Ke Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ke Gong has a total of 405 co-authors. Here are the top co-authors by number of shared publications:
- Rui Qiao
Institude of high energy physics
9 shared publications Wen-Xi Peng
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
5 shared publications- Fei Zhang
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences , Beijing 100049, China
4 shared publications - Hui Wang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
4 shared publications - Ya-Qing Liu
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publications - Zheng-Hua An
Institute of High Energy Physics Key Laboratory of Particle Astrophysics Chinese Academy of Sciences 100049 Beijing China
4 shared publications
Latest Publications
- 8 May 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (7) , 1-11
Design of a silicon charge detector readout system for beam test
- 8 May 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (7) , 1-11
Design of a silicon charge detector readout system for beam test
- 27 March 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (4) , 570-574
Comparison of GaN pixel sensors with different sizes
- 27 March 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (4) , 570-574
Comparison of GaN pixel sensors with different sizes
- 24 May 2024
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 8 (3) , 1480-1485
Silicon PIN array-based charge measurement detector for HERD beam test
- 24 May 2024
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 8 (3) , 1480-1485
Silicon PIN array-based charge measurement detector for HERD beam test
- Open Access
Capacitive coupling study of the HERD SCD prototype: preliminary results
The Silicon Charge Detector (SCD) is a subdetector of the High Energy Cosmic Radiation Detection payload. The dynamic range of the silicon microstrip detector can be extended by the capacitive coupling effect, which is related to the interstrip capacitance and the coupling capacitance. A detector prototype with several sets of parameters was designed and tested in the ion beams at the CERN Super Proton Synchrotron. The capacitive coupling fractions with readout strip and floating strip incidences were studied using the beam test data and SPICE simulation.
Open AccessCapacitive coupling study of the HERD SCD prototype: preliminary results
The Silicon Charge Detector (SCD) is a subdetector of the High Energy Cosmic Radiation Detection payload. The dynamic range of the silicon microstrip detector can be extended by the capacitive coupling effect, which is related to the interstrip capacitance and the coupling capacitance. A detector prototype with several sets of parameters was designed and tested in the ion beams at the CERN Super Proton Synchrotron. The capacitive coupling fractions with readout strip and floating strip incidences were studied using the beam test data and SPICE simulation.
- Open Access
- 12 December 2023
- Published by American Astronomical Society in The Astrophysical Journal Supplement Series
- Vol. 270 (1) , 3
Calibration of the Timing Performance of GECAM-C
As a new member of the Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) after GECAM-A and GECAM-B, GECAM-C (originally called HEBS), which was launched on board the SATech-01 satellite on 2022 July 27, aims to monitor and localize X-ray and gamma-ray transients from ∼6 keV to 6 MeV. GECAM-C utilizes a similar design to GECAM but operates in a more complex orbital environment. In this work, we utilize the secondary particles simultaneously produced by the cosmic-ray events on orbit and recorded by multiple detectors to calibrate the relative timing accuracy between all detectors of GECAM-C. We find the result is 0.1 μs, which is the highest time resolution among all GRB detectors ever flown and very helpful in timing analyses such as minimum variable timescale and spectral lags, as well as in time delay localization. Besides this, we calibrate the absolute time accuracy using the one-year Crab Pulsar data observed by GECAM-C and Fermi’s Gamma-ray Burst Monitor, as well as GECAM-C and GECAM-B. The results are 2.02 ± 2.26 μs and 5.82 ± 3.59 μs, respectively. Finally, we investigate the spectral lag between the different energy bands of the Crab Pulsar observed by GECAM and the Gamma-ray Burst Monitor, which is ∼ −0.2 μs keV−1.
- 12 December 2023
- Published by American Astronomical Society in The Astrophysical Journal Supplement Series
- Vol. 270 (1) , 3
Open AccessCalibration of the Timing Performance of GECAM-C
As a new member of the Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) after GECAM-A and GECAM-B, GECAM-C (originally called HEBS), which was launched on board the SATech-01 satellite on 2022 July 27, aims to monitor and localize X-ray and gamma-ray transients from ∼6 keV to 6 MeV. GECAM-C utilizes a similar design to GECAM but operates in a more complex orbital environment. In this work, we utilize the secondary particles simultaneously produced by the cosmic-ray events on orbit and recorded by multiple detectors to calibrate the relative timing accuracy between all detectors of GECAM-C. We find the result is 0.1 μs, which is the highest time resolution among all GRB detectors ever flown and very helpful in timing analyses such as minimum variable timescale and spectral lags, as well as in time delay localization. Besides this, we calibrate the absolute time accuracy using the one-year Crab Pulsar data observed by GECAM-C and Fermi’s Gamma-ray Burst Monitor, as well as GECAM-C and GECAM-B. The results are 2.02 ± 2.26 μs and 5.82 ± 3.59 μs, respectively. Finally, we investigate the spectral lag between the different energy bands of the Crab Pulsar observed by GECAM and the Gamma-ray Burst Monitor, which is ∼ −0.2 μs keV−1.
- 1 September 2023
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 525 (3) , 3399-3412
Ground-based calibration and characterization of LaBr3-SiPM-based gamma-ray detector on GECAM satellite: 8–160 keV
As the main detector of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor mission (GECAM), the calibration of the energy response and detection efficiency of the gamma-ray detector (GRD) is the main content of the ground-based calibration. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8–160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal ($\rm {LaBr_3}$). The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analysed in detail. We show that the calibration campaign is comprehensive, the detector performance meets the flight requirements, and the calibration results generally agree with simulations as expected. The detector’s model was corrected by the ground-based calibration, which led to the establishment of the calibration data base.
- 1 September 2023
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 525 (3) , 3399-3412
Ground-based calibration and characterization of LaBr3-SiPM-based gamma-ray detector on GECAM satellite: 8–160 keV
As the main detector of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor mission (GECAM), the calibration of the energy response and detection efficiency of the gamma-ray detector (GRD) is the main content of the ground-based calibration. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8–160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal ($\rm {LaBr_3}$). The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analysed in detail. We show that the calibration campaign is comprehensive, the detector performance meets the flight requirements, and the calibration results generally agree with simulations as expected. The detector’s model was corrected by the ground-based calibration, which led to the establishment of the calibration data base.
- 17 January 2022
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 6 (1) , 70-77
The data acquisition algorithm designed for the SiPM-based detectors of GECAM satellite
- 17 January 2022
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 6 (1) , 70-77
The data acquisition algorithm designed for the SiPM-based detectors of GECAM satellite
- 15 January 2022
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 6 (1) , 53-62
The design and performance of charged particle detector onboard the GECAM mission
- 15 January 2022
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 6 (1) , 53-62
The design and performance of charged particle detector onboard the GECAM mission