Linfeng Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Linfeng Lu has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Hanlin Hao
School of Civil Engineering, Chang’an University, 75 Chang’an Middle Rd, Xi’an 710061, China
5 shared publications - Bingyou Liu
School of Civil Engineering, Chang’an University, 75 Chang’an Middle Rd, Xi’an 710061, China
4 shared publications Wei Wang
Univ Waikato, Sch Engn, Hamilton 3216, New Zealand
4 shared publications- Di Wang
China Construction Third Bureau Group Co., Ltd., Mai Hua Rd, Nanjing 210004, China
2 shared publications Hanheng Wu
2 shared publicationsHao Peng
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 45, 9913-9927
Retrospective residual-ligament characterization of all-unbroken Charpy tests in structural steels
- 16 November 2026
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 45, 9913-9927
Open AccessRetrospective residual-ligament characterization of all-unbroken Charpy tests in structural steels
- 30 January 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 513
Coating protection and corrosion allowance in structural steels: Experimental validation and design implications
- 30 January 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 513
Coating protection and corrosion allowance in structural steels: Experimental validation and design implications
- Open Access
Slip Factors of Coated Faying Surfaces in High-Strength Bolted Connections: Experimental Evaluation and Code Implications
To evaluate the slip resistance of high-strength bolted friction-type connections subjected to different corrosion-protection treatments, calibration tests were performed on six representative faying-surface conditions: sand-blasted (uncoated), epoxy zinc-rich primer, waterborne inorganic zinc-rich coating, alcohol-soluble inorganic anti-corrosion anti-slip primer, a complete multi-layer protective coating system, and cold galvanizing. Fifteen test groups comprising 45 tensile specimens were examined to determine slip factors, which were then compared with values recommended in domestic and international design standards. The results show that sand-blasted surfaces (W type) exhibit stable slip factors of μ = 0.43–0.45; alcohol-soluble inorganic primer surfaces (S type) provide the highest slip resistance with μ = 0.49–0.51, representing an increase of approximately 13%–18% compared with sand-blasted surfaces; and cold-galvanized surfaces (D type) achieve favourable performance with μ ≈ 0.44. Waterborne inorganic zinc-rich surfaces (A type) yield μ ≈ 0.33, corresponding to a reduction of about 25%, and are suitable for non-slip-critical connections. In contrast, epoxy zinc-rich primers (C type) and complete multi-layer coating systems (X type) present lower slip factors of μ = 0.26–0.28 and μ ≈ 0.23, corresponding to reductions of approximately 35%–45% and about 50%, respectively, indicating that the X-type treatment is unsuitable for slip-critical applications. The influence of bolt diameter is limited, with slip-factor variations within 5%–8% under the same surface condition, and no statistically significant effect confirmed by two-way ANOVA. These findings provide a quantitative experimental basis for the design, classification, and future standardization of friction-type bolted connections with coated faying surfaces.
Open AccessSlip Factors of Coated Faying Surfaces in High-Strength Bolted Connections: Experimental Evaluation and Code Implications
To evaluate the slip resistance of high-strength bolted friction-type connections subjected to different corrosion-protection treatments, calibration tests were performed on six representative faying-surface conditions: sand-blasted (uncoated), epoxy zinc-rich primer, waterborne inorganic zinc-rich coating, alcohol-soluble inorganic anti-corrosion anti-slip primer, a complete multi-layer protective coating system, and cold galvanizing. Fifteen test groups comprising 45 tensile specimens were examined to determine slip factors, which were then compared with values recommended in domestic and international design standards. The results show that sand-blasted surfaces (W type) exhibit stable slip factors of μ = 0.43–0.45; alcohol-soluble inorganic primer surfaces (S type) provide the highest slip resistance with μ = 0.49–0.51, representing an increase of approximately 13%–18% compared with sand-blasted surfaces; and cold-galvanized surfaces (D type) achieve favourable performance with μ ≈ 0.44. Waterborne inorganic zinc-rich surfaces (A type) yield μ ≈ 0.33, corresponding to a reduction of about 25%, and are suitable for non-slip-critical connections. In contrast, epoxy zinc-rich primers (C type) and complete multi-layer coating systems (X type) present lower slip factors of μ = 0.26–0.28 and μ ≈ 0.23, corresponding to reductions of approximately 35%–45% and about 50%, respectively, indicating that the X-type treatment is unsuitable for slip-critical applications. The influence of bolt diameter is limited, with slip-factor variations within 5%–8% under the same surface condition, and no statistically significant effect confirmed by two-way ANOVA. These findings provide a quantitative experimental basis for the design, classification, and future standardization of friction-type bolted connections with coated faying surfaces.
- Open Access
Weak-Axis Double Reduced Beam Section Connection: Seismic Performance Analysis and Design Method
A weak-axis moment connection incorporating a double reduced beam section and a box-reinforced panel zone (WDRBS) is introduced for hot-rolled H-shaped columns. The configuration is intended to shift inelastic demand away from the column face and to constrain weak-axis panel-zone distortion. A series of finite element models is established and calibrated to examine the cyclic response of this connection type. By varying the geometric parameters of the second reduction zone, a closed-form expression for determining its cutting depth (c2) is formulated, allowing both reduced regions to yield concurrently, i.e., the Optimum State. The numerical investigation demonstrates that connections designed according to this equation exhibit stable hysteresis, limited weld-adjacent plastic ll rightstrain, and sufficient deformation and energy-dissipation capacities. All specimens exhibit plastic rotations greater than 0.03 rad, ductility ratios greater than 3.0, and equivalent viscous damping ratios greater than 0.3. To facilitate engineering implementation using common hot-rolled sections, a simplified method is further proposed to approximate the admissible range of c2 with practical accuracy. While the length of the second reduction region has only a modest influence on peak strength (approximately 1.5–6%), it markedly affects the failure mechanism and plastic-hinge distribution. A stepwise design procedure for WDRBS connections is accordingly recommended. The study does not consider composite-slab interaction or gravity-load effects, and the findings—based solely on finite element simulations—require future verification through full-scale experimental testing.
Open AccessWeak-Axis Double Reduced Beam Section Connection: Seismic Performance Analysis and Design Method
A weak-axis moment connection incorporating a double reduced beam section and a box-reinforced panel zone (WDRBS) is introduced for hot-rolled H-shaped columns. The configuration is intended to shift inelastic demand away from the column face and to constrain weak-axis panel-zone distortion. A series of finite element models is established and calibrated to examine the cyclic response of this connection type. By varying the geometric parameters of the second reduction zone, a closed-form expression for determining its cutting depth (c2) is formulated, allowing both reduced regions to yield concurrently, i.e., the Optimum State. The numerical investigation demonstrates that connections designed according to this equation exhibit stable hysteresis, limited weld-adjacent plastic ll rightstrain, and sufficient deformation and energy-dissipation capacities. All specimens exhibit plastic rotations greater than 0.03 rad, ductility ratios greater than 3.0, and equivalent viscous damping ratios greater than 0.3. To facilitate engineering implementation using common hot-rolled sections, a simplified method is further proposed to approximate the admissible range of c2 with practical accuracy. While the length of the second reduction region has only a modest influence on peak strength (approximately 1.5–6%), it markedly affects the failure mechanism and plastic-hinge distribution. A stepwise design procedure for WDRBS connections is accordingly recommended. The study does not consider composite-slab interaction or gravity-load effects, and the findings—based solely on finite element simulations—require future verification through full-scale experimental testing.
- Open Access
Seismic Vulnerability Assessment of Residential RC Buildings in Yemen Using Incremental Dynamic Analysis (IDA)
Traditional buildings constructed in Yemen during the 20th century often lacked adequate seismic protection. Today, most reinforced concrete (RC) residential buildings in the country are designed with beam–column systems that primarily carry gravity loads without considering lateral seismic forces. As a result, these structures are potentially vulnerable to earthquakes and require further investigation. This study aims to develop analytical seismic fragility curves for residential RC buildings in Yemen with varied heights. Three building heights were considered, namely three, five, and seven stories. While in most studies, the infill walls are regarded as non-structural elements, and their contributions to resisting earthquake actions are ignored, in this study, the contribution of the infill wall was taken into account by utilizing a compression strut modeling of the infill wall. In addition, an investigation was conducted to study the effect of soft stories on the seismic vulnerability of residential RC buildings. Finite element models were developed, and 900 Incremental Dynamic Analyses (IDAs) were conducted. Three damage limit states were defined: Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Based on these results, cumulative distribution functions (CDFs) were calculated to derive the seismic fragility curves. The findings indicate that taller buildings are more likely to reach or exceed the defined damage states, making them more vulnerable to earthquakes. Infilled frame structures demonstrate better seismic performance due to the contribution of infill walls to lateral resistance. In contrast, buildings with soft stories are more vulnerable due to abrupt changes in stiffness, resulting in greater deformation concentration in the soft story. The developed fragility curves provide a quantitative basis for assessing seismic damage in Yemeni RC residential buildings and offer a foundation for future seismic risk evaluations.
Open AccessSeismic Vulnerability Assessment of Residential RC Buildings in Yemen Using Incremental Dynamic Analysis (IDA)
Traditional buildings constructed in Yemen during the 20th century often lacked adequate seismic protection. Today, most reinforced concrete (RC) residential buildings in the country are designed with beam–column systems that primarily carry gravity loads without considering lateral seismic forces. As a result, these structures are potentially vulnerable to earthquakes and require further investigation. This study aims to develop analytical seismic fragility curves for residential RC buildings in Yemen with varied heights. Three building heights were considered, namely three, five, and seven stories. While in most studies, the infill walls are regarded as non-structural elements, and their contributions to resisting earthquake actions are ignored, in this study, the contribution of the infill wall was taken into account by utilizing a compression strut modeling of the infill wall. In addition, an investigation was conducted to study the effect of soft stories on the seismic vulnerability of residential RC buildings. Finite element models were developed, and 900 Incremental Dynamic Analyses (IDAs) were conducted. Three damage limit states were defined: Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Based on these results, cumulative distribution functions (CDFs) were calculated to derive the seismic fragility curves. The findings indicate that taller buildings are more likely to reach or exceed the defined damage states, making them more vulnerable to earthquakes. Infilled frame structures demonstrate better seismic performance due to the contribution of infill walls to lateral resistance. In contrast, buildings with soft stories are more vulnerable due to abrupt changes in stiffness, resulting in greater deformation concentration in the soft story. The developed fragility curves provide a quantitative basis for assessing seismic damage in Yemeni RC residential buildings and offer a foundation for future seismic risk evaluations.
- Open Access
Lateral-Torsional Buckling Behavior of Low-Carbon H-Shape Bolted Composite Beams
The construction industry faces increasing pressure to reduce energy consumption and carbon emissions. Promoting sustainable practices, such as using hot-rolled H-shapes and minimizing welding, can address these challenges. This study introduces low-carbon H-shape bolted composite beams (HBCBs) as a sustainable alternative. Experimental and numerical investigations into the lateral-torsional buckling behavior of HBCBs demonstrated that high-strength bolts significantly enhance structural stability and capacity. A reliable simulation method was developed and validated based on experimental results. The study reveals that bolt spacing exceeding 1/15 of the beam span has negligible effects on load-bearing capacity, and HBCB performance reaches approximately 95% of plug-welded counterparts. Despite this, longitudinal slip reduction remains challenging, warranting further research to optimize performance.
Open AccessLateral-Torsional Buckling Behavior of Low-Carbon H-Shape Bolted Composite Beams
The construction industry faces increasing pressure to reduce energy consumption and carbon emissions. Promoting sustainable practices, such as using hot-rolled H-shapes and minimizing welding, can address these challenges. This study introduces low-carbon H-shape bolted composite beams (HBCBs) as a sustainable alternative. Experimental and numerical investigations into the lateral-torsional buckling behavior of HBCBs demonstrated that high-strength bolts significantly enhance structural stability and capacity. A reliable simulation method was developed and validated based on experimental results. The study reveals that bolt spacing exceeding 1/15 of the beam span has negligible effects on load-bearing capacity, and HBCB performance reaches approximately 95% of plug-welded counterparts. Despite this, longitudinal slip reduction remains challenging, warranting further research to optimize performance.
- Open Access
- 13 January 2025
- Published by MDPI AG in Preprints.org
Lateral-torsional Buckling Behavior of Low-Carbon H-Shape Bolted-composited Beams(HBCBs)
The construction industry faces increasing pressure to reduce energy consumption and carbon emissions. Promoting sustainable practices, such as using hot-rolled H-shapes and minimizing welding, can address these challenges. This study introduces Low-Carbon H-Shape Bolted-Composited Beams (HBCBs) as a sustainable alternative. Experimental and numerical investigations into the lateral-torsional buckling behavior of HBCBs demonstrated that high-strength bolts significantly enhance structural stability and capacity. A reliable simulation method was developed and validated based on experimental results. The study revealed that bolt spacing exceeding 1/15 of the beam span has negligible effects on load-bearing capacity, and HBCB performance reaches approximately 95% of plug-welded counterparts. Despite this, longitudinal slip reduction remains challenging, warranting further research to optimize performance.
- 13 January 2025
- Published by MDPI AG in Preprints.org
Open AccessLateral-torsional Buckling Behavior of Low-Carbon H-Shape Bolted-composited Beams(HBCBs)
The construction industry faces increasing pressure to reduce energy consumption and carbon emissions. Promoting sustainable practices, such as using hot-rolled H-shapes and minimizing welding, can address these challenges. This study introduces Low-Carbon H-Shape Bolted-Composited Beams (HBCBs) as a sustainable alternative. Experimental and numerical investigations into the lateral-torsional buckling behavior of HBCBs demonstrated that high-strength bolts significantly enhance structural stability and capacity. A reliable simulation method was developed and validated based on experimental results. The study revealed that bolt spacing exceeding 1/15 of the beam span has negligible effects on load-bearing capacity, and HBCB performance reaches approximately 95% of plug-welded counterparts. Despite this, longitudinal slip reduction remains challenging, warranting further research to optimize performance.
- Open Access
Effects of Cover-Plate Geometry on the Mechanical Behavior of Steel Frame Joints with Middle-Flange and Wide-Flange H-Beams
This study investigates the mechanical behavior of cover-plate reinforced connections in steel frames with I-section columns and middle- or wide-flange H-beams, addressing gaps in current design standards. Finite element analyses validated by experimental data were employed to explore the effects of cover-plate geometry—shape, length, and thickness—on seismic performance. Results demonstrate that cover plates improve load-bearing capacity and ductility by relocating plastic hinges outward from joint regions. Specifically, cover-plate connections increased ductility by 25%, yield moment by 15%, and initial rotational stiffness by 7% compared to non-reinforced connections. The shape of the top cover plate had minimal impact on mechanical behavior. The cover-plate length and thickness significantly influenced seismic ductility and load-bearing capacity. The cover-plate thickness should be at least 0.3 times the beam flange thickness (not less than 6 mm) while ensuring the combined thickness of the cover plate and beam flange does not exceed the column flange thickness. These recommendations address the conservatism of existing standards, balancing material efficiency and seismic performance. Optimal cover-plate lengths of 0.7 to 0.9 times the beam depth were also identified. These findings provide practical guidelines for designing resilient steel frame connections in seismic regions.
Open AccessEffects of Cover-Plate Geometry on the Mechanical Behavior of Steel Frame Joints with Middle-Flange and Wide-Flange H-Beams
This study investigates the mechanical behavior of cover-plate reinforced connections in steel frames with I-section columns and middle- or wide-flange H-beams, addressing gaps in current design standards. Finite element analyses validated by experimental data were employed to explore the effects of cover-plate geometry—shape, length, and thickness—on seismic performance. Results demonstrate that cover plates improve load-bearing capacity and ductility by relocating plastic hinges outward from joint regions. Specifically, cover-plate connections increased ductility by 25%, yield moment by 15%, and initial rotational stiffness by 7% compared to non-reinforced connections. The shape of the top cover plate had minimal impact on mechanical behavior. The cover-plate length and thickness significantly influenced seismic ductility and load-bearing capacity. The cover-plate thickness should be at least 0.3 times the beam flange thickness (not less than 6 mm) while ensuring the combined thickness of the cover plate and beam flange does not exceed the column flange thickness. These recommendations address the conservatism of existing standards, balancing material efficiency and seismic performance. Optimal cover-plate lengths of 0.7 to 0.9 times the beam depth were also identified. These findings provide practical guidelines for designing resilient steel frame connections in seismic regions.
- Open Access
Hysteretic Behavior Study on the RBS Connection of H-Shape Columns with Middle-Flanges or Wide-Flange H-Shape Beams
Existing research on reduced beam section (RBS) connections in steel frames rarely addresses H-shaped beams with middle and wide flanges. Therefore, this study investigates the hysteretic behavior of RBS connections in H-shaped columns connected to H-shaped beams with middle and wide flanges. Using finite element analysis, the influence of key parameters (a, b, and c, where “a” represents the unweakened beam flange extension length, “b” represents the weakened beam flange length, and “c” represents the weakened beam flange depth, respectively) on structural performance was evaluated, focusing on rotational stiffness, load-carrying capacity, plastic rotation capacity, and ductility. The results indicate that increasing a enhances initial rotational stiffness and load capacity but reduces plastic rotation and ductility, making lower a values (near 0.5bf) optimal for ductile performance. Similarly, higher b values (up to 0.85bf) marginally reduce stiffness and load capacity, improving plastic rotation capacity, with a greater benefit in wide-flange beams. Meanwhile, a lower c value (around 0.20bf) offered balanced performance, with higher c values decreasing stiffness and load capacity but enhancing ductility. Overall, wider flanges improve plastic rotation and ductility but slightly decrease rotational stiffness, providing insights to guide RBS connection designs for seismic resilience.
Open AccessHysteretic Behavior Study on the RBS Connection of H-Shape Columns with Middle-Flanges or Wide-Flange H-Shape Beams
Existing research on reduced beam section (RBS) connections in steel frames rarely addresses H-shaped beams with middle and wide flanges. Therefore, this study investigates the hysteretic behavior of RBS connections in H-shaped columns connected to H-shaped beams with middle and wide flanges. Using finite element analysis, the influence of key parameters (a, b, and c, where “a” represents the unweakened beam flange extension length, “b” represents the weakened beam flange length, and “c” represents the weakened beam flange depth, respectively) on structural performance was evaluated, focusing on rotational stiffness, load-carrying capacity, plastic rotation capacity, and ductility. The results indicate that increasing a enhances initial rotational stiffness and load capacity but reduces plastic rotation and ductility, making lower a values (near 0.5bf) optimal for ductile performance. Similarly, higher b values (up to 0.85bf) marginally reduce stiffness and load capacity, improving plastic rotation capacity, with a greater benefit in wide-flange beams. Meanwhile, a lower c value (around 0.20bf) offered balanced performance, with higher c values decreasing stiffness and load capacity but enhancing ductility. Overall, wider flanges improve plastic rotation and ductility but slightly decrease rotational stiffness, providing insights to guide RBS connection designs for seismic resilience.
- Open Access
Analysis of Factors Affecting the Seismic Performance of Widened Flange Connections in Mid-Flange H-Beams and Box Columns
Following the Northridge and Kobe earthquakes, research has increasingly focused on achieving high ductility in beam-to-column connections. This study investigates the seismic performance of connections featuring widened beam-end flanges in mid-flange H-beams and box columns, an area with limited prior research compared to I-section columns and narrow-flange H-beams. Detailed finite element modeling using ABAQUS 6.1.4 demonstrates that widened beam-end flanges significantly improve bending capacity and ductility by relocating the plastic hinge away from the connection, thereby enhancing seismic resilience. Key findings include the identification of optimal design parameters: flange length ranging from 0.55 to 0.75 times the beam flange width, beam flange cutting length between 0.36 and 0.39 times the beam depth, and flange cutting depth from 0.19 to 0.23 times the beam flange width. These parameters ensure effective plastic hinge development and improved structural performance. This study introduces a novel approach that emphasizes geometric optimization over material-based enhancements, offering a cost-effective and practical solution for improving seismic performance and extending previous research insights.
Open AccessAnalysis of Factors Affecting the Seismic Performance of Widened Flange Connections in Mid-Flange H-Beams and Box Columns
Following the Northridge and Kobe earthquakes, research has increasingly focused on achieving high ductility in beam-to-column connections. This study investigates the seismic performance of connections featuring widened beam-end flanges in mid-flange H-beams and box columns, an area with limited prior research compared to I-section columns and narrow-flange H-beams. Detailed finite element modeling using ABAQUS 6.1.4 demonstrates that widened beam-end flanges significantly improve bending capacity and ductility by relocating the plastic hinge away from the connection, thereby enhancing seismic resilience. Key findings include the identification of optimal design parameters: flange length ranging from 0.55 to 0.75 times the beam flange width, beam flange cutting length between 0.36 and 0.39 times the beam depth, and flange cutting depth from 0.19 to 0.23 times the beam flange width. These parameters ensure effective plastic hinge development and improved structural performance. This study introduces a novel approach that emphasizes geometric optimization over material-based enhancements, offering a cost-effective and practical solution for improving seismic performance and extending previous research insights.