves global PSNR about 0.03 dB under the stated error model. The corpus grew fivefold; reader assessment fell from 32% to 18%, recovering to 21%. Among the four largest families the most hallucination-associated (generative, 39%) is among the least reader-evaluated (11.3%); self-supervised is higher still (47%) with no readers. One study in twenty both releases code and runs readers; none evaluated a model observer; no named dataset covers acute stroke or haemorrhage. Conclusions: On these floors, evaluation practice cannot certify diagnostic safety. We derive five requirements safety-oriented evaluation must meet.
- 29 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe Metric Blind Spot in Deep Learning-Based Brain MRI Reconstruction: A Systematic Review
Objective: Deep learning accelerates brain MRI four- to tenfold, but learned models can erase a lesion or invent tissue, and pixel-averaged scores such as PSNR and SSIM miss both. We review whether evaluation practice could detect this blind spot. Methods: Following PRISMA 2020 we searched seven databases without date limit, included 263 studies (1995-2026), appraised them with QUADAS-2 and matched instruments, and synthesised narratively. Categories came from titles, abstracts and controlled vocabulary; every prevalence figure is a floor. Duplicate screening achieved substantial agreement (Fleiss' kappa = 0.877); appraisal agreement was substantial (0.788; 0.390 where observable); extraction is unaudited. Results: Only 18 of 263 studies (6.8%) record a fidelity metric and a reader assessment on the same data, leaving the field's central proxy unmeasured. Reader studies mostly measure reader-versus-reader agreement, which is weak: fastMRI 2020 concordance was 0.457 and 0.386 (Kendall's W), improving only where SSIM had diverged. Erasing a 100 mm3 lacunar infarct moves global PSNR about 0.03 dB under the stated error model. The corpus grew fivefold; reader assessment fell from 32% to 18%, recovering to 21%. Among the four largest families the most hallucination-associated (generative, 39%) is among the least reader-evaluated (11.3%); self-supervised is higher still (47%) with no readers. One study in twenty both releases code and runs readers; none evaluated a model observer; no named dataset covers acute stroke or haemorrhage. Conclusions: On these floors, evaluation practice cannot certify diagnostic safety. We derive five requirements safety-oriented evaluation must meet.
- Open Access
Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction
Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.
Open AccessEvaluating the Safety of Deep Learning-Based Brain MRI Reconstruction
Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.
- Open Access
Attenuation of Redox Interference in RuO2 pH Sensor Using a Ta2O5/Nafion Multilayer Architecture
Despite the growing preference for solid-state pH sensors due to their advantages over glass pH electrodes, their practical application is still limited by challenges, particularly in metal-oxide based systems. The main issue is their susceptibility to redox-active species such as dissolved oxygen, ascorbic acid, sulfides, and transition-metal ions. In this work, the effects of representative redox interferents, with particular emphasis on ascorbic acid, together with dissolved oxygen and potassium permanganate, were investigated and mitigated through the application of Ta2O5/Nafion overlayers. The solid-state metal-oxide pH-sensitive electrodes were fabricated with laser micro-etching of radio-frequency (RF) sputtered RuO2 thin films deposited on ceramic Al2O3 substrates. The resulting RuO2 electrodes exhibited excellent potentiometric pH sensing characteristics, including near-Nernstian sensitivity (58.8 mV pH−1 at 25 °C), highly linear response over a wide pH range (pH 2–12, R2 > 0.9999), minimal hysteresis (1.3 mV), low potential drift (2.9 mV h−1), and fast response times (2O5/Nafion solid-state sensor could measure beverage pH accurately, here we explain why that architecture works by systematically investigating the role of Ta2O5 and Nafion in suppressing redox interference and improving measurement stability in complex sample matrices. The results demonstrate that RuO2 electrodes modified with combined Ta2O5/Nafion thin films exhibit significantly enhanced measurement stability compared to unmodified RuO2 electrodes, owing to effective suppression of potential fluctuations induced by dissolved oxygen and representative redox couples, particularly those associated with ascorbic acid interference. These findings could give a promising strategy for improving the robustness and reliability of solid-state RuO2-based pH sensors in complex electrochemical environments.
Open AccessAttenuation of Redox Interference in RuO2 pH Sensor Using a Ta2O5/Nafion Multilayer Architecture
Despite the growing preference for solid-state pH sensors due to their advantages over glass pH electrodes, their practical application is still limited by challenges, particularly in metal-oxide based systems. The main issue is their susceptibility to redox-active species such as dissolved oxygen, ascorbic acid, sulfides, and transition-metal ions. In this work, the effects of representative redox interferents, with particular emphasis on ascorbic acid, together with dissolved oxygen and potassium permanganate, were investigated and mitigated through the application of Ta2O5/Nafion overlayers. The solid-state metal-oxide pH-sensitive electrodes were fabricated with laser micro-etching of radio-frequency (RF) sputtered RuO2 thin films deposited on ceramic Al2O3 substrates. The resulting RuO2 electrodes exhibited excellent potentiometric pH sensing characteristics, including near-Nernstian sensitivity (58.8 mV pH−1 at 25 °C), highly linear response over a wide pH range (pH 2–12, R2 > 0.9999), minimal hysteresis (1.3 mV), low potential drift (2.9 mV h−1), and fast response times (2O5/Nafion solid-state sensor could measure beverage pH accurately, here we explain why that architecture works by systematically investigating the role of Ta2O5 and Nafion in suppressing redox interference and improving measurement stability in complex sample matrices. The results demonstrate that RuO2 electrodes modified with combined Ta2O5/Nafion thin films exhibit significantly enhanced measurement stability compared to unmodified RuO2 electrodes, owing to effective suppression of potential fluctuations induced by dissolved oxygen and representative redox couples, particularly those associated with ascorbic acid interference. These findings could give a promising strategy for improving the robustness and reliability of solid-state RuO2-based pH sensors in complex electrochemical environments.
- Open Access
Unlearning Imperative: Securing Trustworthy and Responsible LLMs through Engineered Forgetting
The growing use of large language models in sensitive domains has exposed a critical weakness: the inability to ensure that private information can be permanently forgotten. Yet these systems still lack reliable mechanisms to guarantee that sensitive information can be permanently removed once it has been used. Retraining from the beginning is prohibitively costly, and existing unlearning methods remain fragmented, difficult to verify, and often vulnerable to recovery. This paper surveys recent research on machine unlearning for LLMs and considers how far current approaches can address these challenges. We review methods for evaluating whether forgetting has occurred, the resilience of unlearned models against adversarial attacks, and mechanisms that can support user trust when model complexity or proprietary limits restrict transparency. Technical solutions such as differential privacy, homomorphic encryption, federated learning, and ephemeral memory are examined alongside institutional safeguards including auditing practices and regulatory frameworks. The review finds steady progress, but robust and verifiable unlearning is still unresolved. Efficient techniques that avoid costly retraining, stronger defenses against adversarial recovery, and governance structures that reinforce accountability are needed if LLMs are to be deployed safely in sensitive applications. By integrating technical and organizational perspectives, this study outlines a pathway toward AI systems that can be required to forget, while maintaining both privacy and public trust.
Open AccessUnlearning Imperative: Securing Trustworthy and Responsible LLMs through Engineered Forgetting
The growing use of large language models in sensitive domains has exposed a critical weakness: the inability to ensure that private information can be permanently forgotten. Yet these systems still lack reliable mechanisms to guarantee that sensitive information can be permanently removed once it has been used. Retraining from the beginning is prohibitively costly, and existing unlearning methods remain fragmented, difficult to verify, and often vulnerable to recovery. This paper surveys recent research on machine unlearning for LLMs and considers how far current approaches can address these challenges. We review methods for evaluating whether forgetting has occurred, the resilience of unlearned models against adversarial attacks, and mechanisms that can support user trust when model complexity or proprietary limits restrict transparency. Technical solutions such as differential privacy, homomorphic encryption, federated learning, and ephemeral memory are examined alongside institutional safeguards including auditing practices and regulatory frameworks. The review finds steady progress, but robust and verifiable unlearning is still unresolved. Efficient techniques that avoid costly retraining, stronger defenses against adversarial recovery, and governance structures that reinforce accountability are needed if LLMs are to be deployed safely in sensitive applications. By integrating technical and organizational perspectives, this study outlines a pathway toward AI systems that can be required to forget, while maintaining both privacy and public trust.
- 16 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (5) , 7886-7895
Advancements in Solid-State Metal pH Sensors: A Comprehensive Review of Metal Oxides and Nitrides for Enhanced Chemical Sensing: A Review
Solid-state pH sensors have emerged as vital tools across various scientific and industrial applications, from agriculture and environmental monitoring to biotechnology and the pharmaceutical industry. Among pH sensing devices, conventional glass electrodes have long been the standard due to their Nernstian sensitivity, wide operating range, and excellent ion selectivity. However, glass electrodes present significant drawbacks, including fragility, storage limitations, and difficulty in miniaturization for applications like capsule endoscopy and in vivo pH monitoring. To overcome these challenges, researchers have explored alternative materials for solid-state pH sensing, particularly focusing on metal oxides and nitrides. This paper presents a comprehensive review of solid-state metal pH sensors, with an emphasis on the potential of metal nitrides to address the limitations of glass electrodes and metal oxides. Metal oxides, despite their robustness and ability to be miniaturized, often face interference in redox environments, reducing their sensitivity. In contrast, metal nitrides, known for their superior chemical inertness, thermal stability, and mechanical strength, offer promising characteristics for pH sensing, particularly in challenging sample matrices. By reviewing the latest developments in the field, this paper explores the structure-property relationships that make metal nitrides excellent candidates for next-generation pH sensors. Moreover, this review outlines the key principles behind potentiometric and amperometric sensing techniques, highlighting the various fabrication methods used for solid-state electrodes. Special attention is given to different sensing materials, including liquid hydrophobic membranes, carbon-based materials, conducting polymers, and the role of functional groups in optimizing the sensing performance of each material. Additionally, the paper addresses the limitations of metal oxides in redox environments and provides a comparative analysis of their sensitivity to pH changes, while discussing potential improvements in electrode performance through innovative material selection and design.
- 16 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (5) , 7886-7895
Advancements in Solid-State Metal pH Sensors: A Comprehensive Review of Metal Oxides and Nitrides for Enhanced Chemical Sensing: A Review
Solid-state pH sensors have emerged as vital tools across various scientific and industrial applications, from agriculture and environmental monitoring to biotechnology and the pharmaceutical industry. Among pH sensing devices, conventional glass electrodes have long been the standard due to their Nernstian sensitivity, wide operating range, and excellent ion selectivity. However, glass electrodes present significant drawbacks, including fragility, storage limitations, and difficulty in miniaturization for applications like capsule endoscopy and in vivo pH monitoring. To overcome these challenges, researchers have explored alternative materials for solid-state pH sensing, particularly focusing on metal oxides and nitrides. This paper presents a comprehensive review of solid-state metal pH sensors, with an emphasis on the potential of metal nitrides to address the limitations of glass electrodes and metal oxides. Metal oxides, despite their robustness and ability to be miniaturized, often face interference in redox environments, reducing their sensitivity. In contrast, metal nitrides, known for their superior chemical inertness, thermal stability, and mechanical strength, offer promising characteristics for pH sensing, particularly in challenging sample matrices. By reviewing the latest developments in the field, this paper explores the structure-property relationships that make metal nitrides excellent candidates for next-generation pH sensors. Moreover, this review outlines the key principles behind potentiometric and amperometric sensing techniques, highlighting the various fabrication methods used for solid-state electrodes. Special attention is given to different sensing materials, including liquid hydrophobic membranes, carbon-based materials, conducting polymers, and the role of functional groups in optimizing the sensing performance of each material. Additionally, the paper addresses the limitations of metal oxides in redox environments and provides a comparative analysis of their sensitivity to pH changes, while discussing potential improvements in electrode performance through innovative material selection and design.
- 4 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (8) , 12498-12503
Effect of Post Deposition Annealing on the Sensing Properties of Thin Film Ruthenium Oxide (RuO₂) pH Sensor
The use of Ruthenium Oxide (RuO2) as a pH sensor is a relatively novel idea and understanding how preparation of the sensor effects and its sensing properties is crucial. In this paper, the effect of annealing temperature on the sensing properties of the sputtered RuO 2 thin film pH sensor was examined. It was found that annealing RuO 2 at temperatures above 200 °C resulted in increased crystallinity and did not significantly alter the elemental composition. The sensor performance however was found to decrease with increased annealing temperature. Electrodes annealed above 400 °C had significantly higher hysteresis widths and drift rates, almost 10 times the values of electrodes annealed at below 400 °C. Electrodes annealed at temperatures below 400 °C exhibited acceptable hysteresis widths of less than 2.5 mV. Consequently, in the manufacture of functional RuO 2 pH sensors with a screen-printed Pt contact layer, it is recommended that the manufacturing temperature should not exceed 400 °C, post sputter deposition of RuO 2 .
- 4 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (8) , 12498-12503
Effect of Post Deposition Annealing on the Sensing Properties of Thin Film Ruthenium Oxide (RuO₂) pH Sensor
The use of Ruthenium Oxide (RuO2) as a pH sensor is a relatively novel idea and understanding how preparation of the sensor effects and its sensing properties is crucial. In this paper, the effect of annealing temperature on the sensing properties of the sputtered RuO 2 thin film pH sensor was examined. It was found that annealing RuO 2 at temperatures above 200 °C resulted in increased crystallinity and did not significantly alter the elemental composition. The sensor performance however was found to decrease with increased annealing temperature. Electrodes annealed above 400 °C had significantly higher hysteresis widths and drift rates, almost 10 times the values of electrodes annealed at below 400 °C. Electrodes annealed at temperatures below 400 °C exhibited acceptable hysteresis widths of less than 2.5 mV. Consequently, in the manufacture of functional RuO 2 pH sensors with a screen-printed Pt contact layer, it is recommended that the manufacturing temperature should not exceed 400 °C, post sputter deposition of RuO 2 .
- Top Cited PapersOpen Access
- 12 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 11 (6) , 9610-9629
MalBoT-DRL: Malware Botnet Detection Using Deep Reinforcement Learning in IoT Networks
In the dynamic landscape of cyber threats, multistage malware botnets have surfaced as significant threats of concern. These sophisticated threats can exploit Internet of Things (IoT) devices to undertake an array of cyberattacks, ranging from basic infections to complex operations, such as phishing, cryptojacking, and Distributed Denial-of-Service (DDoS) attacks. Existing machine learning solutions are often constrained by their limited generalizability across various data sets and their inability to adapt to the mutable patterns of malware attacks in real world environments, a challenge known as model drift. This limitation highlights the pressing need for adaptive intrusion detection systems (IDSs), capable of adjusting to evolving threat patterns and new or unseen attacks. This article introduces MalBoT-DRL, a robust malware botnet detector using deep reinforcement learning (RL). Designed to detect botnets throughout their entire lifecycle, MalBoT-DRL has better generalizability and offers a resilient solution to model drift. This model integrates damped incremental statistics with an attention reward mechanism, a combination that has not been extensively explored in the literature. This integration enables MalBoT-DRL to dynamically adapt to the ever-changing malware patterns within IoT environments. The performance of MalBoT-DRL has been validated via trace-driven experiments using two representative data sets: 1) MedBIoT and 2) N-BaIoT, resulting in exceptional average detection rates of 99.80% and 99.40% in the early and late detection phases, respectively. To the best of our knowledge, this work introduces one of the first studies to investigate the efficacy of RL in enhancing the generalizability of IDS.
- 12 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 11 (6) , 9610-9629
Top Cited PapersOpen AccessMalBoT-DRL: Malware Botnet Detection Using Deep Reinforcement Learning in IoT Networks
In the dynamic landscape of cyber threats, multistage malware botnets have surfaced as significant threats of concern. These sophisticated threats can exploit Internet of Things (IoT) devices to undertake an array of cyberattacks, ranging from basic infections to complex operations, such as phishing, cryptojacking, and Distributed Denial-of-Service (DDoS) attacks. Existing machine learning solutions are often constrained by their limited generalizability across various data sets and their inability to adapt to the mutable patterns of malware attacks in real world environments, a challenge known as model drift. This limitation highlights the pressing need for adaptive intrusion detection systems (IDSs), capable of adjusting to evolving threat patterns and new or unseen attacks. This article introduces MalBoT-DRL, a robust malware botnet detector using deep reinforcement learning (RL). Designed to detect botnets throughout their entire lifecycle, MalBoT-DRL has better generalizability and offers a resilient solution to model drift. This model integrates damped incremental statistics with an attention reward mechanism, a combination that has not been extensively explored in the literature. This integration enables MalBoT-DRL to dynamically adapt to the ever-changing malware patterns within IoT environments. The performance of MalBoT-DRL has been validated via trace-driven experiments using two representative data sets: 1) MedBIoT and 2) N-BaIoT, resulting in exceptional average detection rates of 99.80% and 99.40% in the early and late detection phases, respectively. To the best of our knowledge, this work introduces one of the first studies to investigate the efficacy of RL in enhancing the generalizability of IDS.
- Open Access
- 17 May 2023
- Published by Elsevier in Computer Networks
- Vol. 231
DoS/DDoS-MQTT-IoT: A dataset for evaluating intrusions in IoT networks using the MQTT protocol
- 17 May 2023
- Published by Elsevier in Computer Networks
- Vol. 231
Open AccessDoS/DDoS-MQTT-IoT: A dataset for evaluating intrusions in IoT networks using the MQTT protocol
- Top Cited PapersOpen Access
A Comprehensive Review on Machine Learning in Healthcare Industry: Classification, Restrictions, Opportunities and Challenges
Recently, various sophisticated methods, including machine learning and artificial intelligence, have been employed to examine health-related data. Medical professionals are acquiring enhanced diagnostic and treatment abilities by utilizing machine learning applications in the healthcare domain. Medical data have been used by many researchers to detect diseases and identify patterns. In the current literature, there are very few studies that address machine learning algorithms to improve healthcare data accuracy and efficiency. We examined the effectiveness of machine learning algorithms in improving time series healthcare metrics for heart rate data transmission (accuracy and efficiency). In this paper, we reviewed several machine learning algorithms in healthcare applications. After a comprehensive overview and investigation of supervised and unsupervised machine learning algorithms, we also demonstrated time series tasks based on past values (along with reviewing their feasibility for both small and large datasets).
Top Cited PapersOpen AccessA Comprehensive Review on Machine Learning in Healthcare Industry: Classification, Restrictions, Opportunities and Challenges
Recently, various sophisticated methods, including machine learning and artificial intelligence, have been employed to examine health-related data. Medical professionals are acquiring enhanced diagnostic and treatment abilities by utilizing machine learning applications in the healthcare domain. Medical data have been used by many researchers to detect diseases and identify patterns. In the current literature, there are very few studies that address machine learning algorithms to improve healthcare data accuracy and efficiency. We examined the effectiveness of machine learning algorithms in improving time series healthcare metrics for heart rate data transmission (accuracy and efficiency). In this paper, we reviewed several machine learning algorithms in healthcare applications. After a comprehensive overview and investigation of supervised and unsupervised machine learning algorithms, we also demonstrated time series tasks based on past values (along with reviewing their feasibility for both small and large datasets).
- Open Access
Nafion Modified Titanium Nitride pH Sensor for Future Biomedical Applications
PH sensors are increasingly being utilized in the biomedical field and have been implicated in health applications that aim to improve the monitoring and treatment of patients. In this work, a previously developed Titanium Nitride (TiN) solid-state pH sensor is further enhanced, with the potential to be used for pH regulation inside the human body and for other biomedical, industrial, and environmental applications. One of the main limitations of existing solid-state pH sensors is their reduced performance in high redox mediums. The potential shift E0 value of the previously developed TiN pH electrode in the presence of oxidizing or reducing agents is 30 mV. To minimize this redox shift, a Nafion-modified TiN electrode was developed, tested, and evaluated in various mediums. The Nafion-modified electrode has been shown to shift the E0 value by only 2 mV, providing increased accuracy in highly redox samples while maintaining acceptable reaction times. Overcoming the redox interference for pH measurement enables several advantages of the Nafion-modified TiN electrode over the standard pH glass electrode, implicating its use in medical diagnosis, real-time health monitoring, and further development of miniaturized smart sensors.
Open AccessNafion Modified Titanium Nitride pH Sensor for Future Biomedical Applications
PH sensors are increasingly being utilized in the biomedical field and have been implicated in health applications that aim to improve the monitoring and treatment of patients. In this work, a previously developed Titanium Nitride (TiN) solid-state pH sensor is further enhanced, with the potential to be used for pH regulation inside the human body and for other biomedical, industrial, and environmental applications. One of the main limitations of existing solid-state pH sensors is their reduced performance in high redox mediums. The potential shift E0 value of the previously developed TiN pH electrode in the presence of oxidizing or reducing agents is 30 mV. To minimize this redox shift, a Nafion-modified TiN electrode was developed, tested, and evaluated in various mediums. The Nafion-modified electrode has been shown to shift the E0 value by only 2 mV, providing increased accuracy in highly redox samples while maintaining acceptable reaction times. Overcoming the redox interference for pH measurement enables several advantages of the Nafion-modified TiN electrode over the standard pH glass electrode, implicating its use in medical diagnosis, real-time health monitoring, and further development of miniaturized smart sensors.